0c7e786ed5b4e2061ba55acf6ff9a9e32f159f78
10
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
ab6fbe2f9e |
SAFETY-25: record the owner's decision - option a, with alloc-01 as the revisit trigger
checks / unit (pull_request) Successful in 3m43s
The product owner answered SAFETY-25's §1 on 2026-09-02: OPTION A. The BMS cut-out is the DELIBERATE and only backstop for demand-driven discharge on the grid-following loop, and Option B - a loop-side reserve floor - is DEFERRED rather than rejected. Option A is the shipped behaviour, so this is a recording, not a change. `app/` is touched in exactly two places and both are comments that claimed the question was still open (freeze.py's finding, peakguard.py's point 2). No setpoint, no claim, no option, no default moved. The 17-suite run is green on the same numbers as before. WHY DEFERRING IS THE SAFE DIRECTION. Option B's proof - bms_soc_floor < loop_soc_floor <= peak_soc_floor, run through the real arbiter in test_peakguard.py part 10d - has an unstated premise: the reserve predicate and discharge_permitted() read the SAME state of charge. With two packs they read different numbers. The reserve binds on the emptier pack and files hi = 0; the peak guard, reading the other pack or an average, files lo = excess > 0; lo > hi is arbiter clause 3 and the answer is 0 W - the battery parked in the billed quarter, which is the failure the memo itself marks fatal. And no config validator can catch it: it is a runtime divergence between two readings, not a config ordering, so CFG-01's shape of check passes on the exact tree that parks the battery. Option A's cost is energy; Option B's cost built too early is the one quarter of the month that sets the bill. THE REVISIT TRIGGER IS ALLOC-01, recorded in §0c. Under ARCH-01's host-side allocator the two claims stop sharing a list: the loop floor becomes a per-inverter `hi` consumed as an INTERVAL at stage A, while the peak floor stays a site `lo` at stage B. Different claim lists, different stages, structurally unable to cross - a stronger argument than the ordering rule, because it makes the crossing unreachable rather than harmless. That is the shape in which Option B becomes safe to build. WHAT HAS TO BE RE-EARNED AT N=2 is stated plainly in §0d rather than left for someone to discover. SAFETY-27 now names five floors across two packs, so "the SoC" stops being a scalar the config can bound. And part 10f - the pin that made SAFETY-25 mergeable - CANNOT EXPRESS TWO PACKS: its dynamic half is a scalar 0-100 % SoC sweep against a single-series capture, and a two-pack exposure lives in the DIFFERENCE between two readings, which that sweep visits at no resolution. Its static half, the AST scan pinning the eight claim sources, still bites at N=2; the dynamic half goes silent. Merging a two-pack reserve on 10f's current green would be merging on a check that cannot see the failure. The options analysis is kept intact on purpose - §1-§7 stand exactly as written, including §5's "(recommended)" on Option B and §6's recommendation, with a new §0 saying what was decided and §6 marked as answered. A memo that recorded the verdict and deleted the reasoning is the failure this DECISIONS/ directory exists to prevent. Part 10e's check moved with the memo: it used to pin the honest "Status: OPEN" line and now pins that the memo names the option, the date and the trigger AND still carries both options and the recommendation. The tripwire itself stays - a ninth claim source in Controller.cycle() still takes 10f red on the line it is written, and "deferred" is precisely the state in which someone builds Option B by accident. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
d5b1ef19b3 |
CFG-03: give maintenance option defaults one source of truth
checks / unit (pull_request) Successful in 3m44s
Option defaults for the maintenance cycle were declared in three places that
could disagree, and MAINT-04 proved they already did. config.yaml shipped
`maintenance_charge_w: 2000`; main.py carried TWO `opts.get(..., 2500)`
fallbacks; MaintConfig's dataclass carried a third `2500.0`. So an options dict
with the key ABSENT was ACCEPTED by validate.py's rule 6 - which read 2000 -
and then built by main.py at 2500, against a 2000 W ceiling:
options dict with maintenance_charge_w ABSENT, max_w=2000
validate_startup_config -> [] (accepted, no problems)
MaintConfig().charge_w -> 2500.0
arbiter.resolve() -> 0.0 W, contradiction=True
That is the bug rule 6 exists to refuse, passing rule 6. It is unreachable on a
Supervisor install, which always supplies every key from config.yaml, and fully
reachable from sim/inject.py and from the test suite - which is where anyone
debugging maintenance actually works.
MAINT-04 shipped a TRIPWIRE and said so: test_validate.py pinned all three
literals and asserted the consequence through the real arbiter, so the
divergence could not silently widen or be half-closed. Its PASSING CONDITION
WAS THE BUG. Both it and validate.py's comment said to delete each other when
the divergence was closed. It is closed, so both are deleted.
THE DIVERGENCE WAS WIDER THAN ONE KEY. `maintenance_discharge_w` had the
identical three-way split (config.yaml 2000, MaintConfig 2500) and the card
named only the charge side. Closing one and leaving its twin would have
satisfied the numbers and left three sources of truth one line down, which is
the state that produced the bug. Both are closed, and so is the whole family:
all eight `maintenance_*` keys go through the same mechanism.
