SAFETY-42: close two mutation gaps, and correct what makes N=1 inert
checks / unit (pull_request) Successful in 6m3s
checks / unit (pull_request) Successful in 6m3s
The battery is 12 mutations, one freshly copied tree each, purged, `:ro`,
`python3 -B`, byte deltas measured. First round: 9 red, 3 survivors. All three
are now accounted for and the ledger is in DECISIONS §8.
M5 - `share <= 0` relaxed to `share == 0`, +0 B - WAS A REAL GAP AND THE TWO
OBVIOUS CHECKS DID NOT CLOSE IT. `short_by(-2000, 0) is None` and
`short_by(-2000, -100) is None` both stayed GREEN under the mutant: for a charge
share that is UNDER-delivered `share - measured` is negative and the `gap > 0`
test answers None anyway, so neither input can separate the two spellings. The
one that can is a unit moving MORE than its charge share - -2000 W told,
-3000 W measured, `share - measured` = +1000 W - which the mutant reports as a
shortfall. It is not one; it is something else driving that pack, which is
SAFETY-30's and SAFETY-31's question. That input is now the check, and M5 is RED.
MUTATION.md's third failure mode in miniature: the assertion ran, the sentence
was true, and the data could not reach the failure it named.
M11 - `inv.is_live(now)[0]` replaced by a literal `True`, -15 B - was a WIRING
gap the pure checks structurally could not see. `account(live=False, ...)` was
graded as a FUNCTION; nothing graded that `cycle()` asks the question, because no
fixture had a unit whose writes were being rejected. Such a unit still has its
last ACCEPTED command standing on the wire (`write_setpoint` leaves `last_write`
alone on a rejected write) and still measures nothing, so it looks exactly like a
wedged one to every number this check reads - and reporting it would be the
second, louder alarm about a state the allocator has already handled and logged.
`test_delivery.py` part 6 now builds that unit, with `rejected_since` back-dated
past LINK_STALE_S because the fixture runs in two seconds and the timer is
test_inverter.py's to grade. M11 is RED.
M3 - `len(asked) < 2` relaxed to `< 1`, +0 B - IS STILL A SURVIVOR, and it is an
EQUIVALENT MUTANT. With one asked unit `unaccounted` is a subset of a one-element
set, so it is either empty (`not unaccounted` returns {}) or equal to `asked`
(`len(unaccounted) == len(asked)` returns {}); with zero asked units both
spellings return {} as well. No input separates them, so no check can.
⚠️ AND FINDING IT CORRECTED THE MODULE'S OWN PROSE, WHICH IS THE MORE USEFUL
HALF. `delinquent()`'s docstring claimed `len(asked) < 2` was what makes N=1
inert. It is not - the PROPER-SUBSET rule is, and that line is a fast path and a
signpost. A false attribution of the mechanism in the file's own prose is exactly
what this repository keeps finding, and a mutation that survives is how it
surfaced. The line stays, with the equivalence written down beside it the way
circulation.circulating_w() records its own max(0.0, ...).
Also recorded, rather than left implicit: `account()`'s `parked` branch is graded
as a function but its WIRING is not mutated on its own; part 6's reversed-unit
fixture exercises it end to end, which is weaker, and the ledger says so.
Baseline 23/23 green before and after. app/main.py is byte-identical to the
previous commit - both closures are a test and a comment.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
co-authored by
Claude Opus 5
parent
ccc4bf100c
commit
eae9e23e95
@@ -425,3 +425,81 @@ it is working.
|
||||
|
||||
## 8. Mutation ledger
|
||||
|
||||
Every run on a **freshly copied tree of its own, `__pycache__` purged and the
|
||||
count printed, mounted `:ro`, `python3 -B`** — MUTATION.md's rule, followed
|
||||
because the first SAFETY-30 battery reused one directory, a container mounted it
|
||||
mid-copy, read a missing `config.yaml` as a failing check, and the whole run was
|
||||
discarded. **The baseline is green** (23/23) or nothing below is a result. Byte
|
||||
deltas measured, not estimated; the `+0 B` ones are marked, since a
|
||||
size-preserving edit is what TEST-15 turned into a false survivor once already.
