SAFETY-73: a battery that refuses, per inverter, with two or more
checks / unit (pull_request) Successful in 10m1s
infra-pin / fresh (pull_request) Successful in 1s

SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R).
A unit that gives < 100 W for 12 cycles in one direction while asked
> 200 W, or trips its stale-reading gate on a ~0 W reading, gets a
P_SAFETY `refused` unit limit closing that direction, so the allocator
hands its share to the others within their own limits. Probe: a +-200 W
pin every 15 min, one unit at a time, only while the site asks 200 W that
way. All units refusing: the site law holds 0 W. Exits reseed the site
target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above
the configured cut-out; SAFETY-42/43 no longer report a refusing unit.
N=1 unchanged.

test_refusal_units.py: cases a/b/c on flat and jitter registers against
the old behaviour, probes, recovery, exits; mutations U1-U13 all red.
TEST-19 no-fault campaign: 0 engagements in 5280 runs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-09-28 00:13:26 +02:00
co-authored by Claude Opus 5.5
parent 652097abde
commit 016ed5a5a3
10 changed files with 867 additions and 40 deletions
+6
View File
@@ -226,6 +226,12 @@ CLAIM_SCOPE = {
# reaches the allocator, so a unit-scoped claim is the shape that sentence
# asks for rather than an evasion of it.
"pack": SCOPE_UNIT,
# main.py: `Claim.limit("refused", P_SAFETY, ...)` and, during a probe,
# `Claim.set("refused", P_SAFETY, +-PROBE_W)`. SAFETY-73: THIS battery gives
# nothing in one direction, measured on THIS unit's own reading. A hard unit
# limit that always intersects, so the share goes to the siblings. Filed at
# N>1 only; at N=1 SAFETY-52's law in compute() does the same job.
"refused": SCOPE_UNIT,
# main.py: `Claim.set("maintenance", P_MAINTENANCE, ...)` when the cycle owns
# the setpoint, and `Claim.limit("maintenance", P_MAINT_SHAPE, hi=...)` when
# it only shapes. §12's monthly recalibration is a PACK procedure - drain
+17
View File
@@ -317,6 +317,16 @@ class Inverter:
tripped=bool(data.get(self.key("delivery_tripped"), False)),
reason=str(data.get(self.key("delivery_reason"), "") or ""))
# SAFETY-73. The direction this unit's battery refuses (+1 give, -1
# take, 0 none), when that refusal or its last probe started, the
# current probe's start, and the cycles of evidence so far. Memory
# only, like SAFETY-52's: stop and start end it. Used at N>1 only.
self.refused = 0
self.refused_at = None
self.probe_from = None
self.ref_count = 0
self.ref_sign = 0
# -- store ---------------------------------------------------------------
def key(self, name: str) -> str:
"""This unit's namespaced Store key for `name`. See store.unit_key()."""
@@ -411,6 +421,13 @@ class Inverter:
return (messages.row_battery_stuck(self.name) if self.batt_fresh.stale
else "")
def refusal_note(self) -> str:
"""SAFETY-73's status row while this unit's battery refuses."""
if not self.refused:
return ""
return messages.row_battery_refuses(self.name, self.refused,
self.probe_from is not None)
def link_note(self, now: datetime) -> str:
"""One line for the status page. Empty when there is nothing to say.
+191 -7
View File
@@ -28,6 +28,7 @@ import contextlib
import functools
import json
import logging
import math
import signal
import time
from datetime import datetime, timedelta, timezone
@@ -234,6 +235,11 @@ def pack_energy_of(inv):
inv.capacity_kwh, inv.max_w)
def _refused_interval(sign: int) -> tuple:
"""SAFETY-73: the (lo, hi) a refusing unit may be asked: 0 W that way."""
return (-math.inf, 0.0) if sign > 0 else (0.0, math.inf)
def why_key(winner: str, claims) -> str:
"""The key of `messages.WHY_WINNER` for a resolution's winner.
@@ -1121,6 +1127,19 @@ class Controller:
"""
t = self.tuning
standing = inv.standing_w()
if len(self.inverters) > 1:
# SAFETY-73: at N>1 the same trip refuses THIS unit only.
if ((self.auto or self.shadow) and not inv.refused
and inv.ref_count >= t.saturation_cycles
and inv.batt_fresh.held is not None
and abs(inv.batt_fresh.held) < _ctl.REFUSED_BELOW_W
and abs(standing) > _ctl.PROBE_W):
self._now_mono = now_mono
self._unit_refusal_start(
inv, 1 if standing > 0 else -1,
f"stale reading {inv.batt_fresh.held:+.0f} W while asked "
f"{standing:+.0f} W")
return
if (len(self.inverters) == 1 and (self.auto or self.shadow)
and not self.batt_refused
and self.sat_count >= t.saturation_cycles
@@ -1132,6 +1151,111 @@ class Controller:
f"stale reading {inv.batt_fresh.held:+.0f} W "
f"while asked {standing:+.0f} W")
# --- SAFETY-73: the same refusal, per inverter, at N>1 -------------------
# SAFETY-52's decisions applied to one unit of several: a unit that gives
# < REFUSED_BELOW_W for SETTLE_CYCLES while asked > PROBE_W is closed in
# that direction by a P_SAFETY unit limit, so the allocator hands its share
# to the others; it is probed at PROBE_W every PROBE_EVERY_S, one unit at a
# time. The ask is PROBE_W, not `saturation_w`: a unit's share is often
# small (a 400 W night load split two ways) and SAFETY-43 would otherwise
# name the empty battery as not delivering. DECISIONS/SAFETY-73.
def _unit_refusal_start(self, inv, sign: int, evidence: str) -> None:
inv.refused, inv.refused_at = sign, self._now_mono
inv.probe_from, inv.ref_count = None, 0
self.log_event(f"BATTERY REFUSES {inv.name}: {evidence}",
hint=messages.hint("unit_refuses", unit=inv.name))
_LOG.info("%s: the battery refuses power, so it is asked 0 W and the "
"other inverters take over: BATTERY_REFUSES.", inv.name)
_LOG.debug("Evidence for %s: BATTERY_REFUSES: %s.", inv.name, evidence)
if (inv.soc is not None and inv.bms_soc_floor is not None
and float(inv.soc) > float(inv.bms_soc_floor)):
# Owner decision 3: a refusal above the configured cut-out level
# may mean that level is set wrong. One line, no safety stop.
_LOG.warning("%s refuses power above its battery cut-out level, "
"check its cut-out level: REFUSES_ABOVE_CUT_OUT.",
inv.name)
_LOG.debug("Evidence for %s: REFUSES_ABOVE_CUT_OUT: battery level "
"%.0f %%, cut-out level %.0f %%.", inv.name,
float(inv.soc), float(inv.bms_soc_floor))
def _unit_refusal_end(self, inv, why: str) -> None:
if not inv.refused:
return
inv.refused, inv.refused_at, inv.probe_from = 0, None, None
inv.ref_count = 0
self.log_event(f"BATTERY REFUSES ENDED {inv.name}: {why}",
hint=messages.hint("unit_gives", unit=inv.name))
_LOG.info("%s: the battery refusal ends, it is asked for power again: "
"%s.", inv.name, why)
# The site target may stand above what was placed (the refused share
# was unmet). Restart it from the watts on the wire, or the reopened
# unit is handed the parked remainder at once (phase A: -1059 W).
placed = float(sum(i.standing_w() for i in self.inverters))
self.target = self.i_w = placed
self.sat_count = 0
def _unit_probe(self, inv) -> bool:
"""True while `inv` may try PROBE_W. One unit probes at a time."""
now = self._now_mono
if not inv.refused or inv.refused_at is None or now is None:
return False
if inv.probe_from is not None:
if now - inv.probe_from < _ctl.PROBE_S:
return True
inv.probe_from, inv.refused_at = None, now
return False
if now - inv.refused_at < _ctl.PROBE_EVERY_S or any(
i.probe_from is not None for i in self.inverters):
return False
inv.probe_from = now
return True
def _unit_refusals(self) -> None:
"""Engage and end each unit's refusal from its own reading."""
for inv in self.inverters:
b = inv.batt
if inv.refused:
if b is not None and inv.refused * b >= _ctl.PROBE_ANSWER_W:
self._unit_refusal_end(
inv, "the probe was answered"
if inv.probe_from is not None
else "the battery gives power")
continue
# The other direction: the battery takes PROBE_ANSWER_W or more
# the other way (charge at the floor) for SETTLE_CYCLES. Counted
# on its own reading, so one cycle of the loop overshooting
# through zero does not hand it its share back.
inv.ref_count = (inv.ref_count + 1 if b is not None and
-inv.refused * b >= _ctl.PROBE_ANSWER_W else 0)
if inv.ref_count >= _ctl.SETTLE_CYCLES:
self._unit_refusal_end(
inv, "the battery takes power the other way")
continue
if b is None:
continue # a gap keeps the count: the gate's trip seeds
standing = inv.standing_w()