WHAT THE SINGLE SOURCE IS. config.yaml's `options:` block - it is what the
Supervisor reads and what the operator edits, so it wins by definition. There
is now exactly one in-code copy, `maintenance.MAINT_OPTION_DEFAULTS`, which is
TARIFF-02's `PRICE_OPTION_DEFAULTS` and SAFETY-24's `PEAK_OPTION_DEFAULTS`
pattern applied to the family that named the card - validate.py's rule 8 comment
already called that "CFG-03 read as a rule rather than as a complaint", so this
makes the rule hold where it was first broken rather than inventing a fourth
mechanism for one option family.
A MIRROR RATHER THAN A RUNTIME READ, and the reason is mechanical: the
Dockerfile copies `app/` and `run.sh` into the image and NOT config.yaml. The
running add-on cannot open the file it is configured by, so there is nothing to
read at 03:00 on a client's Pi, and a YAML-subset parser that could fail at
import is a new way for the add-on not to start. What makes the copy safe is
that test_maintenance.py pins every entry by READING the shipped file - drift is
a CI failure, not a comment.
EVERY OTHER SITE NOW DERIVES FROM IT OR HAS CEASED TO EXIST:
* MaintConfig's eight dataclass defaults are indexed out of the mirror. No
numeric literal survives in the class that held the third opinion.
* `MaintConfig.from_options()` is the ONLY place in the add-on that reads a
`maintenance_*` option. main.py's eight inline `opts.get(key, <literal>)`
calls are gone: moving the read next to the mirror means the fallback cannot
be anything but the mirror, because there is no literal in sight of it to
disagree with. It uses `key in opts` rather than truthiness, so a shipped
`false` or `0` is honoured instead of being quietly replaced by the default
- this card's own bug in a different costume.
* main.py's SECOND fallback site - the cheap-window charge floor at the
P_MAINT_SHAPE claim - reads `self.maint.cfg.charge_w` instead of re-opening
the options dict with its own literal. The Controller had already parsed
this once in __init__; asking the object that owns it cannot drift from it,
and the rate the shaping asks for can no longer be a different number from
the rate the state machine drains at on the same install.
* validate.py's rule 6 and its `maintenance_discharge_w` warning take their
fallbacks from the mirror.
WHERE THE RANGE LIVES, STATED AND CHECKED. config.yaml's `schema:` block carries
`maintenance_charge_w: int(500,5000)` - a fourth declaration site of a different
kind. It is a BOUND, not a default, so it is not this bug; but leaving the
question open is how a fifth site arrives. The decision recorded in config.yaml
and in maintenance.py is: bounds live in the schema block ONLY, because the
Supervisor is what enforces them and the Supervisor reads only that file, so a
Python copy of `int(500,5000)` would be a place to disagree and nothing else.
test_maintenance.py checks both halves of that: every mirrored key must have a
schema entry - without one the Supervisor drops the option and the add-on
silently runs on the mirror instead of the operator's value - and every shipped
default must lie INSIDE its own range, since a default the schema rejects is a
config that cannot be re-entered once it is edited. What the schema grammar
cannot express is a relation BETWEEN keys (`maintenance_charge_w` against
`max_w`), which is exactly why rule 6 is written in Python and why it does not
belong in the mirror either.
THE REPLACEMENT CHECKS, AND HOW THEY WERE VERIFIED. test_validate.py's new
section exercises the same four consumers the defect ran through, the same way:
the validator ACCEPTS a dict with every maintenance key missing; a REAL
Controller built from that same dict holds 2000 W (through main.py, not through
a regex over its source); `MaintConfig()` answers 2000 W with no dict at all;
and the real arbiter emits `-2000 W, limited by supervised(max_w)` instead of
`0 W, contradiction=True`. test_maintenance.py pins the mirror to config.yaml in
both directions - equal values, and full coverage of every `maintenance_*` key
the file ships, so a ninth key cannot arrive unmirrored - and asserts the
consumers move as a RELATION rather than against numbers, reading MaintConfig's
defaults back out of `dataclasses.fields()`.
Each new check was verified by BREAKING the thing it watches and observing red,
this project's rule:
1. config.yaml -> 1500, mirror left at 2000: test_maintenance 1 FAILED,
test_validate 4 FAILED.
2. config.yaml AND the mirror -> 1500: green again, and every consumer moved
together - MaintConfig() 1500 W, the Controller 1500 W, and the arbiter
`-1500 W, limited by maintenance(cheap-window charge)` where it had said
`-2000 W, limited by supervised(max_w)`. That is AC4: change the single
source and watch the consumers follow.
3. `charge_w: float = 2500.0` retyped into the dataclass: 2 FAILED in each of
the two files.
4. `opts.get("maintenance_charge_w", 2500)` restored in main.py: 1 FAILED,
naming the file and the literal it found.
