Inverter A charging at 3 kW while inverter B discharges at 3 kW nets ~0 W at
P1. The site reads idle while both packs are cycled through two round-trip
conversion losses continuously, for no benefit, and the wear is real.
NOTHING EXISTING CAN SEE IT, AND THAT IS STRUCTURAL. Every guard in this
add-on is a consumer of the NET figure at the grid connection: SAFETY-02's
sign watchdog gates on abs(grid_w) > 300 and the gate never opens at a netted
zero; the peak guard and the capacity tariff both bill grid exchange.
Circulating power is precisely the component of per-inverter power that the
sum destroys, so no threshold on any existing detector could reach it.
WHAT ALLOC-01 ALREADY COVERED, AND IS NOT RE-IMPLEMENTED HERE. Its AC 7
shipped the sign-coherence gate (allocator.REFUSE_SIGN, graded by
test_alloc.py part 6): an allocation whose shares carry two signs is REFUSED,
both units named, no shares returned. That is the COMMAND half - the allocator
can no longer command circulating power. This commit is the MEASUREMENT half:
circulation the allocator NEVER COMMANDED.
app/circulation.py the sensor and the trip
main.py site_circulating_w, the evaluation, the claim, the alarm
arbiter.py `circulation` classified SCOPE_SITE, with the argument
store.py a flat, site-level durable latch
mqtt.py sensor.goodwe_circulating_power
config.yaml two options, two schema ranges, CFG-03 discipline
THE SENSOR: sum(|Bi|) - |sum(Bi)|. Zero when the units pull the same way,
2*min(|Ba|,|Bb|) when they oppose. DERIVED FROM MEASURED PER-INVERTER POWER -
Inverter.batt, register 0x0518 - and never from the allocation record. The
cheap version would be simpler and worth nothing: ALLOC-01's gate already
guarantees the record is sign-coherent, so a record-derived sensor reads zero
BY CONSTRUCTION and can only confirm that the allocator agrees with itself,
which is the third failure mode MUTATION.md names. What this catches is a unit
ignoring or lagging its share, a stale share still being executed, a
maintenance or SAFETY-25 pin holding one unit while the loop drives the other,
or HW-01's power stage running its last instruction for 6 h 25 m with the
comms dead and the allocation record impeccable throughout. batt became
per-instance in DEV-02; before that this could not have been written.
VERIFIED BY MAKING ONE UNIT IGNORE ITS SHARE, on the TEST-19 two-master rig:
S = -2500 W shares a = -1250 W b = -1250 W <- record ok, ONE sign, sums
MEASURED A = -1250 W B = +1000 W <- hardware
sensor over the RECORD : 0 W
sensor over MEASURED power : 2000 W -> trips at 190 s
and the card's own scenario, A -3000 W against B +3000 W at zero house load:
the meter reads +0 W, the sensor reads 6000 W, and the shipped SignWatchdog's
predicate is FALSE on 30 of 30 cycles.
WHAT "ACTED ON" MEANS - decided, and recorded in DECISIONS/. The trip files
Claim.set("circulation", P_SAFETY, 0.0) on the SITE actuator: every inverter
to 0 W, latched. HW-01 established that commanding a wedged inverter achieves
nothing, so the remedy is not aimed at it. A circulating loop needs TWO
participants and one of them is THIS CONTROLLER, faithfully driving the
listening sibling into the one that stopped listening. Stopping (1) halves the
loop, which needs no cooperation from the wedged unit, and (2) - the more
important half - makes the residue VISIBLE at the meter instead of cancelled
at it, where every ordinary guard can finally see it. What it cannot do is
stop the wedged unit; the notification says so and names the isolator as the
last actuator. SITE-scoped because the quantity is defined over the roster and
is identically zero for any one unit - there is no fact of the matter about
which of two opposing inverters is the offender, so filing it per-unit would
invent an attribution and could park the only unit still listening.
THE WINDOW IS FROM THE RIG, NOT A ROUND NUMBER (AC 3). 924 closed-loop runs in
which NOTHING is faulty, over both families of legitimate opposition (7
reversals x 5 write staggers; 7 flap periods x 4 amplitudes), swept across the
whole range the schema accepts for gain and slew_w. Worst CONTINUOUS
legitimate opposition by threshold: 505.0 s at 100 W, 40.0 s at 250 W, 10.0 s
at 300 W, 5.0 s at 400 W and above. The knee is 400 W and it is the schema
floor - below it, ordinary operation holds the sensor over the line for
minutes and no window inside the 900 s billing quarter could tell that from a
fault. circulation_w 700 is 1.75x the knee, the headroom bought for inverter
B's ramp and lag being PLACEHOLDERS until SPIKE-04 measures them.
circulation_hold_s 75 clears three bounds: 15x the worst legitimate episode,
2.5x the firmware's own LINK_STALE_S veto, 12x inside the quarter. A momentary
opposition while one unit slews through zero is LEGITIMATE - writes are
serialised, so B's number lands up to a cycle after A's - and 0 of the 924
runs trip.
THE ALARM SURVIVES AN HA RESTART (SAFETY-34). persistent_notification is in
memory, which is exactly how the 2026-09-02 outage went unseen for 6 h 25 m
with the detector correct throughout. The latch is persisted to /data as flat
site-level keys and the notification is RE-RAISED on the first cycle after
every start, through the same code path as a fresh trip - two paths would be
two chances for the restart one to rot unnoticed.
