Commit Graph
11 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 23a3a3f5b5 UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified
  as data or as a built text, and every built text is produced by the real
  code and checked. This is the gap the 2d scan had: it counted `%s` as one
  word, so reasons built by loop_clamp_note() and friends were never seen.
- Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept):
  OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak
  guard (codes now PEAK_GUARD*), the migration report, price feed, price
  history and gate reasons. Plurals via messages.times()/count().
- Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff
  "one every 15 minutes or every hour", "not final yet" dropped.
- Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO,
  aiohttp access log only at log level debug, settings warnings once per
  start, one plain line per Home Assistant outage (hass.Outage).
- INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE",
  "NOT_OBSERVED", "did NOT land", "AND".
- Display bugs: WHY_WINNER covers every winner and safety reason
  (main.why_key(), part 7 finds them in the code); the meter row is amber
  "waiting for the first reading" inside its limit after a start; the
  missing-reading age is counted when the page asks.
- STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section).

No change to safety behaviour, alarm levels, notification ids, triggers,
cadence or the banner cascade. One row colour changes (meter at start),
justified in DECISIONS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 10:58:43 +02:00
adminandClaude Opus 5.5 6a95447248 UX-08 2d: plain log lines, the rest of the status page, and DOCS
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m55s
Every WARNING and ERROR line is one plain line of at most 25 words, with
no card ids, capitals or semicolons; the reasoning of the ten longest is
on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0).

The status page: the month-peak and peak-guard rows, the stale-reading
row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the
Stopped banner and the line under the buttons, which now shows the plain
hint of each event instead of the raw action log. The Supervisor question
at start logs one line with a real reason.

Refusals are counted as shown (labels expanded, long cases driven), seven
were shortened, the card and parse errors lost their internals, a blank
value reads "empty", and the panel no longer files inverters.max_w under
the flat max_w. Option names lose "(JSON)", the NL texts are checked too.

DOCS gets a glossary (control board, isolator, Developer Tools) and card
ids move from headings to a "For installers" line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 08:01:16 +02:00
glenn schrooyenandClaude Opus 5 d1b7e3f113 SAFETY-44: decide per key, because one shared flag let an unrelated latch veto the repair
checks / unit (pull_request) Successful in 6m58s
⚠️ REVIEW DEFEATED THIS CARD'S OWN FIX WITH ONE ADDED KEY, and the project's own
instrument agreed on the unmodified tree. The guard classified each key and then
wrote ONE site-wide `namespaced_latched` for BOTH "on the roster" and
"off-roster but not UNIT_A", so a single latched key belonging to a unit the
operator had removed from `inverters:` vetoed the repair of the misdirected
`inverter-a` latch beside it. Measured, roster ['garage','shed'], store stamped
so the migration fix cannot reach it:

  sign_tripped + unit/inverter-a/sign_tripped     -> [('garage', True),  ...]
  ...AND unit/old-shed/sign_tripped               -> ⚠️ [('garage', False), ...]

A site DRIVING on a state file that reads `sign_tripped: true` - the sentence in
this card's own first paragraph - and `tools/rehearse_roster.py` printed
`LATCH CAME UP DISARMED` on it, exit 1, against shipped code. It matters more
than a normal hole because this guard is, as main.py says, the ONLY repair path
for an install already stamped by 0.9.0.

⚠️ AND IT IS INSTANCE #17 OF HABIT 4, IN THE EXTENSION MUTATION.md ADDED TWO
DAYS AGO. The two fixtures written for this card each hold ONE arrangement -
`_staged_store` has only `inverter-a`, `_other_store` only `inverter-b` - so the
flag was never written twice with opposite intents in a single store. A per-key
check whose keys have never disagreed WITHIN ONE STORE is a check over whichever
key came last. Three variables now, one per case, and a fixture holding BOTH.
Four cases driven: stranded-only repairs, +1 unrelated repairs, +2 repairs,
off-roster-only does NOT (which is DEV-02's control, still green).

⭐ AND THE MOVED-NOT-LOST RULE HID A GENUINE LATCH LOSS. The match was bare key
plus value over the whole of `machine_read`, with no identity - and
`DEFAULTS["sign_tripped"] is False`, so the ONLY non-default value a latch can
hold is `True`. Any surviving latched roster unit therefore suppressed any other
unit's vanished latch. Review measured a build that drops `unit/shed/sign_*`
while `unit/garage/sign_*` survives, both latched by one site event so the
reasons matched too:

    none in LEG SAME-STEP: nothing vanished, nothing stranded ...
    NO FINDINGS in the rehearsed transitions            exit 0

A roster unit's persisted SAFETY-02 latch deleted, transition reported clean.
The legitimate case is a RENAME - the key left `inverter-a`, which is not on
this roster, and arrived under `garage`, which is - so the vanished key's own
unit must be OFF the roster. A key whose unit is still on the roster has not
been renamed, it has been lost, and no amount of the same value elsewhere makes
that untrue.

⚠️ AND THE BOUND I CITED FOR IT DID NOT EXIST. Both the comment and the last
commit message said "what M3 (delete the flat rollback view) measures". M3 is
not that mutant - it drops `sign_reason` from `LEGACY_UNIT_KEYS` - and the one I
meant, M9, vanishes only FLAT keys, so neither can satisfy the `unit/` gate the
rule sits behind. NEITHER EXERCISED THE BRANCH; it had no negative control at
all, in a card whose subject is checks that cannot reach the failure they name.
A citation is the worst carrier for that, because it reads as having been
checked. M12 is written for it and driven: a roster unit that stops restoring
its latch is exit 1, and the suppression does not swallow it.

