With master merged in (TARIFF-24), a forecast replaces the 1.5x widening, so
the shipped cost 0.10 is now the whole gap with a forecast. test_ux54.py's
modes-on scenarios were written for 0.15 and 21 of its checks failed on
release/1.0 + master (they pass on release/1.0 alone). They now set the cost
to 0.15 where they have a forecast: the same gate as before. Scenarios with no
forecast (nofc, stale) and modes off keep 0.10, widened as before.
(cherry picked from commit 665653517c, branch OPT-27)
Co-Authored-By: Claude <noreply@anthropic.com>
A new tab beside Home and Batteries for today and tomorrow: the solar
forecast, the solar measured so far, the house's expected use and each
battery's expected level, with the plan's own charge and give blocks under it.
- Blocks are Home's: today's are the plan's `runs`, tomorrow's come from the
same builders (`homeview.runs_for()`), in the plan lines' words.
- The sun is what solarfc reads; a daily total is spread over the bell and the
tab says so. The house is HouseProfile.estimator(), as the plan reads it.
- The level is new: `daycurve.curve()` gives each battery the role
`modetrade.decide()` gives it and moves it hour by hour inside the plan's
floor and ceiling. It is an estimate and counts on `solar_trust_pct`.
- Built on request (`GET forecast`), no Home Assistant call. Measured solar is
kept per hour in memory from the reading control already takes.
- A part not known yet is a note: modes off, no forecast, learning, no
forecast for tomorrow, a monthly cycle, no level, stopped, shadow.
No decision, command, timing or option key changes. Found, not changed:
`dayplan.plan()` over-counts a state-only forecast (DECISIONS/UX-54).
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- TariffPlan.arbitrage(now=...) is required (keyword-only, no default); so are
homeview.trade_verdict/refusal_key's now. Existing test calls pass one.
- test_arbitrage.py: no module-level decide wrapper. Fixtures that probed a
one-day plan after its extremes now hold two days (as a site does); the
flap day gets a unique cheapest and dearest hour; the replay breaks its
ties without direction. The flap bound is <= 4 and the replay check is
len(_trades) < 365 again. 228 checks pass on the old and the new code.
- test_price02.py part 6: ties (equal quarters, a real 15-minute day,
alternating hourly prices) and the required now.
- Identity pins: the masked digest is only for the older-tree comparison;
this tree's own digests are pinned with nothing hidden.
- DECISIONS: the tie analysis with numbers.
Co-Authored-By: Claude <noreply@anthropic.com>
test_price_run_fixes.py part 5 and test_modes_p3.py part 1 compare the modes-off
replay with digests printed on older trees. The trade sentence now says
"price period", and a sale quotes another "above the cheapest" figure once the
first cheap period is over. ident.trade_digest() hides exactly those two
things; re-measured on e3e4ba6, 7a00f12, 90bc901 and this tree, the digests
are the same, so every command is unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
peak_forecast_entity is read through pv.watts() by its unit_of_measurement;
the abs(raw) < 50 size rule is gone. No unit or a non-power unit means the
forecast is not used, with one warning per cause. The validator no longer
claims a kW sensor is taken as watts for this entity.
Co-Authored-By: Claude <noreply@anthropic.com>
The probe's trade was sized at the probing battery's rating. Its SAFETY-73
pin held 200 W of that, and the allocator put the rest on a battery with no
mode range (one in a maintenance phase): TEST-23 OPT-15 g7, -2300 W on A in
its maintenance charge for 34 s, grid 3100 W.
modetrade.decide() now asks PROBE_W for the probing battery plus what the
other chargers would have had without the probe; size() adds the probe on top
of their share, or files PROBE_W exactly, or nothing. _mode_trade() carries
the pin only on the ticks it is filed, so the window's first and last cycle
do not move another battery's share either. Modes off and modes on with no
probe are unchanged (bf9019e digests). Tests: test_opt20.py.
Co-Authored-By: Claude <noreply@anthropic.com>
F1: every password option is shown as ******** (set) or empty in /config/model
(options, running, ui) and in a stale refusal; the classic page draws it as a
password field; a save or validate that sends ******** or nothing keeps the
stored value. F2: a static_profile beside price_service is said once at start
(notification and log), not refused. F3 (owner, 2026-10-14): the no-price row,
Home line and notification only while maintenance_enabled is on. F4: tests for
the reviewer's R01 and R10. F5: price_service_token must be 16+ characters.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
clears the chargers, a probing refuser included, while a battery drains
(SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
(`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.
Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
until the quarter's first sample, as the old edge tick was not, so a
standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
drain and the day plan against the probe.
