Merged as 451729c (parents 340c7ee, 1c607a9), pinned head_commit_id 1c607a9. checks / unit (pull_request) succeeded on 1c607a9 (run 1201, 00:09 -> 00:42, a real run); infra-pin / fresh…
Fixes pushed: 1c607a9 (ls-remote release-0.16.0 = 1c607a961a58). CHANGELOG only, 5 lines:
- SAFETY-103: "can swing by about 800 W for about 5 s".
- SAFETY-99: "can still back off near the…
Review round 1 (REL-0.16.0) on 756b50d.
Checked and fine:
- Diff is only
config.yaml(version 0.15.0 -> 0.16.0) and a new## 0.16.0CHANGELOG section; heading matches. - Minor bump is…
SAFETY-95 re-review (head 4707d37): approved
I re-ran every mutant on purged copies of 4707d37 (test_safety95/93/96/78 + test_modes, control green). M1-M12 are all killed. R1-R9 are all…
F2: fixed with a test in 4707d37. The clause stays.
The test calls _charge_track() directly. A is draining, and its drain SET is crossed by SAFETY-91's pin-as-floor (maintenance LIMIT…
F3: fixed in 4707d37.
_charge_track() now uses (inv.refused or 0) > 0, as _held_back() does. A battery that will not take still drains.
New check: "a refusal ends a drain only if A will…
F1: fixed in 4707d37.
New check in test_safety95.py, section 1: "⭐ stale link, N=3, 4000 W: a dropped draining battery is this rule's, not the link-drop reseed's". It requires the grid…