infra-pin / fresh (pull_request) Failing after 2s
B's power reading shows -95 to -118 W at idle (standby draw), so the
|reading| < 100 W refusal band never held a refusing B: never at N=2,
and since SAFETY-94's shared rule not at N=1 either (review F1).

Each unit now learns its idle reading (app/idle.py): only while control
runs, the unit is not refused/stale/tripped and its command has stayed
within 50 W for 120 s; first value a 120 s mean, then a 30 min follow;
samples beyond 250 W dropped, value clamped to 250 W; saved per unit and
restored. The shared refusal evidence, compute()'s N=1 engage and end,
the unit refusal ends, the stale-path refusal and SAFETY-42's "parked"
test are centred on it. Until learned it is 0 W, the rule as it was.

Refusing B caught at N=1 28/28/65 s and N=2 24/24/60 s (1/2/5 s
meters), before never; refusing A unchanged. Healthy B with its offset,
SAFETY-94's scenarios, 96 runs: 0 stale, 0 refused. Live replay: 0.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-04 12:21:24 +02:00
glenn schrooyenandClaude Opus 5.5 dd5eb6fdc8 SAFETY-94 review: tests for three surviving mutants; record two gaps
checks / unit (pull_request) Successful in 28m7s
infra-pin / fresh (pull_request) Failing after 2s
- test_safety94 part 4: time under 250 W is not counted; a command that
  swaps direction every cycle is never refusal evidence; a reading moving
  away from the ask does not restart the evidence. These kill review
  mutants R1, R3 and R6, which survived the PR's tests.
- DECISIONS: at N=1 a battery with B's standby offset no longer latches
  a refusal (SAFETY-97 now covers N=1); a part-time ask is caught after
  35/d s of wall time.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-04 01:17:52 +02:00
adminandClaude Opus 5.5 6759d21ea5 SAFETY-94: a healthy battery that lags or reverses is not flagged as frozen or refusing
checks / unit (pull_request) Successful in 28m10s
infra-pin / fresh (pull_request) Failing after 2s
The stale-reading gate counted its 35 s from the register's last change, so
after a rest the first read after a new command tripped it (SAFETY-58; live
2026-10-03, four trips 1 s after the command). It now counts only the time
the command asked the register to move.

At N=1 the refusal engaged after 12 frozen cycles if the reading was under
100 W at that moment, which a battery reversing through its lag passes at a
1 s meter. The refusal now needs the N>1 evidence at every roster size: under
100 W, one way, for 12 cycles spanning 22 s, restarting when the reading
moves 50 W towards the ask.

DECISIONS/SAFETY-94-lagging-battery.md; test_safety94.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-04 00:15:42 +02:00
admin 3a54b253cb Merge pull request 'Deploy 0.14.0 to master' (#170) from deploy-0.14.0 into master
Deploy 0.14.0 to master (#170)
v0.14.0
2026-10-03 12:32:16 +02:00
admin 02ed1200dc Merge pull request 'Release 0.14.0' (#169) from release-0.14.0 into release/1.0
infra-pin / fresh (push) Successful in 1s
checks / unit (pull_request) Successful in 27m3s
infra-pin / fresh (pull_request) Successful in 2s
2026-10-03 11:29:13 +02:00
Claude f13dab1407 Release 0.14.0: changelog review fixes
checks / unit (pull_request) Successful in 26m57s
infra-pin / fresh (pull_request) Successful in 1s
Slew step not one house's 400 W; three two-inverter known issues, not
four; commissioning reference covers a new install; SoC example holds
for decimal sensors; SAFETY-95 states the jump, not the export.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 11:01:44 +02:00
glenn schrooyenandClaude Opus 5.5 b307db1049 Release 0.14.0: version bump and changelog
checks / unit (pull_request) Successful in 27m2s
infra-pin / fresh (pull_request) Successful in 2s
Two inverters are now supported for maintenance and the peak guard
(SAFETY-91, SAFETY-93). No option changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 10:30:25 +02:00
admin e51e3e02b2 Merge pull request 'CI-13: infra-pin to admin/goodwe 0c04488 (FW-05, WITNESS-08)' (#168) from ci-13-infra-pin-0c04488 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-10-03 10:27:02 +02:00
glenn schrooyenandClaude Opus 5.5 69dc1f0e7b CI: bump infra pin to 0c04488 (admin/goodwe#62 FW-05, #63 WITNESS-08)
checks / unit (pull_request) Successful in 27m26s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 09:56:36 +02:00
admin 858f77cfb5 Merge pull request 'SAFETY-93: the maintenance charge end hands back smoothly, with no grid charging at a high house' (#167) from safety-93-no-grid-charge-at-charge-end into release/1.0
infra-pin / fresh (push) Failing after 2s
2026-10-03 00:58:37 +02:00
adminandClaude Opus 5.5 214051d1a8 SAFETY-93 review: a charge that ends by a stale link or a refusal hands back smoothly too
checks / unit (pull_request) Successful in 27m5s
infra-pin / fresh (pull_request) Failing after 1s
A battery still in CHARGE but dropped by the allocator (stale link, or a
SAFETY-73 refusal contradicting its charge) left its -2000 W in the loop's
start point, and B went 0 -> -1600 W in one cycle. The end is now noted
after the unit claims are filed: in CHARGE, live and not contradicted.
