MAINT-14: maintenance with no SoC reading: charge times out, drain holds at 0 W
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
8a17711f60
commit
f39e52efd3
@@ -84,6 +84,10 @@ FAIL_BACKOFF_DAYS = 7
|
||||
CHARGE_TICK_MAX_MIN = 5
|
||||
# The charge accounting is written to the state file at most this often.
|
||||
CHARGE_SAVE_MIN = 5
|
||||
# MAINT-14 (DECISIONS/MAINT-14-no-soc-in-maintenance.md): with no SoC reading
|
||||
# the timeouts still run, a drain holds at 0 W, and the log says once, after this
|
||||
# many minutes, that the level has been unknown for long.
|
||||
NOSOC_NOTE_MIN = 15
|
||||
|
||||
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR EVERY `maintenance_*`
|
||||
# OPTION, and the only place in the add-on where one of these numbers is typed.
|
||||
@@ -367,6 +371,10 @@ class Maintenance:
|
||||
# written to the state file every CHARGE_SAVE_MIN minutes.
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
# MAINT-14: when the SoC reading went missing (None while it is there),
|
||||
# and whether the "unknown for long" line was said in this episode.
|
||||
self._nosoc_since = None
|
||||
self._nosoc_said = False
|
||||
|
||||
# -- state ---------------------------------------------------------------
|
||||
@property
|
||||
@@ -374,6 +382,7 @@ class Maintenance:
|
||||
return self.store.get("phase", IDLE)
|
||||
|
||||
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
|
||||
self._nosoc_since = None
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
if self.store.get("charge_track") is not None:
|
||||
@@ -473,7 +482,8 @@ class Maintenance:
|
||||
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
|
||||
return events
|
||||
|
||||
def _charge_account(self, now: datetime, soc: float, gate_open: bool) -> dict:
|
||||
def _charge_account(self, now: datetime, soc: float | None,
|
||||
gate_open: bool) -> dict:
|
||||
"""MAINT-13: what this charge has used so far, as minutes of ALLOWED time.
|
||||
|
||||
`open_min` counts only ticks with the price gate open; `flat_min` counts
|
||||
@@ -481,6 +491,9 @@ class Maintenance:
|
||||
both. One tick adds at most CHARGE_TICK_MAX_MIN, so a gap (add-on down)
|
||||
counts for nothing. A state file from before MAINT-13, or from another
|
||||
charge, starts from the wall-clock minutes so far: the old behaviour.
|
||||
|
||||
MAINT-14: `soc` may be None (no reading). Time still counts, the stall
|
||||
wait pauses, and `last` keeps the last SoC seen (saved with the rest).
|
||||
"""
|
||||
since = self.store.get("phase_started")
|
||||
trk = self._trk
|
||||
@@ -490,7 +503,9 @@ class Maintenance:
|
||||
trk = dict(raw)
|
||||
else:
|
||||
trk = {"since": since, "open_min": self._elapsed_min(now),
|
||||
"flat_min": 0.0, "best": float(soc), "at": None}
|
||||
"flat_min": 0.0,
|
||||
"best": None if soc is None else float(soc),
|
||||
"last": None if soc is None else float(soc), "at": None}
|
||||
self._trk = trk
|
||||
at = trk.get("at")
|
||||
try:
|
||||
@@ -500,10 +515,14 @@ class Maintenance:
|
||||
dt = 0.0 if last is None else min(
|
||||
CHARGE_TICK_MAX_MIN, max(0.0, (now - last).total_seconds() / 60.0))
|
||||
trk["at"] = now.isoformat()
|
||||
if soc > trk["best"]:
|
||||
if soc is None:
|
||||
pass
|
||||
elif trk.get("best") is None or soc > trk["best"]:
|
||||
trk["best"], trk["flat_min"] = float(soc), 0.0
|
||||
elif gate_open:
|
||||
trk["flat_min"] += dt
|
||||
if soc is not None:
|
||||
trk["last"] = float(soc)
|
||||
if gate_open:
|
||||
trk["open_min"] += dt
|
||||
saved = self._trk_saved
|
||||
@@ -522,6 +541,57 @@ class Maintenance:
|
||||
events.append(msg)
|
||||
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
|
||||
|
||||
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
|
||||
events: list) -> MaintResult:
|
||||
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
|
||||
|
||||
HOLD is unchanged (0 W). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
|
||||
time is a failure, except when the last SoC seen was within
|
||||
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
|
||||
Nothing here may start a phase change that needs the level.
|
||||
"""
|
||||
if self._nosoc_since is None:
|
||||
self._nosoc_since = now
|
||||
self._nosoc_said = False
|
||||
self._trk_saved = None # save the last SoC seen, now
|
||||
if phase == DRAIN:
|
||||
msg = ("maintenance: the battery level is unknown, so the "
|
||||
"drain holds at 0 W until it is back.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
|
||||
>= NOSOC_NOTE_MIN * 60):
|
||||
self._nosoc_said = True
|
||||
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
|
||||
f"The time limit of the {phase} still applies.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
elapsed = self._elapsed_min(now)
|
||||
if phase == DRAIN:
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
return self._fail(now, "drain",
|
||||
f"drain stuck, battery level unknown, after "
|
||||
f"{elapsed / 60:.0f} h")
|
||||
return MaintResult(DRAIN, True, 0.0, False, events)
|
||||
trk = self._charge_account(now, None, gate_open)
|
||||
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
|
||||
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
|
||||
last = trk.get("last")
|
||||
if last is not None and last >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: charge time is up and the last level "
|
||||
f"seen was {last:.0f} %, close enough to full, so the "
|
||||
f"charge counts as done -> holding "
|
||||
f"{self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._fail(now, "charge",
|
||||
f"charge stuck, battery level unknown, after "
|
||||
f"{trk['open_min'] / 60:.0f} h of charging time")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
def abort(self, now: datetime, why: str) -> list:
|
||||
events = []
|
||||
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
|
||||
@@ -609,13 +679,13 @@ class Maintenance:
|
||||
# transitions below mean anything, and a stale "100 %" would end the
|
||||
# charge phase having charged nothing. Hold the current phase's command
|
||||
# and wait; the phase timeout is the backstop.
|
||||
#
|
||||
# MAINT-14: "hold and wait" is not "wait for ever". The timeouts run
|
||||
# here too, and a drain holds at 0 W (an unknown level never allows
|
||||
# discharge, TEL-08). See `_no_soc`.
|
||||
if soc is None:
|
||||
_LOG.warning("maintenance: no SoC reading, holding phase %s", phase)
|
||||
if phase == DRAIN:
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
return self._no_soc(now, phase, gate_open, events)
|
||||
self._nosoc_since = None
|
||||
|
||||
elapsed = self._elapsed_min(now)
|
||||
|
||||
|
||||