159d7461d8 |
UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only refusal, the add-on now serves the setup wizard in setup-only mode instead of exiting 78. It builds no controller, MQTT client or meter task, its HomeAssistant is read-only (every service call refuses before sending), Controller refuses a read-only HomeAssistant, and /action answers 409. Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md. Wizard fixes from the UX-13 P4 test: - F1: /config/validate converts what it can, so a conversion error blocks its own step and the live checks still run; save 422 carries steps. - F2: saves send the model the page opened (base); only keys this page changed are written onto the blob stored now. - A meter entity missing from Home Assistant is red on the last step. - Step 1 says the reading went down after a skip that followed a fall. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
06aa09e28c |
SAFETY-73 review: a refusal needs 22 s of evidence, and the cut-out warning is for giving only
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) * LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both units 10-16 times an hour after load steps (site held 0 W). 2 s and slower ticks are unchanged. - REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that stops taking charge is always above its cut-out level. - test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal; the release/1.0 checks are restored and a span check added. - test_refusal_units: lagged-reading and full-battery plants, two new checks, U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
1a9c7523c9 |
Merge release/1.0 (a36dca6) into SAFETY-73-per-unit-refusal
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
f8d63cc614 |
UX-13 P1: page shell and Home screen on a structured /status
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
month_peak and control beside the old fields. The plan is what the add-on
does today: the arbitrage verdict (the same plan.arbitrage() call as the
cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
|
||
|
|
016ed5a5a3 |
SAFETY-73: a battery that refuses, per inverter, with two or more
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R). A unit that gives < 100 W for 12 cycles in one direction while asked > 200 W, or trips its stale-reading gate on a ~0 W reading, gets a P_SAFETY `refused` unit limit closing that direction, so the allocator hands its share to the others within their own limits. Probe: a +-200 W pin every 15 min, one unit at a time, only while the site asks 200 W that way. All units refusing: the site law holds 0 W. Exits reseed the site target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above the configured cut-out; SAFETY-42/43 no longer report a refusing unit. N=1 unchanged. test_refusal_units.py: cases a/b/c on flat and jitter registers against the old behaviour, probes, recovery, exits; mutations U1-U13 all red. TEST-19 no-fault campaign: 0 engagements in 5280 runs. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3c0f2b9669 |
SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's own 100 W answer, not below saturation_w: a battery derated to 100-499 W was held at 0 W ~93 % of the time. - A reading of 100 W or more in the held direction ends the refusal, probe or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy reading's lag, and that held a healthy step at 0 W until the next probe. - test_refusal part 5b and a seed test; DOCS states the N>1 limit; the DECISIONS record carries the traced cause of the replay's extra trips. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
1f97c7652f |
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
At the BMS cut-out the saturation freeze held the last request for hours (+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid error changed sign. compute() now carries a refused direction: after SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go on charge, an answered probe, stop/start or another writer. A stale-reading trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's ~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A). test_refusal.py drives the real Controller and gate; tools/replay_refusal.py replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what SAFETY-58/59 must take into account. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3c298af3d8 |
UX-11 review: restored stops log their figures to events, the quiet-meter WARNING is rate-limited
- After a restart, each restored stop (direction per inverter and site, delivery, circulation) also writes its saved reason to the action log. log_level defaults to info and events starts empty, so the DEBUG evidence alone left the figures only in state.json. - A flapping meter (ha_signed under a flat load, 42-97 s between changes) logs at most one WARNING/INFO pair per 10 minutes, with the episodes in between at DEBUG. - LONG_LINE_OK refuses any key whose text is a safety reason. - test_watchdog keeps the byte pin beside the meaning pin, since the text did not change. - DOCS says the DEBUG line needs log_level debug. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c628099e69 |
UX-11: the meter WARNING names the limit only, as 'over 30 seconds'
TEST-23 showed 'No meter reading for 30 seconds, over the limit of 30 seconds': the age is 30.4 s, which rounds to the limit. The limit alone is always true at the moment the line is logged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
29837dfaa7 |
UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG
- Every WARNING/ERROR line that reported a safety reason (direction, delivery, stuck meter, stale reading, peak guard, circulation, over-rating) now ends in the reason's code (messages.reason_code()). The reason itself, figures and limits included, is on a DEBUG line right after it and in the action log. - The reasons and state.json are unchanged, so an old state file loads and shows the same way: every saved reason opens with its code. - test_messages part 6 checks every WARNING+ line at 25 words as logged; nine non-safety families are listed with a reason and capped. The byte pin in test_watchdog now pins the meaning, in order. - The meter logs one WARNING per quiet episode, and INFO when back, so the red row's "the add-on log shows why" holds. The Why line past the hold names the missing reading. Action log: "25 engagements", "Shadow mode off: ...". No trigger, latch, threshold, log level, notification id, cadence, row colour or banner order changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
e0b578756f |
UX-10 review: the line as logged gets the red-alarm shape, clamp lines at 30 words, plain HA 400
Part 6 checked the quoted reason alone, so title + reason + tails logged as 4+ sentences. It now also checks the whole line (at most 3 sentences, none over 30 words); 25 lines failed and are rewritten (one-sentence wrappers, two-sentence circulation and peak reasons, STALE_READING's fixed limits on a DEBUG line). The clamp lines for one inverter are pinned at 30 words with OUTPUT_CLAMP and the numbers kept. Home Assistant's bare '400: Bad Request' while it loads becomes one plain line; still WARNING, throttled, a failed write. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
23a3a3f5b5 |
UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified as data or as a built text, and every built text is produced by the real code and checked. This is the gap the 2d scan had: it counted `%s` as one word, so reasons built by loop_clamp_note() and friends were never seen. - Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept): OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak guard (codes now PEAK_GUARD*), the migration report, price feed, price history and gate reasons. Plurals via messages.times()/count(). - Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff "one every 15 minutes or every hour", "not final yet" dropped. - Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO, aiohttp access log only at log level debug, settings warnings once per start, one plain line per Home Assistant outage (hass.Outage). - INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE", "NOT_OBSERVED", "did NOT land", "AND". - Display bugs: WHY_WINNER covers every winner and safety reason (main.why_key(), part 7 finds them in the code); the meter row is amber "waiting for the first reading" inside its limit after a start; the missing-reading age is counted when the page asks. - STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section). No change to safety behaviour, alarm levels, notification ids, triggers, cadence or the banner cascade. One row colour changes (meter at start), justified in DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
569f16aa91 |
UX-08 2d review: action log reachable in status JSON, engaged peak row pinned, imported keys expanded
- status_payload() also returns the action log as `events`. The page does not render it. Some entries (a dropped inverter's reason, the peak guard's projection, unplaced watts) are written nowhere else, and DOCS still points installers at the action log. - test_peakguard pins the engaged row's ordered pair (the battery's share, then the limit). - test_messages expands setting keys named by constants imported from another app module, so the shown-text 30-word scan counts them. - p1.py: 'A meter message could not be read'. DOCS glossary: control board in plain words, with the hardware in an installer note. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
6a95447248 |
UX-08 2d: plain log lines, the rest of the status page, and DOCS
Every WARNING and ERROR line is one plain line of at most 25 words, with no card ids, capitals or semicolons; the reasoning of the ten longest is on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0). The status page: the month-peak and peak-guard rows, the stale-reading row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the Stopped banner and the line under the buttons, which now shows the plain hint of each event instead of the raw action log. The Supervisor question at start logs one line with a real reason. Refusals are counted as shown (labels expanded, long cases driven), seven were shortened, the card and parse errors lost their internals, a blank value reads "empty", and the panel no longer files inverters.max_w under the flat max_w. Option names lose "(JSON)", the NL texts are checked too. DOCS gets a glossary (control board, isolator, Developer Tools) and card ids move from headings to a "For installers" line. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
63dee6db1e |
UX-09 review: short start-up timeout, latch rows pinned in shadow, plainer rows
The Supervisor questions for the Details link are asked together with a 3 s budget instead of one after the other at 10 s each, so a hung Supervisor cannot hold control start for 20 s. In shadow mode the circulating and site-direction latches are pinned to keep their own red row that says how they clear. Plainer inverter and battery wording. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
00e3ee9de8 |
UX-09: Details link for current HA, "would" in shadow mode, plain terms
- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and older. Slug from GET /addons/self/info, version from GET /info, hostname as fallback. - Shadow mode: the over-rating alarm and row say what would have been sent, the peak alarm no longer says the battery is giving all it can. - "controller" -> "the add-on" / "control". Settings named by their labels; four labels changed to match (Peak reserve, Battery level entity, Solar production ..., Reversed-sign solar entities). - Shadow banner and inverter link notes moved to messages.py and checked. - DOCS Notifications and Status page rewritten for home owners, with a "For installers" part each. Allowlist 168 -> 167. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
571b884315 |
UX-08 phase 2b review: keep over-rating evidence, pin latch clearing, plainer rows
- During a bound episode an earlier over-rating count stays on the page (amber, under its own title); test_clamp pins it. - test_messages pins that every latch row says how it clears. - pv_entities description no longer claims the page names the entity (en, nl); allowlist hash updated for that option-desc line. - Plainer texts: multi-inverter direction banner, "fine now" after an episode, and the e-stop, peak-forecast and peak-guard-waiting rows move to messages.py. - TEL-12 DECISIONS points to UX-08 item 3 for the retired row rule. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
d017fc67bf |
UX-08 phase 2b: short, plain status rows and page banners
Every Commissioning row and every page banner is now worded in app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red row up to three sentences so a latch still says how it clears, banners at most 12 words. No row names a Home Assistant entity: sensors by their setting, solar sources by their place in the list. Reason codes and limits stay on the log line and event list; rows keep the numbers a reader acts on. UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound engagements separately, and after an episode each count shows under its own alarm's title instead of both under "output clamp". No row colour, visibility or banner order changed. Rows carry an "id" so the tests pin meaning rather than wording. The row and banner kinds leave the allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in DECISIONS/UX-08-short-notifications.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
7b65a3e69a |
UX-08 review: tighter notification texts, and two meaning fixes
- not delivering: the body said control keeps running and then "start
control"; clearing it takes stop then start, and it now says so.
- peak reserve: the "reserve not set" branch is really soc_floor None,
i.e. an inverter's cut-out level missing; it now names that. The title
is true on all three branches ("Battery stopped limiting the peak").
- no semicolon run-ons in bodies (STYLE.md + test); loop-bound, circulating,
meter-frozen and multi-unit over-rating bodies rewritten to match.
- allowlist cap is now exact, so a shrink cannot leave room to regrow.
- DOCS names the settings behind "peak reserve" and "cut-out level";
DECISIONS no longer states the HA anchor behaviour as fact.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
50ccea3dd7 |
UX-08 phase 2a: short, plain notifications, and a ratchet for the rest
Every HA notification the add-on raises now has a title of at most 5 everyday words and a one-sentence body; a red alarm may use three so no action is lost. The texts live in app/messages.py, the rule in STYLE.md, and the detail that moved out in DOCS.md "Notifications", which each body links to. No notification_id, trigger or cadence changed. test_messages.py enforces the rule on every notification, fails any notification worded outside app/messages.py, and ratchets the kinds not yet rewritten (rows, banners, refusals, logs, options) through a shrinking allowlist of 200. Six tests re-pinned from prose to meaning. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
55a6d5dcdb |
SAFETY-40 review: integrator-bound WARNING gets its own notification id
A later anti-windup notice could replace a write-path BUG SIGNAL notice
under the shared goodwe_output_clamp id (escalation ignores the budget).