`misdirected` IS UNREACHABLE FROM THE CALL SITE, and the claim that it was a
benefit is withdrawn rather than restated. `unit` is `roster_names(opts)[0]` and
`build_roster()` names its first entry from the same list, so `unit` is a member
of `roster` by construction; review measured it - dropping the `roster` argument
inside `migrate_unit_keys()` survives 28/28. The argument stays for the reason
`_verify_moves()` gives for its own `roster=None` branch, it is what a NEW
caller gets - and a guard nothing exercises is a guard nobody knows works, so it
is now exercised at the function's own level: a wrong `unit` comes back
misdirected, the marker is not stamped, and the same call with a roster name
stamps it. Dead `if _roster_names else UNIT_A` removed; `roster_names()` never
returns [].

THE OPERATOR MESSAGE IS ASSERTED. Review deleted it whole (`if stranded:` ->
`if False:`) and 28/28 stayed green - `stranded` had no other consumer, so the
list existed only to print a line nothing checked, and that line is the entire
operator-facing half of the repair. Now: exactly one SAFETY-44 line at ERROR,
naming the stranded key and the roster it was measured against.

A wrong line citation removed: the call-site comment said "line 315's comment"
and "two hundred lines below", and both were wrong (315 is the CFG-03 defaults
note; the comment meant is ~54 lines down). Cite the thing, not its coordinates.

⚠️ AND WHAT 5b/5c ACTUALLY PIN IS RECORDED, because review is owed the
distinction: `mutant_tree()` asserts its target exists, so EDITING the guarded
line makes the file red at the ANCHOR before any behaviour is measured - which
looks identical from the exit code and proves much less. It happened twice while
writing this commit. The behavioural coverage lives in test_maintenance.py
section 13 and test_inverter.py, which build stores rather than strings.

Fixture strings no longer say "measured" - they are synthetic, and the repo's
other fixture carries an explicit SYNTHETIC header.

28/28 files pass.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-08 17:08:41 +02:00
glenn schrooyenandClaude Opus 5 5e382f52f6 SAFETY-44: the latch migration takes the roster, and the guard stops being defeated by the key the defect wrote
checks / unit (pull_request) Successful in 6m56s
⚠️ A DISARMED SAFETY-02 GUARD ON AN INSTALL WHOSE STATE FILE SAYS IT IS
PROTECTED. `Controller.__init__` called `migrate_unit_keys(store, UNIT_A)` - a
hardcoded constant - while its sibling `migrate_maint_keys(store, unit, roster)`
takes the roster and refuses a write no machine reads. On a store that ran
pre-DEV-02 flat and declares `inverters: [garage, shed]`, the latch moved to
`unit/inverter-a/sign_tripped`, `_verify_moves()` read it back under the name it
had been HANDED, was satisfied, and stamped the marker. Not one inverter came up
latched, and the next start skipped the migration too.

That is the MAINT-05 defect verbatim, still live in the function whose own
docstring describes it, and `_grade_store_migration()` did not catch it: its
"is anything namespaced latched" test was satisfied BY THE MISDIRECTED VALUE
ITSELF.

⚠️ THE REASON IT WAS LEFT WAS A HALF-TRUTH. "There is no roster yet - the
`Inverter`s restore their latch in their constructors." The KEYS must be written
before the `Inverter`s read them; the NAMES do not come from the `Inverter`s.
`roster_names(opts)` reads them off the options before anything is constructed -
which is exactly what it already existed to do for `MqttPublisher` - and returns
`[UNIT_A]` on the flat shape, so today's upgrade path is byte-identical.

TWO EDITS, AND THEY DO DIFFERENT JOBS. Measured per leg by reverting each one:

                          SAME-STEP leg          STAGED leg
  both edits (shipped)    clean                  latch armed, litter reported
  guard reverted          latch armed            ⚠️ DISARMED
  call site reverted      latch armed, litter    latch armed, litter

So the GUARD carries the safety and the CALL SITE carries the hygiene and the
withheld marker. The table is in test_rehearse.py part 5 because a reader who
assumed the roster-aware migration re-arms the latch would delete the guard as
redundant in a tidy-up and take the STAGED column with it - and STAGED is what
"upgrade now, declare the roster later" produces, which is the path an operator
actually takes. Only the guard reaches an install already stamped by 0.9.0.

⚠️ AND "OFF THE ROSTER" ALONE WAS TOO BLUNT, WHICH test_inverter.py CAUGHT. The
first draft treated every off-roster latch as litter. In DEV-02's restart case
the store carries `unit/inverter-b/sign_tripped = True` from B's own trip while
the roster being graded holds only A - and the blunt rule re-armed a HEALTHY A
off the flat key B's trip had mirrored. DEV-02's defect rebuilt inside its own
guard, which is what the paragraph I was overruling had been right to fear.

Narrowed to `UNIT_A`, which is the only name the broken migration ever wrote -
`roster_names()` falls back to a POSITIONAL `inverter-N`, so `inverter-a` is not
a name this code hands to anyone else. A latch stranded under any other name is
a real unit out of today's config and still counts as protection. Residual,
stated in the code rather than left to be found: a site whose own first unit is
NAMED `inverter-a`, latched, then taken out of the roster gets re-armed on
`inverters[0]` - a healthy unit held at 0 W until an operator clears it. The
conservative direction, against a site DRIVING on a file that says it is latched.