Co-Authored-By: Claude <noreply@anthropic.com>
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.
- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
day is summed. Hourly splits are merged when every member has one, else
the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
day's forecast unusable (no partial sum). A caution row names it by
position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.
DECISIONS/OPT-17-several-forecast-entities.md has the rules.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
While a battery settles from its ended drain (SAFETY-95), the house point
was grid + every battery's reading. A register can be 10 s older than the
meter, so B swung 860 -> 1650 -> 870 W on A's old reading (rig check 5).
Now the house point is held and moved only as far as the meter proves:
each battery is between its last changed reading and its commands since
(a reading that changed this cycle, or a refused side, as it reads).
N=1 and 1 s registers are byte-identical to release/1.0.
DECISIONS/SAFETY-103-old-readings-after-a-drain.md, test_safety103.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
B's power reading shows -95 to -118 W at idle (standby draw), so the
|reading| < 100 W refusal band never held a refusing B: never at N=2,
and since SAFETY-94's shared rule not at N=1 either (review F1).
Each unit now learns its idle reading (app/idle.py): only while control
runs, the unit is not refused/stale/tripped and its command has stayed
within 50 W for 120 s; first value a 120 s mean, then a 30 min follow;
samples beyond 250 W dropped, value clamped to 250 W; saved per unit and
restored. The shared refusal evidence, compute()'s N=1 engage and end,
the unit refusal ends, the stale-path refusal and SAFETY-42's "parked"
test are centred on it. Until learned it is 0 W, the rule as it was.
Refusing B caught at N=1 28/28/65 s and N=2 24/24/60 s (1/2/5 s
meters), before never; refusing A unchanged. Healthy B with its offset,
SAFETY-94's scenarios, 96 runs: 0 stale, 0 refused. Live replay: 0.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
The stale-reading gate counted its 35 s from the register's last change, so
after a rest the first read after a new command tripped it (SAFETY-58; live
2026-10-03, four trips 1 s after the command). It now counts only the time
the command asked the register to move.
At N=1 the refusal engaged after 12 frozen cycles if the reading was under
100 W at that moment, which a battery reversing through its lag passes at a
1 s meter. The refusal now needs the N>1 evidence at every roster size: under
100 W, one way, for 12 cycles spanning 22 s, restarting when the reading
moves 50 W towards the ask.
DECISIONS/SAFETY-94-lagging-battery.md; test_safety94.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2 a battery at or under its own peak reserve is held: it gives
nothing for the peak (weight 0 while the site gives) and the guard's need
is placed on the live, non-refusing batteries above theirs. The guard is
floor-limited, and alarms, only when those cannot hold the limit at full
power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold
the Home page at 0 W, because control keeps running. N=1 is byte-identical.
DECISIONS/SAFETY-87-guard-uses-able-batteries.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
At N>=2 a cheap-window maintenance charge files a site `hi` (`charge`,
P_MAINT_SHAPE) equal to what the charging pack's own `hi` places, so the
other pack never has to give against it. The charge is sized to the
quarter's headroom under the peak aim so it yields to the peak guard, and
to 0 W under a site safety stop. N=1 byte-identical (safety84_identity).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The start hour was compared with the UTC hour, so the shipped 10 started at
12:00 in a Belgian summer. It is now read in Home Assistant's time zone
(fallback: the container's TZ, then UTC, one log line says which), and the
default moves to 19. DST: a missing hour starts at the first hour after the
jump; a repeated hour starts only in its first pass. Stored options are not
rewritten: a saved 10 now means 10:00 local (DOCS, CHANGELOG).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N=1 the drain is the site SET at P_MAINTENANCE (60), so the peak floor
(P_PEAK, 50) was not applied and the house imported what the drain left.
Where the floor asks for more than the drain rate, main.py now refiles the
peak claim at P_MAINTENANCE, so it wins; safety SETs still park everything.
Nothing else changes: safety78_identity --diff against 35cdffe changes only
cycles where the guard wanted more than the drain; N=2 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Conflicts: modetrade.decide() takes both the day plan (targets) and
SAFETY-78's draining flag; the Why line keeps SAFETY-78's other_cycle
ahead of the plan's word (test added).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Cheap hours only fills to the ceiling with or without a forecast, as the
design (section 1) says. Skipping the sun's share cost 0.31 EUR on real
2026 prices (29.72 against P3's 29.41) and saved nothing on the P3 set.
- A forecast reading from before local midnight is stale: until the
integration refreshes, "left today" is still yesterday's 0 and
"tomorrow" is really today.