The WARNING now uses goodwe_integrator_bound and points to DOCS; the
cadence sentence in DOCS is corrected. Tests pin both ids (red on
|
||
|
|
fd14569a71 |
SAFETY-40: the integrator bound is not a BUG SIGNAL; numbers from the clamp tick
The clamp alarm gave `i_clamped` (normal anti-windup) the over-rating BUG SIGNAL text, printed `Decision.i_w` as "the loop asked for", and printed `self.target` (after slew/freeze) as "was clamped to". - clamp.loop_clamp_note(): i_clamped says "the loop's integrator reached its N W anti-windup bound" with this tick's command; clamped keeps BUG SIGNAL with the requested command and the clamp's own result. - Decision carries i_bound_w / requested_w / clamped_w, set at the clamp. - i_clamped still counts and notifies (same id, cadence, SAFETY-41 escalation) but as a WARNING, amber row, plain title. A bug has its own notification budget and its text is not overwritten within an episode. - test_clamp.py part 9: red on the old code per defect; 5 mutations killed. - DOCS.md alarm section (and its stale 30 s cadence), DECISIONS/SAFETY-40. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
6028e21298 |
SAFETY-34: re-assert latched alarms, because a Core restart keeps the add-on
A Core-only restart wipes persistent_notification and does NOT restart the add-on (measured on TEST-23: the add-on's SAFETY-31 card was gone 4 min after `docker restart test23-ha`, add-on StartedAt unchanged). The latched SAFETY-31 and SAFETY-42 cards were re-raised only on add-on start, so they stayed gone. They are now re-asserted every REANNOUNCE_S = 300 s while tripped (same notification_id, so it replaces). test_watchdog part 6 and test_delivery part 8b grade it with the same process across the "restart"; red on the old code. The docstrings that said the add-on restarts with HA are corrected. Record: goodwe docs/DECISIONS.md, SAFETY-34 D4. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
7559d21eda |
TEL-14: PV sign declared per entity (pv_invert_entities)
checks / unit (pull_request) Successful in 8m39s
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive for consumption and negative for production. `pv_invert_entities` lists the ones to flip; the flip is applied per member inside pv.total(), before the sum, so the MQTT `pv` row and the status page carry the corrected figure. Default [] is byte-identical to 0.12.0. Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0): a parallel list validates the 0.12.0 blob unchanged and renders as its own translated repeatable field; dicts on pv_entities refuse 0.12.0's stored strings; a prefix is invisible syntax; a global bool cannot describe a mixed roster. Status page marks flipped entities and cautions per entity below -50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged. Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
71d2d4a37a |
SAFETY-61: the control task's death ends the process, after the wind-down
checks / unit (pull_request) Successful in 8m22s
A done-callback on run_control()'s task logs the traceback at the death and sets `stop`; amain() runs the ordinary wind-down (shutdown() -> command_site_zero()) and main() exits 70 (EX_SOFTWARE). Normal stops and run_control()'s refusal path are ignored by the callback (still 0 / 78). hass.py: a malformed JSON body, a JSON non-object, and an undecodable error body are an absence / a failed write, not an exception into the loop. checks() gains a first "control loop" row, red past FIRMWARE_INGEST_VETO_S. Why exit rather than restart in-process, and what the Supervisor actually does on exit (restarts only with the per-install Watchdog toggle on, default off): DECISIONS/SAFETY-61-control-task-death.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
0ef9565071 |
TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner reported within minutes of it going live that they have several PV inverters and could configure one - which is ordinary for a multi-string roof, not a property of one house. `pv_entities` is the roster and the row carries the SITE total. ⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`, and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no irradiance" conclusion the channel exists to TEST. So `pv.total()` answers `None` the moment any configured entity is absent: the topic carries HA's own `None`, the entity goes to `unknown`, the recorder records a GAP. The alternative (the partial sum beside a contributor count) was implemented and run as mutation N1b; it loses because the MQTT row is read COLD a week later by an attribution that would believe it, while the qualifying count would live in a second entity with its own history. The partial information is not thrown away - the STATUS PAGE names every entity that reported, with its watts, and every one that did not, with its reason, because that surface is read LIVE by a human who wants the diagnostic. ⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is `is None`, never falsiness - a roster that blanked the site on a zero would report an absence on every clear evening. THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list: tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an 0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and deepmerge's list strategy is `override` so a `[]` default does not rescue it - the live add-on would not start. `match(.*)?` does accept both shapes and is rejected for a different, measured reason: it validates nothing (a string, a list and the integer 417 all pass) and renders as a plain text box. So `pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for `inverters:`, with a status caution saying which key won - a union would double-count the inverter the old key still names. STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than replaced and now grades five claims over three document sets. The control hash is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the roster control document is byte-identical between the two trees. 2/5 is a claim TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly as 0.11.0 does" is a real cross-tree identity over control AND telemetry. ⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit 24: a discriminator defined as "the baseline lacks this feature" dies on the release that ships the feature, and dies as a false refusal. Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B (`sum` -> `max`, the same three characters) and was run on a fresh copy with `cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO contributions in two units with absence driven at EVERY position - a member contributing 0 W could go absent without moving the sum of the rest, which is habit 23 with a coinciding value in the arithmetic rather than in the plant. 31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0, so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG entry is wanted and deliberately not written - 11b forbids `## Unreleased` and the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the material it needs. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
07ba3433ed |
TEL-11: PV production stops being invisible, and stays out of the control law
checks / unit (pull_request) Successful in 8m6s
OPT-10 measured that this site's pack reaches 90 % SoC on 2 days of 16 and that
20.5 kWh of surplus left the site while the pack had room - 12.6 kWh of it with
the battery not charging at all - and could not say WHY, because PV production
is recorded NOWHERE. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which
is the only software defect) and guessing between them is how an optimiser gets
tuned to solve a cloud problem. This card adds the channel. It does not do the
attribution.
AN HA ENTITY, NOT A REGISTER, AND THAT IS A PRODUCT DECISION. This add-on's
RS485 bus carries the BATTERY inverter it drives; a household's PV inverter is
normally a different box from a different vendor reporting into Home Assistant
through its own integration. `pv_entity` takes whatever `sensor.*` the site's
own PV integration provides, any brand HA can read.
POSITIVE IS PRODUCTION, AND THERE IS NO `pv_invert`. The convention is derived
rather than assumed: `meter_entity` is positive when IMPORTING and `batt_entity`
is positive when DISCHARGING (DOCS.md, Sources), both of which are "power
arriving at the house's AC bus", and production arrives there too. Those two
keys carry invert flags because they are BIPOLAR and are READ BY THE CONTROL
PATH - `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
circulating-power sensor, so a reversed sensor hands the site a plausible number
it acts on. Production is unipolar and is read by nothing: a reversed sensor
announces itself as -4 kW at noon in the very history this card creates, and a
flag would only let an installer hide it. No negative-value alarm either - a PV
inverter's own standby draw makes a small negative reading at night ordinary, so
any threshold would be a number nobody measured.
ABSENCE IS NEVER ZERO, AND "DROPPED" IS NOT ABSENT. `publish()` SKIPS a None,
which is right for `circulation` and exactly wrong here: a skipped row leaves
Home Assistant holding the last number forever and the recorder draws a FLAT
LINE through the outage, which is indistinguishable from a measurement and
manufactures the "there was no surplus" conclusion this card exists to TEST. So
the absence is published, with HA's own payload: `mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it BEFORE the numeric branch,
so the entity's state becomes `unknown` and the recorder stores a GAP. Read out
of home-assistant/core `dev` on 2026-09-24 and quoted at the constant.
`ABSENT_AS_UNKNOWN` is a one-key set and the suite asserts `circulation: None`
is STILL dropped.
THE UNIT IS READ OFF THE ENTITY. `mW`, `W`, `kW`, `MW`, `GW`, `TW` - HA's own
`UnitOfPower`, every factor an exact power of ten. A sensor with no unit, or a
unit outside that table, is REFUSED by name and the status page says which.
`read_inputs()`'s `abs(raw) < 50` kW-or-W guess is safe for a quarter-hour
demand forecast and is NOT safe here: 30 W of dusk is an ordinary reading and
that heuristic would publish it as 30 kW.
GENUINELY OPTIONAL, AND NOT A SECOND `price_now_entity`. validate.py does not
mention the key - it cannot conflict with anything, because nothing else reads
it. The MQTT row lives in a new `OPTIONAL_SENSORS` list whose `include` argument
DEFAULTS TO EMPTY, so every caller that has never heard of `pv_entity` -
test_mqtt.py's fixtures, tools/rehearse_roster.py, anything written next year -
announces exactly what it announced before. Unset: no state call at all, no
entity, no topic, no status row, no page row. Set and failing: a CAUTION
(`ok=False, warn=True`), never a `bad` row, so a telemetry channel can never put
a battery site into NOT READY.
IT MUST NOT BECOME A CONTROL INPUT, AND THAT IS GRADED TWICE. `test_pv.py`
part 6 drives 40 cycles of the real `cycle()` and asserts the commands are
bit-identical across unset / no reading / 0 W / 8 kW, with a COMPUTED census
(33 modules under app/) showing the material is mentioned in exactly three:
pv.py, main.py, mqtt.py. `tools/tel11_pv_trace.py` is the cross-tree half -
`safety56_behaviour_trace.py`'s pattern with a DIFFERENT control clause, because
this card's claim is that nothing differs rather than that only sentences do: it
REFUSES unless the two `app/` fingerprints differ and unless exactly one side
reacts to the option. Measured on 41 stimulus cells:
control release/1.0 unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
control TEL-11 unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
control TEL-11 set 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
telemetry release/1.0 unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
telemetry TEL-11 unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
telemetry TEL-11 set 4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f
UNSET is byte-identical in BOTH documents, which is stronger than "the control
path is untouched": an install that does not set the option sees no change of
any kind, announcement and status rows included.
⚠️ AND THE CARD'S CENTRAL MUTATION WAS A SURVIVOR ON THE FIRST BATTERY.
`self.grid -= self.pv_w` in `read_inputs()` - +106 B, on disk, purged, genuinely
running - came back GREEN, because the fixture drove a 6 kW export over 12
cycles, which puts the loop AGAINST ITS RAIL: a command moving `slew_w` every
cycle produces the same ramp for -6000 W and for -14 000 W of apparent error.
MUTATION.md habit 23 with a saturated ACTUATOR in place of a coinciding value,
and it is in that file now as the habit's second instance. The fixture now
drives a 600 W import the loop SETTLES on, against a responsive meter, and asks
habit 23's own question as its own check: shift the METER by the same 8 kW and
confirm the commands really would have moved.
Evidence: 31/31 suites green in the CI image, checks.yml's exact command, purged
tree, `:ro`. Ten mutations, NO survivors, each on its own `cp -a` of the tree so
habit 18's revert hazard is closed by construction - table in
`DECISIONS/TEL-11-pv-production.md` §7 with byte deltas and sha256s.
⚠️ THIS IS A RUNTIME CHANGE BEHIND AN UNCHANGED VERSION, AND
`tools/predeploy_check.py` WILL REFUSE IT. `app/`, `config.yaml` and
`translations/` are all in its `RUNTIME` tuple and `config.yaml` still reads
0.10.1, so the gate reports a NO-OP deploy until a version is cut. That is PKG's
call and this card does not take it.
No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading
that is not config.yaml's `version:`, and opening one would mean taking that
same packaging decision. The operator account is in DOCS.md.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
8a6acd9fa2 |
SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can
checks / unit (pull_request) Successful in 8m0s
Text only. No behaviour change - same conjunction, same limits, same MISSING, same 0 W, same NOT READY. `tools/safety56_behaviour_trace.py` says so: 2390 capture reads, a 66-cell swept grid, and six driven controller worlds produce the byte-identical document `6030175e...` on origin/release/1.0 and on this branch, while the sentences differ. THE DEFECT. SAFETY-37's conjunction is satisfied by two disjoint worlds - the register has stopped reporting reality, or the SOURCE cannot comply with the command - and nothing `freshness.py` is handed separates them. Three sentences asserted the first. On the live 2026-09-21 episode it was the second: the pack read 11 % for the whole 850 s hold, every command in that hold was a discharge, and the register answered the first CHARGE command three seconds later. The readiness row was worse still, because it asserted a false fact about a NAMED entity that was present, numeric and updating - so the operator opened Developer Tools, found it working, and had every reason to conclude the diagnostics were broken. THE FIX. Each message states what was OBSERVED and names BOTH explanations. Three wordings, no shared helper: two are a log line about a behaviour, the third is a banner about an entity, and a helper serving both would drop whichever half the other caller does not need. SoC stays STATED, NOT WIRED - part 11b drives the two worlds at 50 % and 11 % and the sentence does not move one byte. The row does not branch on `batt_fresh.stale` either: `stale_note()` already rides `liveness_notes()` a few rows below, so the discriminator is "is that row there?", and part 11d asserts it is present in one world and absent in the other. THE CHECKS. test_freshness.py part 11 builds the pair of worlds with ground truth written down rather than derived from the published stream, asserts they are really two (40 of 40 reads differ) while the published stream is bit-identical, and only then grades the sentences. Eleven mutations, all red: each of the three sentences reverted (3, 2 and 2 named reds), the two explanations transposed at ZERO bytes (1), the second explanation deleted (1), the admission of ambiguity replaced by a ranking (1), all three reverted at once (5), and two aimed at this card's own check - collapsing the world pair (2) and emptying the accusation list, which a positive control against the three sentences as 0.10.1 shipped them catches (1). AND TWO OF THE ELEVEN FOUND DEFECTS IN THE CHECK RATHER THAN IN THE CODE. Transposing `label` and `entity` in the row made it unfindable and the run died on an IndexError - a red with no name and every later check ungraded, FCST-06's shape exactly; `_s56_row()` returns a named absence now, 0 named reds before, 3 after. And the first invariance run compared a tree with itself, because it archived a branch whose edits were not committed yet; the tool now REFUSES to report "behaviour unchanged" unless the sentences halves differ, and both of its refusals are driven. SAFETY-57's part 10h check was the handoff and is inverted rather than deleted: it required the accusation to still be present so that removing it had to be a deliberate act. This is that act. Its escape clause is untouched. Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
43c144b8d9 |
SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.
REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:
10:51:24.7 0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
10:51:29.7 the command reaches +1060 W - 800 W of travel
10:52:00 the conjunction arms. Inverter.batt becomes None
10:52:21.7 the site commands 0 W, on the wire
... 0x0518 does not change value for 850.0 s. The setpoint does not
change value for 790.0 s. The house exports 2.4 kW throughout
~11:04 a human restarts the add-on. That is what ends it
AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.
THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.
THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:
the verdict is withdrawn when the obligation that produced it has been gone
for RELEASE_S, and the register is then re-graded from scratch.
RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.
The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.
WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.
Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.
main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.
Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.
Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
b548525d10 |
TEL-10: the loop's integrator stops being invisible
`self.i_w` has been a separate quantity from the command since SAFETY-04 and has left the process nowhere at all - no entity, no MQTT attribute, no log line. The investigation behind SAFETY-48 could only RECONSTRUCT it from the grid trace plus a replay; the reconstruction reproduced about a third of the engagements it was checked against and was discarded, so the card it was gathered for had to be argued from a measurement nobody could stand behind. It could not have been made to work either: `i_w` depends on every cycle before it, including the ones where the arbiter overrode the loop and `main.py` re-seeded `self.i_w = self.target`, and that re-seed is invisible in the grid trace. THREE SITE ROWS, APPENDED AFTER release/1.0's EIGHT. `loop_i` is `Decision.i_w` - the accumulator after the cycle, before the output clamp, the slew limit and quantisation. `loop_lead` is `decision.i_w - prev_w` against the command `compute()` was HANDED, which is not a subtraction of the other two published rows: `Setpoint` is the arbiter's output and is this cycle's, so on any cycle the arbiter overrode the loop the two differ - and that is exactly the cycle on which the integrator was re-seeded. `loop_reason` is `compute()`'s own word; the arbiter's `explain()` prints the winning claim's NAME and has never carried the claim's reason, so `slew-limited` appears in neither the `Why` row nor `Controller status`. Measured on the same cycle: arbiter `'loop -> -5000 W'`, loop `'i-clamped'`. NOTHING IN THE CONTROL PATH MOVED. `app/control.py` is not in this diff. `compute()`, its returned `Decision` and every constant it reads are identical to release/1.0, and all nine of release/1.0's retained discovery messages are byte-identical and still FIRST in the announcement. Evidence: 30/30 suites green in the CI image. Nine mutations, ONE survivor, reported as one: `decision.i_w - self.target` for the lead is +2 B and green because `cycle()` has not reassigned `self.target` at that line - the name is kept for the coupling, not for a behaviour it buys, and M2b (+8 B) is the mutation that does change the value and is red. AND TWO OF THIS CARD'S OWN CHECKS COULD NOT REACH THE FAILURE THEY NAMED. "the published integrator reaches its bound" was GREEN under the card's named mutation (publish `prev_w`, -3 B), because the command reaches the bound too - twelve cycles later. It asserts the LEAD TIME now and is red on 5. "a stopped controller publishes not-running" was GREEN under deleting that branch's assignments (-45 B, -67 B), because the fixture STARTED stopped and `__init__` writes the same values; it stops the controller part-way through a run that has already wound the integrator to -5000 W. Both are MUTATION.md habit 4, found by the battery rather than by review. No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading that is not config.yaml's `version:`, and opening one would mean taking a packaging decision this card does not get to take. The operator account is in DOCS.md and the release note belongs to the next PKG ticket. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e3ccd9f6ea |
SAFETY-47: what a shadow run can show, and the watts on its status row
checks / unit (pull_request) Successful in 7m48s
Not a leak and not a write-path defect. Shadow mode's safety is intact -
the substitution, the re-seed, the authorisation gate and the clamp are
untouched. What was wrong is what three merged documents SAY a shadow run
can show you, and a number on the status row that can be 6.61x what a live
controller would command.
SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT, AND THE DOCUMENTS NOW SAY
SO. The battery is held at 0 W and the carried command is re-seeded to it,
so every measured input - the meter, the billed-quarter accumulator behind
it, the battery power, the SoC - describes a plant that did not respond. A
closed-loop defect is one whose stimulus IS that response. This is the same
property that makes shadow mode safe, so it is not a gap to close later:
the closed-loop answer comes from the closed-loop rig or from a live run.
SAFETY-10 §5 already conceded this for the grid-following loop. It was
never the loop leg's limitation; it is the general case.
THE "STRATEGIES ARE UNAFFECTED" EXEMPTION WAS TRUE UNTIL SAFETY-45 MERGED,
ONE COMMIT EARLIER. That card sizes the buy leg as min(asked, headroom)
with headroom = (900/remaining) x (ceiling - projected), and `projected`
reads the open quarter's accumulator - the meter - which is a function of
what the battery did earlier in that quarter. Measured on TEST-23 stage 3
at peak_cap_w 1500 / house 1200 / max_w 2000, one hour at 5 s:
SAFETY-45's limit cycle NOT visible. 28 onsets live vs 1; grid
-455.5..+3200.0 W vs flat at the 1200 W house;
guard engaged 410/720 cycles vs 0/720.
SAFETY-46's SoC churn NOT visible. The SoC moves 0.000000000 pp.
TARIFF-14's wrong hour VISIBLE, and it is the only one: which hour, at
what price, clearing what spread - identical on
720 of 720 charging cycles at a binding cap.
The exemption narrows to exactly what survives: WHICH hour a strategy picks
and WHY are unaffected; HOW HARD it trades is not. The peak guard's ceiling
and reasons are worth reading from a shadow run; its ENGAGEMENTS are not.
THE NUMBER IS CAVEATED, NOT RE-COMPUTED, AND THAT IS THE DECISION. The
arithmetic is not wrong - 900/remaining is correct for a meter genuinely
under the ceiling, and in shadow the meter genuinely is. It is the right
answer to a question nobody asked. Both surfaces now introduce the watts as
what would have been commanded ON THIS CYCLE, in every state, and carry
shadow.SIZED_FROM_METER whenever a measured billed quarter sized them.
Rejected, and recorded in the decision doc: re-computing it (the recorded
decision would no longer be the decision the shipped path reached, while the
arbiter, clamp, SAFETY-28 gate, log and MQTT all ran on the real one - a
second controller everywhere except the wire); recording nothing (blanks the
row exactly when arbitrage is trading, and the log's edge key is the watts);
and recording the unsized ask beside it (a second number, no warning, and at
the shipped 3500/2000 both figures read 2000 W).
"UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED. Charging
only adds offtake, so the shadow size is >= the live size with EQUALITY at
the start of every quarter. Pairwise over 3600 charging cycles in five
configurations: 0 below, 730 exactly equal. The first draft said "smaller",
which would have been false on every one of those 730.
AND THE PREDICATE IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. arbitrage's
own sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the
headroom came out below the ask - in a shadow run, the START of the quarter,
where the two runs agree to the float. By the end, 900/remaining has
multiplied the headroom past the ask, the trade is not capped, the sentence
is silent, and the record is at its most wrong. A caveat keyed on it would
be quietest exactly where it is needed loudest.
SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED, FOR TWO
INDEPENDENT REASONS, AND CLOSING EITHER ALONE CLOSES NOTHING. Its fixture is
peak_cap_w 15000 against a 350 W house, so the guard never engages and the
sizing is inert - the harness's own comment says so. AND every identity row
reads the FIRST charging sample, where at elapsed=0 the projection IS the
held level and the two runs agree to the float even at a cap that does bind.
Measured: widening the fixture alone leaves that comparison passing. That
second reason is a new shape for MUTATION.md's habit-4 list - an INDEX, not
a fixture - and it is recorded there as the twelfth instance. §6 is re-taken
at a binding cap across the whole run: 716 of 720 charging cycles differ,
headroom 300.0..54000.0 W in shadow against 299.9..307.8 W live, recorded
-2000.0 W against a live -302.4 W.
THE GRADER IS test_arbitrage.py PART 3d, beside SAFETY-45's own closed-loop
regression and built on the same s45_loop() harness, so the runs differ in
one argument. Three lines stand in for _write_unit()'s substitution and
_shadow_settle()'s record and re-seed, marked as a transcription;
test_clamp.py part 8 remains the check on the shipped placement. The section
carries its own precondition into every check: a mutation that stopped
either run trading made it raise on its first min(), kill the file and
report ZERO reds - FCST-06's shape, driven rather than imagined.
AND THE FIX'S OWN FIRST DRAFT CARRIED THE SAME DEFECT. Deleting the caveat
from the action-log line left all 29 files green, because the sentence was
an f-string inside _shadow_settle() and the only suite that drives it uses a
meter_source:off fixture where no arbitrage decision exists. It is
shadow.log_line() now, for the reason words() is a function.
14 mutations, no survivors; M13 and M14 are +0 B and were confirmed on disk
by sha256 with every run purged. M14's first form was aimed at the wrong
direction and correctly survived - min->max makes the shadow record larger,
which is still an upper bound. All 29 check files green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
8fa4febfef |
SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside while it was happening, and each was paid for at the meter first: SAFETY-45's 28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain 310 Wh. There was no way to watch what the optimiser WOULD do without letting it do it. `shadow_mode` runs strategies, arbiter, clamps and guards, records the decision with its reason, and commands nothing. ⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary single writer. The inverter holds its last command forever - it has no meter timeout - so "commands nothing" implemented as "stops writing" would leave whatever was standing when shadow mode came on standing for as long as it was left on, under a page saying nothing is being commanded. That is the failure this repository keeps finding. Refreshing 0 W is also what firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going quiet would keep that board tripped for the whole run, which is an alarm being used as a mode. ⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its own. It is a substitution inside Controller._write_unit() - the single choke point every write already reaches - in the same form as the three above it, and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still grade the number the decision path produced. ⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The Supervisor composes options as {**config.yaml defaults, **stored user options}, so a new key with a new default reaches EVERY EXISTING INSTALL on the next update - including the one regulating a real battery. A boolean default-on would have stopped it silently. There is no mechanism by which one key can default differently for a new install and an existing one, so "default-on for new" is a value the add-on RESOLVES: `auto` is shadow while control is STOPPED and live once it is STARTED. A fresh install ships `auto_start: false` and comes up observing; an install that is controlling is started and does not change by one watt. THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision they would disagree with a meter that never saw it and LATCH A TRIP THAT SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate (SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation (SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch, because their evidence is measured power. The operator stop is the one deliberate change: enforced at the wire rather than as a P_SAFETY claim, which would otherwise make every recorded decision read "stopped". ⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what stands on the wire, which makes the exit safe by construction - and therefore the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow run answers "what would it command now", not "what would it have done next". The strategies are unaffected; all three defects above are visible from one. Graded on the writes and on the rendered surface, never on the flag: 22 mutations, no survivors, including one that lets a write escape and one that goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig, same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %; shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage decision is identical in action, instant, signed power, reason and arbiter winner. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e1b9254626 |
SAFETY-45: a price-driven charge is SIZED by the capacity guard, not switched by it
checks / unit (pull_request) Successful in 7m42s
With arbitrage armed at the shipped defaults, arbitrage and the capacity-tariff guard drove each other in a sustained limit cycle. Re-measured on TEST-23 stage 3's closed rig against |
||
|
|
610725bed9 |
TARIFF-11: the plan's account of itself, corrected and put on the page
Four defects of one shape - the add-on's report of its own tariff plan was wrong, always in the direction that flattered it - and one check, which is the deliverable. 1. `TariffPlan.words` counted POINTS and called them HOURS. The live add-on logged `dynamic_dayahead from generic_dayahead, 132 h` for 132 quarter-hourly points = 33 hours. Belgium moved to a 15-minute MTU on 2025-10-01, so this was wrong every time it was printed, and NOT by a constant factor: a 40-hour soak measured 1.79x .. 5.33x, because §8.3's carried points are hourly while the firm ones are quarter-hourly. `words` now reports both quantities, plus the firm/carried split and the spacing, in FCST-04's *Price history* wording so the two rows can be compared. 2. §8.3's firm-pair refusal and the flat-tariff refusal did the same, and they reach an operator through `self.arb.explain()`. This is exactly the point<->hour conflation TARIFF-14 removed from `at()`, left standing in the prose. `price_forecast.py`'s §8.3 carry-forward log line carried the third instance - a carried-HOUR count over a POINT count - and DOCS quotes it verbatim, so it is corrected here too. 3. The plan reached no HTTP surface at all. `rows["Tariff"]` was `static_status()`'s 30 s-tick sentence and never saw the provider plan - it read 'no static profile' at all 802 soak samples on a site whose feed was answering. It now carries the plan's shape. ⚠️ The two sources are kept distinguishable: the plan half is stamped with its own age, measured from `tariff_at`, because it can be up to TARIFF_MAX_AGE_S (5400 s) old. FCST-04 pins that row to DOCS as a pair; DOCS moves in this commit. 4. `main.py`'s "if and only if" was false. `cycle()` returns at the input hold before `self.arb = None`, so an armed site read `off (arbitrage_enabled)` - naming an option that is on - and, after one completed cycle, showed a decision up to 15 s stale as a current one. The row now reads the OPTION and separates three facts; `cycle_at` and `arb_at` make "this cycle reached no decision" an observation. THE DELIVERABLE IS THE CHECK. All four survived 29 green suites because nothing graded the strings a human is shown. `test_price.py` section 12 renders through the shipped `status_payload()`, parses each number out of its OWN SLOT and compares it against a figure computed from the fixture's construction parameters - not from the property the row was built out of (habit 4), and not as a substring of a sentence the same file wrote (habit 14). The fixture set is four plan shapes and the check computes and prints the field pairs no fixture separates. The *Arbitrage* row's states are driven through real cycles with a sensor answering None and graded by INEQUALITY. No behaviour changed: no threshold, refusal rung, claim or setpoint moved. MUTATIONS: 16, no survivors, one at +0 B (the risky delta) and red. Two were found by the battery INSIDE THIS CARD'S OWN CHECK: a -190 B survivor whose fixture varied two things at once (habit 4), and a mutation whose red was a TRACEBACK in an f-string operand and therefore named nothing (FCST-06). Both closed; the table is on the PR. All 29 test files green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f5ea39784d |
Merge release/1.0 (TARIFF-10) into TARIFF-12
checks / unit (pull_request) Successful in 7m16s
CHANGELOG.md was the only conflict: both entries belong under the same
`## Unreleased` heading, TARIFF-10's first because it merged first. No
version number picked.