Tests: part 6 (stale link, refusal) and a spy on the guard suspension.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 00:10:21 +02:00
adminandClaude Opus 5.5 05eb93f139 SAFETY-93: the maintenance charge end hands back smoothly, with no grid charging at a high house
checks / unit (pull_request) Successful in 26m55s
infra-pin / fresh (pull_request) Failing after 1s
At N>=2, when a battery's maintenance charge ended, its watts stayed in the
loop's start point and landed on the other battery (B 0 -> -1600 W in one
cycle, charging from the grid at a 6000 W house). On the cycle a charge
ends, the loop now starts from what the others stood at plus that
battery's new command. N=1 and all identity digests unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 22:38:42 +02:00
admin f3e409cf76 Merge pull request 'SAFETY-91: a held battery is drawn only after the others are full' (#165) from safety-91-held-battery-last into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-10-02 15:53:33 +02:00
admin 8b9680fc35 Merge pull request 'Deploy 0.13.0 to master' (#166) from deploy-0.13.0 into master
Reviewed-on: #166
v0.13.0
2026-10-02 15:26:46 +02:00
adminandClaude Opus 5.5 4cd604afcb SAFETY-91 review: a held-back battery is released 1 point above its reserve
checks / unit (pull_request) Successful in 26m26s
infra-pin / fresh (pull_request) Successful in 1s
A SoC reading flipping across the reserve swapped ~1000 W between the
batteries on each flip (grid +-500 W with unequal lags). Also grades
next_quarter()'s staleness boundary (29.5 / 30.5 s).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 14:54:20 +02:00
adminandClaude Opus 5.5 6872353e2e SAFETY-91: a held battery is drawn only after the others are full
checks / unit (pull_request) Successful in 26m19s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 a battery at or under its own peak reserve now weighs 0 whenever
the site gives (not only for the peak), a draining battery's pin becomes
a floor at its drain rate so it rises before the held one gives, and a
quarter's edge is graded on the next quarter when its first telegram is
late. SAFETY-25 option A stays: the held battery is still drawn once the
others are full. N=1 unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 14:03:54 +02:00
admin 8c438ab2e6 Release 0.13.0 (#164)
infra-pin / fresh (push) Successful in 2s
checks / unit (pull_request) Successful in 25m53s
infra-pin / fresh (pull_request) Successful in 1s
2026-10-02 10:04:13 +02:00
adminandClaude Opus 5.5 b37b7f95dc REL-0.13.0 review: plainer, truer 0.13.0 changelog
checks / unit (pull_request) Successful in 25m52s
infra-pin / fresh (pull_request) Successful in 1s
Crash, not stop, for SAFETY-61; Watchdog off by default; its own
warning for the 50 W peak margin (also under a higher month peak);
"refuses power" for SAFETY-52/73; no one-house options claim.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 09:37:34 +02:00
adminandClaude Opus 5.5 28cab03947 REL-0.13.0: cut 0.13.0
checks / unit (pull_request) Successful in 25m55s
infra-pin / fresh (pull_request) Successful in 2s
Bump config.yaml version 0.12.0 -> 0.13.0 and close a ## 0.13.0
CHANGELOG section covering every merge since 0.12.0 (a45ed06), with the
known issues SAFETY-90/91/92/93/94. Option surface 77 -> 83, none removed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 09:04:47 +02:00
admin 61072ca460 Merge pull request 'SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery' (#163) from safety-85-no-false-not-keeping-up into release/1.0
infra-pin / fresh (push) Successful in 1s
SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery (#163)
2026-10-01 20:52:17 +02:00
adminandClaude Opus 5.5 7b723a6cd5 SAFETY-85 review: grade discharge only, over the plant's settle time
checks / unit (pull_request) Successful in 25m47s
infra-pin / fresh (pull_request) Successful in 2s
Rule 2 graded each battery against last cycle's command and graded charges
too. On plantsim's battery (10 s lag) at the 2 s meter it warned at every
drain or charge start and 15 times an hour under the peak guard at N=2; a
charge tapering near full warned 11 times in 50 min (SAFETY-42 section 7).