- Forecast entity ids must be sensor.[a-z0-9_]+ (they go into the
/api/states/<id> path).
- House profile: a stored day that is not a date, or is after today, is
dropped instead of kept forever.
- Text: the forecast line says "for the rest of today"; the learning line
no longer promises "tomorrow" (a plan needs one full day).
- Tests for four surviving review mutants (hour sample floor, the dear run
after the cheap run, share by room, daytime use) and the fixes above.
- Replay tool: `--fc zero` (a forecast of no sun).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The alarm must hold for peakguard.ALARM_HOLD_S (10 s) on the projection's
clock. A load that tops cap + battery for ~5 s every 30 s alarmed at every
quarter start while the quarter landed under the aim (sine4500_fast).
- A cycle with no battery reading leaves the hold alone.
- Notified once per quarter, but the ERROR line is written per episode.
- New sim scenarios (sine4500_fast, twice7000, step6500_gap) with 5a4cdc2
digests; control still byte-identical. Unit checks for export and the
hold across a missing reading. test_peakguard's saturated fixture moves
the hold start back instead of waiting it out.
- DECISIONS and DOCS updated: costs of the hold, tolerance reasoning, the
double count in control left to a follow-up.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
F1: with battery modes on, the peak guard projects the quarter `now` is in
even before its first P1 sample (PeakTracker.project(roll=True)), and only
a measured stop latches the period. The edge tick no longer reads "no
seconds left", so a charge is not stopped and latched at a quarter edge.
F2: after a run edge the loop is held at E until the meter shows the step
(EDGE_HOLD_S, longer while the battery still moves). The replay gained a
lag model (dead time, reading age, P1 debounce, 1 s cycles) that shows
TEST-23's overshoot without the hold.
F3: a charge refuser's SAFETY-73 probe inside a cheap run is a charger
pinned at PROBE_W, the others rest, so the probe actually runs.
Modes off stays byte-identical to 5a4cdc2 (new late-P1 identity scenarios).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The alarm now also needs peakguard.load_too_high(): with the battery at
full power, the quarter still ends more than 10 W over the real limit.
The battery reading is the lower of this cycle's and the last, so a meter
sample from before the battery's last increase is not counted twice.
At most one alarm per quarter. Control outputs unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At two inverters the drain pins its pack and the site target is split
around the pin. Below the pin the other pack had to charge, the allocator
refused the opposite directions, and the site sat at 0 W with an ARBITER
line every cycle (house below or above the drain rate, or a grid charge).
main.py now files a site limit `drain` (lo = what the pin places, at
P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds
power in the same direction. A drain that cannot give power waits with
one log line. With battery modes on, no grid charge while a pack drains,
and the other battery's card says why. N=1 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A Home Assistant solar forecast (Forecast.Solar, Solcast or Open-Meteo
shapes) and the add-on's own hourly house use decide, before each cheap
run, whether the sun will fill each battery before the expensive hours.
Leftover solar then buys from the grid only the shortfall; Cheap hours only
skips the part the sun covers; Solar first never grid-charges. No, stale or
failed forecast: P3 option A exactly (12 digests pinned from 5a4cdc2).
Replay (16 recorded days, forecast errors from Elia's day-ahead BE solar):
year-earlier prices P4 19.15 vs P2 19.33 / option A 19.44 / old trade 18.14;
real 2026 prices P4 29.19 vs 32.26 / 32.01 / 31.40 EUR net.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Cheap and expensive hours as runs of consecutive firm price slots
(priceruns.py); each battery's role per tick from its mode (modetrade.py):
grid charging for Leftover solar / Cheap hours only, never Solar first;
holding for the expensive runs; selling per battery (pack_sell) above the
spread and the floor. The site trade is sized inside the modes (loop bound)
and the peak guard's headroom; a run edge reseeds the loop. Cheap hours only
and selling are enabled on the Batteries screen and in the HA select
(appended). The site Why row no longer says "held back" when the peak limit
pushes power up (F2). Modes off: byte-identical to 7a00f12 on the trade path.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- quarter_target_w() is now the margin under quarter_ceiling_w(): a peak
banked between cap - margin and the cap was aimed at exactly, so one
overshoot crossed the cap; above the cap the same overshoot raised the bill.
- safety79_identity.py hashes charge_headroom_w() and the shaping suspension,
and adds n1_maint/n2_maint (cheap window, forecast across cap - 50 .. cap).
Digests re-printed on ed739d4 and pinned; margin 0 still identical.
- test_margin_under_banked_peak; DECISIONS and DOCS updated.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The peak limit's Why and plan block need a real power request (floor above
0 W), not a blind or floor-limited guard. An Off battery gets the peak
block only while it gives power. Why no longer says every battery gives.