app/main.py auto-merged, and was re-read because of it. TARIFF-10 changed
WHICH installs run `run_tariff_refresh()` (`arbitrage.enabled(opts)` ->
`tariff_refresh_wanted(opts)`); this card changed what that task does on
a failed fetch. Nothing in the keep/replace reasoning changed, and the
two newly reachable configurations are now DRIVEN in test_arbitrage.py
8b rather than reasoned about:
* a provider configured with trading DISARMED is the case the guard
was designed for, and needs no second fixture because nothing on
this path reads `arbitrage_enabled` at all - asserted over the AST's
symbols and non-docstring constants, after two drafts of that check
went red on a CORRECT tree for matching the word "arbitrage" in a
docstring and in a log line;
* `price_provider: off` + a `static_profile` resolves to the
CONFIGURED product (`origin: "static"`), so `standing.from_feed` is
false on every refresh and the guard never latches - driven twice in
a row, because a guard that latched there would freeze a static
site's plan at its first window for the life of the install.
Also: the kept-plan log line said "arbitrage stops with it", which after
TARIFF-10 is false on a site that fetches without trading; it now says
"arbitrage, where it is armed, stops with it". The keep decision is
strictly downstream of `resolve_tariff()`, so the §8.3 carry into
price_history - TARIFF-10's whole point - is unaffected either way.
All 29 suites green on the merged tree, including TARIFF-10's new
test_price.py section 13. All eleven mutations RE-DRIVEN on the merged
tree rather than carried over: eleven red, no survivors, every revert
fingerprinted. M11 is new - making the guard conditional on
`arbitrage.enabled(self.o)` (+86 B) is red on five named checks.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
c81289527f |
TARIFF-12: a returned degradation is not a refresh
checks / unit (pull_request) Successful in 7m12s
`run_tariff_refresh()` promised in its own docstring that "a failure does not clear the plan", and enforced it with `except Exception` - a branch a supplier outage never reaches. `load_prices()` states the reason in its own words: it "RETURNS, NEVER RAISES, for every failure a site can actually have", because a degradation arriving as a traceback into the planning tick would stop the controller regulating over an expired certificate. So a dead feed RETURNS a §11.4 plan, the `try` succeeds, and the assignment below it overwrote the good plan unconditionally. With `static_profile` unset - the shipped default, and the normal state of a dynamic-tariff site - `_degrade()` returns `TariffPlan(no_data, None, "none")`: a complete 48-hour plan replaced by nothing, at the FIRST failed fetch, ~27 minutes after the last good one. `TARIFF_MAX_AGE_S` (5400 s) never governed anything and there was no serve-stale window at all. Fourth card in one family: FCST-04's M4 (`not ok` only), FCST-05's HIGH (`(JSONDecodeError, OSError)` only), FCST-06 (`not self.ok` only), and now `except Exception` only, for a path that never raises. The question is now asked once, after the attempt, from the evidence that exists - FCST-06's answer, one module over. The evidence is `TariffPlan.from_feed` (did this resolution observe the configured feed) and the shipped `fresh_tariff_plan()`, reused rather than transcribed. A degradation replaces a standing observation only once that observation has aged out, so `TARIFF_MAX_AGE_S` is now the serve-stale window it reads like. A §11.4 static fallback does not replace a fresh provider plan either, although it carries real prices: every point `_degrade()` builds is `provisional=True`, so `firm_points()` is empty, `arbitrage()` refuses and `cheap_now()` is False - everything a consumer may act on is already off - while a day-ahead price for a given hour does not change once published. The rule is deliberately not symmetrical: a standing plan that is itself a degradation IS replaced, or an outage would freeze the operator's static profile at the window it was first generated for. `tariff_at` does not move on a kept plan. It is the moment of the fetch that produced the plan standing, `fresh_tariff_plan()` judges the age from it, and an unmoved timestamp is the only thing that tells a kept plan from a freshly fetched one. test_arbitrage.py section 8b drives the whole chain with nothing stubbed but the socket: the transport raises the way aiohttp does, load_prices() returns no_data, _degrade() builds the §11.4 plan, and the shipped run_tariff_refresh() decides. A check that patched resolve_tariff to RAISE would have passed against the defect. Ten mutations, ten reds, no survivors; 29/29 suites green. Out of scope and unchanged: the persisted price store still does not back the plan during an outage (FCST-03), and the status banner and the Arbitrage row's lag are separately carded. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e6c45a61e7 |
TARIFF-10: configuring a price provider is what fetches prices
checks / unit (pull_request) Successful in 7m19s
amain() started the background tariff refresh only when arbitrage_enabled was
on, and that option ships false. run_tariff_refresh is the only caller of
resolve_tariff(), which is the only caller of price_history.carry() - so on a
shipped install with a price provider configured nothing was ever fetched: no
plan resolved, /data/price_history.json never created, the Price history status
row reading `empty` for the life of the install, and TARIFF-09's short-horizon
warning unable to fire because there was no fetch to warn about. Measured over
a 40 h two-instance soak on one feed: 0 requests and `present: false` across all
802 samples, against a resolved 132-point plan on the instance with arbitrage
armed.
git log -S puts the refresh task, its arbitrage.enabled() guard AND the DOCS.md
sentence saying a configured provider still fetches in the same commit - OPT-04,
bdd7f18; config.yaml has carried the claim since TARIFF-02,
|
||
|
|
b59f5ce31b |
FCST-04: the carry-forward stops decimating a quarter-hourly feed, and a broken cache stops stopping the add-on
checks / unit (pull_request) Successful in 7m22s
Rework of the FCST-04 branch against review. Every finding below was proven by a runnable script before it was touched and re-run after; every check added or repaired was driven red by a mutation, `__pycache__` purged first (MUTATION.md, TEST-15). 29/29 test files green. ⚠️ H1 - A SUB-HOURLY FEED WAS DECIMATED TO ONE POINT AN HOUR, AND THE SPREAD WENT WITH IT. `fill_from_yesterday()` keyed the published set as `{_utc_hour(p.start): p for p in r.points}` - LAST POINT OF THE HOUR WINS, the other three dropped. `eneco_eddy` is the Belgian imbalance product and settles per QUARTER, and `_validate_raw()` accepts any strictly-increasing spacing, so this is a shape the product supports today. Measured on a 96-point quarter-hourly feed - ALL FIRM, FULLY PUBLISHED, nothing to carry: the plan reached the optimiser as 15 points, the arbitrage spread fell from 0.143 to 0.014 EUR/kWh, and the cheapest "hour" became a `:45` point whose `at()` window runs into the next one. Not the windowing effect this card is about; a feed losing 84 % of its own prints, with no flag anywhere reporting it. The fill now decides only WHICH WHOLE HOURS NEED CARRYING: every published point inside the window passes through BY IDENTITY, and a carried point is added only for a whole hour with no published coverage at all. Same feed, same fixture: 60 of 60 firm points kept, spread 0.134 over the hours still ahead. ⚠️ AND `_audit()` GOT STRICTER, NOT LOOSER - that was the condition on doing it at all. The old post-condition refused any repeated `_utc_hour`, a count that cannot express four points in one hour. Two rules replace it and SUBSUME it: a published point must BE one of that hour's published points by identity and may be emitted only once; a carried point may stand only in an hour absent from the published set, must be flagged True, and may not repeat. So the duplicated carried hour it existed to catch still raises, the same published point emitted twice now raises, and a carried point sharing an hour with a real print now raises too - which the count never looked at. Three mutations, three reds. ⚠️ H2 - A DAY RECORD THAT WAS NOT A RECORD STOPPED THE ADD-ON FROM STARTING. `_load()` validated `version` and that `days` is a dict, never that each VALUE is one. `{"version": 1, "days": {"2026-01-14": "oops"}}` loaded as ok=True, last_error=None, and then `rec.get(...)` raised AttributeError out of `words`, `yesterday()` and `resolve_tariff()` alike. `PriceHistory(...)` and `.words` are both unguarded in `Controller.__init__`, so the controller did not come up - and it never self-healed, because `_remember()` raised on the same record before it could reach `_save()`. That falsifies the CHANGELOG's "A BROKEN CACHE IS NOT A BROKEN CONTROLLER" in the one direction that matters. The asymmetry that produced it is visible in the file: `_parse_points()` is carefully defensive about every field of a POINT and `_load()` was not defensive about the record holding them. Unusable records are now dropped and REPORTED (`words` says how many and why), and `words` is total by construction as a second line. M3 - `yesterday()` WAS OFF BY ONE DAY FOR 00:00-00:59 AFTER SPRING-FORWARD. `brussels()` renders at the FIXED offset for that instant, so `brussels(stamp) - timedelta(days=1)` subtracts 24 ABSOLUTE hours - and the Brussels day before the March transition is 23 hours long. At 2026-03-30T00:30+02:00 it returned 2026-03-28's prices as "yesterday", or `no_data` naming a date that is not yesterday. The arithmetic is now on the local DATE, which has no offset to lose, and both transitions have a check - the module's headline claim had none. M4 - WITH NO /data THE STORE STILL FILLED, IN MEMORY. `_save()` short-circuited on `not ok` while `_remember()` populated `self._days` anyway: `words` said "unavailable" and `yesterday()` answered A SERIES that is gone on the next restart. The module docstring rejects exactly that ("a yesterday that silently forgets") as its reason for not calling makedirs, so the code now matches the docstring rather than contradicting it. M5 - THE PRUNE MUTATION SURVIVED BECAUSE THE STIMULUS WAS DEGENERATE. §8's clock-jump check seeded ONE day, so `if len(self._days) <= KEEP_DAYS: return` fired and the body it is named after never ran: pruning by arithmetic against the clock - which empties the store on exactly the morning the fill is for - passed the whole 29-file suite. The fixture is now written to a file and reopened (`_load()` does not prune, which is how a store legitimately holds more than the cap) with KEEP_DAYS + 2 days, and the mutant is red. M6 - THE AST ORDERING CHECK COULD NOT CATCH A REVERSAL, AND TWO DOCUMENTS CITED IT AS A GUARANTEE. `_calls.index("_remember") < _calls.index("yesterday")` grades `ast.walk` BFS DEPTH: `self._remember(...)` is a statement and `self.yesterday(...)