5. `maintenance_hold_min` deleted from config.yaml's options block: 3 FAILED.
Full suite 17/17 in goodwe-addon-ci, twice, once under parallel load.
Stale prose that asserted the now-closed divergence as current is corrected in
app/watchdog.py, test_watchdog.py and test_peakguard.py - watchdog.py's example
still uses 1500 W, but because the point of the example is a charge strictly
inside the ceiling, not because 2500 is what ships.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
e498dd4c1c |
SAFETY-25: pin the claim-source set, so the tripwire is one
checks / unit (pull_request) Successful in 3m53s
The durability claim this PR shipped was FALSE, and the reviewer of #31 disproved it by building the fix. Part 10 said, in four committed places, that it "goes RED the day a loop-side floor is built, so the exposure cannot change size under a green suite". The reviewer implemented the memo's own recommended Option B in main.py - a `Claim.limit("reserve", P_LOOP, hi=0.0)` filed under a `loop_soc_floor` - and the ENTIRE SUITE STAYED GREEN. Part 10 green. Mutation 13 went on printing "NOTHING PREVENTS IT, ON PURPOSE" and the same 21 % -> 10.0 %, on a tree where something DID prevent it. Pushed to an absurd always-binding 95 % reserve it was caught only by SAFETY-24's pre-existing part 7 wiring checks; part 10 was still green. THE CAUSE IS STRUCTURAL, not a missing assertion. `replay_loop()` hand-builds main.py's claim list as a literal `[supervised, loop, peakguard.claim(...)]`, so it is blind to any claim main.py ADDS - which is exactly where AC 2 would be built. That is this repository's named failure mode: a check that observed something other than what it claimed to observe, shipped as a guarantee inside the document that recommends the change. THE FIX IS 10f: THE CLAIM-SOURCE SET, PINNED, two ways because the two fail differently. * STATICALLY, over `Controller.cycle()`'s own AST. Every `claims.append(...)` in it must be one the scan can read - an unreadable append FAILS rather than counting as nothing, which is how a scan like this goes quietly vacuous - and the sources it can file must be exactly {device, supervised, failsafe, safety, peak, arbitrage, maintenance, loop}. A ninth takes part 10 red on the line it is written, in every configuration, whether or not any fixture here reaches the state that files it. * DYNAMICALLY, through REAL `Controller.cycle()`s with main.py's OWN `resolve` spied - not a list this file built and hoped matched - swept over the WHOLE 0..100 % SoC range in the two states 10a-10c replay. Idle: exactly {device, supervised, loop}. Floor-limited: exactly {device, supervised, loop, peak}. A claim conditioned on a low pack, which is the shape a loop-side floor has, cannot hide from a sweep that visits 0 %. And the fold is checked rather than assumed: main.py's two P_SAFETY rating limits are both symmetric LIMITs, so replay_loop() modelling them as one `supervised` claim at the tighter bound is exact. MEASURED AGAINST THE COUNTEREXAMPLE. Reproduced first on the unfixed tree (green, as reported). On this tree the reviewer's Option B at its recommended default takes part 10 RED on 3 checks, and the 95 % variant on 6. Nine mutations were run in all, each against a freshly copied tree with no `__pycache__` present, mounted `:ro`; all nine red, no survivors, no `+0 B` delta. MUTATION.md records why a second round was needed: the first round's mutations were all aimed at DISARMING the guard, while the claim part 10 actually made was about the guard being FIXED. The four false sentences are replaced with what is now true, and each says WHICH half catches WHICH shape - 10f for an arbiter claim (Options B and C), 10a-10c for a clamp inside control.compute() or the guard (Option D), which the replay drives directly. AC 2 IS STILL OPEN AND NOTHING HERE BUILDS IT. The loop-side floor was a test mutant, reverted before commit. The memo still says "Status: OPEN. This is a memo, not a decision." Also, non-blocking, from the same review: the NOT READY banner had inherited the new scope sentence and become a ~550-character paragraph that the row three lines below repeated verbatim. A checks() row may now carry an optional short `banner` form; the floor-limited row does, and `status_payload()` prefers it. THE ROW IS UNCHANGED - shortening that would have been weakening AC 3 - and rows without the key are unaffected. Graded, and mutated: dropping the short form goes red. Merged origin/release/1.0 first (CI-02), keeping both tickets' CHANGELOG entries. Full suite green: 17/17 in goodwe-addon-ci (test_ci_gate.py needs `git`, which CI-02 added to .gitea/ci/Dockerfile but the local image lacks; run with it installed and it passes). Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
182102eeaf |
SAFETY-25: say what peak_soc_floor bounds, and measure what it does not
checks / unit (pull_request) Successful in 3m41s
peak_soc_floor reads like a pack-wide reserve and is not one. The
grid-following loop has no SoC guard of any kind, so on a sustained-load
evening it discharges straight past that number and keeps going until the
pack's own BMS cut-out stops it.