- test_batteries_screen pins the fixture clock: unpinned it failed every
morning. New checks cover the trade and cycle filters, the blind guard and
an Off battery that A covers alone.
- Settings keeps only a picked view; a link to Installer is not remembered.
- Browser check: badges, unsaved change across views, locked value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.
peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
- Batteries: one card per battery with On/Off, the mode list (cheap hours
and selling greyed out until OPT-11 P3), level, and Now / Today / Why
lines built in homeview.py. Replaces the OPT-11 P1 minimal cards and uses
the existing pack_use / pack_mode actions and store keys.
- An Off battery the peak limit still needs says so with its figure; no line
shows 0 W beside moving power (OPT-11 P1 test F2). Today says "Not planned
yet" until OPT-11 P3/P4.
- Home's plan leaves Off batteries out, except for the peak limit.
- Settings opens on Simple: the layout's simple fields with an applies chip
and a note, plus the battery switches and modes. Installer is one tap.
- English and Dutch words in app/ui_text; test_batteries_screen.py; browser
check tools/ux13_browser_check.py (CHECK=1 ux13_screenshots.sh); new and
changed screenshots only.
No control, allocator, arbiter or command module changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
- arbiter: a mode now gives way only as far as a site limit above P_MODE
needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
released only when the peak floor bound S, so a trade won above the floor
kept them and placed less than the floor (an Off battery at N=1 went to 0 W
under a 2000 W floor), and a capped grid charge released an Off battery.
While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
(peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
loop bound counts live units only). DOCS and DECISIONS say the new rule.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
fallback per key; the page picks by browser language. Home's sentences
move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
lists for both languages, no inline details, untranslated Dutch caught.
Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
static_profile and names bad times, empty prices, overlaps and gaps.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.
Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
R1: first_start also needs a Store created at this boot (Store.fresh), so
old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.
- First run: /config/model says `setup_needed` when the stored options name
no power request entity, or on a new install (no `setup_done` and no
`auto` in the Store, control not started). The page opens #setup only
when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
change decides: up keeps meter_invert off, down turns it on; a net or
import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
each power request entity exists in HA (bad if not, SAFETY-77), battery
levels and power with direction, solar sign, prices. Saves with
shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
1. Discard reloads /config/model: after a stale save the page kept the
new fingerprint with the old values, so Discard + Save overwrote the
other surface's change without a 409.
2. Removing cards back to one restores the stored inverter shape, so a
flat site stays flat after add + remove.
3. A choice the page can only keep ("Other time windows") stays offered
while it is the stored value.
4. A load locks every locked value again.
5. at_zero() needs an accepted 0 W write; before the first one Home says
"Going to 0 W" (the heartbeat writes every heartbeat_s, so it clears).
6. A field with a unit drops the translation's "(W)" from its label: the
peak limit read "Peak limit (W)" beside a kW value.
7. A mirrored choice lists the mirrored field's keys, so a search for
static_profile finds the contract on a fixed-price site.
8. test_settings: a save refused by ui_to_options writes nothing.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Settings tab: the Installer view (app/static/settings.js), drawn from
app/uilayout.py through the new app/uipage.py: search, six collapsible
groups with "n to fix / n to check / n changed" badges and an "applies
after a restart" chip, radio cards, segmented choices, sliders with units
(the peak limit in kW), entity pickers with search and the live reading,
inverter cards, solar rows, locked measured values behind "Change", and
the add-on's refusals, warnings and info beside the field they name.
- Save path: the page posts its model to the existing config/validate and
config/save; uimodel turns it into options before the shipped validator,
so nothing it refuses is saved. No route added. A value equal to the
stored one is written as stored, so a save that changed nothing writes an
identical blob. Save bar, then the restart dialog that names 0 W.
- The region choice shows its preset year; Wallonia and Brussels are listed
as having no preset yet (TARIFF-22). "Classic settings" keeps /config.
- P1 test findings: (a) "Going to 0 W" until the last accepted power request
is 0 W; (b) the trade blocks and the price line name the feed's own points
("Lowest published price"), the hour bars say "hour average"; (c) the entity
list's WARNING gives a reason on a timeout.
- test_settings.py; test_home, test_haentities, test_uilayout extended.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
month_peak and control beside the old fields. The plan is what the add-on
does today: the arbitrage verdict (the same plan.arbitrage() call as the
cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
The foundation for the new settings page. No visible UI change.