⭐ AND FIXING THE CODE EXPOSED A FALSE POSITIVE IN THE HARNESS. With the latch
now landing under `garage`, `rehearse_roster.py` reported VANISHED STORE KEY for
`unit/inverter-a/sign_tripped` three lines above the same value sitting under
`unit/garage/sign_tripped`. A key that moved to a namespace a machine reads has
not vanished - and an alarm that fires on the harmless case is one an operator
learns to dismiss before the real one arrives, which is CONTROL-C's own
argument. The test is not "the name appears somewhere": same bare key, same
value, under a key in `machine_read`, the set built by driving a real start. A
latch that genuinely went missing has no such key and is still a finding, which
M3 (delete the flat rollback view) still measures red.

Test parts replaced deliberately, as both of them asked to be:
  - test_rehearse.py part 5 asserted the defect "as REQUIREMENTS so that a fix
    turns them red". It now asserts the fix, with 5b and 5c as negative controls
    - one per edit - and 5b doubles as the leg-splitter's positive control,
    since reverting the guard is the build where the two legs DISAGREE.
  - test_maintenance.py section 13 was headed "RECORDED, NOT FIXED" and said the
    fixing card "should expect them to go red and should replace them". Replaced,
    plus two cases it could not have had: the already-stamped store, and the
    `inverter-b` negative control for the narrowing above.

28/28 files pass. Not run: nothing - this is host-side only, no rig, no hardware.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-08 15:36:37 +02:00
glenn schrooyenandClaude Opus 5 a9993aeda2 SPIKE-04a: inverter B is 4600 W FROM ITS DATASHEET, and the copies are pinned
checks / unit (pull_request) Successful in 4m51s
The desk half of SPIKE-04. No control behaviour changes; this is documentation
and the check that stops it drifting again.

Three places stated inverter B's rating - config.yaml's commented roster
example, DOCS.md's, and tools/supervisor_shape_probe.py's "a blob an operator
would POST" - and all three said 3000 W, a number nobody had measured or read
off anything. The owner supplied B's model and serial on 2026-09-04: a GoodWe
GW5048D-ES, serial `55048ESU22AW0992`, max charging and discharging power
4600 W. Serial characters 6-8 are `ESU`, platform 105 / AA55, so SPIKE-01 does
not gate this site. All three copies now read 4600.

⚠️ 4600 W IS FROM A DATASHEET AND IS NOT A MEASUREMENT, and the one ambiguity
is recorded rather than guessed. The datasheet prints it under BATTERY INPUT
DATA, so it is probably DC, while max_w is graded against 0x0518 - the
inverter's own AC power. If it is DC the AC ceiling is nearer 4324 W. Neither
reading is written in as fact; SAFETY-20's min(max_w, dev_max) already bounds
it correctly under either, once dev_max is read off the unit, so `max_w: 4600`
is what an operator should configure today. goodwe/NOTES.md §1.1b carries the
full record with the date and the method on every figure.

A NEW CHECK, BECAUSE A DOCUMENTATION FIX WITHOUT ONE DRIFTS AGAIN.
test_validate.py now pins all three documented rosters: findable, in agreement,
and equal to 4600 - with an explicit len(...) == 3 guard so that a regex which
stopped matching cannot leave "they all agree" green on the two sites still
read. It also grades the PROVENANCE beside the number (the datasheet, the
0x0518 it is graded against, and the 4324 W the DC reading would make it)
WITHIN 2500 characters of the roster rather than file-wide.

⚠️ The first version of that provenance check searched whole files and was
ALREADY VACUOUS on two of them: 0x0518 appeared once in config.yaml and once in
DOCS.md before this card, for unrelated reasons, so `"0x0518" in src` was green
no matter what happened next to B's rating. That is a check whose data cannot
reach the failure it names, in the file that exists to complain about them. It
is fixed, and the window is what fixes it - deleting the caveat beside the
number now goes red even where the same token survives elsewhere in the file.
The windowed version immediately found that the DOCS.md caveat did not name
0x0518 at all; DOCS.md now says it.

Four mutations, bytecode purged and counted at 0 before and after each, all
RED (two of them 0-byte deltas that change a printed answer):
  M1  probe's operator blob 4600 -> 3000        0 B   RED (value + agreement)
  M2  DOCS.md's DC/AC caveat deleted         -157 B   RED (provenance)
  M3  config.yaml alone 4600 -> 4324            0 B   RED (agreement)
  M4  probe entity renamed, regex finds nothing       RED (the vacuity guard)
Restored, green again. The probe itself was re-run against Supervisor
2026.08.0's own AppOptions validator with the 4600: all cases passed, exit 0.

⚠️ THE TEST FIXTURES KEEP 3000 W ON PURPOSE AND NOW SAY WHY AT THE LINE.
test_inverter.py, test_maintenance.py, test_peakguard.py and test_watchdog.py
build a second inverter at 3000 W against A's 5000 W. The only property those
checks consume is that B's number is unmistakably not A's, and the real pair is
a 400 W gap - narrower than slew_w, inside the range where an off-by-one-unit
bug and ordinary control arithmetic produce indistinguishable numbers.
Collapsing them onto the real values would buy realism those checks do not use
and cost them their separating power, which is exactly what test_peakguard.py's
own §10g PRECONDITION exists to prevent. Their comments no longer call 3000 W a
hypothesis about B's rating; they call it illustrative, and not a placeholder
either - the placeholder era ended on 2026-09-04.

Also recorded in the changelog for the cards that own them: 94 % battery-to-AC
=> ~88 % round trip => ~360 W burned continuously to circulate 3 kW, which is
the number SAFETY-31 argues its threshold from without having one; < 13 W night
self-consumption per unit, which nothing accounts for; and the A/B asymmetry in
opposite directions (~33 % more energy, ~8 % less power), which means MAINT-05's
12 h drain timeout was derived on A and should be re-checked against B.

