EV-05 round 6: grade the car out only while Solar can cut it
Review of 69f5818:
- Solar grades the car out of the peak alarms only while it can really cut
it (not under another writer's hold, a refused or given-up write, an
untaken way-out 0 A, a charger fault, an unreadable charger). Otherwise
the alarms stand as in Off and the quarter is banked as the car's.
- A battery refusing to give counts for nothing at every N (N=1:
Controller.batt_refused); the site safety stops leave none able; a
battery switched Off still counts (the guard draws on it).
- Only pressing Solar lifts Solar's other-writer hold: leaving Solar, or
setting Manual's values, no longer writes over another writer (N10).
Tests: Solar vs Off twins for another writer, a refused cut write and a
refused fault 0 A; N=1 refusing battery against a car-Off twin; N10 on every
exit and on Manual value changes; the able_w cap; batteries switched Off.
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
@@ -95,6 +95,22 @@ inputs (`car_sun_inputs`) and runs the writer in the same background task.
|
||||
it had headroom and the cut waited (review repro: battery A refuses, house to
|
||||
20 950 W, period 3436 W against the twin's 3363 W).
|
||||
|
||||
## Round 6 (review of 69f5818)
|
||||
|
||||
- **Solar grades the car out of the peak alarms only while it can cut it**
|
||||
(`ctl_car.car_solar_can_cut`): not while another writer holds the charger,
|
||||
a write of ours was refused or given up, a way-out 0 A is not taken, the
|
||||
charger shows a fault or cannot be read. Otherwise the normal alarms stand
|
||||
as in Off, and the quarter is banked as the car's (it can set the peak).
|
||||
- **A refusing battery counts for nothing at every N**: at N=1 the refusal is
|
||||
`Controller.batt_refused` (SAFETY-52). The site's own safety stops (circulation,
|
||||
site sign) leave no battery able to give.
|
||||
- **A battery switched Off still counts for the headroom**: the peak guard's
|
||||
floor draws on it, so it can catch a cloud edge.
|
||||
- **Only pressing Solar lifts Solar's other-writer hold.** Leaving Solar (Off,
|
||||
Manual) or setting Manual's current or phases is not the user taking the
|
||||
charger back, so nothing is written over that writer (N10).
|
||||
|
||||
## Solar kWh
|
||||
|
||||
Per cycle in Solar: `min(car power, max(0, spare - room))` Batteries first,
|
||||
|
||||