DOC-8: say EMS port, not meter bus
The add-on is wired to the inverter's RS485 port labelled EMS. Reword README, DOCS, config description, field guide source and HTML. The HA manufacturer string is left unchanged: test_mqtt pins it byte for byte. Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
c67d0cdb67
commit
fd08090360
@@ -1,7 +1,7 @@
|
||||
# GoodWe RS485 Controller
|
||||
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 meter bus: holds net grid
|
||||
exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port: sends it a grid
|
||||
reading to hold net grid exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
|
||||
balance cells and recalibrate its coulomb counter.
|
||||
|
||||
Installers: the printed field guide (`docs/GoodWe-RS485-Field-Guide.pdf`) is
|
||||
@@ -33,8 +33,8 @@ v0.1.0 and outdated; where it disagrees with this page, this page wins.
|
||||
|
||||
You need:
|
||||
|
||||
- A GoodWe **ES / BP family** inverter (AA55 / RS485 meter-bus generation)
|
||||
- The vendor's meter-emulating controller **disconnected** from the bus
|
||||
- A GoodWe **ES / BP family** inverter (AA55 generation)
|
||||
- The vendor's controller **disconnected** from the inverter's EMS port
|
||||
- A control board: a T-CAN485 (ESP32) flashed with
|
||||
`firmware/goodwe-master.yaml`
|
||||
- A grid-power sensor already working in Home Assistant, updating every ~5–10 s
|
||||
|
||||
@@ -3,7 +3,7 @@
|
||||
WHAT THIS THING DOES, in one paragraph: it reads the house's net grid power from
|
||||
Home Assistant, decides how hard the battery should charge or discharge to hold
|
||||
that at zero, and writes that figure to an ESP32 which puts it on the inverter's
|
||||
RS485 meter bus. Once a month it runs a full low->full battery cycle so the BMS
|
||||
RS485 EMS port. Once a month it runs a full low->full battery cycle so the BMS
|
||||
can balance cells and recalibrate its coulomb counter.
|
||||
|
||||
⚠️ THE ONE THING TO UNDERSTAND BEFORE CHANGING ANY OF THIS: the inverter holds
|
||||
|
||||
@@ -2,8 +2,8 @@ name: GoodWe RS485 Controller
|
||||
version: "0.18.2"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
meter, holding net grid exchange at zero and running a monthly battery
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port by sending it a
|
||||
grid reading, holding net grid exchange at zero and running a monthly battery
|
||||
maintenance cycle.
|
||||