` is an ARGUMENT of the fill, one level deeper, so `_remember` came out first whichever statement was written first - shipped and reversed both scored True. It is now line numbers AND, the half that matters, the behaviour: a feed carrying yesterday alongside today into an EMPTY store must fill the whole horizon; reversed, the lookup finds nothing and the plan is only the published hours. Reversing the two statements is red on both. L14/L9 - KEEP_DAYS = 3 IS THE STEADY STATE EXACTLY, so a newest-N cap has no slack: a feed publishing to D+2, or ONE stray point in the wrong year - which sorts LAST and can never age out - pushes yesterday out for good. `_prune()` now PINS the two days a lookup can actually ask for on top of the cap. Pinning is additive, so it can only RETAIN and the WITNESS-03 property (nothing is deleted by clock arithmetic) is preserved by construction; `stamp` stops being a dead parameter; the store is bounded at KEEP_DAYS + 2. L8 - the horizon end was not floored while `since` was, so a 48 h request made at any instant off the hour returned 49 points. §1's count was green only because its NOW was exactly :00:00, a shape production never has; the fixture now sits at :17:43. L10 - a failed `_save()` leaked its temp file; at 48 writes a day a persistent write failure leaked 48 inodes a day onto the volume that was already the problem. L15 - `{"version": 1.0}` passed, since `1.0 == 1`. L16 - the `_remember` tree walk scanned `app/*.py` only and matched a bare string; it now parses `app/`, `tools/`, `scenarios/` and `estop/` and looks for the NAME, so a comment does not fail it and a call in `tools/` cannot pass unseen. CLAIM-ACCURACY DEFECTS, WHICH THIS REPO TREATS AS REAL: * L7. DOCS said "*Tariff* on the status page reads `provisional` through the morning". FALSE - `tariff_words` is assigned only from the HA price-entity branch and from `static_status()`, both on the 30 s tick, and the plan's own sentence reaches `_LOG.info`. The doc now says what an operator can see (the Price history row, the Arbitrage row's own refusal sentence, the refresh log line) and a check pins the PAIRING - wiring the plan into the row is fine, correcting the doc is fine, doing one without the other is red. * L11. "fills EVERY unpublished hour" is conditional: a partial yesterday leaves the local hours it never held out of the series (§11.4 for those hours, and `at()` raises rather than answering). Correct behaviour, overclaimed wording, and untested - all three fixed. * L12. DECISIONS §1 leaned on `TariffPlan.cheap_now()`, which has NO PRODUCTION CALLER on the provider plan (`self.cheap` comes from `static_status()`, which builds its own). The conclusion holds on `arbitrage()`'s firm-pair refusal alone, which does reach control; the evidence is now stated at the reach it has. * L13. §1's "passed through by identity" check compared `eur_per_kwh` between two SEPARATE `resolve_tariff()` calls, where `is` could never have held. The value comparison is kept and now says what it grades; identity is graded on a read the file constructs and still holds. * L17. `PriceHistory.words` and the new status row had no check at all - and `words` is one of the two things H2 crashed. Both now have one. * L18. main.py's inline note carried the "widens what the optimiser can SEE, never what it may act on" guarantee without the windowing caveat that the CHANGELOG, DOCS and `resolve_tariff()`'s docstring all carry. It is the one place a maintainer reads it unqualified. EVIDENCE. All eight reviewer proofs re-run: p1/p1b return 29 March, p4 keeps 60 of 60 firm points at spread 0.134, p5 starts and reports, p6 D leaves no temp, p6 E refuses 1.0, p6 F records nothing, p7 returns 48 for 48. p2's script still scores True/True because it re-implements the OLD algorithm - the reversal is now driven as a mutation instead, and is red. p3's script always showed the shipped code correct; what was wrong was the fixture, and its mutant is now red. Twenty mutations driven, no survivors, tree fingerprinted and `__pycache__` purged before each: decimation (2 suites red), audit x3, unfloored `until` (2), unvalidated day records (7 checks), instant-subtraction yesterday, in-memory fill on a volume-less store, clock-arithmetic prune, cap without the pin, leaked temp, loose schema type, empty `words` (5), reversed `carry()` (2), a `_remember` leak in tools/ spelled two ways, a neighbour-filling fallback, a copy instead of identity (2), the DOCS claim in both directions, and the caveat removed from main.py. Baseline and the unmutated tree both green. No option added, config.yaml untouched, and the CHANGELOG entry still picks no version: PKG-07's rule, and only the deployer knows whether 0.9.0's image has been pulled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
0618194d9c |
FCST-04: the carry-forward fill reaches the plan, and the day it carries survives a restart
checks / unit (pull_request) Successful in 7m11s
FCST-03 shipped `fill_from_yesterday()` complete and checked, and shipped the consumers written for it - `TariffPlan.firm_points()`, `cheap_now()`'s refusal of a provisional hour, and `arbitrage()`'s refusal 3, which drops provisional hours from the trade set rather than refusing the whole series. It shipped NO CALLER. Nothing in `app/` named the fill, so no series ever contained a carried point and every one of those consumers was exercising its all-firm branch. ⚠️ THE DEFECT THAT PRODUCED WAS NOT AN ERROR ANYWHERE. `load_prices()` returns what the feed published and nothing widened it to the requested horizon, so on a dynamic site between midnight and the 14-16 h CET publication the plan covered the rest of today and nothing more - measured on the fixture here, 24 h against a 48 h request. `arbitrage()` then took `max - min` over that truncated window and reported a spread. The number was real, the window was half the one configured, and nothing said so: tomorrow evening's peak, the hour a morning charge would be sold into, was not in the series to be compared against anything. A missing hour is not a wrong price - it is an hour the optimiser never learns exists. WHAT THIS ADDS. `app/price_history.py` keeps the PUBLISHED prices of the last KEEP_DAYS Brussels days in /data/price_history.json; `resolve_tariff()` gains a required keyword-only `history` and fills every unpublished hour of the horizon from yesterday's same-wall-clock hour, flagged. Persistence rather than a variable on the refresh task, because the window the fill exists for is midnight -> publication and an add-on restarted at 08:00 would otherwise spend all of it on the truncated series. Not in state.json: the refresh runs every 1800 s and that file holds the maintenance history and SAFETY-02's latch. ⚠️ ONE CHANGE HERE MOVES ENERGY, AND IT IS NOT THE ONE THE CARD IS NAMED FOR. Carried hours are provisional, so §8.3 keeps them out of the trade set: the fill widens what the optimiser can SEE, never what it may DO, and test_price_history.py checks that so it cannot be overclaimed later. What does change a trade is that the filled series is windowed to [since, until), so hours that have ALREADY ELAPSED are no longer in the spread. Before, a cheap night that had gone sat in the series as the day's cheapest hour - and a cycle cannot buy in an hour that is past, so the trade was quietly never taken. Section 2 grades this by finding the cheapest firm hour with and without the fill and showing it MOVES, from 02:00 UTC to 08:00 UTC on the fixture. ⚠️ A DEAD FEED IS STILL §11.4, NOT YESTERDAY. The fill runs only on a `series` read. The two are indistinguishable to the optimiser - both 100 % provisional, so arbitrage refuses on the firm-pair rung and `cheap_now()` is False - so preferring yesterday's feed over the `static_profile` an operator configured FOR that case would change a documented degradation for a difference only the status page can see. That, and two more, in DECISIONS/FCST-04-the-day-that-is-carried.md. ⚠️ THE ANTI-DECAY RULE IS AN ORDERING, NOT A VALIDATION, and saying so is more useful than a guarantee that would not hold. Feeding the filled series back in is how this rots - day 2 carries day 1's guesses, day 3 carries day 2's carry of them, behind a `provisional` flag that stays TRUE while the NUMBER decays. No value-level check can catch it: a carried point and `eneco_eddy`'s published-provisional quarter are the same three fields with the same flag. So `carry()` is the only public entry, it records BEFORE it fills, the filled series exists only as a return value the object never sees again, and test_price_history.py walks app/ for any other module naming `_remember` and reads `carry()`'s AST to pin the order. EVIDENCE. 29/29 test files pass in the CI image. Eight mutations driven against app/price_history.py and app/static_tariff.py, __pycache__ purged before each run per MUTATION.md/TEST-15: newest-record lookup (5 red), recording the filled series (1), replace-instead-of-merge (10), UTC-date keying (10), removing the fill call entirely (12), a lost price field defaulting to 0.0 (2), prune by clock arithmetic (1), a degraded reason that stops naming its cause (1). No survivors; baseline and revert both green. Three of those first crashed the harness instead of reporting a FAIL - "it was refused" and "it broke on the way to being refused" must not grade the same - so `why()` and `_priced()` were added and the run repeated. No option added, config.yaml untouched, and the CHANGELOG entry deliberately picks no version: PKG-07's rule, and only the deployer knows whether 0.9.0's image has been pulled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f6d7bfcb04 |
SAFETY-44: give the moved-not-lost branch a control that reaches it, and make the move injective
checks / unit (pull_request) Successful in 7m38s
⚠️ THE CONTROL I WROTE LAST ROUND WAS INERT, AND REVIEW MEASURED IT. M12 ran its
mutant over `state-legacy.json` and the findings diff against the UNMUTATED tree
was EMPTY. It "passed" because that fixture's STAGED leg is already exit 1 on
pre-existing litter, and `"migrated unit/shed/" not in out` was trivially true
because a pre-DEV-02 FLAT store has no shed latch to lose - after migration only
the FIRST roster entry is ever latched.
The decisive measurement is the one it could not make: reverting the
`vanished_unit not in after.units` narrowing - restoring exactly the rule that
hides a real latch loss - left 28/28 GREEN.
⚠️ SO IT WAS HABIT 4 WEARING THE CLOTHES OF ITS OWN FIX, AND WORSE THAN THE
"NO CONTROL" IT REPLACED, because it reads as checked. That is this commit's
own argument about the M3 mis-citation, turned on the thing I wrote to answer it.
⭐ THE FIXTURE CAME FIRST THIS TIME. `state-both-latched.json` is a store at
SCHEMA_VERSION with `unit/garage/*` AND `unit/shed/*` both latched by ONE site
event, so the reasons match too - the arrangement in which same-value
suppression is most dangerous, and the one no existing fixture could produce.
M12's mutant then makes ONE roster unit's latch key VANISH while its sibling's
survives at the same value:
shipped tree, both-latched fixture exit 0, no findings
one unit's latch key deleted exit 1, ADDS
VANISHED STORE KEY unit/shed/sign_tripped
narrowing reverted ⚠️ RED (was 28/28 green)
And it asserts the PRECONDITION - the fixture is clean on the shipped tree -
plus that the mutation ADDS findings rather than coinciding with ones the
fixture already had. An empty diff there is exactly what made the last draft
inert, and nothing said so.
⭐ AND THE MOVE IS NOW INJECTIVE, which is the narrower hole review found still
open. `moved_to` is "any machine-read key with the same bare name and the same
value", and `DEFAULTS["sign_tripped"] is False` means `True` is the ONLY
non-default value a latch can hold - so N vanished keys could all claim the SAME
destination, by construction rather than by coincidence. Measured on a rename
carrying `inverter-a` -> `garage` correctly while DROPPING `inverter-b` -> `shed`:
migrated unit/inverter-a/sign_tripped = True -> unit/garage/sign_tripped
migrated unit/inverter-b/sign_tripped = True -> unit/garage/sign_tripped
Zero store-key findings, on a run where `shed` came up UNLATCHED. Two keys
cannot both have become one key. `diff()` claims each destination once.
⚠️ AND THE CHECK FOR IT IS ANCHORED TO A RUN THAT ACTUALLY PRODUCES MIGRATED
LINES. A dedicated mutant was written first and asserted over an EMPTY list -
vacuous, passing, indistinguishable from working, the same defect twice in one
sitting. These fixtures cannot produce two claimants (`migrate_unit_keys()`
moves FLAT keys only, so one flat latch yields one migration), so rather than
build a fiction to grade, injectivity is asserted over part 5's real migrations,
with a PRECONDITION that there are at least two of them. THE TWO-CLAIMANT
ARRANGEMENT IS A STATED RESIDUAL: bounded in `diff()` by construction, not
measured end-to-end.