⚠️ Honest survivors:
- goodwe/NOTES.md §1.1b, where all of this is actually recorded, is graded by
  nothing here. Rewriting its 16 occurrences of 4600 to 3000 and turning every
  FROM DATASHEET label into MEASURED ON THE UNIT leaves all 19 files GREEN.
  This CI cannot fetch admin/goodwe - private, and GITHUB_TOKEN is minted for
  this repository only, as .gitea/workflows/checks.yml already states - so the
  cross-repo check is not buildable here.
- No check can see whether 4600 is the RIGHT number. Everything above pins a
  datasheet reading against itself. Only the bench half of SPIKE-04 can say
  whether the unit agrees, and the DC-vs-AC ambiguity is the live example.
- The constant is still named B_RATING_HYPOTHESIS in four test files, which
  reads as a hypothesis about B's rating when it is now an illustrative
  fixture. It is left alone deliberately: renaming ~20 sites across
  test_peakguard.py and test_inverter.py would collide hard with the open
  SAFETY-32 pull request, which rewrites 1255 lines of the first. The comment
  directly above each definition says what the value is and is not.

Suite: 19/19 green in goodwe-addon-ci, mounted :ro, bytecode purged and
verified 0 before and after.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-04 22:19:31 +02:00
adminandClaude Opus 5 905b6fd2b3 MAINT-05 fix round 2: the refusal has to survive the NEXT start, and both marker guards have to be visible
checks / unit (pull_request) Successful in 5m14s
REJECTED because the fix round's own load-bearing sentence was FALSE, and the
whole suite was blind to that. `_verify_moves()` produced the red the reviewer
reproduced - that half stood - but DECISIONS §2 claimed "`ok` gates the marker,
so a misdirected migration is not stamped and the next start runs it again ...
a re-run is recoverable". THE REFUSAL LASTED EXACTLY ONE START.

MEASURED, Controller level, ONE persisted store, roster ["garage","shed"], flat
last_completed 2026-08-07, call site still handing `inverter-a` on both starts:

    construction 1: ok=False misdirected=4 moved=4 kept=0   marker=<absent>
    construction 2: ok=True  misdirected=0 moved=0 kept=4   marker=1
    history parked under unit/inverter-a/...; marker stamped after ONE restart.

WHY. `_verify_moves()` graded only `rep.moved`. On start 2 the same wrong call
site finds the four keys already present, so rule 1 routes every one of them to
`rep.kept`, `rep.moved` is EMPTY, the roster loop iterates over nothing,
`misdirected` is empty and `ok` is True. Start 3 then takes the
`from_version >= MAINT_SCHEMA_VERSION` early return FOREVER - including after
the call site is fixed. Loud-and-recoverable became silent-and-permanent after
one restart: the exact state store.py's header says must never happen, reached
by the fix written to prevent it.

WHY THE CHECK MISSED IT - the recurring defect, this time INSIDE the remedy.
Part 9b's recovery check was `migrate_maint_keys(_m5, ROSTER[0], ROSTER)` - the
CORRECTED name. It measures recovery along the one path where the operator has
ALREADY fixed the bug. Nothing in the 19 files called `migrate_maint_keys()`
twice with the SAME WRONG `unit`. The check was true and passed for the wrong
reason.

WHAT CHANGED

1. app/store.py `_verify_moves()` grades `set(rep.moved) | set(rep.kept)`.
   Sound by construction: every entry in both lists is a `unit_key(unit,
   legacy)` built from the SAME `unit` argument, so grading `kept` grades the
   same namespace decision `moved` does. A correct call site's `kept` entries
   sit under a roster name and pass; a wrong one cannot launder its namespace by
   having already written it. `migrate_unit_keys()` passes `roster=None` and
   returns before the loop, so it is untouched.

2. test_maintenance.py part 9c - THE CHECK THAT WAS MISSING. Two starts, SAME
   wrong unit, ONE store: the marker is still withheld on the second, the
   refusal names the same roster, the flat history is still there to recover
   from, and a third start with the CORRECTED name still gets a run (which a
   stamped marker would have made impossible). Its PRECONDITION asserts the
   SHAPE of the second report - `moved` empty, `kept` full - so it cannot
   quietly revert to grading 9b's path. Counterfactual beside it: the same two
   calls with the right name are accepted, then skipped as `already at schema`.

3. test_maintenance.py part 9d - THE OTHER GUARD ON THE SAME LINE, and a
   survivor nothing in the repository could see. `if rep.ok:` is
   `not lost and not misdirected`; every check that reached the marker did so on
   a store whose `kept` was empty, so

       if rep.ok:        ->      if rep.ok or rep.kept:        (+12 B)

   stamped the marker on a migration that LOST A MONTH OF HISTORY - defeating
   the older, settled `lost` guard as well as the new one - and ALL 19 SUITES
   WERE GREEN on it (measured at 65cddf3, purged, :ro). 9d's fixture is the one
   shape that separates the guards: two keys already namespaced (`kept`
   non-empty, the mutant's `or` fires) and two whose write the store drops
   (`lost` non-empty), `misdirected` empty throughout.

4. FOUND HERE AND CLOSED: THE SAME MUTATION ONE FUNCTION UP. `migrate_unit_keys()`
   - SAFETY-02's LATCH migration - gates its own marker the same way, and every
   check that reached it ran on a store with an empty `kept`. `if rep.ok or
   rep.kept:` at store.py:307 SURVIVED ALL 19 FILES. It stamps `schema_version`
   on a migration that DROPPED THE LATCH: the guard is off, the file still reads
   `sign_tripped: true`, and the store now says the migration finished, so the
   next start skips the one thing that would re-arm it. test_inverter.py part 10
   now drops the `sign_tripped` write BESIDE an already-namespaced
   `sign_reason`, with the accepted-baseline counterfactual. No source change -
   the shipped gate was right; nothing could see it. Mutation table 34 -> 35.