|
||||
|
||||
| # | file | mutation | Δ | result |
|
||||
|---|---|---|---|---|
|
||||
| M1 | `delivery.py` | the SoC account removed — a cold pack at its floor alarms | −31 B | **RED** — `test_delivery.py`. This is the card |
|
||||
| M2 | `delivery.py` | the proper-subset rule removed — a whole-site cause names every unit | −34 B | **RED** |
|
||||
| **M3** | `delivery.py` | **the `len(asked) < 2` fast path relaxed to `< 1`** | **+0 B** | **SURVIVOR — and an EQUIVALENT MUTANT.** See below |
|
||||
| M4 | `delivery.py` | the strict bound relaxed to `>=` — a gap the control law calls tracking is named | +1 B | **RED** |
|
||||
| **M5** | `delivery.py` | `share <= 0` relaxed to `share == 0` — charge shares graded | **+0 B** | **SURVIVOR on the first battery — GAP CLOSED**, then **RED**. See below |
|
||||
| M6 | `delivery.py` | `delivery_hold_s` 185 → a round 300 | **+0 B** | **RED** — the CFG-03 pin |
|
||||
| M7 | `main.py` | the watts threshold no longer `Tuning.saturation_w` (×4) | +6 B | **RED** |
|
||||
| M8 | `main.py` | the latch never persisted — nothing survives a restart | −35 B | **RED** |
|
||||
| M9 | `main.py` | `_delivery_announced` never set — one notification per cycle | −34 B | **RED** |
|
||||
| M10 | `main.py` | `peakguard.pack_floor_pct()`'s conjunction with `peak_soc_floor` used instead of the pack's own cut-out | +151 B | **RED** — the between-the-floors fixture |
|
||||
| **M11** | `main.py` | **`inv.is_live(now)[0]` replaced by a literal `True`** | −15 B | **SURVIVOR at review — GAP CLOSED**, then **RED**. See below |
|
||||
| M12 | `inverter.py` | the latch not restored from the store on start-up | −46 B | **RED** |
|
||||
|
||||
**11 of 12 red. One survivor, argued rather than left.**
|
||||
|
||||
### M5 was a real gap, and the two obvious checks did not close it
|
||||
|
||||
`test_delivery.py` already asserted `short_by(-2000, 0) is None` and
|
||||
`short_by(-2000, -100) is None` — and **both stayed green under the mutant**.
|
||||
For a charge share that is *under*-delivered, `share − measured` is negative and
|
||||
the `gap > 0` test answers `None` anyway, so those two inputs cannot separate
|
||||
`share <= 0` from `share == 0`. The one input that can is a unit moving **more**
|
||||
than its charge share — `-2000 W` told, `-3000 W` measured, `share − measured` =
|
||||
`+1000 W` — which the mutant reports as a shortfall. It is not one; it is
|
||||
something else driving that pack, which is SAFETY-30's and SAFETY-31's question.
|
||||
The check now uses that input and the mutant is red.
|
||||
|
||||
This is MUTATION.md's third failure mode in miniature: **the assertion ran, the
|
||||
sentence was true, and the data could not reach the failure it named.**
|
||||
|
||||
### M11 was a wiring gap the pure checks structurally could not see
|
||||
|
||||
`account(live=False, …)` was already graded — as a **function**. What was not
|
||||
graded was that `cycle()` actually *asks* `inv.is_live(now)`, and replacing that
|
||||
call with a literal `True` left every check green, because **no fixture had a
|
||||
unit whose writes were being rejected**. A dropped unit still has its last
|
||||
*accepted* command standing on the wire (`write_setpoint` leaves `last_write`
|
||||
alone on a rejected write) and still measures nothing, so it looks exactly like a
|
||||
wedged one to every number this check reads — and reporting it would be the
|
||||
second, louder alarm about a state already being handled that this module takes
|
||||
its 30 s floor from. `test_delivery.py` part 6 now builds that unit (with
|
||||
`rejected_since` back-dated past `LINK_STALE_S`, because the fixture runs in two
|
||||
seconds and the timer is `test_inverter.py`'s to grade) and the mutant is red.
