SAFETY-04: exactly zero is its own case in the freeze tie-break
`min(moved, i_w) if i_w > 0 else max(moved, i_w)` files i_w == 0.0 under rising-only, so the first push toward charging from exactly zero was blocked permanently - the S-1 deadlock again, mirrored in sign. main.py resets i_w to exactly 0.0 on every stop and every reseed, so it is a normal state. Zero is now handled explicitly and both directions are allowed: nothing is wound, so "may not wind further" has no referent, and a first step from zero is bounded by the gain, the output clamp and the slew limit like any other. Measured before the fix, at i_w == 0.0 and frozen: 12 800 of 25 920 ticks held the integrator and 8 304 of those changed the emitted command, worst case abandoning a 2 kW charge into a 4 kW export. Note this is NOT the same as the reported symptom: at prev_w == 0 the command holds at 0 W either way, because the output freeze forbids starting a charge while saturated, and that rule is release/1.0's and unchanged. There is now a test asserting it deliberately. Tests. The durable part is a property rather than more points: over 13 041 frozen states the integrator may be held ONLY by a correction pushing it further from zero on the side it already sits, and any other hold fails. Both signs at exactly 0.0. Mirrors added everywhere the suite tested one direction of two - freeze wind/unwind while charging, i_w=-100, the export-direction runaway, the negative clamp and slew. DOCS: the cycles-vs-seconds deviation is now written down as a deviation - the "> 10 s" criterion is not met as literally written, a cycle is one CHANGED meter reading, and there is no guaranteed wall-clock window. test_control.py: 43 -> 55 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
This commit is contained in:
co-authored by
Claude Opus 5
parent
7123aa00a4
commit
53d301b920
@@ -59,12 +59,35 @@ phase having charged nothing.
|
||||
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
|
||||
| `step_w` | 10 | Quantisation |
|
||||
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. **Do not set to 1** |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** |
|
||||
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
|
||||
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
|
||||
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W |
|
||||
| `auto_start` | false | Start controlling on boot (only after commissioning) |
|
||||
|
||||
#### Saturation is counted in cycles, not seconds
|
||||
|
||||
The specification states the saturation window as **"> 10 s"**. This add-on counts
|
||||
**cycles** instead, and that is a deliberate, accepted deviation rather than an
|
||||
oversight - the acceptance criterion is not met as literally written.
|
||||
|
||||
A cycle here is one *changed* meter reading: the controller only runs the loop when the
|
||||
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
|
||||
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
|
||||
window** - a meter that repeats the same value stalls the counter for as long as it
|
||||
repeats.
|
||||
|
||||
Two reasons that is acceptable:
|
||||
|
||||
- the control law is a pure function with no clock, which is what makes it testable
|
||||
without hardware, and a seconds-based window would have to live in the controller;
|
||||
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
|
||||
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
|
||||
while it is stalled.
|
||||
|
||||
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
|
||||
and treat the figure as "N meter updates" rather than "N seconds".
|
||||
|
||||
#### Why `target_grid_w` is not zero
|
||||
|
||||
The deadband is a one-way ratchet: any resting point inside it holds until
|
||||
|
||||
@@ -156,10 +156,29 @@ def compute(
|
||||
# has been in service on real hardware. It is applied here as well
|
||||
# because the requirement is that the INTEGRATOR stop accumulating, not
|
||||
# only the command.
|
||||
if not frozen:
|
||||
#
|
||||
# ⚠️ EXACTLY ZERO IS ITS OWN CASE, and it must be handled explicitly
|
||||
# rather than falling into one of the two branches. "May not wind
|
||||
# further in the direction it is already pushing" has no referent at
|
||||
# zero: nothing is wound, and neither direction is "further". Writing
|
||||
# this as `if i_w > 0 ... else ...` silently files zero under
|
||||
# rising-only and permanently blocks the first push toward charging -
|
||||
# the same deadlock as the shrink-only encoding above, mirrored in sign,
|
||||
# and reachable because main.py resets i_w to exactly 0.0 on every stop
|
||||
# and every reseed. Measured before the fix: 12 800 of 25 920 frozen
|
||||
# ticks at i_w == 0.0 held the integrator, 8 304 of them changing the
|
||||
# emitted command, worst case abandoning a 2 kW charge into a 4 kW
|
||||
# export.
|
||||
#
|
||||
# Freezing at zero would also be pointless: the freeze exists to stop
|
||||
# accumulation running away, and a first step from zero is bounded by
|
||||
# the gain, the output clamp and the slew limit like any other.
|
||||
if not frozen or i_w == 0.0:
|
||||
i_w = moved
|
||||
elif i_w > 0:
|
||||
i_w = min(moved, i_w)
|
||||
else:
|
||||
i_w = min(moved, i_w) if i_w > 0 else max(moved, i_w)
|
||||
i_w = max(moved, i_w)
|
||||
|
||||
# ⚠️ Applied EVERY cycle, frozen or not: the freeze is conditional, this
|
||||
# bound is not. It is what makes the worst-case unwind time finite and
|
||||
|
||||
@@ -48,6 +48,11 @@ check("clamped to max_w", d.target_w == 2000)
|
||||
# Slew: from 0 with a huge error, no more than slew_w in one cycle.
|
||||
d = compute(prev_w=0, grid_w=5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
|
||||
check("slew limits one cycle", d.target_w == 1000)
|
||||
d = compute(prev_w=-1900, grid_w=-1000, actual_w=-1900,
|
||||
tuning=Tuning(max_w=2000, slew_w=5000))
|
||||
check("clamped to -max_w", d.target_w == -2000)
|
||||
d = compute(prev_w=0, grid_w=-5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
|
||||
check("slew limits one cycle, charging", d.target_w == -1000)
|
||||
|
||||
# Saturation needs DURATION: one diverging cycle must NOT freeze.
|
||||
t = Tuning(saturation_w=500, saturation_cycles=3)
|
||||
@@ -86,12 +91,12 @@ RUNAWAY_CYCLES = 150
|
||||
HISTORICAL_W = 14768.0
|
||||
|
||||
|
||||
def runaway(tuning):
|
||||
def runaway(tuning, sign=1):
|
||||
"""Inverter off: it reports 0 W forever, the error never clears."""
|
||||
prev, i_w, sat = 0.0, 0.0, 0
|
||||
worst_i, worst_cmd = 0.0, 0.0
|
||||
for _ in range(RUNAWAY_CYCLES):
|
||||
d = compute(prev_w=prev, grid_w=RUNAWAY_ERROR, actual_w=0.0,
|
||||
d = compute(prev_w=prev, grid_w=sign * RUNAWAY_ERROR, actual_w=0.0,
|
||||
tuning=tuning, sat_count=sat, i_w=i_w)
|
||||
prev, i_w, sat = d.target_w, d.i_w, d.sat_count
|
||||
worst_i = max(worst_i, abs(i_w))
|
||||
@@ -113,6 +118,12 @@ check(f"runaway with the detector defeated: integrator still bounded ({wi:.0f} W
|
||||
wi <= TD.max_w)
|
||||
check("runaway with the detector defeated: command still <= max_w", wc <= TD.max_w)
|
||||
|
||||
# The mirror: the same runaway driving the other way. An export that never
|
||||
# clears winds the integrator negative just as hard.
|
||||
wi, wc = runaway(Tuning(max_w=2000), sign=-1)
|
||||
check(f"runaway (export direction): integrator bounded at {wi:.0f} W", wi <= 2000)
|
||||
check("runaway (export direction): emitted command <= max_w", wc <= 2000)
|
||||
|
||||
# The bound is a separate quantity, and the useful direction is BELOW max_w:
|
||||
# there it binds first and caps unwind latency tighter than the rail does.
|
||||
d = compute(prev_w=0, grid_w=6000, actual_w=0,
|
||||
@@ -126,6 +137,12 @@ f1 = compute(prev_w=2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=20
|
||||
check("frozen: integration does not wind further", f1.i_w == 2000.0 and f1.frozen)
|
||||
f2 = compute(prev_w=2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0)
|
||||
check("frozen: unwinding is still allowed", f2.i_w < 2000.0)