sign = 1 if standing > 0 else -1
# One direction throughout: a command that swaps sign every cycle
# (a flapping load) reads ~0 through the plant's own lag, and that
# is a battery following, not refusing (TEST-19 flapping family).
if abs(standing) > _ctl.PROBE_W and abs(b) < _ctl.REFUSED_BELOW_W:
inv.ref_count = (min(inv.ref_count + 1, _ctl.SETTLE_CYCLES)
if sign == inv.ref_sign else 1)
else:
inv.ref_count = 0
inv.ref_sign = sign
if inv.ref_count >= _ctl.SETTLE_CYCLES:
self._unit_refusal_start(
inv, sign,
f"asked {standing:+.0f} W, the battery gave {b:+.0f} W "
f"for {_ctl.SETTLE_CYCLES} cycles")
def _site_refused(self):
"""Owner decision 4: every unit refuses the same way, so the site law
holds 0 W (SAFETY-52's, in compute()). Otherwise None, the old law."""
signs = {inv.refused for inv in self.inverters}
return signs.pop() if len(signs) == 1 and 0 not in signs else None
def log_event(self, msg: str, hint: str | None = None) -> None:
"""`msg` goes on the action log, the add-on's own technical record.
`hint` is `messages.hint()`'s plain words for the same event, and is
@@ -2516,7 +2640,8 @@ class Controller:
now = datetime.now(timezone.utc)
return [n for n in
[x for inv in self.inverters
for x in (inv.link_note(now), inv.stale_note())]
for x in (inv.link_note(now), inv.stale_note(),
inv.refusal_note())]
if n]
async def cycle(self) -> None:
@@ -2810,7 +2935,13 @@ class Controller:
# what part 6 grades instead is that WIDENING the window
# changes the answer.
live=inv.is_live(now)[0],
parked=inv.sign_wd.tripped,
# SAFETY-73: a refusing unit is asked 0 W on purpose, and
# one asked under PROBE_W that gives under 100 W is a
# refusal too small to call (its sibling covers the meter).
parked=inv.sign_wd.tripped or bool(inv.refused) or (
n_units > 1 and inv.batt is not None
and abs(float(standing[inv.name])) <= _ctl.PROBE_W
and abs(float(inv.batt)) < _ctl.REFUSED_BELOW_W),
# ⚠️ THIS UNIT'S OWN CUT-OUT. Not the shipped 10 %, and not
# the site's `peak_soc_floor` either - that one bounds a
# money-saving discharge only, and grading a pack against it
@@ -3422,6 +3553,16 @@ class Controller:
self._refusal_auto = bool(self.auto)
self._refusal_end("control started" if self.auto
else "control stopped")
for inv in (self.inverters if len(self.inverters) > 1 else ()):
self._unit_refusal_end(inv, "control started" if self.auto
else "control stopped")
# SAFETY-73: each unit's own refusal, engaged and ended on its own
# reading, before the loop reads `self.target` (an end reseeds it).
_probing = {}
if len(self.inverters) > 1 and self.inputs_ok:
self._unit_refusals()
_probing = {inv.name: self._unit_probe(inv)
for inv in self.inverters if inv.refused}
if (self.auto or self.shadow) and self.inputs_ok:
# ⚠️ prev is the ARBITER's last output, not the loop's own last
# wish. If something outranked the loop, that is what the hardware
@@ -3446,6 +3587,8 @@ class Controller:
if self.loop_w is not None and self.target != self.loop_w:
self._refusal_end("another writer")
probe = self._refusal_probe()
if len(self.inverters) > 1:
probe = any(_probing.values())
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
# The anti-windup test inside compute() is
# `abs(prev_w - actual_w) > saturation_w`, and `prev_w` is the SITE
@@ -3476,7 +3619,10 @@ class Controller:
i_w=self.i_w,
# SAFETY-52 at one inverter only: with several, OPT-09's pack
# limit already closes an empty battery's discharge end.
refused=self.batt_refused if len(self.inverters) == 1 else None,
# SAFETY-73: at N>1 the site law holds 0 W only while every
# unit refuses the same way. Otherwise None, the old law.
refused=self.batt_refused if len(self.inverters) == 1
else self._site_refused(),
probe=probe,
)
if decision.frozen and self.sat_count < self.tuning.saturation_cycles:
@@ -3486,7 +3632,8 @@ class Controller:
self.sat_count = decision.sat_count
self.i_w = decision.i_w
self.loop_w = decision.target_w
self._refusal_update(decision, loop_prev, site_batt, probe)
if len(self.inverters) == 1:
self._refusal_update(decision, loop_prev, site_batt, probe)
# --- TEL-10 ------------------------------------------------------
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
# THE CARD IS. `self.i_w` is carried between cycles and published
@@ -3585,8 +3732,44 @@ class Controller:
# ability to DELIVER rests on this argument - a weight cannot stop a
# unit being commanded and cannot move a failing unit's load to its
# sibling. The `pack` claim filed above is the half that constrains.
resolution = resolve(claims, units=self.units, live=self.live_units(),
weights=self.pack_weights, tick=self.alloc_tick)
# --- SAFETY-73: each refusing unit's own P_SAFETY claim ---------------
# A hard unit limit that always intersects (OPT-11's P_MODE layer sits
# inside it): closed in the refused direction, so the allocator hands
# the share to the others within their own limits. During its probe it
# is a pin at PROBE_W and the others carry the rest.
for inv in self.inverters:
if not inv.refused:
continue
if _probing.get(inv.name):
claims.append(Claim.set("refused", P_SAFETY,
inv.refused * _ctl.PROBE_W,
_ctl.PROBING,
actuator=self.actuator_of("refused",
inv)))
else:
claims.append(Claim.limit("refused", P_SAFETY,
*_refused_interval(inv.refused),
_ctl.REFUSED,
actuator=self.actuator_of("refused",
inv)))
_live = self.live_units()
while True:
resolution = resolve(claims, units=self.units, live=_live,
weights=self.pack_weights, tick=self.alloc_tick)
# SAFETY-73: a probe pin stands only while the resolved site target
# asks at least PROBE_W its way. Below that a sibling would carry
# the opposite direction (circulation), so the pin goes back to the
# closed limit and the split is resolved once more.
_void = [k for k, c in enumerate(claims)
if c.source == "refused" and c.kind == "set"
and c.value * resolution.target_w < _ctl.PROBE_W ** 2]
if not _void:
break
for k in _void:
claims[k] = Claim.limit(
"refused", P_SAFETY,
*_refused_interval(1 if claims[k].value > 0 else -1),
_ctl.REFUSED, actuator=claims[k].actuator)
self.allocation = resolution.allocation
# --- THE TWO REFUSALS, AND THEY ARE NOT THE SAME REFUSAL --------------
# Both do the same thing - REPLACE the resolution with a 0 W failsafe
@@ -5114,7 +5297,8 @@ class Controller:
_now = datetime.now(timezone.utc)
for inv in self.inverters:
for note, red in ((inv.link_note(_now), not inv.is_live(_now)[0]),
(inv.stale_note(), False)):
(inv.stale_note(), False),
(inv.refusal_note(), False)):
if note:
out.append({"ok": False, "warn": not red, "text": note})
+19
View File
@@ -786,6 +786,14 @@ def row_battery_stuck(unit) -> str:
f"for now")
def row_battery_refuses(unit, sign, probing) -> str:
"""SAFETY-73. One inverter's battery refuses, the others take its share."""
way = "give" if sign > 0 else "take"
if probing:
return f"{unit}: testing if the battery will {way} power again"
return f"{unit}: the battery refuses to {way} power, the others take over"
# The top of the page: why the battery does what it does (the "Why" line).
WHY_WINNER = {
"loop": "Keeping the grid near zero",
@@ -805,6 +813,8 @@ WHY_WINNER = {
# SAFETY-52: the loop's two words for a battery that gives nothing.
"battery refuses": "The battery refuses to give power",
"battery probe": "Testing if the battery gives power again",
# SAFETY-73: a refusing inverter's own claim, closed or probing.
"refused": "A battery refuses power, the others take over",
}
WHY_LIMIT = {
"peak(quarter peak)": "the peak limit",
@@ -815,6 +825,7 @@ WHY_LIMIT = {
"pack": "the battery level",
"reserve": "the battery reserve",
"maintenance": "battery maintenance",
"refused": "a battery that refuses power",
}
@@ -857,6 +868,8 @@ HINTS = {
"battery_back": "{unit}: battery power reading is used again",
"battery_refuses": "The battery refuses to give power, the add-on asks 0 W",
"battery_gives": "The battery refusal ended, control asks for power again",
"unit_refuses": "{unit}: the battery refuses power, the others take over",
"unit_gives": "{unit}: the battery refusal ended, it is asked for power again",
"bad_value": "The add-on made an invalid power value, inverters set to 0 W",
"write_blocked": "{unit}: a power request was blocked, it is set to 0 W",
"all_blocked": "A power request was blocked, inverters set to 0 W",
@@ -1027,6 +1040,12 @@ def status_samples() -> list:
("row_peak_guard_on", AMBER, row_peak_guard_on(1200, 2500,
shadow=True)),
("row_battery_stuck", AMBER, row_battery_stuck("inverter-b")),
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", 1,
False)),
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", -1,
False)),
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", 1,
True)),
("row_circulating_check", GREEN, row_circulating_check(0, 0, 60)),
]