@@ -1,7 +1,7 @@
|
||||
# GoodWe RS485 Controller
|
||||
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 meter bus: holds net grid
|
||||
exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port: sends it a grid
|
||||
reading to hold net grid exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
|
||||
balance cells and recalibrate its coulomb counter.
|
||||
|
||||
Installers: the printed field guide (`docs/GoodWe-RS485-Field-Guide.pdf`) is
|
||||
@@ -33,8 +33,8 @@ v0.1.0 and outdated; where it disagrees with this page, this page wins.
|
||||
|
||||
You need:
|
||||
|
||||
- A GoodWe **ES / BP family** inverter (AA55 / RS485 meter-bus generation)
|
||||
- The vendor's meter-emulating controller **disconnected** from the bus
|
||||
- A GoodWe **ES / BP family** inverter (AA55 generation)
|
||||
- The vendor's controller **disconnected** from the inverter's EMS port
|
||||
- A control board: a T-CAN485 (ESP32) flashed with
|
||||
`firmware/goodwe-master.yaml`
|
||||
- A grid-power sensor already working in Home Assistant, updating every ~5–10 s
|
||||
|
||||