|
||||
|
||||
### M3 is recorded as a survivor because it is one — and it is EQUIVALENT
|
||||
|
||||
`len(asked) < 2` → `len(asked) < 1`. With **one** asked unit, `unaccounted` is a
|
||||
subset of a one-element set, so it is either empty — `not unaccounted` returns
|
||||
`{}` — or equal to `asked` — `len(unaccounted) == len(asked)` returns `{}`.
|
||||
There is no third case, and with **zero** asked units both spellings return `{}`
|
||||
as well. **No input separates them**, so no check can, and one written to try
|
||||
would be a check about nothing.
|
||||
|
||||
⚠️ **And finding it corrected the module's own docstring, which is the more
|
||||
useful half.** That paragraph claimed `len(asked) < 2` was *what makes N=1
|
||||
inert*. It is not: the **proper-subset rule** is, and the line is a fast path and
|
||||
a signpost. A false attribution of the mechanism in the file's own prose is
|
||||
exactly what this repository keeps finding, and a mutation that survives is how
|
||||
it surfaced. The line stays — it tells a reader at a glance that a one-inverter
|
||||
install never reaches any of this — with the equivalence written down beside it,
|
||||
the way `circulation.circulating_w()` records its own `max(0.0, …)`.
|
||||
|
||||
### Not separately mutated, and said rather than left implicit
|
||||
|
||||
`account()`'s `parked` branch is graded as a function (part 1) but its **wiring**
|
||||
— `parked=inv.sign_wd.tripped` — is not mutated on its own. Part 6's reversed-unit
|
||||
fixture exercises the path end to end and asserts the account it produces, which
|
||||
is weaker than a mutation and is stated as such.
|
||||
|
||||
@@ -491,11 +491,24 @@ def delinquent(units, min_w: float) -> dict:
|
||||
wedged at once. Reporting it anyway would be the saturation-shaped alarm
|
||||
`clamp.py` warns about, produced by the guard written to replace it.
|
||||
|
||||
⚠️ AND THAT IS WHY N=1 IS INERT WITHOUT A ROSTER GUARD. `asked` has at most
|
||||
one element there, `len(asked) < 2` short-circuits, and every input answers
|
||||
`{}`. A `if n_units > 1` in the caller would be a second place the same
|
||||
decision lives; the algebra is the guard, the same way
|
||||
`circulation.circulating_w()` is identically zero at N<=1.
|
||||
⚠️ AND THAT IS WHY N=1 IS INERT WITHOUT A ROSTER GUARD. A `if n_units > 1`
|
||||
in the caller would be a second place the same decision lives; the algebra
|
||||
is the guard, the same way `circulation.circulating_w()` is identically zero
|
||||
at N<=1.
|
||||
|
||||
⚠️ BUT THE ALGEBRA THAT DOES IT IS THE PROPER-SUBSET RULE, NOT THE
|
||||
`len(asked) < 2` LINE - AND THIS PARAGRAPH USED TO SAY OTHERWISE. The
|
||||
mutation battery found it: relaxing that line to `len(asked) < 1` is a
|
||||
SURVIVOR at +0 B, and it is an EQUIVALENT MUTANT rather than a gap in the
|
||||
checks. With one asked unit, `unaccounted` is a subset of a one-element set,
|
||||
so it is either empty (`not unaccounted` returns `{}`) or equal to `asked`
|
||||
(`len(unaccounted) == len(asked)` returns `{}`). There is no third case and
|
||||
no input on which the two spellings differ. The line is a FAST PATH and a
|
||||
signpost, not the mechanism - said here rather than left for the next
|
||||
mutation sweep to rediscover, exactly as `circulation.circulating_w()` says
|
||||
of its own `max(0.0, ...)`. Do not report its survival as a gap in the
|
||||
checks, and do not delete it either: it is what tells a reader at a glance
|
||||
that a one-inverter install never reaches any of this.
