SAFETY-73: a battery that refuses, per inverter, with two or more
checks / unit (pull_request) Successful in 10m1s
infra-pin / fresh (pull_request) Successful in 1s

SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R).
A unit that gives < 100 W for 12 cycles in one direction while asked
> 200 W, or trips its stale-reading gate on a ~0 W reading, gets a
P_SAFETY `refused` unit limit closing that direction, so the allocator
hands its share to the others within their own limits. Probe: a +-200 W
pin every 15 min, one unit at a time, only while the site asks 200 W that
way. All units refusing: the site law holds 0 W. Exits reseed the site
target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above
the configured cut-out; SAFETY-42/43 no longer report a refusing unit.
N=1 unchanged.

test_refusal_units.py: cases a/b/c on flat and jitter registers against
the old behaviour, probes, recovery, exits; mutations U1-U13 all red.
TEST-19 no-fault campaign: 0 engagements in 5280 runs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-09-28 00:13:26 +02:00
co-authored by Claude Opus 5.5
parent 652097abde
commit 016ed5a5a3
10 changed files with 867 additions and 40 deletions
+8 -4
View File
@@ -149,7 +149,7 @@ check("...and `source` is still the first positional argument, which is what "
Claim.limit("device", P_SAFETY, -1, 1).source == "device")
print()
print("ARB-03 2. the split: eleven sources, each classified where it is BUILT")
print("ARB-03 2. the split: twelve sources, each classified where it is BUILT")
# The classification is graded against what each claim is ABOUT, restated here
# so that the table in arbiter.py and the expectation in a test are not the same
# sentence read twice. test_peakguard.py part 10f pins this set against main.py's
@@ -189,16 +189,20 @@ UNIT_SOURCES = {
"is added, `peak_soc_floor` is not consulted, the SITE target "
"is untouched, and main.py does not file it at all at a "
"roster of one",
# SAFETY-73.
"refused": "THIS battery's own reading gave nothing against THIS unit's "
"own standing command, so that direction is closed on THIS "
"unit and its share goes to the others. Filed at N>1 only",
}
for _src, _why in sorted(SITE_SOURCES.items()):
print(f" site {_src:<11} {_why}")
for _src, _why in sorted(UNIT_SOURCES.items()):
print(f" unit {_src:<11} {_why}")
check("all ELEVEN claim sources are classified, and only those eleven",
check("all TWELVE claim sources are classified, and only those twelve",
set(CLAIM_SCOPE) == set(SITE_SOURCES) | set(UNIT_SOURCES))
check("the six that are about the GRID CONNECTION are site claims",
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE} == set(SITE_SOURCES))
check("the five that are about a PACK, a DEVICE or one write are per-inverter",
check("the six that are about a PACK, a DEVICE or one write are per-inverter",
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT} == set(UNIT_SOURCES))
check("a source nobody classified cannot be routed at all - actuator_for() "
"raises rather than defaulting to the site, because defaulting to the "
@@ -216,7 +220,7 @@ check("with one inverter every source routes to the site, per-inverter ones "
all(actuator_for(s, "inverter-a", ONE) == ACTUATOR_SITE for s in CLAIM_SCOPE))
check("...and with none configured at all, likewise",
all(actuator_for(s, "inverter-a", ()) == ACTUATOR_SITE for s in CLAIM_SCOPE))
check("with TWO the identity breaks and the split becomes real: the five "
check("with TWO the identity breaks and the split becomes real: the six "
"per-inverter sources route to the unit this controller drives, the six "
"site sources stay on the grid connection",
{s: actuator_for(s, "inverter-a", TWO) for s in CLAIM_SCOPE}