OPT-11 P3 option A review: wizard no longer says modes come later
checks / unit (pull_request) Successful in 15m14s
infra-pin / fresh (pull_request) Successful in 1s

Step 5 said "Choosing a mode for each battery comes in a later update",
stale since P1. It now points to battery modes on the Batteries screen
(EN/NL); test_setup checks the new line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-09-29 11:21:32 +02:00
co-authored by Claude Opus 5.5
parent 6dab4ec16b
commit 7104515229
3 changed files with 4 additions and 4 deletions
+1 -1
View File
@@ -209,7 +209,7 @@
"5": {"name": "Peak limit", "description": "The grid stays under this limit, averaged over each 15-minute period."},
"6": {"name": "Check and start", "description": "The add-on checks everything with its own start checks, then restarts."}
},
"modes_later": {"description": "Choosing a mode for each battery comes in a later update."},
"modes_later": {"description": "After setup, turn on battery modes to choose a mode for each battery on the Batteries screen."},
"kettle": {
"name": "Check the direction",
"description": "Read the meter, switch on a kettle, then read the meter again.",
+1 -1
View File
@@ -190,7 +190,7 @@
"5": {"name": "Piekgrens", "description": "Het net blijft onder deze grens, gemiddeld over elk kwartier."},
"6": {"name": "Nakijken en starten", "description": "De add-on kijkt alles na met zijn eigen startcontroles en herstart dan."}
},
"modes_later": {"description": "Een modus kiezen per batterij komt in een latere update."},
"modes_later": {"description": "Zet na de installatie batterijmodi aan om per batterij een modus te kiezen op het scherm Batterijen."},
"kettle": {
"name": "Richting nakijken",
"description": "Lees de meter af, zet een waterkoker aan en lees de meter opnieuw af.",
+2 -2
View File
@@ -76,8 +76,8 @@ check("the mockup's six steps: meter, inverters, solar, prices, peak limit, "
and [WS["steps"][str(n)]["name"] for n in range(1, 7)]
== ["Your meter", "Inverters and batteries", "Solar", "Prices",
"Peak limit", "Check and start"])
check("battery modes are not a step yet (OPT-11): step 5 says they come later",
"later update" in WS["modes_later"]["description"]
check("battery modes are not a wizard step (OPT-11): step 5 points to the Batteries screen",
"Batteries screen" in WS["modes_later"]["description"]
and not any("mode" in k for k in BY_STEP[5]))
SPEC = uipage.setup_spec()
check("the spec the page reads is the table's",