|
||||
"""
|
||||
asked = [u for u in units
|
||||
if u.share_w is not None and float(u.share_w) > 0.0]
|
||||
|
||||
@@ -28,7 +28,7 @@ from app.delivery import (
|
||||
DELIVERY_OPTION_DEFAULTS, REASON_CODE, DeliveryConfig, DeliveryWatchdog,
|
||||
UnitDelivery, account, delinquent, short_by,
|
||||
)
|
||||
from app.inverter import Inverter
|
||||
from app.inverter import LINK_STALE_S
|
||||
from app.main import Controller
|
||||
from app.peakguard import discharge_permitted
|
||||
from app.store import unit_key
|
||||
@@ -61,6 +61,19 @@ check("...a CHARGE share answers None. There is no configured charge ceiling "
|
||||
"in this add-on, so a pack in constant-voltage taper cannot be explained "
|
||||
"and arming it would fire on every maintenance charge",
|
||||
short_by(-2000, 0) is None and short_by(-2000, -100) is None)
|
||||
# ⚠️ THE CASE THAT ACTUALLY GRADES THE `share <= 0` GUARD, AND THE MUTATION
|
||||
# BATTERY IS WHAT FOUND IT MISSING. Relaxing that guard to `share == 0` left the
|
||||
# two rows above GREEN - for a charge share that is UNDER-delivered,
|
||||
# `share - measured` is negative and the `gap > 0` test answers None anyway, so
|
||||
# the mutant is masked. The one input where the two differ is a unit moving MORE
|
||||
# than its charge share: -2000 W told, -3000 W measured, `share - measured` =
|
||||
# +1000 W, which the mutant reports as a SHORTFALL. It is not one - it is
|
||||
# something else driving that pack, which is SAFETY-30's and SAFETY-31's
|
||||
# question - and reading it as "short of its share" would name the wrong fault.
|
||||
check("...and a unit moving MORE than its charge share is not short of it "
|
||||
"either. This is the input that separates `share <= 0` from `share == 0`; "
|
||||
"the two rows above do not, because the `gap > 0` test masks them",
|
||||
short_by(-2000, -3000) is None and short_by(-2000, -2600) is None)
|
||||
check("...a missing reading is None, never 'the whole share'. Zero would be "
|
||||
"this check inventing a fault out of an absence",
|
||||
short_by(2000, None) is None and short_by(None, 0) is None)
|
||||
@@ -590,6 +603,86 @@ check("...and it fires IDENTICALLY on the benign arm, on the identical trace, "
|
||||
and _cf.site_batt_w == _cw.site_batt_w
|
||||
and _cf.target == _cw.target)
|
||||
|
||||
print()
|
||||
print(" ...and a unit the ALLOCATOR HAS ALREADY DROPPED is not reported twice")
|
||||
# ⚠️ A WIRING CHECK THE PURE ONE IN PART 1 CANNOT MAKE, AND THE MUTATION BATTERY
|
||||
# IS WHAT FOUND IT MISSING. `account(live=False, ...)` is graded up there; what
|
||||
# is graded HERE is that `cycle()` actually ASKS `inv.is_live(now)`. Replacing
|
||||
# that call with a literal `True` left every check green, because no fixture had
|
||||
# a unit whose writes were being rejected. A dropped unit still has its last
|
||||
# ACCEPTED command standing on the wire (`write_setpoint` leaves `last_write`
|
||||
# alone on a rejected write) and still measures nothing, so it looks exactly
|
||||
# like a wedged one - and reporting it would be a second, louder alarm about a
|
||||
# state the allocator has already handled and logged, which is the
|
||||
# SAFETY-15/SAFETY-19 failure this module takes its 30 s floor from.
|
||||
|
||||
|
||||
class _LinkDeadHass(_DeliveryHass):
|
||||
"""B is healthy, then its LINK dies: writes rejected and output gone.