5. DECISIONS/MAINT-05 §2 CORRECTED. The paragraph that stated the false
   guarantee now states what was measured, why grading `moved` alone could not
   hold, and why the union is sound. §7 records the marker-gate hole found in
   `migrate_unit_keys()` and that it was closed. MUTATION.md gains habit 9 -
   "exercise a refusal a SECOND time with the SAME wrong input, not the
   corrected one" - and two survey rows.

MUTATION LEDGER - 11 mutations, ALL RED on the final tree, every run on a fresh
copy with the bytecode cache purged (entry count printed before and after) and
the tree mounted :ro so none could be written. Two were survivors BEFORE this
commit and both are recorded as such. Full transcript on the PR.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-04 19:40:51 +02:00
glenn schrooyenandClaude Opus 5 65cddf35f1 MAINT-05 fix round: grade the migration against the ROSTER, not against the name it was handed
checks / unit (pull_request) Successful in 4m47s
REJECTED because a survivor undoes AC 5, and it survived for the recurring
reason: two fixture values that must be distinguishable were EQUAL.

THE SURVIVOR. app/main.py:282 mutated from `self.inverters[0].name` to `UNIT_A`
left the full 19-file suite green. `inverter.UNIT_A == "inverter-a"`, and every
two-pack fixture in test_maintenance.py named its first roster entry
"inverter-a" - so the two expressions were the same string in every check that
existed. main.py's own comment made the distinction load-bearing and nothing in
the repository could see whether that comment was true.

THE FAILURE IS REAL. `build_roster()` names a declared roster's entries from the
config and numbers a nameless one POSITIONALLY (`inverter-1`), so "inverter-a"
is not even the fallback. On ["garage","shed"] with a flat last_completed of
2026-08-07 the mutant migrates into unit/inverter-a/, pack 0 reads back None,
and both packs come up believing they have never been recalibrated.

AND IT FAILED SILENTLY, which was the worse half: `_verify_moves()` read back
the keys it had just WRITTEN, under the namespace it had just been HANDED, was
satisfied, and MAINT_SCHEMA_KEY was stamped - so the next start skipped the
migration too. A postcondition that reads back the namespace it was handed
cannot detect being handed the wrong one.

WHAT CHANGED

1. THE POSTCONDITION IS GRADED AGAINST THE ROSTER. `_verify_moves()` takes the
   names the MACHINES read and reports a namespace that is not among them as
   `misdirected` - a new, differently-named failure from `lost`:
     * `lost` is "the store took the write and dropped it" - a storage fault,
       with a harmless-default case (a dropped `last_completed: None` loses
       nothing, because absent and never-recalibrated are the same statement);
     * `misdirected` is "the store did exactly as it was told, by a caller that
       was wrong". There is no harmless-default version of it - a write nobody
       reads is not information whatever its value - so it fails `ok` alone.
   `ok` gates the marker, so a misdirected migration is NOT stamped and the next
   start re-runs it. Asymmetric on purpose: a re-run is recoverable (rule 1
   makes it a no-op, rule 2 left the flat keys to recover from), a silent skip
   is not. Part 9b MEASURES the recovery rather than asserting it.

2. `migrate_maint_keys()` TAKES THE ROSTER IN PLACE OF AN `n_units` COUNT. The
   count was `len(self.inverters)` at the only call site, so the roster carries
   it, and a count beside the names is a second opinion about how many packs
   there are.

3. THE FIXTURES CAN NOW REACH THE FAILURE THEY NAME. Parts 9 and 11 run on
   ["garage","shed"], each behind a PRECONDITION check that the first name is
   not UNIT_A - so an edit that makes them equal again goes red instead of
   making the claims vacuous. Part 11's fixture date is relative to `now`, not
   a literal, so "history preserved" and "history lost" cannot converge as the
   file ages past `interval_days`.

MUTATION LEDGER - all red, purged tree, none at +0 B, full detail on the PR:
   M1  main.py  inverters[0].name -> UNIT_A            -16 B  4 checks red
   M2  store.py drop `roster=names` from _verify_moves -14 B  5 checks red
   M3  store.py drop the misdirected.append            -37 B  5 checks red
   M4  store.py ok: drop `and not self.misdirected`    -25 B  3 checks red
   M5  fixture  garage -> inverter-a (the trap itself)  +4 B  5 checks red
   M6  store.py parts[1] -> parts[-1]                   +1 B  1 check red

FOUND AND NOT FIXED - `migrate_unit_keys()` HAS THE SAME HOLE AND IT IS A LATCH.
It runs BEFORE `build_roster()` (each Inverter restores its latch in its
constructor), so it is handed the constant UNIT_A with no roster to grade
against. On a declared roster a pre-DEV-02 `sign_tripped: true` lands under
unit/inverter-a/sign_tripped, which no unit reads - and
`_grade_store_migration()`, whose whole job is to re-arm exactly this, is
DEFEATED BY THE KEY THE DEFECT WROTE: its "is anything namespaced latched" test
is satisfied by the misdirected value itself. Measured, with the flat-config
counterfactual, and pinned as a running check (test_maintenance.py part 13)
whose assertions state the WRONG behaviour on purpose. It wants its own card:
the remedy is in inverter.py and SAFETY-02's semantics, and a silent expansion
into a safety latch is how a rejected PR becomes a broken one.