Now a discharge is graded against the least it stood at over SHORT_CYCLES /
SHORT_SPAN_S. DOCS lists `mode-bound` under Loop reason. test_safety85 part 7:
peak guard with a dead battery, lagging plant, taper; part 3: the bound ends
with maintenance.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 20:25:41 +02:00
glenn schrooyenandClaude Opus 5.5 4b81387908 SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery
checks / unit (pull_request) Successful in 25m35s
infra-pin / fresh (pull_request) Successful in 2s
The loop's integrator bound counts only on a cycle the loop decided. A battery
another owner set (maintenance, the peak guard, a safety limit) alarms only
when it gives more than saturation_w less than told for saturation_cycles
cycles. At N>=2 the loop is bounded while maintenance holds a battery, so it
does not wind and control comes back one slew step a cycle. The status row
counts episodes, not cycles. Digests re-pinned where behaviour changed on
purpose; DECISIONS/SAFETY-85-no-false-not-keeping-up.md has the list.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 19:05:27 +02:00
admin 935878193b Merge pull request 'SAFETY-87: peak guard uses every battery that can still give' (#162) from safety-87-guard-uses-able-batteries into release/1.0
infra-pin / fresh (push) Successful in 2s
SAFETY-87: peak guard uses every battery that can still give (#162)
2026-10-01 12:06:41 +02:00
Claude b4d25dd485 SAFETY-87 review: DOCS, the drain rate may rise for the peak at N>=2
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 24m53s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 11:08:42 +02:00
Claude a4a04d203c SAFETY-87 review: grade the three surviving review mutants
checks / unit (pull_request) Successful in 25m5s
infra-pin / fresh (pull_request) Successful in 1s
A battery refusing only to charge stays able; the reserve alarm is graded
on the real limit, not the aim; 'control still runs' is set on the two
peak rows only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 11:07:43 +02:00
Claude aa501ffec7 SAFETY-87 review: maintenance pins beside a held battery
checks / unit (pull_request) Successful in 26m5s
infra-pin / fresh (pull_request) Successful in 1s
A draining battery that may still give is raised from its drain rate
towards its rating for the peak floor while another battery is held
(peak > drain); before, the floor's rest landed on the held battery. In a
HOLD, a held battery's own pin counts among the others: a held drain no
longer over-places the site, and a held charge probe no longer parks it.

Tests: test_safety87.py part 10 (drain beside a held battery, N=3 HOLD,
unknown cut-out and unread level at N=3, a stopping row outranks the
running peak alarm). DECISIONS entry updated, incl. the modes-on exception.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 10:50:01 +02:00
Claude d89c093318 SAFETY-87: grade the surviving mutants (dropped battery, own-floor naming, pair permission, latched row)
checks / unit (pull_request) Successful in 24m56s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 09:55:29 +02:00
Claude d0db5b8c39 SAFETY-87: peak guard uses every battery that can still give
checks / unit (pull_request) Successful in 25m45s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 a battery at or under its own peak reserve is held: it gives
nothing for the peak (weight 0 while the site gives) and the guard's need
is placed on the live, non-refusing batteries above theirs. The guard is
floor-limited, and alarms, only when those cannot hold the limit at full
power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold
the Home page at 0 W, because control keeps running. N=1 is byte-identical.

DECISIONS/SAFETY-87-guard-uses-able-batteries.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 09:29:30 +02:00
admin b8ddfd787f Merge pull request 'SAFETY-86: peak guard outranks the maintenance hold' (#161) from safety-86-peak-over-hold into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-10-01 02:27:36 +02:00
glenn schrooyenandClaude Opus 5.5 1c41a1e412 SAFETY-86 review: hold the site at the peak floor while a HOLD gives
checks / unit (pull_request) Successful in 24m23s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 the holding pack's pin follows the guard's floor while the loop
still asks for +5000 W, so the ALLOCATOR "could not be placed" row was
re-logged on every 1 W change and filled the 40-row action log. While the
pin is raised, cycle() now files a site `hold` ceiling at the floor
(P_MAINTENANCE), as SAFETY-84 does for a charge. Filed only when the
holding pack gives; hi == the floor, so it never clashes with it.

Tests: a noisy N=2 house logs no ALLOCATOR row and at most one clamp
row (20 and 20 without the ceiling); the ceiling is the floor itself;
a CHARGE is not refiled at N=1. The DECISIONS entry records the owner's
2026-10-01 decision: the HOLD ends on its clock, no top-up.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 02:00:20 +02:00
glenn schrooyenandClaude Opus 5.5 ba31e7c8b1 SAFETY-86: peak guard outranks the maintenance hold
checks / unit (pull_request) Successful in 24m17s
infra-pin / fresh (pull_request) Successful in 1s
During a HOLD the holding battery gives what keeps the quarter at the peak
aim. N=1: the peak floor is refiled at P_MAINTENANCE, as for a drain
(SAFETY-83). N>=2: the hold's pin is raised to the floor minus what the
other live batteries may place, so they give first. A site stop still
decides alone. The hold ends on its clock even if the level dipped.
Below the aim nothing changes (rows identical).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:56:34 +02:00
glenn schrooyenandClaude Opus 5.5 513183aba3 test_peak_margin: read the month peak on the runs' clock, not today's
Part 3 read the simulated September's peak with the wall clock, so from
2026-10-01 it read no peak and crashed on every tree (4ad8298 too).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:56:34 +02:00
admin 4ad8298ead Merge pull request 'SAFETY-84: maintenance charge at N=2 no longer stalls' (#160) from safety-84-n2-maint-charge into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-30 21:00:56 +02:00
adminandClaude Opus 5.5 5c9f64d87a SAFETY-84 review: check the charging pack gives under the guard, and no-P1 at N=2
checks / unit (pull_request) Successful in 23m51s
infra-pin / fresh (pull_request) Successful in 1s
A 6500 W house needs more than B alone: A must give (the N>=2 suspension),
with a non-vacuous run without it (banks over the cap, 'Load too high').
Without P1 the charge is not sized, as at N=1: A charges at 2000 W.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 20:36:46 +02:00
glenn schrooyenandClaude Opus 5.5 43a52e7f60 SAFETY-84: maintenance charge at N=2 no longer stalls
checks / unit (pull_request) Successful in 23m57s
infra-pin / fresh (pull_request) Successful in 2s
At N>=2 a cheap-window maintenance charge files a site `hi` (`charge`,
P_MAINT_SHAPE) equal to what the charging pack's own `hi` places, so the
other pack never has to give against it. The charge is sized to the
quarter's headroom under the peak aim so it yields to the peak guard, and
to 0 W under a site safety stop. N=1 byte-identical (safety84_identity).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 19:47:15 +02:00
admin 9d5b7d129a Merge pull request 'SAFETY-83: peak guard outranks the maintenance drain at N=1' (#158) from safety-83-peak-over-drain into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-30 14:58:41 +02:00
glenn schrooyenandClaude Opus 5.5 bc6d744c6c SAFETY-83 review: banked month peak and no false alarm during a drain
checks / unit (pull_request) Successful in 23m23s
infra-pin / fresh (pull_request) Successful in 1s
test_safety83 part 1: under a month peak banked above the limit the drain
is lifted to peak - margin, and a drain the guard raises (steady or with
5 s spikes that saturate it) gives no 'Load too high' alarm; the part 3
overload still does.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 13:41:47 +02:00
glenn schrooyenandClaude Opus 5.5 79b94024cb Merge release/1.0 (OPT-11 P4, #156) into safety-83-peak-over-drain
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 13:35:28 +02:00
goodwe-agent 2f5ab1f378 MAINT-10: DECISIONS says where the release note lives
checks / unit (pull_request) Successful in 23m8s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 23:09:06 +02:00
goodwe-agent fbdd552555 MAINT-10: CHANGELOG draft line moves to the PR (version gate refuses an Unreleased block)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 23:08:46 +02:00
admin 1145a931ac Merge pull request 'OPT-11 P4: solar forecast and day plan' (#156) from opt11-p4-solar-forecast into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-29 23:01:48 +02:00
adminandClaude Opus 5.5 56cafefa79 SAFETY-83: a refiled peak floor stays under a safety SET, graded directly
checks / unit (pull_request) Successful in 23m32s
infra-pin / fresh (pull_request) Successful in 1s
Kills M5 (refiled at P_SAFETY) on its own sentence, not only through the
per-cycle claim check.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:52:52 +02:00
goodwe-agent 02c0a3dd7b MAINT-10: maintenance start hour in local time, default 19:00
The start hour was compared with the UTC hour, so the shipped 10 started at
12:00 in a Belgian summer. It is now read in Home Assistant's time zone
(fallback: the container's TZ, then UTC, one log line says which), and the
default moves to 19. DST: a missing hour starts at the first hour after the
jump; a repeated hour starts only in its first pass. Stored options are not
rewritten: a saved 10 now means 10:00 local (DOCS, CHANGELOG).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:52:05 +02:00
adminandClaude Opus 5.5 3f69c174af SAFETY-83: grade the refile at its boundary, and N=2 on its own
checks / unit (pull_request) Successful in 23m37s
infra-pin / fresh (pull_request) Successful in 1s
A floor exactly at the drain rate stays at P_PEAK (kills `lo >= rate`), and
part 4's N=2 check no longer shares its failure list with N=1.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:50:46 +02:00
adminandClaude Opus 5.5 d77f1b1fdf SAFETY-83: peak guard outranks the maintenance drain at N=1
checks / unit (pull_request) Successful in 16m54s
infra-pin / fresh (pull_request) Successful in 1s
At N=1 the drain is the site SET at P_MAINTENANCE (60), so the peak floor
(P_PEAK, 50) was not applied and the house imported what the drain left.
Where the floor asks for more than the drain rate, main.py now refiles the
peak claim at P_MAINTENANCE, so it wins; safety SETs still park everything.
Nothing else changes: safety78_identity --diff against 35cdffe changes only
cycles where the guard wanted more than the drain; N=2 is byte-identical.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:40:14 +02:00
glenn schrooyenandClaude Opus 5.5 b171ada894 Merge release/1.0 (SAFETY-78, #154) into opt11-p4-solar-forecast
checks / unit (pull_request) Successful in 23m54s
infra-pin / fresh (pull_request) Successful in 1s
Conflicts: modetrade.decide() takes both the day plan (targets) and
SAFETY-78's draining flag; the Why line keeps SAFETY-78's other_cycle
ahead of the plan's word (test added).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:37:09 +02:00
Claude review c38dd1e969 OPT-15 review: bound unmeasured charge stops, test the hold's rules and M15
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Successful in 1s
- A second unmeasured-headroom stop in a quarter latches the charge: a
  headroom missing every other cycle flipped it 1799 times in 30 min.
- Unit test of the run-edge hold's end conditions and of a small step.
- Outside its probe a refuser does not make the others rest (M15 red).
- DECISIONS: one review line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:31:52 +02:00
glenn schrooyenandClaude Opus 5.5 0b96e3191c OPT-11 P4 review: records and text
checks / unit (pull_request) Failing after 4s
infra-pin / fresh (pull_request) Successful in 1s
- DECISIONS: the Cheap hours change and why; the no-sun replay (the gain is
  Leftover solar buying the evening's shortfall; the forecast added 0.14
  EUR); the reconstruction bias stated plainly.
- DOCS: Cheap hours ignores the forecast; a reading from before midnight
  is stale.
- The forecast line: "Solar still to come today: ..." (it is what is
  left, and it stays within the 12-word limit).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:29:00 +02:00
admin 35cdffe766 Merge pull request 'SAFETY-78: maintenance drain at N=2 no longer stalls' (#154) from safety-78-drain-at-two into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-29 22:20:29 +02:00
glenn schrooyenandClaude Opus 5.5 a692560960 Merge release/1.0 (SAFETY-81, #155) into opt11-p4-solar-forecast
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:08:52 +02:00