|
||||
|
||||
⚠️ `rejected_since` IS BACK-DATED RATHER THAN WAITED OUT. `is_live()`'s
|
||||
window is `LINK_STALE_S` = 30 s of wall clock and this fixture runs in about
|
||||
two; waiting it out would make the check's runtime the thing it grades. What
|
||||
is graded is the CALL, not the timer - `test_inverter.py` part 3 owns the
|
||||
timer.
|
||||
"""
|
||||
|
||||
def __init__(self, dead_from=5, **kw):
|
||||
super().__init__(**kw)
|
||||
self.dead_from = int(dead_from)
|
||||
self.cycle_n = 0
|
||||
|
||||
def measured(self):
|
||||
a, b = self.ctrl.inverters
|
||||
w = lambda i: float((i.last_write if i.last_write is not None
|
||||
else i.target) or 0.0)
|
||||
return [w(a), 0.0 if self.cycle_n >= self.dead_from else w(b)]
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append((entity, float(value)))
|
||||
if entity == "number.sp_b" and self.cycle_n >= self.dead_from:
|
||||
return False
|
||||
return True
|
||||
|
||||
|
||||
async def _link_dead():
|
||||
hass = _LinkDeadHass(dead_from=5)
|
||||
c = _ctrl(hass)
|
||||
b = c.inverters[1]
|
||||
seen = []
|
||||
for n in range(18):
|
||||
hass.cycle_n = n
|
||||
if n == 5:
|
||||
# the moment the link dies, back-dated past the firmware's window
|
||||
b.rejected_since = (datetime.now(timezone.utc)
|
||||
- timedelta(seconds=LINK_STALE_S + 10))
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
seen.append(dict(live=b.is_live(datetime.now(timezone.utc))[0],
|
||||
stood=float(b.standing_w()), meas=b.batt,
|
||||
named=b.delivery_wd.tripped))
|
||||
await asyncio.sleep(0.15)
|
||||
return c, seen
|
||||
|
||||
|
||||
_cld, _sld = asyncio.run(_link_dead())
|
||||
_bld = _cld.inverters[1]
|
||||
check("the fixture REACHES the case: B is not live, is still standing at a "
|
||||
"discharge command, and is measuring nothing - i.e. it looks exactly like "
|
||||
"a wedged unit to every number this check reads",
|
||||
not _sld[-1]["live"] and _sld[-1]["stood"] > _cld.tuning.saturation_w
|
||||
and _sld[-1]["meas"] == 0.0)
|
||||
check("...and it is NOT reported, because `account()` was asked and answered. "
|
||||
"The allocator has already dropped it and said so in the action log; a "
|
||||
"second alarm about that is the SAFETY-15/19 failure",
|
||||
not _bld.delivery_wd.tripped and _bld.delivery_wd.since is None)
|
||||
check("...and the answer is the LINK one specifically, not the SoC one - so a "
|
||||
"reader can tell which branch withheld the alarm",
|
||||
"link" in (account(live=False, parked=False, soc=_bld.soc,
|
||||
bms_floor=_bld.bms_soc_floor) or ""))
|
||||
print(f" B: live={_sld[-1]['live']} standing={_sld[-1]['stood']:.0f} W "
|
||||
f"measured={_sld[-1]['meas']:.0f} W -> not reported")
|
||||
|
||||
print()
|
||||
print(" ...and the one case where BOTH have something to say: a unit that is")
|
||||
print(" REVERSED is short too, and SAFETY-30 gets there first")
|
||||
|
||||
Reference in New Issue