Release 0.15.0: correct the SAFETY-94/97 row, add the ±170 W known issue
Review round 1 (F1-F3) on PR #173. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
f01152b113
commit
8c6e5bca2e
@@ -8,13 +8,14 @@ start 0.14.0 also start 0.15.0. The changes below apply with one inverter and
|
||||
with two.
|
||||
|
||||
The add-on now learns and saves, per battery, what its power reading shows
|
||||
at rest (`unit/<name>/idle_w`). There is nothing to set.
|
||||
at rest (`unit/<name>/idle_w`). It learns it after about two quiet minutes and
|
||||
uses 0 W until then, as before. There is nothing to set.
|
||||
|
||||
Contents of this release, in merge order since 0.14.0 (`02ed120`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `cf705a9` | No more false "battery power reading stopped changing" stops at a new command after a rest, or at a change of phase. Each one held a battery at 0 W for about 17 s (about 4 a day on a live site). A healthy battery that lags or turns around is no longer held as refusing for up to 15 min. Each battery learns its own reading at rest (some show about −100 W), so a battery that refuses is still caught, now also with two inverters. The rest value used is limited to ±75 W ([[SAFETY-94]], [[SAFETY-97]], also fixes [[SAFETY-58]]) |
|
||||
| `cf705a9` | No more false "battery power reading stopped changing" errors at a new command after a rest, or at a change of phase. Each one paused control for a few seconds (several a day on a live site). A healthy battery that lags or turns around is no longer held as refusing for up to 15 min. With two inverters, a refusing battery whose reading at rest is about −100 W is now caught too. The rest value used is limited to ±75 W ([[SAFETY-94]], [[SAFETY-97]], also fixes [[SAFETY-58]]) |
|
||||
| `3129dae` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-14]]) |
|
||||
|
||||
### Known issues
|
||||
@@ -22,6 +23,7 @@ Contents of this release, in merge order since 0.14.0 (`02ed120`):
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
|
||||
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
|
||||
- A battery whose reading at rest is beyond about ±170 W is still not caught when it refuses, as in 0.14.0 ([[SAFETY-97]]).
|
||||
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]).
|
||||
- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]).
|
||||
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
|
||||
|
||||
Reference in New Issue
Block a user