Commit Graph
10 Commits
Author SHA1 Message Date
glenn schrooyenandClaude 2929ece7da SAFETY-125 round 2: the one-inverter maintenance charge is sized to the room too
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 1h0m42s
Owner 2026-10-29: fix N=1 in this hotfix. _charge_headroom() no longer
returns early at one inverter, so the N=1 cheap-window maintenance charge
is held to charge_room_w() as at N=2; SAFETY-84's site-stop rule stays N>=2
only (at N=1 such a stop outranks the shaping anyway). The guard no longer
steps in and gives power at each quarter's end during that charge.

test_safety125.py: N=1 maintenance on 5 s and 10 s meters with late
readings, with and without a banked peak; the row in an N=2 maintenance
charge and in shadow mode; edge cases (blind past the hold, a start
mid-quarter, the summer-time change, the forecast in W, a 10 s meter, the
last second). test_safety84/87: three N=1 pins move. test_safety119: its
quarter-edge hand-back runs keep the old N=1 sizing as a fixture, plus a
check that with the new sizing nothing hands back. CHANGELOG, DECISIONS,
DOCS follow.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-29 14:57:39 +01:00
glenn schrooyenandClaude 8bf25696cb SAFETY-121: a recurring overload warns every quarter
checks / unit (pull_request) Successful in 44m51s
infra-pin / fresh (pull_request) Successful in 1s
TEST-23 F-1: on a 5 s meter a steady overload warned once in 70 min. The
loop was at its bound 4-5 cycles a quarter, all inside SAFETY-119's settle
of 12 cycles (60 s) and under its budget of 8 per 900 s. The simulation
fed the meter a cycle behind the battery reading, so the guard and the
charge chased each other and gave ~20 bound cycles a quarter.

The settle is now 4 cycles and 22 s (HANDBACK_CYCLES, SHORT_SPAN_S), and
the rolling budget one number, 11 per 900 s, at every cycle length. The
cycle length is no longer tracked. Commands unchanged; the re-pinned
digests of test_safety84/87 differ from bee7431 in OUTPUT_CLAMP rows only.
test_safety119 runs the rig's shape (meter in the same cycle) at 1-15 s
and checks a stop keeps the budget (review F2, X3).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-21 10:09:14 +02:00
glenn schrooyenandClaude e27e62ff72 SAFETY-119 round 3b: no-clock budget, fixed-seed tests, accepted limits
checks / unit (pull_request) Successful in 43m1s
infra-pin / fresh (pull_request) Successful in 1s
The rolling budget now holds without a monotonic clock (it never refills).
Quarter-edge tests use seeds 1-3 at 2, 5, 10 and 15 s (no hand-picked seeds).
Re-pin comments point at part 6. DECISIONS lists the limits the owner
accepted with N=8 on 2026-10-20.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 20:46:14 +02:00
glenn schrooyenandClaude e76c70ecb0 SAFETY-119 round 2: one settle window per run of hand-backs
checks / unit (pull_request) Failing after 42m32s
infra-pin / fresh (pull_request) Successful in 2s
A hand-back used to restart the window, so a guard and a charge taking
turns hid the loop's integrator bound for good (0 warnings in 2 h; 28
before the fix). A run of hand-backs (the wire away less than a settle
between them) now hides the bound for at most 11 bound cycles and 22 s in
all, then it counts. The quarter-edge kick stays hidden. No command or text
changes. Tests for the two reviewer mutants that only unit checks caught
(a restart counted as a hand-back; span only), DECISIONS gives the delay at
2 s, 5 s and 60 s. test_safety87.py:543 shortened.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-20 00:52:24 +02:00
glenn schrooyenandClaude b0c2e5977d SAFETY-119: re-pin test_safety84/87 digests (log only); prove it
checks / unit (pull_request) Successful in 41m47s
infra-pin / fresh (pull_request) Successful in 1s
The re-pinned digests differ only in OUTPUT_CLAMP log rows; every command
and claim is the same as without the fix (test_safety119.py part 5).
DECISIONS: the delay at a 5 s meter and the open swap case.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 15:30:18 +02:00
adminandClaude Opus 5.5 6872353e2e SAFETY-91: a held battery is drawn only after the others are full
checks / unit (pull_request) Successful in 26m19s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 a battery at or under its own peak reserve now weighs 0 whenever
the site gives (not only for the peak), a draining battery's pin becomes
a floor at its drain rate so it rises before the held one gives, and a
quarter's edge is graded on the next quarter when its first telegram is
late. SAFETY-25 option A stays: the held battery is still drawn once the
others are full. N=1 unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 14:03:54 +02:00
Claude a4a04d203c SAFETY-87 review: grade the three surviving review mutants
checks / unit (pull_request) Successful in 25m5s
infra-pin / fresh (pull_request) Successful in 1s
A battery refusing only to charge stays able; the reserve alarm is graded
on the real limit, not the aim; 'control still runs' is set on the two
peak rows only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 11:07:43 +02:00
Claude aa501ffec7 SAFETY-87 review: maintenance pins beside a held battery
checks / unit (pull_request) Successful in 26m5s
infra-pin / fresh (pull_request) Successful in 1s
A draining battery that may still give is raised from its drain rate
towards its rating for the peak floor while another battery is held
(peak > drain); before, the floor's rest landed on the held battery. In a
HOLD, a held battery's own pin counts among the others: a held drain no
longer over-places the site, and a held charge probe no longer parks it.

Tests: test_safety87.py part 10 (drain beside a held battery, N=3 HOLD,
unknown cut-out and unread level at N=3, a stopping row outranks the
running peak alarm). DECISIONS entry updated, incl. the modes-on exception.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 10:50:01 +02:00
Claude d89c093318 SAFETY-87: grade the surviving mutants (dropped battery, own-floor naming, pair permission, latched row)
checks / unit (pull_request) Successful in 24m56s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 09:55:29 +02:00
Claude d0db5b8c39 SAFETY-87: peak guard uses every battery that can still give
checks / unit (pull_request) Successful in 25m45s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 a battery at or under its own peak reserve is held: it gives
nothing for the peak (weight 0 while the site gives) and the guard's need
is placed on the live, non-refusing batteries above theirs. The guard is
floor-limited, and alarms, only when those cannot hold the limit at full
power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold
the Home page at 0 W, because control keeps running. N=1 is byte-identical.

DECISIONS/SAFETY-87-guard-uses-able-batteries.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 09:29:30 +02:00