The gap has now been written down four times without being filed -
SAFETY-18's finding (freeze.py:18), SAFETY-24's module note, its PR body,
and its honestly-uncaught 13th mutation - and never once measured. It is
measured here, on the committed 2026-08-20 capture, driving the SHIPPED
control.compute(), peakguard.decide(), peakguard.claim() and the real
arbiter.resolve() in main.py's order:
19:00-22:00 UTC, 830 W mean, minimum 701 W, zero export in the window
reference pack (300 Ah x 51.2 V x DoD 90) started at 21 %, one point
above peak_soc_floor
ends at 10.0 % - the bms_soc_floor cut-out
1525 Wh delivered by the LOOP over 587 cycles
549 cycles below peak_soc_floor, 343 of them still discharging
0 cycles on which the peak guard filed any floor at all
AND IT IS A BEHAVIOUR, NOT A CONFIG VALUE. The same evening ends at
9.9715 % at peak_soc_floor = 5, 11, 20 and 60 - the shipped value and both
ends of the schema range - identical to four decimal places. The option an
operator would reach for cannot move the number by any amount at all. On
the same day's high-load block the two states coexist: 49 cycles reporting
PEAK GUARD FLOOR-LIMITED and, on all 49 of them, the arbiter simultaneously
granting the loop up to 2000 W of discharge.
WHY SAFETY-24 COULD NOT CLOSE IT. The peak guard files a `lo` limit - a
LOWER bound on the setpoint. That asymmetry is exactly what makes it
trustworthy: a reviewer proved across 19,800 combinations that it can never
lower a target, cap a discharge or contradict the arbiter. The same property
makes it structurally incapable of stopping a discharge the loop itself
wants. A floor on the guard cannot become a floor on the pack by being
raised, and the sweep above is that sentence measured.
WHAT THIS COMMIT CHANGES IS THE HONESTY, on the four surfaces an operator
actually reads. That half is required whichever way the open question is
answered, and it is the real misstatement on the live system today:
* config.yaml, beside the option itself - it BOUNDS THE PEAK GUARD ONLY
and is NOT A PACK-WIDE RESERVE, with the replayed evening and the sweep;
* DOCS.md, in the options table and in a new section carrying the figures;
* the STATUS-PAGE ROW for a floor-limited guard. This is the one line a
human reads at the moment the guard stops discharging, and read alone it
says "the battery is being held at peak_soc_floor" - which the replay
shows is false in every cycle that row is rendered;
* the PERSISTENT NOTIFICATION, which outlives the page. It now names what
has stopped (the guard buying a lower bill) and what has not (the pack
being spent).
peakguard.py and freeze.py carry the measurement beside the findings they
already recorded, so the next reader does not have to take the caveat on
trust.
THE PRODUCT DECISION IS NOT TAKEN HERE, and must not be. Whether the loop
gets a reserve floor of its own decides whether this house's battery may
discharge to the BMS floor on a heavy evening; that moves real energy and it
is the owner's call. DECISIONS/SAFETY-25-loop-soc-floor.md is the memo AC 1
asks for: the options, what each costs, what each protects, weighed against
MAINT-01 (a pack repeatedly at the BMS floor is the SoC-drift condition the
maintenance cycle exists to correct, and an over-tight reserve fights it from
the other side) and against the fact that this would be the FIFTH SoC key -
OPT-04's arbitrage_soc_floor fired SAFETY-24's "revisit if a third floor
appears" trigger unremarked, so SAFETY-27's naming decision should land
first. It carries a recommendation and says plainly that it is not a
decision.
It also records a trap found while writing it, and now CHECKED through the
real arbiter rather than described: the obvious shape of a loop-side floor
is a `hi` limit at P_LOOP, and filed while the peak guard is asking for a
positive floor that is `lo > hi` - which arbiter.py resolves to a
CONTRADICTION at 0 W, the battery PARKED in the one quarter of the month
that sets the bill. It is the same crossing-limits hazard
shaping_suspended() already exists to avoid. The ordering
`bms_soc_floor < loop_soc_floor <= peak_soc_floor` removes it provably,
because wherever the reserve binds the guard is already floor-limited and
files lo = 0; both halves are run in part 10d.
test_peakguard.py part 10 is a TRIPWIRE, not a guarantee. It records a
defect and goes RED the day somebody builds a loop-side floor, so the
exposure cannot change size under a green suite and closing it has to be
deliberate. Part 11's mutation 13 stays honestly NOT CAUGHT - nothing
prevents the loop discharging past this floor - but it now reports a number
instead of a sentence.