Finding 4, and my correction to it was also wrong. The comment cited "line 315"
and "two hundred lines below"; the fix I wrote said "~54 lines down", which was
review's distance to the WRONG line, carried to a new referent without
re-measuring - inside the sentence apologising for a wrong number. Recomputed at
|
||
|
|
d1b7e3f113 |
SAFETY-44: decide per key, because one shared flag let an unrelated latch veto the repair
checks / unit (pull_request) Successful in 6m58s
⚠️ REVIEW DEFEATED THIS CARD'S OWN FIX WITH ONE ADDED KEY, and the project's own instrument agreed on the unmodified tree. The guard classified each key and then wrote ONE site-wide `namespaced_latched` for BOTH "on the roster" and "off-roster but not UNIT_A", so a single latched key belonging to a unit the operator had removed from `inverters:` vetoed the repair of the misdirected `inverter-a` latch beside it. Measured, roster ['garage','shed'], store stamped so the migration fix cannot reach it: sign_tripped + unit/inverter-a/sign_tripped -> [('garage', True), ...] ...AND unit/old-shed/sign_tripped -> ⚠️ [('garage', False), ...] A site DRIVING on a state file that reads `sign_tripped: true` - the sentence in this card's own first paragraph - and `tools/rehearse_roster.py` printed `LATCH CAME UP DISARMED` on it, exit 1, against shipped code. It matters more than a normal hole because this guard is, as main.py says, the ONLY repair path for an install already stamped by 0.9.0. ⚠️ AND IT IS INSTANCE #17 OF HABIT 4, IN THE EXTENSION MUTATION.md ADDED TWO DAYS AGO. The two fixtures written for this card each hold ONE arrangement - `_staged_store` has only `inverter-a`, `_other_store` only `inverter-b` - so the flag was never written twice with opposite intents in a single store. A per-key check whose keys have never disagreed WITHIN ONE STORE is a check over whichever key came last. Three variables now, one per case, and a fixture holding BOTH. Four cases driven: stranded-only repairs, +1 unrelated repairs, +2 repairs, off-roster-only does NOT (which is DEV-02's control, still green). ⭐ AND THE MOVED-NOT-LOST RULE HID A GENUINE LATCH LOSS. The match was bare key plus value over the whole of `machine_read`, with no identity - and `DEFAULTS["sign_tripped"] is False`, so the ONLY non-default value a latch can hold is `True`. Any surviving latched roster unit therefore suppressed any other unit's vanished latch. Review measured a build that drops `unit/shed/sign_*` while `unit/garage/sign_*` survives, both latched by one site event so the reasons matched too: none in LEG SAME-STEP: nothing vanished, nothing stranded ... NO FINDINGS in the rehearsed transitions exit 0 A roster unit's persisted SAFETY-02 latch deleted, transition reported clean. The legitimate case is a RENAME - the key left `inverter-a`, which is not on this roster, and arrived under `garage`, which is - so the vanished key's own unit must be OFF the roster. A key whose unit is still on the roster has not been renamed, it has been lost, and no amount of the same value elsewhere makes that untrue. ⚠️ AND THE BOUND I CITED FOR IT DID NOT EXIST. Both the comment and the last commit message said "what M3 (delete the flat rollback view) measures". M3 is not that mutant - it drops `sign_reason` from `LEGACY_UNIT_KEYS` - and the one I meant, M9, vanishes only FLAT keys, so neither can satisfy the `unit/` gate the rule sits behind. NEITHER EXERCISED THE BRANCH; it had no negative control at all, in a card whose subject is checks that cannot reach the failure they name. A citation is the worst carrier for that, because it reads as having been checked. M12 is written for it and driven: a roster unit that stops restoring its latch is exit 1, and the suppression does not swallow it. `misdirected` IS UNREACHABLE FROM THE CALL SITE, and the claim that it was a benefit is withdrawn rather than restated. `unit` is `roster_names(opts)[0]` and `build_roster()` names its first entry from the same list, so `unit` is a member of `roster` by construction; review measured it - dropping the `roster` argument inside `migrate_unit_keys()` survives 28/28. The argument stays for the reason `_verify_moves()` gives for its own `roster=None` branch, it is what a NEW caller gets - and a guard nothing exercises is a guard nobody knows works, so it is now exercised at the function's own level: a wrong `unit` comes back misdirected, the marker is not stamped, and the same call with a roster name stamps it. Dead `if _roster_names else UNIT_A` removed; `roster_names()` never returns []. THE OPERATOR MESSAGE IS ASSERTED. Review deleted it whole (`if stranded:` -> `if False:`) and 28/28 stayed green - `stranded` had no other consumer, so the list existed only to print a line nothing checked, and that line is the entire operator-facing half of the repair. Now: exactly one SAFETY-44 line at ERROR, naming the stranded key and the roster it was measured against. A wrong line citation removed: the call-site comment said "line 315's comment" and "two hundred lines below", and both were wrong (315 is the CFG-03 defaults note; the comment meant is ~54 lines down). Cite the thing, not its coordinates. ⚠️ AND WHAT 5b/5c ACTUALLY PIN IS RECORDED, because review is owed the distinction: `mutant_tree()` asserts its target exists, so EDITING the guarded line makes the file red at the ANCHOR before any behaviour is measured - which looks identical from the exit code and proves much less. It happened twice while writing this commit. The behavioural coverage lives in test_maintenance.py section 13 and test_inverter.py, which build stores rather than strings. Fixture strings no longer say "measured" - they are synthetic, and the repo's other fixture carries an explicit SYNTHETIC header. 28/28 files pass. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
5e382f52f6 |
SAFETY-44: the latch migration takes the roster, and the guard stops being defeated by the key the defect wrote
checks / unit (pull_request) Successful in 6m56s
⚠️ A DISARMED SAFETY-02 GUARD ON AN INSTALL WHOSE STATE FILE SAYS IT IS PROTECTED. `Controller.__init__` called `migrate_unit_keys(store, UNIT_A)` - a hardcoded constant - while its sibling `migrate_maint_keys(store, unit, roster)` takes the roster and refuses a write no machine reads. On a store that ran pre-DEV-02 flat and declares `inverters: [garage, shed]`, the latch moved to `unit/inverter-a/sign_tripped`, `_verify_moves()` read it back under the name it had been HANDED, was satisfied, and stamped the marker. Not one inverter came up latched, and the next start skipped the migration too. That is the MAINT-05 defect verbatim, still live in the function whose own docstring describes it, and `_grade_store_migration()` did not catch it: its "is anything namespaced latched" test was satisfied BY THE MISDIRECTED VALUE ITSELF. ⚠️ THE REASON IT WAS LEFT WAS A HALF-TRUTH. "There is no roster yet - the `Inverter`s restore their latch in their constructors." The KEYS must be written before the `Inverter`s read them; the NAMES do not come from the `Inverter`s. `roster_names(opts)` reads them off the options before anything is constructed - which is exactly what it already existed to do for `MqttPublisher` - and returns `[UNIT_A]` on the flat shape, so today's upgrade path is byte-identical. TWO EDITS, AND THEY DO DIFFERENT JOBS. Measured per leg by reverting each one: SAME-STEP leg STAGED leg both edits (shipped) clean latch armed, litter reported guard reverted latch armed ⚠️ DISARMED call site reverted latch armed, litter latch armed, litter So the GUARD carries the safety and the CALL SITE carries the hygiene and the withheld marker. The table is in test_rehearse.py part 5 because a reader who assumed the roster-aware migration re-arms the latch would delete the guard as redundant in a tidy-up and take the STAGED column with it - and STAGED is what "upgrade now, declare the roster later" produces, which is the path an operator actually takes. Only the guard reaches an install already stamped by 0.9.0. ⚠️ AND "OFF THE ROSTER" ALONE WAS TOO BLUNT, WHICH test_inverter.py CAUGHT. The first draft treated every off-roster latch as litter. In DEV-02's restart case the store carries `unit/inverter-b/sign_tripped = True` from B's own trip while the roster being graded holds only A - and the blunt rule re-armed a HEALTHY A off the flat key B's trip had mirrored. DEV-02's defect rebuilt inside its own guard, which is what the paragraph I was overruling had been right to fear. Narrowed to `UNIT_A`, which is the only name the broken migration ever wrote - `roster_names()` falls back to a POSITIONAL `inverter-N`, so `inverter-a` is not a name this code hands to anyone else. A latch stranded under any other name is a real unit out of today's config and still counts as protection. Residual, stated in the code rather than left to be found: a site whose own first unit is NAMED `inverter-a`, latched, then taken out of the roster gets re-armed on `inverters[0]` - a healthy unit held at 0 W until an operator clears it. The conservative direction, against a site DRIVING on a file that says it is latched. ⭐ AND FIXING THE CODE EXPOSED A FALSE POSITIVE IN THE HARNESS. With the latch now landing under `garage`, `rehearse_roster.py` reported VANISHED STORE KEY for `unit/inverter-a/sign_tripped` three lines above the same value sitting under `unit/garage/sign_tripped`. A key that moved to a namespace a machine reads has not vanished - and an alarm that fires on the harmless case is one an operator learns to dismiss before the real one arrives, which is CONTROL-C's own argument. The test is not "the name appears somewhere": same bare key, same value, under a key in `machine_read`, the set built by driving a real start. A latch that genuinely went missing has no such key and is still a finding, which M3 (delete the flat rollback view) still measures red. Test parts replaced deliberately, as both of them asked to be: - test_rehearse.py part 5 asserted the defect "as REQUIREMENTS so that a fix turns them red". It now asserts the fix, with 5b and 5c as negative controls - one per edit - and 5b doubles as the leg-splitter's positive control, since reverting the guard is the build where the two legs DISAGREE. - test_maintenance.py section 13 was headed "RECORDED, NOT FIXED" and said the fixing card "should expect them to go red and should replace them". Replaced, plus two cases it could not have had: the already-stamped store, and the `inverter-b` negative control for the narrowing above. 28/28 files pass. Not run: nothing - this is host-side only, no rig, no hardware. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f8e501393f |
OPT-09: the weights parameter nothing ever passed, and what it cannot do
`allocator.plan()` has taken a `weights` argument since ALLOC-01 and NOTHING
had ever passed one - main.py called `resolve()` without it and the arbiter
defaulted it to 1.0 per unit - so the site target was split 50/50 regardless
of what either pack could do. Two things now feed it, and they are different
kinds of thing:
* a `pack` UNIT claim at P_SAFETY that CLOSES a unit's envelope at its own
`bms_soc_floor` or at 100 % - a PERMISSION, obeyed absolutely, so an empty
pack is not asked to discharge and its share goes to the sibling;
* SoC-aware weights by ENERGY headroom in kWh - a PREFERENCE, which
`_fill()`'s last-resort pass will override the moment the sibling saturates.
Measured (test_packshare.py part 8): at a load one pack cannot cover, the
weighted arm and the shipped arm command the IDENTICAL watts into an empty pack
and deliver the IDENTICAL watts. Only the envelope stops the ask, and what it
buys is not delivery - it is a reported `unmet_w` where the record used to read
impeccable. Weights are a comfort choice for STABILITY and NOT for DELIVERY.
Also: an optional per-entry `capacity_kwh` (schema change, all-or-nothing across
the roster, rule 9 refuses a partial one); per-pack arbitrage sizing, with the
sell side's no-op stated rather than hidden; and a 0 W trade refused by name,
because a 0 W arbitrage claim is a park order that outranks the loop.
SAFETY-42 and this card meet at one hazard from opposite sides - OPT-09 stops
the site ASKING a pack whose SoC says it cannot deliver, SAFETY-42 alarms when a
pack that said it could does not - and its end-to-end fixture moved as a result.
Its finding is unchanged and is now stated on the two quantities its rejected
discriminator actually reads.
Not filed at all at a roster of one: at N=1 every source routes to the site, so
the interval would bound the SITE TARGET, and SAFETY-25's decided Option A
stands untouched on the live install.
