OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
- arbiter: a mode now gives way only as far as a site limit above P_MODE
needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
released only when the peak floor bound S, so a trade won above the floor
kept them and placed less than the floor (an Off battery at N=1 went to 0 W
under a 2000 W floor), and a capped grid charge released an Off battery.
While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
(peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
loop bound counts live units only). DOCS and DECISIONS say the new rule.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
d69fd8fbfd
commit
ffc9a4d721
@@ -17,6 +17,7 @@ exists because its absence produced a specific, observed failure.
|
||||
"""
|
||||
|
||||
import math
|
||||
from math import inf
|
||||
from dataclasses import dataclass
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
@@ -500,6 +501,14 @@ def compute(
|
||||
# main.py never builds one: every term of `loop_bound()` holds 0).
|
||||
if bound is not None and not (bound[0] <= 0.0 <= bound[1]):
|
||||
bound = None
|
||||
# ...and a side of it that reaches the rail is left to the rail, so that
|
||||
# SAFETY-03's `i_clamped` still fires when the loop winds into it. With
|
||||
# every battery on, the bound IS the rail, and the law is exactly as it was.
|
||||
if bound is not None:
|
||||
_rail = min(tuning.max_w, tuning.max_w if tuning.integrator_max_w is None
|
||||
else tuning.integrator_max_w)
|
||||
bound = (float(bound[0]) if bound[0] > -_rail else -inf,
|
||||
float(bound[1]) if bound[1] < _rail else inf)
|
||||
|
||||
# --- saturation, WITH the duration term -------------------------------
|
||||
# Command and actual diverging means the inverter cannot follow - it is at
|
||||
@@ -603,9 +612,8 @@ def compute(
|
||||
i_w = max(moved, i_w)
|
||||
|
||||
# OPT-11: the integrator does not wind past what the modes let the
|
||||
# batteries place. Applied BEFORE the integrator bound below, so a loop
|
||||
# held by a mode reads as `mode-bound` and not as SAFETY-03's winding into
|
||||
# the rail (`i_clamped`). That bound still bites where it is the tighter.
|
||||
# batteries place. Only a side tighter than the rail is left in `bound`
|
||||
# (above), so this never takes SAFETY-03's `i_clamped` away from the rail.
|
||||
if bound is not None:
|
||||
held = max(float(bound[0]), min(float(bound[1]), i_w))
|
||||
if held != i_w:
|
||||
|
||||