Suite: 19/19 PASS, purged tree, bind-mounted :ro in goodwe-addon-ci.
No hardware was touched; every fixture here is SIMULATED and pack B's 3000 W
remains a marked hypothesis.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-04 16:18:34 +02:00
adminandClaude Opus 5 1aef19e995 MAINT-05: one recalibration per pack, and only one pack moves power at a time
checks / unit (pull_request) Successful in 4m48s
§12's monthly cycle drains a pack to empty and refills it to true its coulomb
counter. There was exactly one `Maintenance` and one un-namespaced history, so
at two packs only the first was ever recalibrated - and nothing prevented the
cycle draining pack A while the loop charged pack B, which is two power-moving
phases on one grid connection pulling against each other.

* ONE `Maintenance` PER ROSTER ENTRY, each with its own schedule, phase and
  history under `unit/<name>/...`. `store.migrate_maint_keys()` moves an
  install's flat history into the first pack's namespace under
  `migrate_unit_keys()`'s three rules - shared in code via `_move_flat_keys()`
  and `_verify_moves()`, not restated - on its own marker, because unlike
  DEV-02's it runs only where the roster has more than one pack. The flat keys
  are kept LIVE as the rollback view.
* ONE MAINTENANCE SLOT PER SITE (`maintenance.arbitrate()`). At most one pack
  in a power-moving phase - drain, charge AND hold. The holder is DERIVED from
  the packs' own stored phases, never persisted, so a restart mid-drain
  re-derives it. Several packs due in the same hour: the slot goes to the one
  that has gone longest without a completed cycle; roster order breaks a
  numeric tie and nothing else. Nothing preempts a cycle in flight.
* THE DEFERRED PACK IS NOT STARVED AND IS NOT A FAULT. A deferral does not
  stamp `last_start_attempt` and does not move the phase, so neither the 12 h
  drain nor the 36 h charge timeout is reachable by waiting.
* The claim is filed on the pack whose state machine produced it, and stays
  SCOPE_UNIT - ARCH-01's rule.
* `validate.py` rule 6 grades `maintenance_charge_w` against the WEAKEST cap on
  the roster now, as its own comment said it must once `maint_unit` stopped
  being `inverters[0]`.
* At a roster of one nothing changes, and it is asserted: no new store key, the
  migration does not run, the four cycle events are the shipped strings, the
  banner is the bare phase.
* RECORDED NOT FIXED: a drain pins its pack while the loop's target is a site
  claim, so below the pin the allocator refuses the split and the site parks at
  0 W. Pre-existing at 2d025ee. Pinned as a running check.

Verified: 19/19 suites green in the CI image; 17 mutations run through
tools/mutation_run.sh (bytecode purged), every one observed red.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-04 13:38:29 +02:00
glenn schrooyenandClaude Opus 5 d5b1ef19b3 CFG-03: give maintenance option defaults one source of truth
checks / unit (pull_request) Successful in 3m44s
Option defaults for the maintenance cycle were declared in three places that
could disagree, and MAINT-04 proved they already did. config.yaml shipped
`maintenance_charge_w: 2000`; main.py carried TWO `opts.get(..., 2500)`
fallbacks; MaintConfig's dataclass carried a third `2500.0`. So an options dict
with the key ABSENT was ACCEPTED by validate.py's rule 6 - which read 2000 -
and then built by main.py at 2500, against a 2000 W ceiling:

    options dict with maintenance_charge_w ABSENT, max_w=2000
      validate_startup_config  ->  []  (accepted, no problems)
      MaintConfig().charge_w   ->  2500.0
      arbiter.resolve()        ->  0.0 W, contradiction=True

That is the bug rule 6 exists to refuse, passing rule 6. It is unreachable on a
Supervisor install, which always supplies every key from config.yaml, and fully
reachable from sim/inject.py and from the test suite - which is where anyone
debugging maintenance actually works.

MAINT-04 shipped a TRIPWIRE and said so: test_validate.py pinned all three
literals and asserted the consequence through the real arbiter, so the
divergence could not silently widen or be half-closed. Its PASSING CONDITION
WAS THE BUG. Both it and validate.py's comment said to delete each other when
the divergence was closed. It is closed, so both are deleted.

THE DIVERGENCE WAS WIDER THAN ONE KEY. `maintenance_discharge_w` had the
identical three-way split (config.yaml 2000, MaintConfig 2500) and the card
named only the charge side. Closing one and leaving its twin would have
satisfied the numbers and left three sources of truth one line down, which is
the state that produced the bug. Both are closed, and so is the whole family:
all eight `maintenance_*` keys go through the same mechanism.

WHAT THE SINGLE SOURCE IS. config.yaml's `options:` block - it is what the
Supervisor reads and what the operator edits, so it wins by definition. There
is now exactly one in-code copy, `maintenance.MAINT_OPTION_DEFAULTS`, which is
TARIFF-02's `PRICE_OPTION_DEFAULTS` and SAFETY-24's `PEAK_OPTION_DEFAULTS`
pattern applied to the family that named the card - validate.py's rule 8 comment
already called that "CFG-03 read as a rule rather than as a complaint", so this
makes the rule hold where it was first broken rather than inventing a fourth
mechanism for one option family.

A MIRROR RATHER THAN A RUNTIME READ, and the reason is mechanical: the
Dockerfile copies `app/` and `run.sh` into the image and NOT config.yaml. The
running add-on cannot open the file it is configured by, so there is nothing to
read at 03:00 on a client's Pi, and a YAML-subset parser that could fail at
import is a new way for the add-on not to start. What makes the copy safe is
that test_maintenance.py pins every entry by READING the shipped file - drift is
a CI failure, not a comment.