⚠️ INVERTER B DOES NOT EXIST. Its 4600 W / 20.48 kWh / 10 % are FROM DATASHEET
AND SERIAL, and `sim/plantsim.py`'s INVERTER_B is inverter A copied
(`measured=False`), so every two-inverter figure here is arithmetic or two
copies of A. No hardware was touched.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
090a8ecc35 |
SAFETY-42 round 2: pin the two thresholds at a config that is not the shipped one
checks / unit (pull_request) Successful in 6m7s
THE BLOCKER. At the `delinquent()` call site, `self.tuning.saturation_w` -> `250.0` (-19 B) was a survivor of all 23 suites. It is not an equivalent mutant: two copies of inverter A, B wedged, `saturation_w: 1800` (inside its own schema int(100,2000)) and a load of 1600 W put B's shortfall strictly between the literal and the configured value - head names nobody, the mutant names B. At the shipped 500 both name it, which is exactly why every fixture in part 4 was blind: their gaps are all above both thresholds. It matters beyond a mutation score. `delivery.py`'s MIN_W_IS_SATURATION_W note and the `delivery_hold_s` block in config.yaml both promise an operator, in shipped prose, that there is no fourth copy of a threshold to keep in step and no way for the two to drift - raise `saturation_w` and this check moves with you. A literal at the call site removes exactly that promise, silently, and the promise is why the design was chosen over a `delivery_w` key. ASKING THE SAME QUESTION OF EVERY OTHER NUMBER THIS CHECK READS FOUND A SECOND SURVIVOR OF ALL 23 SUITES: `bms_floor=inv.bms_soc_floor` -> `10.0` (-13 B), invisible because config.yaml's own example states 10 % and every fixture in this file used it. Two arms bracket it: a pack at 15 % against its own 25 % cut-out is cold and must stay unnamed (the literal names an empty pack), and a pack at 8 % against its own 5 % cut-out is wedged and must be named (the literal explains the fault away). One arm on each side leaves no constant at all. `delivery_hold_s` and `is_live()`'s window were ALREADY pinned - the fixtures had to move them to run - and `LINK_STALE_S` has no option behind it, so "pinned across a changed config" is not available for it and is not claimed. DECISIONS section 9 enumerates all of it with the deltas and which check kills which. Verified in the CI image, tree mounted :ro, `python3 -B`, `__pycache__` purged and counted before every run (TEST-15): R5 saturation_w -> 250.0 -19 B killed by part 4b(a) R6 bms_soc_floor -> 10.0 -13 B killed by part 4b(b), both arms R7 arm(self.delivery_cfg) -> DeliveryConfig() -1 B killed (already) R8 is_live(now) -> is_live(now, 3600.0) +8 B killed (already) R9 pack cut-out -> conjoined site floor +105 B killed twice head: 23/23 test files PASS, no bytecode written during the run. No shipped behaviour changes: the only edits to app/ are comments. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
706e625d99 |
SAFETY-42: a unit that stops delivering, and the discriminator the card asked for does not exist
A unit standing at a non-zero share and producing nothing is seen by NOTHING. SAFETY-30's per-unit sign gate needs OPPOSITION on both sides of 250 W and a unit at 0 W is not opposing, it is ABSENT. The site sum still agrees with the meter in direction. Circulating power is exactly zero when one unit does nothing. The only trace left is `reason == "saturated-freeze"`, which clamp.py:93-96 documents as the alarm an operator learns to ignore. It is HW-01's shape, which ran 6 h 25 m with all three layers spectators. ⚠️ THE CARD'S OWN DISCRIMINATOR WAS BUILT FIRST AND FALSIFIED, AND THAT IS THE MAIN CONTENT. SAFETY-42 asks for "saturation persisting past N while |grid error| > X, both derived". Run on the two-master rig it fails in BOTH directions, and no (N, X) fixes either: FALSE POSITIVE `plantsim.Plant.limit()` returns 0 W for a discharge command into a pack at its own floor, and a wedged unit produces 0 W too. Load 2000 W, equal weights, 2000 W per-unit cap, 120 cycles: THE TWO ARMS ARE IDENTICAL ON ALL 120 in grid, site target, every share and every measured watt. Both saturated-freeze on 116 of them, both hold |grid error| over 300 W on all 120 and settle at 1200 W, both read circulating 0.0 W. The predicate's inputs do not differ, so no threshold on them can differ. And "a cold pack at its floor must not alarm" is the card's own AC 2. FALSE NEGATIVE the standing grid error is what a HEALTHY SIBLING ERASES. Load 800 W, same config, B wedged: over the last 30 of 200 cycles the loop is frozen on 30 of 30 while the worst |grid error| is 30 W, with B standing at +770 W and delivering 0 W. Any X above 30 W is silent for the whole run on the exact fault the card describes. WHAT REPLACES IT. Per unit, for a discharge share, `share - measured`; readable because of a reduction that only exists at N>=2: a unit is named while it is short by more than `saturation_w` with NO ACCOUNT for it, and the units in that state are a PROPER SUBSET of the units asked to discharge. THE ACCOUNT keeps the cold pack out and is the only thing that can: the two cases are identical in the power domain, so the discriminator has to be a non-power fact, and there is exactly one - the pack's own SoC against its own `bms_soc_floor`, asked through `peakguard.discharge_permitted()` rather than transcribed. ⚠️ `bms_soc_floor` ALONE, not `pack_floor_pct()`'s conjunction with `peak_soc_floor`: that floor bounds a money-saving discharge only and using it would explain away a wedged unit anywhere between the two. THE PROPER SUBSET keeps a whole-site cause out - a derate this add-on cannot see hits every unit; one box that stopped listening does not - and it is what makes this INERT AT N=1, by algebra rather than by a roster guard. IT REPORTS. IT DOES NOT ACT, and the strongest argument is for acting. Dropping the wedged unit from `live` genuinely recovers a site the shipped path does not: at load 1500 W, kept in the split the site settles at 800 W with a 700 W error and NEVER comes inside 100 W in 150 cycles (the freeze pins the target, so the sibling's SHARE never grows); dropped, it delivers 1500 W from cycle 14. What refuses it is that the only re-allocation this add-on can express is all-or-nothing: a unit derated to 50 % is short by more than saturation_w with nothing to explain it, so this detector names it too, and at load 3000 W dropping it leaves the site delivering 2000 W against 2400 W kept - 400 W WORSE. A partial re-allocation is what would make acting safe and the allocator cannot express it. That is a card. control.py is NOT MODIFIED. The freeze shapes the loop; this reports on it. NUMBERS, MEASURED. The watts side is `Tuning.saturation_w`, read at runtime, so there is no fourth CFG-03 copy and it cannot drift from the number the control law itself calls "not following". `delivery_hold_s: 185` comes off 2640 closed-loop two-inverter runs in which nothing is faulty (6 gains x 5 slews over the whole schema range, across load reversals, a flapping load and ASYMMETRIC SPLITS - a family SAFETY-30's campaign did not have and the one that dominates here) plus 1890 runs at a roster of ONE as the control: threshold reversals flapping weighted N=1 control * 500 W 20.0 s 0.0 s 30.0 s 0.0 s The N=1 column is 0.0 s at EVERY threshold in all 1890 runs, and the flapping column - the family that defeated SAFETY-30's site window - is zero too, because a common stimulus makes both units short at once and the subset stops being proper. ⚠️ The curve is NOT monotone (55.0 s at 250 W against 40.0 s at 100 W): lowering the threshold can turn a proper subset into the whole roster and BREAK the run. ⚠️ THE MARGIN IS MEASURED, NOT FELT, BECAUSE INVERTER B DOES NOT PHYSICALLY EXIST. `plantsim.INVERTER_B` is A COPIED, `measured=False`, so every two-inverter figure above is two copies of A. Sweeping a different second unit: the worst legitimate episode is insensitive to B's RAMP (30.0 s at half A's) and scales with its LAG - 45.0 s at twice A's measured 10 s, 90.0 s at four times it. 185 s is 6.2x the measured worst, 2.06x the four-times-slower case, 6.2x LINK_STALE_S and 4.9x inside the 900 s quarter. Deliberately not 180, which is SAFETY-02's site hold. SAFETY-34. `unit/<name>/delivery_tripped` in the store, one notification id per unit, re-raised on the first cycle of every process, cleared by the Start press. No flat mirror: a rollback lands on a version that drives one actuator, where this check is inert. ⚠️ SCHEMA CHANGE - `delivery_hold_s` joins options: and schema:, so this needs a version bump before it ships. Additive and defaulted, so an existing options blob stays valid. STATED GAPS: charge shares are not graded (no configured charge ceiling exists, so a constant-voltage taper cannot be explained and arming it would fire on every maintenance charge); every unit wedged at once is not caught (the subset is not proper and no instrument here separates that from a plant that cannot). Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
6864109a01 |
SAFETY-37: a stale reading is None, and arrival cannot be what says so
checks / unit (pull_request) Successful in 5m34s
The architect pass made SAFETY-37, TEL-06 and TEL-08 one systemic problem - "a stale reading holds its last value and reads healthy" - and this builds the single policy. Both consumers the card names are gated by one change, and neither consumer needed a line: `SignWatchdog.evaluate` already CLEARS its window on a None measurement and `circulating_w` already returns None for a roster with a missing term. Neither could ever receive one. The gate is the piece that was missing BETWEEN the shipped read and the shipped checks. ⚠️ ONE CRITERION IN THE CARD COULD NOT BE IMPLEMENTED AS WRITTEN, AND SAYING SO IS THE MAIN CONTENT. The card says "only arrival separates them". At this layer arrival cannot: `read_inputs()` polls Home Assistant's state cache about once a second and HA answers 200 with a number whether or not the publisher behind the entity is alive, so both members of the pair arrive identically for ever. test_freshness.py part 1a BUILDS the arrival-age gate the card asks for and grades it failing - the age is 0.0 s at every instant of both runs, a threshold that can never fire, which is TEL-06's own defect one layer up. The half of the rule that survives is honoured absolutely: nothing here reads a Home Assistant timestamp, and the check asserts the module contains no `last_updated`. So the criterion became: a reading is stale when it has not moved through a change it was OBLIGED to follow. STALE <=> unchanged >= 35 s AND |standing| >= 250 W AND |standing - standing when the reading last changed| >= 250 W Latched until a different value arrives. `Inverter.batt` becomes None - never a held number - which is a missing input, which §11.1 rule 1 answers with 0 W. WHY A CONJUNCTION AND NOT A THRESHOLD, MEASURED 2026-09-06. Replaying the committed 30-day capture of this house's own 1 W power entity (485,841 samples out of HA's recorder, where a row exists only on a CHANGE, so the gap between rows IS the unchanged duration every consumer saw): the longest legitimate unchanged run is 263.2 s, held at -899.0 W. A false-positive-free threshold would have to exceed that, and 263 s is 3.5x too slow for a consumer that trips at 75 s. There is no admissible threshold. Every one of those long runs is under an UNMOVING load, which is what the travel term keys on. THE BOUND, derived at both ends and graded against the shipped config.yaml. Floor 17.0 s = 6.0 plant settle (NOTES §5.9, measured 2026-08-22) + 10.0 ESPHome publish (firmware/goodwe-master.yaml:181) + 1.0 read period (run_control's asyncio.sleep(1)). Ceiling 75.0 s = min(circulation_hold_s 75, unit_sign_disagree_s 85). Band [34.0, 37.5]; 35 is a CHOICE inside a DERIVED band and the check says so - the first draft claimed the band held one integer and went red on its own first run. MOVE_W is the LARGEST admissible value, unit_sign_disagree_w, because below it the consumer cannot speak at all. SoC is STATED, NOT WIRED, and BOUNDS carries it with wired=False and the reason. Its obligation term is energy through the pack, not command travel - a rested pack holds a percent for hours under a 0 W command - and K needs a usable capacity nobody has measured. That is TEL-08's; the record says so. ⚠️ BEHAVIOUR CHANGES AT THE SHIPPED ROSTER OF ONE, and it is named rather than hidden: a FROZEN register now stops the site where it used to read as a healthy measurement for ever. That is HW-01, which was a one-inverter site. A healthy install is unchanged, asserted over sixty reads of a dithering register under a reversing command. A false verdict fails toward 0 W behind the existing stale_input_s hold and clears itself on the register's next move. ⚠️ BOTH UNITS IN EVERY TWO-INVERTER FIXTURE ARE INVERTER A with different numbers passed in; inverter B does not physically exist (~2026-09-12). MUTATION: 16 mutations against a purged, :ro, python3 -B tree, fingerprinted before and after every revert. One survivor, and it is the finding - dropping the magnitude term left every check green because no fixture separated "the command travelled 250 W" from "the command ended up above 250 W". Closed, and recorded as MUTATION.md habit 17. A second process defect is habit 18: a mutation run that timed out between the edit and the revert left the module mutated on disk and nothing announced it. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
5d7e275df4 |
