glenn schrooyenandClaude Opus 5.5 bdec66e97a SAFETY-95: a maintenance drain that ends hands back smoothly (N>=2)
When a battery's drain ended (done, Off, timeout, abort, stale link,
refusal), its drain floor stayed in the site target and landed on the
others: B 0 -> +1600 W in one cycle at a 1200 W house, exporting; under a
solar surplus B gave into the export.

Now, on that cycle, the loop starts from what the others stood at plus the
battery's new command, raised to the house's own point when the house needs
more (never above last cycle's start). While the battery settles, the loop
counts the batteries at its start instead of chasing the drain's tail on
the meter. Then one slew step a cycle. N=1 is unchanged.

test_safety95.py; DECISIONS/SAFETY-95-drain-end.md; one DOCS line.
test_modes.py: opt11 n2_maint re-pinned on purpose (its drain ends by a
refusal at 1655 s; B now stays at the house's 1420 W instead of 2500 W).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>