SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
  own 100 W answer, not below saturation_w: a battery derated to 100-499 W
  was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
  or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
  reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
  DECISIONS record carries the traced cause of the replay's extra trips.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 18:11:42 +02:00

6.3 KiB

SAFETY-52 - a battery that refuses is asked for 0 W

Decided 2026-09-27 by the owner, on the phase A plan (option D3). All four questions answered yes.

The defect

At the BMS cut-out the battery gives ~0 W whatever it is asked. The saturation freeze (control.py, frozen) then holds the request where it stood, and its SAFETY-13 exit cannot fire, because a reading of ~0 against a large ask lies inside the interval a limit can produce. The request stood at +5000 W for 11.87 h on 2026-09-06 and at +1940 W for 3 h 55 m on the bus on 2026-09-19. It moved again only when the grid error changed sign. SAFETY-48's lead cap only changes where i_w parks (one slew step ahead instead of at the rail). When the request moved after the reading went flat, the stale-reading gate won instead and ran SAFETY-59's ~70 s trip cycle.

What was decided

  1. A refused direction is held at 0 W, reason battery refuses. It engages in compute() when the freeze has held SETTLE_CYCLES and the reading is below REFUSED_BELOW_W (100 W, the probe's own answer) against an ask beyond saturation_w. The drop to 0 skips the slew limit (it only removes an ask nobody meets). The direction is carried like sat_count (refused=, Decision.refused).
  2. A 200 W probe every 15 minutes, 34 s long (PROBE_W, PROBE_EVERY_S, PROBE_S; twice BATT_OBLIGED_S). A reading of at least 100 W in the held direction ends the refusal, during a probe or not. 200 W is below freshness.MOVE_W (250 W), so a probe cannot arm the gate. The clock is main.py's now_mono; compute() stays clockless.
  3. A gate trip while the loop is frozen on a ~0 W reading is a refusal for control (Controller._refusal_from_stale). This is what stops the ~70 s cycle. The log keeps SAFETY-56's two-explanation wording.
  4. No SoC in the loop. SAFETY-25 Option A stands. Nothing reads SoC.

Other exits: the loop wants the other direction (charge is accepted at the floor), control stopped or started, another writer on the wire (the arbiter reseed). A gap in the readings keeps the refusal, because the gate's own stop is what seeds it.

One inverter only. At N>1, OPT-09's pack limit already closes an empty battery's discharge end and moves its share. There, a one-unit gate trip must not refuse the site. compute() is passed refused=None there, and that path is release/1.0's law unchanged (the i_w=None equivalence sweep in test_control.py still holds).

Evidence

test_refusal.py drives the real Controller and gate (the 09-06 and 09-19 shapes, recovery with no sign change, the probe cadence, every exit). tools/replay_refusal.py replays the 16-day capture, same model as replay_recorded_loop.py, and should be read for deltas:

plant law gate trips request >1 kW above delivery longest held import / export kWh worst 15-min
fitted old 85 113.3 h 16.57 h 112.0 / 35.2 3434 W
fitted new 130 (133 after review) 11.4 h 0.21 h 112.3 / 35.4 3456 W
offset 0 W old 1010 102.2 h 16.58 h 112.0 / 35.2 3434 W
offset 0 W new 85 6.1 h 0.33 h 111.9 / 35.1 3434 W

Traced in review (#141). The +22 W worst quarter is the old law's worst quarter too. There the old law stands at +2060 W on a pack giving 0 W, and the new law asks 0 W, which the fitted plant answers with its -22 W offset: 22 W charged from the grid. The fit above the floor reads batt = cmd - 28 W, so a real inverter asked 0 W may do the same. Of the 71 new-law trips with no old-law trip within 2 min, 59 come 85-97 s after an answered probe. The offset has lifted the modelled pack just above its floor, the probe is answered, control ramps, the pack empties again mid-ramp, and the gate trips, which re-seeds the hold. The other 12 follow an other-direction exit the same way. On a site this is one STALE_READING ERROR line per answered probe at most, and only on a battery that answers a probe and then cuts out again. Catching the re-cut before the gate needs a faster engage than SETTLE_CYCLES, which accuses a healthy slow battery, so it is left to SAFETY-58/59. After the review changes below the fitted-plant row reads 133 trips (the delivery exit now also catches answers that arrive after the probe window); the other figures are unchanged. Rejected alternatives and their figures are in the phase A plan: bounding the integrator by demand made the worst quarter +541 W worse or cycled the gate 3368 times, and an SoC envelope needs the configured floor to be right and needs SoC.

Review changes (#141)

  • "Gives nothing" is below 100 W, not below 500 W. At saturation_w a battery derated to 100-499 W (cold, a tapering battery) was held at 0 W for ~93 % of the time: 300 W derated gave 86 Wh in 4 h against 1 200 Wh on the old law. The capture has 0.11 h in that band, so the replay does not move.
  • Any delivery ends the hold, not only an answered probe. With meter_poll_s: 1 the 12 cycles last 12 s, less than a healthy battery's reading lag (up to BATT_OBLIGED_S, 17 s). That engaged on a healthy step and held it for 15 min. Now the late reading ends it within seconds (2 s held in test_refusal.py part 5b).
  • N>1 is stated as a limit in DOCS. The pack limit there covers an empty battery only when its cut-out level is configured right.

Not covered

A battery that gives a steady part of the ask (e.g. a 500 W keep-alive) is a genuine limit (SAFETY-13 case a) and still holds its request.

What SAFETY-58 and SAFETY-59 must take into account

  • SAFETY-58 (the first read after a rest trips at once): a probe never arms the gate (200 < 250 W), but the refusal seeding reads the trip. If 58 delays the first verdict, the seed arrives later. The 09-19 shape then needs the compute-side engagement (12 cycles) to win, which it does only while the request stands still. Keep test_refusal.py part 4 green.
  • SAFETY-59 (DOCS says a ~70 s pattern proves a failed register): with this change a refusing battery no longer produces the pattern at one inverter. The DOCS text should say so, and that the battery refuses reason is the discriminator the add-on now has. At N>1 the old pattern can still occur.
  • If either changes MOVE_W, PROBE_W must stay below it. test_refusal.py part 2 checks the inequality.