Commit Graph
19 Commits
Author SHA1 Message Date
ems-agentandClaude 7bc8988be0 EV-21: Solar cuts the car first for the quarter peak
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m59s
In Solar, when the 15-minute period heads over the aim and the batteries
would have to give more, the car is lowered first: floor((car - excess) /
(230 x phases)) A, 0 under 6 A. At once without real headroom (saturated,
floor-limited, excess beyond what the batteries can add, no battery figure,
cover off, last 120 s), else after at most 15 s. One cut per episode from
its start, deeper only on a growing excess; restart with the start power
under the aim for the start time; none after a 2nd cut in the period.

Grading (formal C2): a Solar car Solar cannot cut is graded, banked and
left in the guard as in Off. A Solar car is never banked. Grey note and Why
"Solar lowered the car for the peak." Manual and Off unchanged.

Tests: test_ev21.py, test_ev21_paths.py, test_ev21_same.py; T49 in
tools/ev20_day.py; T50 in test_ev20_fuzz.py; test_ev20_guard section 8
moved from "as Manual" to "as Off" where Solar cannot cut (T51).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-25 17:01:07 +01:00
ems-agentandClaude 68856bc3a0 EV-51: Solar decides every meter-age rule on the writer step's own age; DEBUG line per step
checks / unit (pull_request) Successful in 41m26s
infra-pin / fresh (pull_request) Successful in 2s
The writer step took the meter age from the snapshot of the previous cycle
(silent / unknown_s / hold), so in production order the silent-meter pause
came one cycle late (C21) and a start or raise could still be written at an own
age of 31-39 s (C22, N8). The step now judges its own age: the pause timing and
held_pause, the non-zero write block (nz_block), and the late-readings hold with
its stale rule. Meter values stay from the snapshot; car.held / car.reading and
the arrival sources' spare-unknown check are unchanged.

Also: one DEBUG line per Solar writer step (time, meter age, decision, write);
tools/ev20_sun.drive takes cyc / phase / jitter / cset (default unchanged);
test_ev51.py (T1-T43, N1-N12); DECISIONS states the rule once.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-24 17:26:03 +01:00
Claude e0138a2ae5 EV-20: SPIKE-05 decisions C1, C6, C9 (brief v5) with rows for C1, C5, C6, C8, C9
checks / unit (pull_request) Successful in 34m42s
infra-pin / fresh (pull_request) Successful in 2s
C1: an own 0 A not yet read back is kept with the mode; a start in Off with
it writes the 0 A (retried), without it nothing; a start that will not write
warns once when the charger still has the add-on's current. C6: Solar's 30 s
gate also counts from Manual's latest write. C9: an exit also owes its 0 A
when the read-back shows Solar's own value. Rows for C5 and C8 too.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 21:33:28 +01:00
Claude 226e5a1e8b EV-20: Car Solar mode, spare sun to the car (charging only)
checks / unit (pull_request) Successful in 57m6s
infra-pin / fresh (pull_request) Successful in 3s
Solar as a second writer next to Manual (carmode.SolarPlan, SolarWriter on
ManualWriter's one write site, safe phase sequence and other-writer watch):
signed spare, Batteries first on the batteries' ratings, the margin, whole
amps rounded down, the 30 s / 1 A rule, start and pause dwells, auto phases,
a one-phase car. Every way out ends at 0 A, retried by EV-04's rule; at
shutdown before the inverters, three tries inside 15 s (D3); start-up and a
returning charger or HA write 0 A first (D2); never over another writer's
hold. The peak guard treats a Solar car as a Manual car (D1 wording). Solar
kWh sensor and card line; select.goodwe_car_sun_first; ev_margin_w,
ev_start_min, ev_pause_min with config, validator, translations, DOCS,
DECISIONS and CHANGELOG.

Checks: test_ev20.py, test_ev20_exits.py, test_ev20_writers.py,
test_ev20_guard.py, test_ev20_long.py, test_ev20_long_car.py,
test_ev20_fuzz.py (harness tools/ev20_sun.py, ev20_kit.py, ev20_day.py);
test_ev03/test_ev04 no longer use Solar as the refused example.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 20:31:26 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00
glenn schrooyenandClaude 9a76f1a968 MAINT-28 fix-forward rounds 1-4, re-applied after the release/1.0 merge
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 0020756aab Revert "Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)""
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 7bc8ad264b Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)"
checks / unit (pull_request) Successful in 27m32s
infra-pin / fresh (pull_request) Successful in 2s
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 01:33:24 +01:00
glenn schrooyenandClaude e7706150e8 MAINT-28: DECISIONS gives the measured reason for the uncapped give (review M-1); ctl_cycle comment one line + pointer (L-1)
checks / unit (pull_request) Successful in 27m38s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 05:53:55 +01:00
glenn schrooyenandClaude 29a8a05f30 MAINT-28: shorter test_maint28 runs (892 s -> ~280 s), digests re-pinned on 1b5f7c9; hold kept through the two short holds (documented); DECISIONS duplicate removed
checks / unit (pull_request) Successful in 40m7s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 02:29:27 +01:00
glenn schrooyenandClaude edf30f345a MAINT-28: keep the single shaping_suspended(.., maint_aim) call site (test_peak_margin pin); shaping_held takes its answer
checks / unit (pull_request) Successful in 32m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:58:19 +01:00
glenn schrooyenandClaude 8640bfcbc1 MAINT-28: hold only where MAINT-24 moved the aim (banked peak above the cap); test_safety119 pins stay
checks / unit (pull_request) Failing after 34m27s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:13:57 +01:00
glenn schrooyenandClaude 92f0387415 MAINT-28: reset the hold every cycle, test it; digests vs 1b5f7c9; DECISIONS numbers and mutants
checks / unit (pull_request) Failing after 36m49s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:44:32 +01:00
glenn schrooyenandClaude 4f9aa5223f MAINT-28: the hold is for N=2 and up (SAFETY-87 N=1 pins), N=1 peak digest test
checks / unit (pull_request) Failing after 36m51s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:28:01 +01:00
glenn schrooyenandClaude 8cd10ee6aa MAINT-28: during a real peak the maintenance charge stays paused until the house is clear of the aim
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m11s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 21:51:56 +01:00
glenn schrooyenandClaude 54a738dd87 MAINT-24: a started maintenance charge gets the cheap night
checks / unit (pull_request) Failing after 41m45s
infra-pin / fresh (pull_request) Successful in 2s
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:07:44 +01:00
goodwe-agent c50e2279dd SAFETY-136: a gentler loop on a slow meter until the last move shows
checks / unit (pull_request) Successful in 26m18s
infra-pin / fresh (pull_request) Successful in 2s
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 14:49:26 +01:00
glenn schrooyenandClaude 3939211176 MAINT-21: app/ctl_cycle.py - Controller.cycle, whole
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:29:52 +01:00