Verified: 16/16 suites green in the CI image. Eight mutations, each against
a tree copied fresh with __pycache__ excluded and mounted :ro, so no .pyc
existed to go stale (MUTATION.md's structural immunity, the same one it
records for CI); byte deltas +61, -8, -465, -430, -1088, -46, file deleted,
and -95; none is +0 B. All eight go red on the named check:
M1 peakguard.claim() also files hi=floor_w -> 7 red, incl. 10c
M2 control.compute() gain forced to 0 -> 6 red, incl. 10a/10b
M3 scope sentence removed from the status row -> 10e red
M4 scope sentence removed from the notification -> 10e red
M5 scope paragraph removed from config.yaml -> 10e red
M6 scope bullet weakened in DOCS.md -> 10e red
M7 the decision memo deleted -> 10e red
M8 arbiter clamps crossing limits instead of
reporting a contradiction -> 5 red, incl. 10d
AC 2 is left explicitly OPEN, pending the owner's answer.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
7b4877d56d |
TEST-15: purge the bytecode cache before a mutation run, not after
checks / unit (pull_request) Successful in 3m35s
FCST-03's developer reverted `self.provisional` to `here.provisional`, re-ran, and reported the mutation as a survivor. It was not one. CPython validates a cached `.pyc` on (source size, source mtime truncated to whole seconds), and that edit moved neither number - same length, same second - so the interpreter loaded the bytecode it already had. Disassembly settled it at the time: the source read `here`, the running code loaded `self`. A mutation run had graded code that was not there, with no error and exit status 0. This does not make the results already on the record wrong. It makes them UNVERIFIED, and that distinction is the whole card - so nothing here re-runs a campaign and nothing here quietly assumes the old numbers hold. REPRODUCED, THEN CLOSED. test_bytecode.py builds a real package whose two return values are the same length, imports it in a real subprocess, rewrites it inside the same second (retrying until both writes land in one whole second - milliseconds, no sleep) and reads back which value ran. Part 1 shows the interpreter running SELF off a file that says HERE. AND THE TWO OBVIOUS MITIGATIONS DO NOT WORK. Measured, not read off documentation: `python3 -B` and PYTHONDONTWRITEBYTECODE=1 are write-side only. Neither stops an EXISTING stale .pyc being read, and a mutation run always has one, because the previous run wrote it. Part 2 grades both still running the old code. The advice in test_control.py's coverage audit led with `-B`; it is corrected here - the purge is the half that works, and `-B` earns its place by keeping THIS run from leaving a cache for the NEXT edit to inherit. NO SLEEP ANYWHERE. One-second mtime resolution is the mechanism, not the enemy. Waiting it out would slow every run down and would still only cover the edit somebody remembered to slow down. THE HARNESS. tools/mutation_run.sh purges, prints a sha256/byte fingerprint of every app/*.py it is about to grade - so a mutation report can say WHICH source produced it, which is the reviewer's addition to this card - runs each suite under `python3 -B`, refuses a tree with no test_*.py (CI-01's rule, for CI-01's reason), and fails if a cache appears during the run. It takes the tree as an argument so the infra repo's replay harnesses can call it without being moved. WHERE IT IS SAID (AC 2). MUTATION.md carries the mechanism, the measurement, the reporting rules and the survey, and every one of the 16 suites now points at it from its docstring. That list is DERIVED FROM THE TREE by test_bytecode.py part 5, so a new suite that joins this directory without the pointer is red - the same failure shape CI-01's file glob exists to prevent. CI WAS ALREADY IMMUNE, AND IS DESCRIBED THAT WAY (AC 4). Verified rather than reasoned: with the checkout bind mounted `-v "$WS:/w:ro"` the interpreter writes no __pycache__ into the tree at all, and it fails SILENTLY - no error, exit status 0 - while the same probe on a writable mount produces one. Each job also rm -rf's its workspace and clones afresh, so nothing crosses between jobs on the shared runner. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces only: the `:ro` is one character wide and the next person debugging a write will be tempted by it. Part 6 grades both ON THE DOCKER COMMAND LINE rather than on the file - the first draft searched the whole workflow and stayed green after the flag was deleted, because the comment explaining it still named it. THE SHIPPED ADD-ON IS NOT AFFECTED and the question is closed: goodwe_controller/Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was written. There is no deploy-side finding. THE SURVEY (AC 3), in MUTATION.md, scoped BY THE PROPERTY. The defect is one-directional - a mutation that never took leaves the suite green, so stale bytecode manufactures SURVIVORS and cannot manufacture a red - which puts every "all red, no survivors" claim in the window out of scope, along with mutations executed in-process (SAFETY-07's B1/B2/B3, test_peakguard parts 7 and 10, where no source file is edited) and everything run after the purge discipline landed on 2026-08-31 (SAFETY-24, SAFETY-26, OPT-04, FCST-03's re-run). What is left is the recorded SURVIVORS from source-edit runs before that date. Two were re-run here under the harness and both still stand: TARIFF-01's record_block() ignoring its policy argument, and SAFETY-03's abs() on the clamp limit - 15 suites green each, on the tree as it stood. The rest are labelled still-unverified rather than assumed or re-run; each is one harness run to close, and the moment to spend it is when somebody next touches that module. OUT OF SCOPE AND RECORDED: the infra repo's sim/ replay harnesses import the add-on and write bytecode into both trees (goodwe/sim/__pycache__ exists today), so SAFETY-02's headline replay carries the same exposure. mutation_run.sh takes a tree argument for exactly that, but the change belongs in that repo and some of those harnesses want the rig. RED AND GREEN. Every new check was broken and watched fail: the purge commented out of the harness turns part 4 red (and its non-vacuity probe already proves the fixture would mis-grade without it); one docstring pointer removed turns part 5 red naming the file; `:ro` and the `-e` flag removed from the workflow turn part 6 red. Full suite green, 16 files, in the CI image on a read-only mount - the shape the runner uses. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
04292c4a08 |
DATA-01: thirty days of the real meter, and what AC 3 actually measures
checks / unit (pull_request) Successful in 3m36s
TARIFF-01 and SAFETY-07 both merged with AC 3 - "monthly peak held under
the soft limit in >= 95 % of intervals over a 30-day simulation replay" -
honestly unmet, because two days of capture existed and it was believed
nothing longer could be produced. That belief was a true statement about
the past read as a claim about the future: HA's recorder still held the
whole month, and the reason nobody found out is that the 2026-08-25
export was a one-off script that left no artefact.
