SAFETY-52-refused-hold
8
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
43c144b8d9 |
SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.
REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:
10:51:24.7 0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
10:51:29.7 the command reaches +1060 W - 800 W of travel
10:52:00 the conjunction arms. Inverter.batt becomes None
10:52:21.7 the site commands 0 W, on the wire
... 0x0518 does not change value for 850.0 s. The setpoint does not
change value for 790.0 s. The house exports 2.4 kW throughout
~11:04 a human restarts the add-on. That is what ends it
AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.
THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.
THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:
the verdict is withdrawn when the obligation that produced it has been gone
for RELEASE_S, and the register is then re-graded from scratch.
RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.
The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.
WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.
Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.
main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.
Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.
Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
03ef61fa3b |
SAFETY-48: the slew step ceiling reaches the integrator, and what it bounds is the LEAD
`compute()` freezes the integrator with an asymmetric rule and the comment beside it states the requirement outright - "the requirement is that the INTEGRATOR stop accumulating, not only the command" - but `frozen` is computed from ONE signal, `abs(prev_w - actual_w) > saturation_w`, and slew-limiting never enters it. The integrator moves `gain * error` a cycle and the command moves at most `slew_w`, so the integrator outruns the command whenever `|error| > slew_w / gain`: 667 W at the live shape, against a measured median grid error of 1114 W at the onset of a recorded episode. SAFETY-39's retune made it MORE frequent, not less - a smaller step is a lower threshold. ⚠️ THE FORM THE CARD ASKED FOR RAISES THE BILLED QUANTITY, WHICH IS WHY IT IS NOT WHAT SHIPPED. Reusing the asymmetric freeze on a carried slew flag was built from release/1.0's own source and measured over 16.00 days / 256 252 meter instants of the live install's recorder: export 39.61 -> 34.43 kWh, and the worst quarter-hour average OFFTAKE 3739 -> 3935 W with the mean quarter +2.73 W, in five of six plant and tuning variants. A frozen integrator stops at `prev + gain*error`, which undershoots by (1 - gain); for an export that is free and for an import it is offtake, for as long as the ramp lasts. The card said "do not invent a second rule"; the measurement says to, and both sentences are recorded. WHAT SHIPS BOUNDS THE LEAD AT ONE SLEW STEP, inside the branch where the slew actually bound. Same 16 days, same ticks, same disturbance, same plant, same seed: export 39.61 -> 34.07 kWh, wasted throughput 4.67 -> 3.19 kWh, battery sign reversals 2992 -> 2770, median recovery 232 -> 199 s, p99 849 -> 850 s, max 901 -> 898 s, unrecovered 53 -> 31, worst |i_w - prev_w| 9200 -> 800 W - and the worst 15-minute average offtake 3739 -> 3434 W, i.e. the billed quantity IMPROVES. `i_w = slewed` (a cap of zero) is better again at 32.02 kWh and is refused: it is the velocity form this module's docstring says `i_w=None` collapses to. TWO COMMITTED NUMBERS MOVED, DELIBERATELY, WITH THE REASON BESIDE THEM. SAFETY-13's released command settles at -800 W and -1200 W where release/1.0 settled at -1190 W and -2390 W, because there is less wound integrator to settle onto; AC 4's property - it stops at the frozen integrator, not the rail - is what is asserted and the second is now graded against `i_w` rather than a literal. And SAFETY-39's "the slew does not own the over-absorption" is now FALSE - INVERTED, on the independent first-order plant test_control.py writes itself: 1005/1109/1285/1330 W rising with a slower slew becomes 729/550/424/326 falling. Two plant models that share nothing agree on the sign. Evidence: `tools/replay_recorded_loop.py` plus the read-only capture it made (scenarios/loop-2026-09-02_2026-09-17). The "before" law is the shipped file with the block removed by a named substitution - never a transcription - and a missing anchor is a REFUSAL carrying "NOTHING HAS BEEN MEASURED". The instrument prints its own fidelity first: it reproduces 39.6 kWh of export where the install exported 29.4, i.e. it is ~35 % pessimistic about the loop's tracking, so only the delta is claimed. 