Block a user
UX-13 P0: layout table, page<->options derivation, warning tier, entity list
UX-13 P0: layout table, page<->options derivation, warning tier, entity list
Fixes pushed in badea3c for findings 1–5 of comment 1860:
- With
_region_encodeset to "own", a storedprice_taxes_profileis kept. New check: "'own' keeps a stored levies table when the…
UX-13 P0: layout table, page<->options derivation, warning tier, entity list
Review of UX-13 P0 (head 15627c3)
Verified, no finding
tools/ux13_validator_calls.py compareagainst agit archiveof 652097a, run in the CI image: 261 calls, 158 refused, **0…
UX-13 P0: layout table, page<->options derivation, warning tier, entity list
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
Merged as 652097a (ls-remote verified) with head pinned at 3c0f2b9. PR CI green: checks/unit and infra-pin/fresh. Post-merge infra-pin / fresh (push) green. No pin bump needed.
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
Review fixes pushed: 3c0f2b9 (on 1d33265)
- D1 fixed.
control.REFUSED_BELOW_W = PROBE_ANSWER_W(100 W) is the engage threshold incompute()and in_refusal_from_stale(). Part 5b: a…
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
Review of 1d33265 (SAFETY-52): two defects to fix, the rest checks out
D1. False engagement on a battery that gives some power (defect). The engage clause treats "near 0" as `
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
TEST-23 verification at
TEST-23 verification at 1f97c76 (the control code is identical at the head 1d33265, which only fixes a flaky check in test_price.py). Run 2026-09-27, 16:44 to 17:36 CEST.
Setup -…
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min