Commit Graph
17 Commits
Author SHA1 Message Date
Claude e0138a2ae5 EV-20: SPIKE-05 decisions C1, C6, C9 (brief v5) with rows for C1, C5, C6, C8, C9
checks / unit (pull_request) Successful in 34m42s
infra-pin / fresh (pull_request) Successful in 2s
C1: an own 0 A not yet read back is kept with the mode; a start in Off with
it writes the 0 A (retried), without it nothing; a start that will not write
warns once when the charger still has the add-on's current. C6: Solar's 30 s
gate also counts from Manual's latest write. C9: an exit also owes its 0 A
when the read-back shows Solar's own value. Rows for C5 and C8 too.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 21:33:28 +01:00
Claude 226e5a1e8b EV-20: Car Solar mode, spare sun to the car (charging only)
checks / unit (pull_request) Successful in 57m6s
infra-pin / fresh (pull_request) Successful in 3s
Solar as a second writer next to Manual (carmode.SolarPlan, SolarWriter on
ManualWriter's one write site, safe phase sequence and other-writer watch):
signed spare, Batteries first on the batteries' ratings, the margin, whole
amps rounded down, the 30 s / 1 A rule, start and pause dwells, auto phases,
a one-phase car. Every way out ends at 0 A, retried by EV-04's rule; at
shutdown before the inverters, three tries inside 15 s (D3); start-up and a
returning charger or HA write 0 A first (D2); never over another writer's
hold. The peak guard treats a Solar car as a Manual car (D1 wording). Solar
kWh sensor and card line; select.goodwe_car_sun_first; ev_margin_w,
ev_start_min, ev_pause_min with config, validator, translations, DOCS,
DECISIONS and CHANGELOG.

Checks: test_ev20.py, test_ev20_exits.py, test_ev20_writers.py,
test_ev20_guard.py, test_ev20_long.py, test_ev20_long_car.py,
test_ev20_fuzz.py (harness tools/ev20_sun.py, ev20_kit.py, ev20_day.py);
test_ev03/test_ev04 no longer use Solar as the refused example.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 20:31:26 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00
glenn schrooyenandClaude 9a76f1a968 MAINT-28 fix-forward rounds 1-4, re-applied after the release/1.0 merge
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 0020756aab Revert "Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)""
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 7bc8ad264b Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)"
checks / unit (pull_request) Successful in 27m32s
infra-pin / fresh (pull_request) Successful in 2s
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 01:33:24 +01:00
glenn schrooyenandClaude e7706150e8 MAINT-28: DECISIONS gives the measured reason for the uncapped give (review M-1); ctl_cycle comment one line + pointer (L-1)
checks / unit (pull_request) Successful in 27m38s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 05:53:55 +01:00
glenn schrooyenandClaude 29a8a05f30 MAINT-28: shorter test_maint28 runs (892 s -> ~280 s), digests re-pinned on 1b5f7c9; hold kept through the two short holds (documented); DECISIONS duplicate removed
checks / unit (pull_request) Successful in 40m7s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 02:29:27 +01:00
glenn schrooyenandClaude edf30f345a MAINT-28: keep the single shaping_suspended(.., maint_aim) call site (test_peak_margin pin); shaping_held takes its answer
checks / unit (pull_request) Successful in 32m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:58:19 +01:00
glenn schrooyenandClaude 8640bfcbc1 MAINT-28: hold only where MAINT-24 moved the aim (banked peak above the cap); test_safety119 pins stay
checks / unit (pull_request) Failing after 34m27s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:13:57 +01:00
glenn schrooyenandClaude 92f0387415 MAINT-28: reset the hold every cycle, test it; digests vs 1b5f7c9; DECISIONS numbers and mutants
checks / unit (pull_request) Failing after 36m49s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:44:32 +01:00
glenn schrooyenandClaude 4f9aa5223f MAINT-28: the hold is for N=2 and up (SAFETY-87 N=1 pins), N=1 peak digest test
checks / unit (pull_request) Failing after 36m51s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:28:01 +01:00
glenn schrooyenandClaude 8cd10ee6aa MAINT-28: during a real peak the maintenance charge stays paused until the house is clear of the aim
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m11s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 21:51:56 +01:00
glenn schrooyenandClaude 54a738dd87 MAINT-24: a started maintenance charge gets the cheap night
checks / unit (pull_request) Failing after 41m45s
infra-pin / fresh (pull_request) Successful in 2s
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:07:44 +01:00
goodwe-agent c50e2279dd SAFETY-136: a gentler loop on a slow meter until the last move shows
checks / unit (pull_request) Successful in 26m18s
infra-pin / fresh (pull_request) Successful in 2s
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 14:49:26 +01:00
glenn schrooyenandClaude 3939211176 MAINT-21: app/ctl_cycle.py - Controller.cycle, whole
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:29:52 +01:00