- app/uilayout.py: screen -> group -> part -> field for every option in
config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
scale, step, entity kind, show conditions, Simple/wizard placement and
"applies after a restart". Ranges stay in the schema, words in
translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
inverter vs the list, solar rows, static_profile from simple prices, a
year-stamped region preset for the levies figure, and an OPT-11 hook for
arbitrage_enabled that changes nothing yet). Unchanged derivations write
the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
a note when a list is passed; config_notes() adds checks that need live
data (missing entity, a kW sensor read as W, a limit below this month's
peak). /config/validate returns them as "notes". No refusal changed: 261
recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
the TEST-23 option files and config.yaml defaults), test_haentities, a
warning-tier part in test_validate; test_messages scans notes and
ui_text; test_pv and test_selfconfig part 7 widened on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
own 100 W answer, not below saturation_w: a battery derated to 100-499 W
was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
DECISIONS record carries the traced cause of the replay's extra trips.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At the BMS cut-out the saturation freeze held the last request for hours
(+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid
error changed sign. compute() now carries a refused direction: after
SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction
at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go
on charge, an answered probe, stop/start or another writer. A stale-reading
trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's
~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A).
test_refusal.py drives the real Controller and gate; tools/replay_refusal.py
replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined
where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what
SAFETY-58/59 must take into account.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive
for consumption and negative for production. `pv_invert_entities` lists the
ones to flip; the flip is applied per member inside pv.total(), before the sum,
so the MQTT `pv` row and the status page carry the corrected figure. Default []
is byte-identical to 0.12.0.
Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0):
a parallel list validates the 0.12.0 blob unchanged and renders as its own
translated repeatable field; dicts on pv_entities refuse 0.12.0's stored
strings; a prefix is invisible syntax; a global bool cannot describe a mixed
roster. Status page marks flipped entities and cautions per entity below
-50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged.
Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
predeploy_check.py and rehearse_roster.py now assert a positive property of
their input (a JSON object, most of whose top-level keys are known option or
store keys) and refuse anything else with the shape named. The `ha apps info
--raw-json` wrapper, a truncated or list-wrapped state file and a wrapped
config no longer produce "CLEARED" / "NO FINDINGS" with exit 0.
Also: a clean --no-live-entities rehearsal exits 3, not 0; alloc_sim.py
exits 1 when split-invariance FAILS; decode_bus_capture.py takes several
paths and exits 1 on a file that is mostly not frames.
Graded by the new test_tool_inputs.py; DOCS.md says to pass .data.options.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
0.11.0 shipped `pv_entity` as a single string. The reference site's owner
reported within minutes of it going live that they have several PV inverters
and could configure one - which is ordinary for a multi-string roof, not a
property of one house. `pv_entities` is the roster and the row carries the
SITE total.
⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`,
and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL
ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no
irradiance" conclusion the channel exists to TEST. So `pv.total()` answers
`None` the moment any configured entity is absent: the topic carries HA's own
`None`, the entity goes to `unknown`, the recorder records a GAP. The
alternative (the partial sum beside a contributor count) was implemented and
run as mutation N1b; it loses because the MQTT row is read COLD a week later by
an attribution that would believe it, while the qualifying count would live in a
second entity with its own history. The partial information is not thrown away -
the STATUS PAGE names every entity that reported, with its watts, and every one
that did not, with its reason, because that surface is read LIVE by a human who
wants the diagnostic.
⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is
`is None`, never falsiness - a roster that blanked the site on a zero would
report an absence on every clear evening.
THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list:
tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an
0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and
deepmerge's list strategy is `override` so a `[]` default does not rescue it -
the live add-on would not start. `match(.*)?` does accept both shapes and is
rejected for a different, measured reason: it validates nothing (a string, a
list and the integer 417 all pass) and renders as a plain text box. So
`pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for
`inverters:`, with a status caution saying which key won - a union would
double-count the inverter the old key still names.
STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than
replaced and now grades five claims over three document sets. The control hash
is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the
roster control document is byte-identical between the two trees. 2/5 is a claim
TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly
as 0.11.0 does" is a real cross-tree identity over control AND telemetry.
⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit
24: a discriminator defined as "the baseline lacks this feature" dies on the
release that ships the feature, and dies as a false refusal.
Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B
(`sum` -> `max`, the same three characters) and was run on a fresh copy with
`cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO
contributions in two units with absence driven at EVERY position - a member
contributing 0 W could go absent without moving the sum of the rest, which is
habit 23 with a coinciding value in the arithmetic rather than in the plant.
31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0,
so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG
entry is wanted and deliberately not written - 11b forbids `## Unreleased` and
the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the
material it needs.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU