Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py
Co-Authored-By: Claude <noreply@anthropic.com>
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.
Co-Authored-By: Claude <noreply@anthropic.com>
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.
Co-Authored-By: Claude <noreply@anthropic.com>
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.
Co-Authored-By: Claude <noreply@anthropic.com>
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.
Co-Authored-By: Claude <noreply@anthropic.com>
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>