EVERY OTHER SITE NOW DERIVES FROM IT OR HAS CEASED TO EXIST:

  * MaintConfig's eight dataclass defaults are indexed out of the mirror. No
    numeric literal survives in the class that held the third opinion.
  * `MaintConfig.from_options()` is the ONLY place in the add-on that reads a
    `maintenance_*` option. main.py's eight inline `opts.get(key, <literal>)`
    calls are gone: moving the read next to the mirror means the fallback cannot
    be anything but the mirror, because there is no literal in sight of it to
    disagree with. It uses `key in opts` rather than truthiness, so a shipped
    `false` or `0` is honoured instead of being quietly replaced by the default
    - this card's own bug in a different costume.
  * main.py's SECOND fallback site - the cheap-window charge floor at the
    P_MAINT_SHAPE claim - reads `self.maint.cfg.charge_w` instead of re-opening
    the options dict with its own literal. The Controller had already parsed
    this once in __init__; asking the object that owns it cannot drift from it,
    and the rate the shaping asks for can no longer be a different number from
    the rate the state machine drains at on the same install.
  * validate.py's rule 6 and its `maintenance_discharge_w` warning take their
    fallbacks from the mirror.

WHERE THE RANGE LIVES, STATED AND CHECKED. config.yaml's `schema:` block carries
`maintenance_charge_w: int(500,5000)` - a fourth declaration site of a different
kind. It is a BOUND, not a default, so it is not this bug; but leaving the
question open is how a fifth site arrives. The decision recorded in config.yaml
and in maintenance.py is: bounds live in the schema block ONLY, because the
Supervisor is what enforces them and the Supervisor reads only that file, so a
Python copy of `int(500,5000)` would be a place to disagree and nothing else.
test_maintenance.py checks both halves of that: every mirrored key must have a
schema entry - without one the Supervisor drops the option and the add-on
silently runs on the mirror instead of the operator's value - and every shipped
default must lie INSIDE its own range, since a default the schema rejects is a
config that cannot be re-entered once it is edited. What the schema grammar
cannot express is a relation BETWEEN keys (`maintenance_charge_w` against
`max_w`), which is exactly why rule 6 is written in Python and why it does not
belong in the mirror either.

THE REPLACEMENT CHECKS, AND HOW THEY WERE VERIFIED. test_validate.py's new
section exercises the same four consumers the defect ran through, the same way:
the validator ACCEPTS a dict with every maintenance key missing; a REAL
Controller built from that same dict holds 2000 W (through main.py, not through
a regex over its source); `MaintConfig()` answers 2000 W with no dict at all;
and the real arbiter emits `-2000 W, limited by supervised(max_w)` instead of
`0 W, contradiction=True`. test_maintenance.py pins the mirror to config.yaml in
both directions - equal values, and full coverage of every `maintenance_*` key
the file ships, so a ninth key cannot arrive unmirrored - and asserts the
consumers move as a RELATION rather than against numbers, reading MaintConfig's
defaults back out of `dataclasses.fields()`.

Each new check was verified by BREAKING the thing it watches and observing red,
this project's rule:

  1. config.yaml -> 1500, mirror left at 2000:  test_maintenance 1 FAILED,
     test_validate 4 FAILED.
  2. config.yaml AND the mirror -> 1500: green again, and every consumer moved
     together - MaintConfig() 1500 W, the Controller 1500 W, and the arbiter
     `-1500 W, limited by maintenance(cheap-window charge)` where it had said
     `-2000 W, limited by supervised(max_w)`. That is AC4: change the single
     source and watch the consumers follow.
  3. `charge_w: float = 2500.0` retyped into the dataclass: 2 FAILED in each of
     the two files.
  4. `opts.get("maintenance_charge_w", 2500)` restored in main.py: 1 FAILED,
     naming the file and the literal it found.
  5. `maintenance_hold_min` deleted from config.yaml's options block: 3 FAILED.

Full suite 17/17 in goodwe-addon-ci, twice, once under parallel load.

Stale prose that asserted the now-closed divergence as current is corrected in
app/watchdog.py, test_watchdog.py and test_peakguard.py - watchdog.py's example
still uses 1500 W, but because the point of the example is a charge strictly
inside the ceiling, not because 2500 is what ships.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-01 06:16:54 +02:00
glenn schrooyenandClaude Opus 5 7b4877d56d TEST-15: purge the bytecode cache before a mutation run, not after
checks / unit (pull_request) Successful in 3m35s
FCST-03's developer reverted `self.provisional` to `here.provisional`, re-ran,
and reported the mutation as a survivor. It was not one. CPython validates a
cached `.pyc` on (source size, source mtime truncated to whole seconds), and
that edit moved neither number - same length, same second - so the interpreter
loaded the bytecode it already had. Disassembly settled it at the time: the
source read `here`, the running code loaded `self`. A mutation run had graded
code that was not there, with no error and exit status 0.

This does not make the results already on the record wrong. It makes them
UNVERIFIED, and that distinction is the whole card - so nothing here re-runs a
campaign and nothing here quietly assumes the old numbers hold.

REPRODUCED, THEN CLOSED. test_bytecode.py builds a real package whose two
return values are the same length, imports it in a real subprocess, rewrites it
inside the same second (retrying until both writes land in one whole second -
milliseconds, no sleep) and reads back which value ran. Part 1 shows the
interpreter running SELF off a file that says HERE.

