Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.
- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
that pinned "Solar is refused" / "three entities" updated.
Co-Authored-By: Claude <noreply@anthropic.com>
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py
Co-Authored-By: Claude <noreply@anthropic.com>
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.
Co-Authored-By: Claude <noreply@anthropic.com>
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.
Co-Authored-By: Claude <noreply@anthropic.com>
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.
Co-Authored-By: Claude <noreply@anthropic.com>
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.
Co-Authored-By: Claude <noreply@anthropic.com>
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>