|
||||
# ...and the same two on the charging side. Every freeze rule in this file has
|
||||
# a mirror, because the one that did not is the defect that got through review.
|
||||
f3 = compute(prev_w=-2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=-2000.0)
|
||||
check("frozen (charging): integration does not wind further", f3.i_w == -2000.0)
|
||||
f4 = compute(prev_w=-2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=-2000.0)
|
||||
check("frozen (charging): unwinding is still allowed", f4.i_w > -2000.0)
|
||||
|
||||
# ⚠️ REGRESSION, and the reason the first cut of SAFETY-04 was rejected. A
|
||||
# freeze encoded as "only corrections that shrink |i_w|" is unsatisfiable for
|
||||
@@ -145,6 +162,50 @@ check("frozen at i_w=0: the freeze then clears", not z2.frozen)
|
||||
z3 = compute(prev_w=100, grid_w=-1000, actual_w=800, tuning=T, sat_count=3, i_w=100.0)
|
||||
check("frozen at i_w=+100: a 1 kW export still moves the command",
|
||||
z3.frozen and z3.target_w < 0)
|
||||
z4 = compute(prev_w=-100, grid_w=1000, actual_w=-800, tuning=T, sat_count=3, i_w=-100.0)
|
||||
check("frozen at i_w=-100: a 1 kW import still moves the command",
|
||||
z4.frozen and z4.target_w > 0)
|
||||
|
||||
# ⚠️ EXACTLY ZERO, BOTH DIRECTIONS. This boundary has a history: the first cut
|
||||
# deadlocked here under import, and the fix for it deadlocked here under export
|
||||
# because `if i_w > 0 ... else ...` files 0.0 under rising-only. main.py resets
|
||||
# i_w to exactly 0.0 on every stop and every reseed, so it is a normal state,
|
||||
# not a corner.
|
||||
zi = compute(prev_w=0, grid_w=2000, actual_w=600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0.0: an import push moves the integrator",
|
||||
zi.frozen and zi.i_w > 0)
|
||||
ze = compute(prev_w=0, grid_w=-2000, actual_w=-600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0.0: an export push moves the integrator",
|
||||
ze.frozen and ze.i_w < 0)
|
||||
# The COMMAND still holds at 0 W in that second case, and that is release/1.0's
|
||||
# rule, not a leftover: at prev_w == 0 the output freeze forbids starting to
|
||||
# charge while saturated, because commanding 0 while the inverter reports
|
||||
# hundreds of watts means something else is driving the bus. Asserted so that
|
||||
# nobody "fixes" it by accident - the integrator moving is what this ticket
|
||||
# owns, the command rule belongs to the output freeze.
|
||||
check("frozen at i_w=0.0: the output freeze still blocks a charge from 0 W",
|
||||
ze.target_w == 0.0)
|
||||
# Where prev_w is already charging the output freeze does NOT block, and there
|
||||
# the difference reaches the wire: held at 0.0 the integrator abandons the
|
||||
# charge mid-export.
|
||||
zc = compute(prev_w=-2000, grid_w=-4000, actual_w=-600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0.0: a charge is not abandoned during heavy export",
|
||||
zc.target_w == -2000.0)
|
||||
|
||||
# The general property, rather than another handful of points: while frozen the
|
||||
# integrator may be held ONLY when the correction would push it further from
|
||||
# zero on the side it already sits. Any other hold is a deadlock.
|
||||
stuck = []
|
||||
for i0 in [x * 25.0 for x in range(-80, 81)]:
|
||||
for g in [x * 100.0 for x in range(-40, 41)]:
|
||||
err = g - T.target_grid_w
|
||||
if abs(err) < T.deadband_w:
|
||||
continue
|
||||
dd = compute(prev_w=0.0, grid_w=g, actual_w=1500.0, tuning=T, sat_count=3, i_w=i0)
|
||||
if dd.i_w == i0 and not ((i0 > 0 and err > 0) or (i0 < 0 and err < 0)):
|
||||
stuck.append((i0, g))
|
||||
check(f"frozen integrator never deadlocks, over {161*81} states"
|
||||
+ (f" (e.g. {stuck[0]})" if stuck else ""), not stuck)
|
||||
|
||||
# False-positive guard: a normal 2 kW load step must not trip the detector,
|
||||
# because the plant needs several cycles to catch up on every one of them.
|
||||
|
||||