30/30 suites green, including test_control.py's exhaustive i_w=None equivalence sweep against the transcribed release/1.0 law, untouched: the cap moves `i_w` and not `target`, and that sweep compares (target_w, sat_count, frozen, reason). Six law mutations, one instrument battery. L4 - the cap applied unconditionally, -92 B - was a SURVIVOR of all thirty files: it is bit-identical on the shipped configuration (0 of 256 246 ticks) and separable on 2050 of 257 400 swept states, all at `integrator_max_w` above `max_w`, which part 4 now drives. L5 and L6 are ZERO BYTES. AND TWO COMMENTS IN THIS CARD WERE INVENTED AND ARE CORRECTED IN PLACE. The one-sided spelling was justified by a two-sided form that would "drag a trailing integrator" - it does not, and the two agree on 205 920 of 205 920 swept states; and a "118 of 256 252 ticks" figure had been measured against a different pair. MUTATION.md gains habits 21 and 22 for both shapes. NOT DEPLOYED, NOT VERSIONED. The live install still runs release/1.0's law. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
17b7b447c4 |
TARIFF-09: ask the day-ahead feed for the horizon it was handed
checks / unit (pull_request) Successful in 7m10s
`generic_dayahead.fetch()` accepted `since` and `until` and requested the
bare `?bzn=BE`, which answers ONE Brussels day. Everything past today was
then filled from yesterday's profile by FCST-04, flagged provisional, and
§8.3 drops provisional hours from the trade set -- so the optimiser never
saw tomorrow as firm, at any hour of any day, and nothing reported it.
Measured on
|
||
|
|
6eba18968c |
TARIFF-08: the day-ahead feed is read in the shape it actually publishes
checks / unit (pull_request) Failing after 3s
`generic_dayahead` could not read one byte of `api.energy-charts.info`, and
never had been able to. `_points_from_json()` asks for `doc["data"]`, a list of
`{start, price_eur_mwh}` objects; that document does not exist. Fetched live on
2026-09-10 the feed returns COLUMNAR parallel arrays and no `data` key at all -
`unix_seconds` (96 UTC epoch seconds, 900 s apart), `price` (96 floats),
`unit: 'EUR / MWh'`. Driving the shipped parser against that body:
`SourceUnavailable: the feed carried no 'data' list`. It is the only shipped
provider whose endpoint anybody has reached, so dynamic pricing did not work.
AND §11.4 MADE IT SILENT, which is why it survived to release: a parse error
becomes no_data, becomes the static profile, becomes arbitrage off - the
CORRECT degradation, saying nothing about the cause. A site would have sat on
the fallback indefinitely.
AND THE SUITE COULD NOT SEE IT, because every fixture was built from the
parser's own assumption. test_price.py, test_price_history.py and
test_static_tariff.py each built `json.dumps({"data": [...]})`, a shape invented
here and published by nobody, so the checks graded the parser against the
parser's guess - a closed loop no coverage inside it could ever have escaped.
MUTATION.md habit 19 records it as the fourteenth instance of habit 4 and the
first where the fixture and the code under test shared a SHAPE, not a number.
WHAT CHANGED
* `_points_from_columnar_json()` - a SECOND function, not a sniff. A parser that
decides which document it received is one that can decide wrong, and a
wrong-but-parseable response then becomes a price. Feeding the row shape to
`generic_dayahead` is now a graded no_data.
* Unequal arrays are refused in both directions, with the two lengths in the
reason. `zip()` stops at the shorter list silently, and a truncated `price`
array would have produced a real series missing the evening peak - traded on
as complete, where no data at all switches arbitrage off.
