Merge release/1.0 (0.15.0 + SAFETY-90) into maint-10-local-start-hour
Conflicts: main.py's maintenance import (base added CHARGE, HOLD; branch added site_zone) - both kept. DOCS maintenance table: base's longer drain-rate row kept, start hour row at 19 / local. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -85,6 +85,15 @@ configuration:
|
||||
battery_modes_enabled:
|
||||
name: "Hardware · Battery modes"
|
||||
description: "Give each battery an on and off switch and a mode, set on the Batteries screen."
|
||||
pv_forecast_entity:
|
||||
name: "Hardware · Solar forecast, today (kWh)"
|
||||
description: "Optional. A forecast sensor with today's remaining solar energy, such as Forecast.Solar or Solcast. A battery then buys only what the sun will not give."
|
||||
pv_forecast_tomorrow_entity:
|
||||
name: "Hardware · Solar forecast, tomorrow (kWh)"
|
||||
description: "Optional. The same forecast for tomorrow. It helps plan a cheap hour before midnight."
|
||||
solar_trust_pct:
|
||||
name: "Hardware · Trust in the forecast (%)"
|
||||
description: "Forecasts are often too sunny. At 70 % the add-on plans with 7 of every 10 kWh forecast."
|
||||
pv_entity:
|
||||
name: "Hardware · Solar production entity (W)"
|
||||
description: "Optional. Your solar inverter's power sensor, positive while producing. The add-on records it and does not use it for control."
|
||||
|
||||
@@ -66,6 +66,15 @@ configuration:
|
||||
battery_modes_enabled:
|
||||
name: "Hardware · Batterijmodi"
|
||||
description: "Geef elke batterij een aan- en uitschakelaar en een modus, in te stellen op het scherm Batterijen."
|
||||
pv_forecast_entity:
|
||||
name: "Hardware · Zonneprognose, vandaag (kWh)"
|
||||
description: "Optioneel. Een prognosesensor met de zonne-energie die vandaag nog komt, zoals Forecast.Solar of Solcast. Een batterij koopt dan alleen wat de zon niet geeft."
|
||||
pv_forecast_tomorrow_entity:
|
||||
name: "Hardware · Zonneprognose, morgen (kWh)"
|
||||
description: "Optioneel. Dezelfde prognose voor morgen. Ze helpt een goedkoop uur voor middernacht te plannen."
|
||||
solar_trust_pct:
|
||||
name: "Hardware · Vertrouwen in de prognose (%)"
|
||||
description: "Prognoses zijn vaak te zonnig. Bij 70 % plant de add-on met 7 van elke 10 kWh uit de prognose."
|
||||
pv_entity:
|
||||
name: "Hardware · Entiteit zonneproductie (W)"
|
||||
description: "Optioneel. De vermogenssensor van uw zonne-omvormer, positief tijdens productie. De add-on houdt ze bij en regelt er niet mee."
|
||||
|
||||