AND THE TWO OBVIOUS MITIGATIONS DO NOT WORK. Measured, not read off
documentation: `python3 -B` and PYTHONDONTWRITEBYTECODE=1 are write-side only.
Neither stops an EXISTING stale .pyc being read, and a mutation run always has
one, because the previous run wrote it. Part 2 grades both still running the old
code. The advice in test_control.py's coverage audit led with `-B`; it is
corrected here - the purge is the half that works, and `-B` earns its place by
keeping THIS run from leaving a cache for the NEXT edit to inherit.

NO SLEEP ANYWHERE. One-second mtime resolution is the mechanism, not the enemy.
Waiting it out would slow every run down and would still only cover the edit
somebody remembered to slow down.

THE HARNESS. tools/mutation_run.sh purges, prints a sha256/byte fingerprint of
every app/*.py it is about to grade - so a mutation report can say WHICH source
produced it, which is the reviewer's addition to this card - runs each suite
under `python3 -B`, refuses a tree with no test_*.py (CI-01's rule, for CI-01's
reason), and fails if a cache appears during the run. It takes the tree as an
argument so the infra repo's replay harnesses can call it without being moved.

WHERE IT IS SAID (AC 2). MUTATION.md carries the mechanism, the measurement,
the reporting rules and the survey, and every one of the 16 suites now points at
it from its docstring. That list is DERIVED FROM THE TREE by test_bytecode.py
part 5, so a new suite that joins this directory without the pointer is red -
the same failure shape CI-01's file glob exists to prevent.

CI WAS ALREADY IMMUNE, AND IS DESCRIBED THAT WAY (AC 4). Verified rather than
reasoned: with the checkout bind mounted `-v "$WS:/w:ro"` the interpreter writes
no __pycache__ into the tree at all, and it fails SILENTLY - no error, exit
status 0 - while the same probe on a writable mount produces one. Each job also
rm -rf's its workspace and clones afresh, so nothing crosses between jobs on the
shared runner. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces only: the
`:ro` is one character wide and the next person debugging a write will be
tempted by it. Part 6 grades both ON THE DOCKER COMMAND LINE rather than on the
file - the first draft searched the whole workflow and stayed green after the
flag was deleted, because the comment explaining it still named it.

THE SHIPPED ADD-ON IS NOT AFFECTED and the question is closed:
goodwe_controller/Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was
written. There is no deploy-side finding.

THE SURVEY (AC 3), in MUTATION.md, scoped BY THE PROPERTY. The defect is
one-directional - a mutation that never took leaves the suite green, so stale
bytecode manufactures SURVIVORS and cannot manufacture a red - which puts every
"all red, no survivors" claim in the window out of scope, along with mutations
executed in-process (SAFETY-07's B1/B2/B3, test_peakguard parts 7 and 10, where
no source file is edited) and everything run after the purge discipline landed
on 2026-08-31 (SAFETY-24, SAFETY-26, OPT-04, FCST-03's re-run). What is left is
the recorded SURVIVORS from source-edit runs before that date. Two were re-run
here under the harness and both still stand: TARIFF-01's record_block() ignoring
its policy argument, and SAFETY-03's abs() on the clamp limit - 15 suites green
each, on the tree as it stood. The rest are labelled still-unverified rather
than assumed or re-run; each is one harness run to close, and the moment to
spend it is when somebody next touches that module.

OUT OF SCOPE AND RECORDED: the infra repo's sim/ replay harnesses import the
add-on and write bytecode into both trees (goodwe/sim/__pycache__ exists today),
so SAFETY-02's headline replay carries the same exposure. mutation_run.sh takes
a tree argument for exactly that, but the change belongs in that repo and some
of those harnesses want the rig.

RED AND GREEN. Every new check was broken and watched fail: the purge commented
out of the harness turns part 4 red (and its non-vacuity probe already proves
the fixture would mis-grade without it); one docstring pointer removed turns
part 5 red naming the file; `:ro` and the `-e` flag removed from the workflow
turn part 6 red. Full suite green, 16 files, in the CI image on a read-only
mount - the shape the runner uses.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-01 02:07:09 +02:00
adminandClaude Opus 5 0a1e61dbc9 Packaged as a Home Assistant add-on, with a field guide
Turns the reference RS485 controller into something a technician can install
at a client site: a typed config form instead of YAML, an ingress UI that
names misconfiguration in words, and persistent state that cannot be broken by
a timezone.

Why an add-on rather than YAML packages or blueprints:

- Blueprints cannot create helpers, and the maintenance cycle is a state
  machine whose phase and completion date must survive restarts.
- YAML packages need filesystem access, a configuration.yaml edit and a
  restart - none of which belong in a client install.
- Add-ons authenticate with SUPERVISOR_TOKEN, so there is no long-lived token
  to generate, store or leak on someone else's machine.
- Requires HA OS/Supervised. Container and Core installs cannot run add-ons at
  all, which is a market decision, not an oversight.

The control law and the maintenance machine are pure functions with no Home
Assistant imports, and both ship with runnable checks (22 and 22 assertions).
Every assertion corresponds to a rule whose absence caused an observed failure
on hardware - the saturation duration term, the clamp-before-slew ordering, the
deadband, the sign convention.

One behaviour deliberately differs from the implementation it replaces: when
its inputs go missing this commands 0 W rather than replaying the last
setpoint. The reference version kept replaying, which the hardware watchdog
cannot catch - from the ESP32's side, Home Assistant is still talking to it.

Includes the ESPHome firmware (now parameterised: node name, inverter rating,
watchdog timeout) and the optional RS485 e-stop. FIELD-GUIDE.md carries the
commissioning gates, all judged on the wire rather than on how Home Assistant
looks, plus the written statement a site without an e-stop needs signed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:15:25 +02:00