So the exporter is committed and runnable now.
scenarios/p1-net-30d-2026-08/ is 2026-08-01 to 2026-08-30, 485,841
samples, 30/30 days read, 0 failed, 4.13 MB gzipped, in the schema the
two committed days already fixed.
VERIFIED AGAINST THE DAYS THAT EXIST. `--verify` re-fetches 2026-08-20
and 2026-08-23 by this exact route and reproduces both committed files
BYTE FOR BYTE after decompression (865,024 B / 15,600 samples and
894,387 B / 16,351 samples). The gzip containers differ by design: this
exporter writes mtime 0 so its output is reproducible, where the one-off
wrote a wall clock.
A FAILED READ IS NOT AN OBSERVATION. A day whose read fails writes no
file, is recorded "read": "FAILED", and the run exits non-zero; the
entity is proved to exist through /api/states before any empty day is
believed, because a typo would otherwise answer 200 [] thirty times and
produce a consistent dataset of nothing. Nothing is interpolated, so the
month's 13 gaps (1291 s, 99.95 % covered) and its 3 `unavailable`
samples stay visible as holes.
SIZE: COMMITTED, DELIBERATELY, AND MEASURED. A git bundle of the whole
history goes from 1.58 MB (release/1.0 @
|
||
|
|
9234016419 |
Merge release/1.0 (OPT-04) into SAFETY-24, and fix one grader the merge broke
checks / unit (pull_request) Successful in 3m36s
OPT-04 landed after the previous rebase. Conflicts were CHANGELOG.md and one IMPORT LINE in validate.py; both refusal blocks and both option sets survive untouched, and DOCS.md, main.py and config.yaml auto-merged. ⚠️ AND THE MERGE BROKE A CHECK THAT NEITHER CARD COULD HAVE SEEN ALONE. test_peakguard.py graded "the first `.decide(` call in main.py" and asserted there was exactly one. That was true when SAFETY-24 was written; OPT-04 added `arbitrage.decide(...)`, so the merged tree had two and the assertion failed. It failed loudly rather than grading the wrong call - the guard did its job - but it cannot ship red. Fixed by selecting the call by QUALIFIED NAME (`peakguard.decide`) instead of by position, and requiring exactly one of THAT. Other modules may now call their own decide(); this grader can no longer be moved by one of them. Verified still discriminating: a decoy `peakguard.decide` added to main.py turns it red on 7 assertions, and the `maintenance_soc_floor` swap still turns it red on 6. Also folded in the review's wording finding. An assertion read "a CONTROLLER whose SoC entity does not answer hands decide() None" while driving no Controller. The wiring property is stronger than the one claimed, and is now asserted on the SERVICE CALL: a Controller with no SoC never reaches the guard at all, because `inputs_ok` is False and cycle() stops at the safety claim first - so a `float(soc or 100)` defaulting line above the call site cannot disarm the floor. The original decide()-level check is kept, reworded to say what it actually grades. Full suite green on the merged tree: 15 files. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
e709554857 |
SAFETY-24: an energy floor under the peak guard's forced discharge
checks / unit (pull_request) Successful in 3m29s
SAFETY-07 can command a discharge to hold a billed quarter down, and nothing below it consulted the state of charge. On the 2026-08-20 replay it asks for 878 Wh in a day. Relying on the BMS is not absurd - it is a real floor and it works - but it is the pack's protection rather than the operator's, and a month of aggressive quarters leaves the battery repeatedly at that cut-out with no EMS-side record of why. The first symptom is a pack never available when wanted, which is indistinguishable from the SoC drift MAINT-01 exists to correct. decide() now takes soc and soc_floor, both required and neither defaulted, and discharge_permitted() is the one place the question is answered. Above the floor nothing changes. At or below it the guard files a 0 W floor instead of a sized one - one-directional, so charging stays blocked and no discharge is capped - and reports floor_limited with the reason it bound. It is not a trip: every stop in 11.2's table still outranks the claim, and the floor is never negative, so 9.1's asymmetry survives as a property of the object (0 negative floors over 1296 swept combinations, SoC included). The SoC is graded only after `wanted > 0` is established, so it is never evaluated where it governs nothing. An unreadable SoC is floor-limited, not a full battery - a full battery is exactly the value that would disarm the floor, and this project shipped that defaulting once already. Failing to shave is not silent: one notification per episode (goodwe_peak_soc_floor), distinct from the saturation alarm because the two ask for opposite operator actions, plus its own status row and an action-log line. Verified by replay. The 2026-08-20 capture is driven against a modelled pack sized from the day's own measured appetite, so it genuinely exhausts: without the floor it reaches the BMS cut-out and holds there for 1227 guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The energy withheld equals the energy between the two floors to within one cycle at the rail. The honest half is reported too - the worst quarter goes 4338 W -> 5030 W, because a floor-limited guard shaves less on purpose. Two new options, mirrored once in peakguard.PEAK_OPTION_DEFAULTS (TARIFF-02's pattern), imported by validate.py and main.py rather than typed as literals and pinned to config.yaml by a check that reads the file - so CFG-03 still tracks three places. validate.py rule 8 refuses peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner. maintenance_soc_floor is deliberately not reused and not renamed: it is a drain target, not a spend limit, and the rename is recorded as a decision to revisit if a third floor appears. Eleven mutations of the shipped source were run against the checks; all eleven go red and there are no survivors. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
2d570d84ce |
SAFETY-07 review: defend the three wiring mutations that survived
The reviewer's finding was correct and the shape of it matters: everything the
first cut graded was in peakguard.py, and grading the module is not the same as
grading the guard. Three one-line changes to main.py's CALL SITE left all twelve
suites green while a default install parked at 0 W in the quarter that sets the
month's bill.
B2 was the serious one. My own comment described that defect - "that entity is
optional and empty on a default install, so until now the suspension could not
fire on the site that needed it" - and nothing could regress it. A comment that
documents a fix nobody can test is the same shape as a corrected comment nobody
tests, which this project has already been caught by once.
WHAT CHANGED
The suppression conjunction moved out of main.py and into
peakguard.shaping_suspended(), for the reason watchdog.loop_is_following() and
freeze.looks_frozen() live where they do: the check that grades a safety
predicate must assert on THE SHIPPED EXPRESSION, not on a transcription that can
drift apart from it in silence. Its docstring carries both terms and why neither
is sufficient alone. main.py's call site now says READ THAT FUNCTION FIRST, and
records that a reviewer mutated it back to its historical broken form with every
suite staying green.
test_peakguard.py part 7 gains a section that EXECUTES the three mutations
rather than describing them. Each one is put in place on the shipped module and
the REAL Controller.cycle() is driven with it, on the dangerous fixture: a
default install (no peak_forecast_entity, so peak_fc is None and peak_at_risk is
False forever) with maintenance in its CHARGE phase, so a P_MAINT_SHAPE `hi <= 0`
limit is live, and the guard genuinely engaged on the measurement. That the
mutations are monkeypatched onto the shipped module is itself load-bearing: if
main.py inlined either expression again the patch would do nothing and these
checks would pass vacuously.
SHIPPED suspended=True loop -> 1498 W, limited by peak +1497.8 W
B1 suspended=False CONTRADICTION between limits 0.0 W
B2 suspended=False CONTRADICTION between limits 0.0 W
B2b (forecast term dropped instead) - caught by its own check
B3 is graded three ways, because the single-cycle form is only INFLATED and the
failure is what happens on the next cycle:
* the value main.py actually hands decide() is recorded off the real call, with
the measured battery at 0 W and the command standing at +3000 W;
* the one-cycle difference is asserted to be exactly the standing command - the
whole defect in one line, watts that were asked for and never arrived counted
as if they had;
* both forms are then run forward against the REAL controller's own projection
with an inverter that never follows:
intent-sized floor 4482 5000 5000 5000 ... SATURATED at cycle 2
delivered-power floor 1482 1482 1482 1482 ... stationary
* and the call site is graded on parsed syntax, so a rename cannot quietly
reintroduce it: `decide(batt_w=...)` must unparse to `self.batt`.
SAFETY-24 is now named in peakguard.py, in its own section, with the number that
makes it real - 878 Wh of forced discharge on the 2026-08-20 replay - and the
statement that this must not go to a client install before that ticket lands. A
ticket nobody can find from the code is a ticket nobody reads before shipping.
RED AND GREEN
Fifteen mutations run against the shipped modules, each reverted after: the six
new wiring ones (B1, B2, B2b, B3, B3b, and deleting the SAFETY-24 pointer) and
the eight from the first round, re-run to confirm they still bite. All fifteen
turn test_peakguard.py red. Full suite green, test_price.py and TARIFF-03's
included.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
616b62d3e9 |
SAFETY-07: cap the loop before it sets the month's billed capacity peak
checks / unit (pull_request) Successful in 3m7s
TARIFF-01 measured the quarter and said the consumer would be this card. It is
one new module, app/peakguard.py, and one new claim.