SAFETY-39: slew_w is a ratio to the rail, and gain is what is still wrong
checks / unit (pull_request) Successful in 5m16s
`slew_w: 1000` was derived on 2026-08-22 against a clamp of 1500 W, where "capping how far the loop can jump ahead of the inverter" was true because the rail itself bounded the excursion. The live install went to max_w 5000 and the constant did not move, so the loop crosses its whole output range in 10 s against a plant NOTES.md §5.10 measured at ~18 s. Measured on the owner's system 2026-09-05 11:43-11:46: a 3.4 kW export drove the setpoint 380 -> 5000 W in five 2 s ticks, the battery to -5154 W past a 5000 VA rating, and the grid from 3.4 kW of EXPORT to 2.8 kW of IMPORT. Nothing was broken; the rail moved. REPRODUCED FIRST, and one half of it is not reproducible at all. On plantsim.Plant and on an independent in-repo model: the setpoint stepping a full 1000 W per tick to the rail (48 of 51 export steps), and the meter crossing from export into import. The -5154 W figure is NOT reproducible in either model, because both clamp the plant at its rating - so the card's AC "battery no longer exceeds max_w in simulation" is unfalsifiable and was rewritten rather than met. THE DELIVERABLE IS THE RELATIONSHIP. SLEW_RAIL_FRAC = LOOP_TICK_S / PLANT_SETTLE_S = 2 s / 18 s = 1/9 slew_w = 0 now means FOLLOW THE RAIL - SLEW_RAIL_FRAC * max_w - exactly as integrator_max_w = 0 already means follow max_w. It is the shipped default: 222 W at max_w 2000, 556 W at 5000, 1067 W at a ~9600 W two-inverter site. validate.py rule 10 refuses an explicit value faster than that, graded against sum(unit_caps(opts)) - the roster sum, i.e. Controller.site_max_w - so a second inverter moves the bound with no operator action. VERIFIED BY BREAKING IT: restoring slew_w 1000 at max_w 5000 is refused, and the refusal names the rail, the crossing time, the measurement and what to do. Equality, one watt of slack, the live interim 400 and slew_w 0 at every rating all still start. GAIN IS THE CONSTANT THAT IS STILL WRONG, and it is NOT changed here. Over 51 export steps the over-absorption is FLAT in slew (958 W at 1000, 1081 W at 250) and monotone in gain (987 W at 0.6, 876 at 0.3, 435 at 0.2): slew_w bounds the OUTPUT, while the integrator moves gain*error per cycle and reaches a 5000 W rail in under three ticks whatever the slew is. Two control-law constants moving in one release on a running house makes the next measurement uninterpretable. ⚠️ N=2: the site rail becomes sum(max_w) ~ 9600 W (inverter B FROM DATASHEET AND SERIAL, not measured, and sim/plantsim.py's INVERTER_B is A copied), and the enforced ratio produces 1067 W there automatically. But a growing rail LOOSENS this bound, and the >= 900 W symptom goes stale at N=2 the same way the constant did - both stated in the record rather than left to be discovered. Nothing reached the inverter. The live install still runs the interim slew_w 400 applied by hand on 2026-09-05, which rule 10 accepts unchanged. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
26c5ee8adc |
TEL-07: a second MQTT device for inverter B, and A keeps the one it has
checks / unit (pull_request) Successful in 4m58s
MQTT discovery announced ONE device and hung every entity off one unique_id prefix, so at two inverters B's per-unit telemetry had nowhere to go. It has somewhere now, and not one entity that already exists moved. ⚠️ THE ASYMMETRY IS DELIBERATE. The first roster entry's per-unit rows are announced on THE DEVICE IT ALREADY HAS; every later entry gets its own device, via_device the controller. "One device per inverter" is tidier and is the change that renames every entity on the live install - and because HA keeps the id it composed at FIRST discovery, a rename produces a NEW entity beside a DEAD one: the history stays behind and every dashboard, template and automation naming it goes on pointing at a sensor that quietly stopped updating, including the three live watchdog automations. The composed ids come out symmetric anyway (sensor.goodwe_inverter_a_battery_power / ..._inverter_b_...), so the tidy design's only real benefit is bought here without its cost. * four per-unit rows - setpoint, battery power, SoC, SAFETY-02 sign latch - announced only from a roster of two. At N=1 nothing is announced and nothing is published: no second device, no renamed entity, no added topic. * grid and p1_sample_age_s stay SITE-scoped and are announced ONCE, at every roster length 1-6. One P1, one grid connection, and p1_sample_age_s is a watchdog input - a second copy is a second answer to "is the meter fresh?". * inverter.roster_names() is the one answer to what the units are called, read by build_roster() and by the publisher, which must know the roster before a Controller exists because announcing happens on the CONNACK. * DECISIONS/TEL-07-second-mqtt-device.md records the two designs side by side. VERIFIED BY DIFFING THE ANNOUNCED PAYLOADS, not by reading the code. The release/1.0 baseline in test_mqtt.py was generated by running that commit's module, not transcribed. Roster of one: 9 topics, 0 missing, 0 changed, 0 added. Roster of two: 0 missing, 0 changed, 8 added. MEASURED, NOT ASSERTED. Sixteen mutations through tools/mutation_run.sh; twelve are in the file as a running table, each named with the property it breaks. Three of those properties exist because the table found their ABSENCE - dropping the unit from the state topic, moving `grid` into the per-unit set, and `units=()` in main()'s publisher call were all GREEN on the first run, as was a roster fallback naming two nameless entries `inverter-a`. Part 9 enumerates what the file still cannot see, with sizes. ⚠️ INVERTER B DOES NOT PHYSICALLY EXIST (~2026-09-12). Every roster of two here is SIMULATED, from the datasheet and serial in NOTES.md §1.1b. Nothing about B has been measured and no entity described here has been seen on a broker. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f9e7fbf86d |
SAFETY-32: bms_soc_floor per pack, rule 8 per unit
`bms_soc_floor` describes A BATTERY, not a site. At two packs of different models the cut-outs differ, and one number for both graded the shallower pack against the deeper one's BMS - so a site with cut-outs of 10 % and 30 % under `peak_soc_floor: 20` STARTED, and the guard would command a forced discharge that pack B's BMS, not the operator's floor, is the thing that stops. That is rule 8's own failure mode, reached through rule 8. Scoped to the card's third bullet, per its PM PROOFREAD: the aggregate anti-windup (DEV-02) and per-instance `achievable_w` (CFG-04) were verified as already shipped and are untouched. * config.yaml: `bms_soc_floor: int(0,50)` REQUIRED per `inverters:` entry. Nothing is inherited; the flat key stays the single-inverter shape's own cut-out. A per-entry DEFAULT was declined - a default is one number for every pack, which is this card's defect - and the decision is recorded. * inverter.py: `Inverter.bms_soc_floor`; an entry that states none gets None, not a borrowed number and not 0.0 (the most permissive value the key has). * peakguard.py: `Pack`, `pack_floor_pct()`, `pack_permissions()`, `binding_soc_floor()`. `discharge_permitted()` is unchanged and is still the one place the question is answered. * validate.py: `unit_bms_floors_indexed()` carries the ROSTER index; rule 8 grades EVERY unit and NAMES the one it refuses. Graded with the offender SECOND and with the same two numbers in the other order. * main.py: `Controller.packs`; `decide(soc_floor=...)` is the per-pack reduction of the same option; the floor-limited notification names the pack that stopped the site. `pack_floor_soc` - the emptiest pack, and its None-on-missing behaviour - is untouched. * tools/supervisor_shape_probe.py: RE-RUN and repaired. The required key broke §C and left §D printing PASS on a refusal about a different key. §D is now an isolated counterfactual over an accepted merged baseline, one key varied, asserting the key name. `all cases passed` on 2026.08.0. Stated rather than hidden: under any config rule 8 accepts the per-pack FLOOR reduces to `peak_soc_floor` for every pack. The reduction is written for `unit_caps_indexed()`'s reason and graded on both sides - 1775 rule-8-valid pairs answer the option, the pair rule 8 refuses answers the cut-out. `peak_soc_floor` is still one number for the site, so the "deeper pack needlessly withheld" half is filed as an open question, not closed. Full 19-file suite green. Twelve source mutations through tools/mutation_run.sh: eleven red, one argued survivor. The battery also found `_flat_bms_floor()` defaulting in two places, each covering for the other. No measurement of inverter B appears anywhere: it does not exist yet. Every second-pack figure is simulated and labelled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
65cddf35f1 |
MAINT-05 fix round: grade the migration against the ROSTER, not against the name it was handed
checks / unit (pull_request) Successful in 4m47s
REJECTED because a survivor undoes AC 5, and it survived for the recurring
reason: two fixture values that must be distinguishable were EQUAL.
THE SURVIVOR. app/main.py:282 mutated from `self.inverters[0].name` to `UNIT_A`
left the full 19-file suite green. `inverter.UNIT_A == "inverter-a"`, and every
two-pack fixture in test_maintenance.py named its first roster entry
"inverter-a" - so the two expressions were the same string in every check that
existed. main.py's own comment made the distinction load-bearing and nothing in
the repository could see whether that comment was true.
THE FAILURE IS REAL. `build_roster()` names a declared roster's entries from the
config and numbers a nameless one POSITIONALLY (`inverter-1`), so "inverter-a"
is not even the fallback. On ["garage","shed"] with a flat last_completed of
2026-08-07 the mutant migrates into unit/inverter-a/, pack 0 reads back None,
and both packs come up believing they have never been recalibrated.
AND IT FAILED SILENTLY, which was the worse half: `_verify_moves()` read back
the keys it had just WRITTEN, under the namespace it had just been HANDED, was
satisfied, and MAINT_SCHEMA_KEY was stamped - so the next start skipped the
migration too. A postcondition that reads back the namespace it was handed
cannot detect being handed the wrong one.
WHAT CHANGED
1. THE POSTCONDITION IS GRADED AGAINST THE ROSTER. `_verify_moves()` takes the
names the MACHINES read and reports a namespace that is not among them as
`misdirected` - a new, differently-named failure from `lost`:
* `lost` is "the store took the write and dropped it" - a storage fault,
with a harmless-default case (a dropped `last_completed: None` loses
nothing, because absent and never-recalibrated are the same statement);
* `misdirected` is "the store did exactly as it was told, by a caller that
was wrong". There is no harmless-default version of it - a write nobody
reads is not information whatever its value - so it fails `ok` alone.
`ok` gates the marker, so a misdirected migration is NOT stamped and the next
start re-runs it. Asymmetric on purpose: a re-run is recoverable (rule 1
makes it a no-op, rule 2 left the flat keys to recover from), a silent skip
is not. Part 9b MEASURES the recovery rather than asserting it.
2. `migrate_maint_keys()` TAKES THE ROSTER IN PLACE OF AN `n_units` COUNT. The
count was `len(self.inverters)` at the only call site, so the roster carries
it, and a count beside the names is a second opinion about how many packs
there are.
3. THE FIXTURES CAN NOW REACH THE FAILURE THEY NAME. Parts 9 and 11 run on
["garage","shed"], each behind a PRECONDITION check that the first name is
not UNIT_A - so an edit that makes them equal again goes red instead of
making the claims vacuous. Part 11's fixture date is relative to `now`, not
a literal, so "history preserved" and "history lost" cannot converge as the
file ages past `interval_days`.
MUTATION LEDGER - all red, purged tree, none at +0 B, full detail on the PR:
M1 main.py inverters[0].name -> UNIT_A -16 B 4 checks red
M2 store.py drop `roster=names` from _verify_moves -14 B 5 checks red
M3 store.py drop the misdirected.append -37 B 5 checks red
M4 store.py ok: drop `and not self.misdirected` -25 B 3 checks red
M5 fixture garage -> inverter-a (the trap itself) +4 B 5 checks red
M6 store.py parts[1] -> parts[-1] +1 B 1 check red
FOUND AND NOT FIXED - `migrate_unit_keys()` HAS THE SAME HOLE AND IT IS A LATCH.
It runs BEFORE `build_roster()` (each Inverter restores its latch in its
constructor), so it is handed the constant UNIT_A with no roster to grade
against. On a declared roster a pre-DEV-02 `sign_tripped: true` lands under
unit/inverter-a/sign_tripped, which no unit reads - and
`_grade_store_migration()`, whose whole job is to re-arm exactly this, is
DEFEATED BY THE KEY THE DEFECT WROTE: its "is anything namespaced latched" test
is satisfied by the misdirected value itself. Measured, with the flat-config
counterfactual, and pinned as a running check (test_maintenance.py part 13)
whose assertions state the WRONG behaviour on purpose. It wants its own card:
the remedy is in inverter.py and SAFETY-02's semantics, and a silent expansion
into a safety latch is how a rejected PR becomes a broken one.
Suite: 19/19 PASS, purged tree, bind-mounted :ro in goodwe-addon-ci.
No hardware was touched; every fixture here is SIMULATED and pack B's 3000 W
remains a marked hypothesis.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|