* A unit that is not EUR/MWh is refused. The plugin converts with a fixed
0.001, and `MAX_PLAUSIBLE_EUR_KWH` only bounds prices that are too LARGE.
* `unix_seconds` are read as UTC instants explicitly; §9.3's Brussels rendering
stays in `assemble()` rather than being copied into the plugin, where a
mutation could not tell it from a no-op (M4 proved exactly that on a first
draft, and the line was removed rather than fenced).
* A published null is dropped and logged with a count; an all-null body is
no_data named by this parser rather than by the boundary validator.
FIXTURES
Two unmodified response bodies under `scenarios/`, captured by hand on
2026-09-10: quarter-hourly (2026-09-10, 96 points at 900 s) and hourly
(2025-09-10, 24 at 3600 s - the same endpoint before Belgium's 15-minute MTU).
`energy-charts-be-price-captures.json` records the URL, retrieval time, unit,
licence-as-returned and a sha256 of each, and the replay RE-DERIVES the
checksums, so a fixture edited to make a check pass stops being a capture. Data
CC BY 4.0, Bundesnetzagentur | SMARD.de, via Energy-Charts (Fraunhofer ISE),
published without changes - the same BE-zone licence check DATA-02 established.
The surviving invented fixtures are renamed `synthetic_row_feed` at every call
site. `engie_dynamic`, `totalenergies_dynamic` and `eneco_eddy` are untouched
and have no capture: their URLs are unverified and withdrawing them is
TARIFF-07's open decision. Nothing should read their green checks as evidence
that those feeds parse.
MUTATIONS - 12, all red, no survivors. Purged tree, mounted `:ro`, `python3 -B`
(TEST-15). M1 drop the equal-length refusal; M2 make it one-sided; M3 drop the
unit check; M4 `assemble()` stops rendering at the Brussels offset; M5 read
`unix_seconds` as a naive local clock; M6 zero-fill a null instead of dropping
it; M7 drop the all-null refusal; M8 sniff for the row shape; M9 drop the
deprecated warning; M10 drop the dropped-nulls warning; M11 edit one price in
the committed capture; M12 point `generic_dayahead` back at the row parser -
red across all three price suites.
END TO END, LIVE, 2026-09-10: `resolve_tariff()` returns a `TariffPlan`,
`origin='provider'`, 96 quarter-hourly points, spacing [900] s, no decimation,
first point 2026-09-10T00:00:00+02:00 at 0.30608 EUR/kWh all-in. FCST-04's H1
fix was never theoretical. All 29 test files green.
STILL OPEN: `generic_dayahead` asks for no date range, so the default URL
returns one published day - a full 48 h horizon is reached only through §8.3's
carry-forward fill.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
04292c4a08 |
DATA-01: thirty days of the real meter, and what AC 3 actually measures
checks / unit (pull_request) Successful in 3m36s
TARIFF-01 and SAFETY-07 both merged with AC 3 - "monthly peak held under
the soft limit in >= 95 % of intervals over a 30-day simulation replay" -
honestly unmet, because two days of capture existed and it was believed
nothing longer could be produced. That belief was a true statement about
the past read as a claim about the future: HA's recorder still held the
whole month, and the reason nobody found out is that the 2026-08-25
export was a one-off script that left no artefact.
So the exporter is committed and runnable now.
scenarios/p1-net-30d-2026-08/ is 2026-08-01 to 2026-08-30, 485,841
samples, 30/30 days read, 0 failed, 4.13 MB gzipped, in the schema the
two committed days already fixed.
VERIFIED AGAINST THE DAYS THAT EXIST. `--verify` re-fetches 2026-08-20
and 2026-08-23 by this exact route and reproduces both committed files
BYTE FOR BYTE after decompression (865,024 B / 15,600 samples and
894,387 B / 16,351 samples). The gzip containers differ by design: this
exporter writes mtime 0 so its output is reproducible, where the one-off
wrote a wall clock.
A FAILED READ IS NOT AN OBSERVATION. A day whose read fails writes no
file, is recorded "read": "FAILED", and the run exits non-zero; the
entity is proved to exist through /api/states before any empty day is
believed, because a typo would otherwise answer 200 [] thirty times and
produce a consistent dataset of nothing. Nothing is interpolated, so the
month's 13 gaps (1291 s, 99.95 % covered) and its 3 `unavailable`
samples stay visible as holes.
SIZE: COMMITTED, DELIBERATELY, AND MEASURED. A git bundle of the whole
history goes from 1.58 MB (release/1.0 @
|
||
|
|
d57122ec74 |
DATA-02: a real Belgian price year, so AC4 stops being unmeetable
checks / unit (pull_request) Successful in 3m36s
OPT-04 reported AC4 - "net-positive across 12 months of replayed prices" - as NOT MET and replayed a synthetic year, because scenarios/ held only P1 meter captures. Right call, wrong diagnosis: the criterion was being carried beside a 30-day METER criterion as though both needed waiting. EPEX BE day-ahead is public data, not a capture. It needed a fetch. 8760 hourly points, 2025-09-01 to 2026-09-01 Brussels-local, canonical three fields. Licence checked BEFORE committing: Energy-Charts publishes the BE zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de and other zones under private-use-only terms, so this one is redistributable with attribution. The fetcher refuses to write a file whose per-response license_info stops saying so. Cross-checked against SMARD's own 4996/DE: 96 of 96 quarter-hours, max difference 0.00 EUR/MWh. Raw wholesale, and the file says so. all_in: false, with the markup/tax assumption carried as numbers to APPLY rather than numbers applied - TARIFF-02's trap in data form. Section 7B applies it in one visible place and asserts arithmetically that its additive terms cancel out of every daily spread, so the trade count turns on the VAT multiplier alone; the raw replay is run too, so how much rests on the guess is reported (110 vs 88). DST by construction: iterate in UTC, render through price.brussels(). 2025-10-26 is 25 points, 2026-03-29 is 23, verified by counting per Brussels day rather than asserting 24, and by checking October's 02:00 appears twice at two offsets with two prices while March's never appears. Both bugs the point-and-gap accounting caught were real: a UTC-bounded window made the first day 22 hours, and an inclusive-end off-by-one dropped the last day silently. A day nobody asked for is not a day with no prices. THE RESULT, AT THE SHIPPED DEFAULT, WHATEVER IT IS. At 0.10 widened 1.5x to 0.1500: 110 round trips, +24.88 EUR net of the cycle cost. Unwidened, 173. Nothing tuned - the threshold and the 2.5/1.5 factors are untouched. And what the owner's decision now has under it: the four reports that a static ~0.0840 spread does not clear 0.10 all STAND. What was missing is that a dynamic site clears the widened requirement on 121 of 365 days, median all-in spread 0.1130, so a median day would clear at 0.0754 - 156 trips, +35.42 EUR. Reported, not applied. The synthetic year stays, because the real one cannot grade section 17: not one of 365 days has a negative DEAREST hour, so a zero there counts something that could not happen. 7B asserts that degeneracy rather than reporting the zero. Size measured, not assumed: 893 KB plain but 74.6 KB as a git object against 56.5 KB gzipped. Git already compresses; 18 KB is not worth making the provenance block - the licence claim a reviewer must check - unreadable in a diff. Nothing wired into the add-on; generic_dayahead is still the live path. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
f4914a174a |
TARIFF-01: measure the month's billed peak, and make it survive a restart
checks / unit (pull_request) Successful in 2m38s
The 15-minute block average was already built and unwired. p1.QuarterAverager computes clock-aligned 900 s blocks, time-weighted over irregular telegram spacing, offtake-only and per-phase; P1Ingest.blocks was a 96-entry list in memory that a restart erased. So this is the persistence and the monthly reduction, not a second accumulator - a second one would be a second source of truth for the exact quantity the money depends on. BLOCKS, NOT A SLIDING WINDOW. The card says "rolling"; 9.1 bills "the highest 15-minute average offtake" and states its own worked case per QUARTER - one 4998 W quarter moving a monthly peak from 4832 to 5013 W. A trailing window reports a peak the meter never bills, and reports it HIGH: a burst straddling :15 fills the window completely while contributing to two block averages at partial weight. DELIVERED, NOT INTENDED. tariff.py only ever sees P1Sample - the meter's own reading - and never a setpoint. SAFETY-20's open question does not arise for a capacity tariff: the utility integrates the current that flowed. AN UNREADABLE STORE IS NOT A ZERO PEAK. peak() answers OBSERVED / NO_RECORD / NOT_OBSERVED with peak_w None unless observed, which is riglock.holder()'s fix applied to something that spends money. A peak read as 0 W hands SAFETY-07 maximum headroom and disarms the guard at the moment its own storage breaks. Restart mid-block resumes the accumulator through a new snapshot()/restore() pair, checkpointed every 15 s and cleared in the same breath as a block close. The held sample keeps its ORIGINAL timestamp, so an outage is integrated under the same max_hold_s rule a running process would apply. quarter_start is the primary key and a re-bank may only ever RAISE a figure. Calendar months are LOCAL: a quarter starting 22:15 UTC on 31 August bills in September. No new option (the limit is the existing peak_cap_w), so config.yaml and validate.py are untouched and CFG-03 is not widened. No second peak entity: peak_forecast_entity stays the input to maintenance_charge_floor(), because repointing that consumer changes what moves energy and belongs to SAFETY-07. AC 3 is NOT met. It asks for 30 days of replay; two days of this house's real meter exist and are committed here. test_tariff.py part 9 replays them, reports the percentage next to the sample size in days, and asserts nothing about 95 %. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
7aa1bd052e |
SAFETY-18: a meter frozen at a wrong-but-fresh value now raises an alarm
A meter that answers 200 OK with a stale document forever is ARRIVING on every
poll, so every freshness mechanism in the stack reads it as healthy while the
loop integrates a constant error and rails: 360/135/75 s at the live install's
max_w: 5000 for a meter frozen at 350/1000/>=3000 W. Fifteen minutes of a 5 kW
unattended import sets the month's billed capaciteitstarief peak.
The detector is a conjunction, not the bare unchanged_s threshold TEL-05
measured and rejected:
unchanged_s >= meter_freeze_s AND |command| within 5 % of max_w
Both terms already existed and were already on the status page, and they fail
for independent reasons: at the converged point the command is nowhere near the
rail, and at the rail against a real load the kWh registers move in seconds. At
the shipped 300 s the relation is structural rather than a margin - the slowest
a healthy 1 Wh register can tick and still look unchanged is 12 W, which is
inside the 15 W deadband, so the command there is parked at 0 W.
Notification only, deliberately: an HA persistent notification with a fixed
notification_id, an ERROR log line, a UI event and a red status row. No claim,
no latch, no 0 W. A false trip parks the battery; a false notification costs an
alert. Only meter_source: homewizard_local is covered - the status page says
NOT COVERED elsewhere rather than pretending the guard is armed.
DOCS.md states the capacity-tariff exposure this does NOT close: peak_cap_w caps
maintenance charging and nothing caps the loop. That cap is SAFETY-07.
test_freeze.py grades both directions and was verified by breaking what it
watches (six mutations, all red): silent over the committed 40-minute converged
capture, silent over an hour of TEL-05's low-power case where the rejected bare
threshold is shown to fire, alarming on a genuinely frozen meter driven over
real HTTP through the real HomeWizardLocalSource (the rig's own hwsim freeze
fault when reachable), silent on the same railed command against a meter that is
still moving, and asserting on the service call that leaves Controller.cycle()
rather than on the watchdog's own flag.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|