THE MECHANISM. Every cycle the guard projects the open 900 s block to its
end-of-interval average - from P1 telegrams only, never from the command - and
compares it to a ceiling. Over the ceiling it files ONE arbiter claim: a lower
bound on the setpoint at P_PEAK. That single shape is both behaviours 10.1 asks
for, a hard clamp on charging and pre-emptive discharge, and it cannot cap
discharge or export, because a floor cannot. 9.1's asymmetry becomes a property
of the object instead of a rule to remember.
excess = 900 x (projected - ceiling) / seconds remaining
floor = MEASURED battery power + excess
The 900/remaining gain is 1.0 at the top of the quarter and grows, so the guard
is gentlest where its projection rests on the least evidence. The floor is sized
from delivered battery power, not the standing command: a floor built on intent
re-adds its own unmet ask every cycle and winds to the rail whenever the inverter
fails to follow, and test_peakguard.py part 1 shows the two diverging.
IT TRIPS, AND THE CAPTURES DECIDED THAT. On the healthy reference day it engages
on zero of 95 quarters. The action is level-triggered, unlatched and re-derived
every cycle, so a false engagement costs one cycle of discharge rather than a
parked battery - the cost SAFETY-18 could not bound and this one can. Replayed on
2026-08-20 the billed quarter goes from 5029.8 W, above the inverter's own 5000 W
rating, to 3485 W, under the soft limit and without saturating. Quarters under
the limit across both committed days: 189/190 -> 190/190. Two days is not thirty
and AC 3 remains TARIFF-01's open item.
BLINDNESS IS CHECKED BEFORE THE PROJECTION IS GRADED, and it is a different
action. A fresh averager projects a confident 0 W, which is under every ceiling
there is; a meter gap longer than meter_max_age_s makes the projection read LOW;
a frozen meter reading export projects 0 W at full coverage. All three become a
floor of 0 W - no importing while the billed quantity is unobservable - which is
one-directional and cannot cost pack energy. That is the backstop SAFETY-18 could
not be: its alarm arrives at 300 s of a 900 s quarter and commands nothing. The
frozen term is freeze.looks_frozen() itself, on this cycle's standing command.
THE CEILING IS peak_cap_w, RAISED ONLY BY AN OBSERVED READING. NO_RECORD and
NOT_OBSERVED both leave it at the cap, so an unreadable peak store makes the
guard stricter and never looser. The gate is the reading's STATE, not whether a
number happens to be attached: today a `peak_w is not None` test behaves
identically, and depending on that coincidence is how a future last-known-peak
field would raise the ceiling off a read that failed. headroom_w() is
deliberately not consumed - cap minus peak turns a zero peak into FULL freedom.
TWO DEFECTS FOUND BUILDING IT, both in the interaction rather than the
arithmetic, and both caught by running the thing rather than by reading it:
* A LIMIT does not out-vote another LIMIT. arbiter.resolve() applies every
limit at or above the winner's priority and takes the most restrictive, so
the peak floor (lo >= 0) and the maintenance charge-only shaping (hi <= 0)
resolved to a CONTRADICTION and 0 W - the battery parked in the exact quarter
it should shave. Fixed by suppression, not priority: main.py drops the
maintenance shaping while the guard is engaged, which is what that branch
already did for the optional peak_forecast_entity - a key empty on a default
install, so until now the suspension could not fire on the site that needed
it.
* Thresholding `excess > 0` released the claim the instant it began working,
producing seventeen engage/release cycles in one 900 s quarter and leaving
that quarter 49 W over the limit it had spent fifteen minutes holding. That
is 10.2's oscillation. The threshold is now the floor itself, which is the
same arithmetic read as a level rather than as a switch.
PeakTracker.project() no longer reads a private name with a default.
getattr(averager, "_last_net", 0.0) failed quiet AND disarming - a rename credits
0 W held, the projection reads low, the money guard does not engage.
QuarterAverager.held_net_w is a documented public property now, read without a
default, and Projection carries it. TEST-13 item 4.
NO NEW OPTION AND NO FOURTH DEFAULTS SITE. The ceiling is peak_cap_w, the
coverage threshold is meter_max_age_s, the freeze predicate is meter_freeze_s,
and the achievable discharge comes from max_w and the device rating. config.yaml
and validate.py are untouched; 14's capacity_peak_limit_kw stays declined. On
meter_source: off there are no telegrams, so the guard does not run at all and
the status page says NOT COVERED - running it there blinded it permanently and
stopped every legacy install from charging, which is what the first cut did until
test_clamp.py's export case caught it.
test_peakguard.py: eight parts, all figures derived from the shipped config.yaml
and the committed captures. Part 8 runs seven one-line defeats of the guard and
reports which check bites; six do, and the seventh is reported as NOT caught,
because max(cap, peak) makes a zero peak the strictest ceiling there is and there
is nothing left to catch.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|