AT N=1 NOTHING CHANGES (AC 5). |B| - |B| is 0 for every reading including one
nobody took, no claim is ever filed, the arbitration is byte-identical, and
the status page says n/a rather than claiming to watch something that cannot
happen.
VERIFIED BY BREAKING IT (AC 4). 18 mutations, all RED on named checks, each on
a freshly copied tree with no __pycache__ mounted :ro. M10 - the sensor
rewritten to read self.allocation.shares - is the headline: it takes AC 2 red.
Three mutations are +0 B, the risky delta, and are marked as such. One
equivalent mutant (the max(0.0,...) guard) is ARGUED rather than claimed:
searched over 700 000 rosters without a negative. One genuine SURVIVOR was
found and closed - publish() turning an unknown into a published 0 W, the
sensor's own None rule defeated one layer out. Full ledger in DECISIONS/.
arbiter.CLAIM_SCOPE gains its ninth source, so test_peakguard.py's 10f and 10g
tripwires and test_arbiter.py's scope table went red on the line the append
was written. Updated deliberately, with the argument, as their own comments
require. Full 19-file suite green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
178 lines
8.6 KiB
Python
178 lines
8.6 KiB
Python
"""Optional MQTT discovery, so the controller's state appears as real HA entities.
|
|
|
|
Optional on purpose: the add-on runs headless without a broker and simply
|
|
publishes nothing. Nothing in the control path depends on this - if MQTT breaks,
|
|
the battery keeps being controlled correctly and only the dashboard goes stale.
|
|
That separation is deliberate; observability must never be able to take down
|
|
control.
|
|
"""
|
|
|
|
import json
|
|
import logging
|
|
|
|
try:
|
|
import paho.mqtt.client as mqtt
|
|
except ImportError: # pragma: no cover - container always has it
|
|
mqtt = None
|
|
|
|
_LOG = logging.getLogger("goodwe.mqtt")
|
|
|
|
# ⚠️ The DEVICE name is half of every entity_id. Home Assistant composes
|
|
# entity_id from device name + entity name, so "GoodWe RS485 Controller" plus
|
|
# "GoodWe battery power" yields
|
|
# sensor.goodwe_rs485_controller_goodwe_battery_power. object_id in the
|
|
# discovery payload did NOT override it (tested on HA 2026.8). So the device is
|
|
# named "GoodWe" and the entities are named without repeating it - that is what
|
|
# makes the ids short, predictable, and identical on every install.
|
|
DEVICE = {
|
|
"identifiers": ["goodwe_rs485_controller"],
|
|
"name": "GoodWe",
|
|
"manufacturer": "GoodWe (via RS485 meter emulation)",
|
|
"model": "ES/BP series",
|
|
}
|
|
|
|
# (key, object_id, name, unit, device_class, state_class, icon)
|
|
#
|
|
# ⚠️ object_id is what pins the entity_id. Without it Home Assistant derives the
|
|
# id from the DEVICE name plus the entity name and produces
|
|
# `sensor.goodwe_rs485_controller_goodwe_battery_power` - unpredictable, ugly,
|
|
# and different if anyone renames the device. Dashboards and documentation need
|
|
# these ids to be stable across every install, so they are declared, not derived.
|
|
SENSORS = [
|
|
("setpoint", "goodwe_setpoint", "Setpoint", "W", "power", "measurement", None),
|
|
("grid", "goodwe_grid_power", "Grid power", "W", "power", "measurement", None),
|
|
("battery", "goodwe_battery_power", "Battery power", "W", "power", "measurement", None),
|
|
("soc", "goodwe_battery_soc", "Battery SoC", "%", "battery", "measurement", None),
|
|
# SAFETY-31. `sum(|Bi|) - |sum(Bi)|` over MEASURED per-inverter power: the
|
|
# power going round between the inverters, which the grid sensor above
|
|
# CANNOT SHOW because it nets to zero there. The two are published side by
|
|
# side on purpose - "grid 0 W, circulating 6000 W" is the whole phenomenon
|
|
# in two rows of a dashboard, and no arithmetic on the grid figure alone can
|
|
# ever produce the second one.
|
|
#
|
|
# ⚠️ Published as 0 at the shipped one-inverter roster, not omitted, and
|
|
# that is a deliberate difference from `p1_age` below. An absent entity is
|
|
# right for a watchdog input nothing is feeding; this is a quantity whose
|
|
# value is KNOWN at N=1 - identically zero, for every reading - and a
|
|
# dashboard row reading 0 W is the honest report of it.
|
|
("circulation", "goodwe_circulating_power", "Circulating power", "W", "power", "measurement", "mdi:sync-alert"),
|
|
("phase", "goodwe_maintenance_phase", "Maintenance phase", None, None, None, "mdi:battery-sync"),
|
|
("status", "goodwe_controller_status", "Controller status", None, None, None, "mdi:heart-pulse"),
|
|
# ⚠️ THE LIVE ENTITY IS `sensor.goodwe_p1_sample_age`, NOT what this
|
|
# object_id spells. An earlier version of this comment said the id "must be
|
|
# exactly sensor.p1_sample_age_s" - that name has never existed on any HA,
|
|
# and believing it is how a safety layer gets disarmed by someone tidying up.
|
|
#
|
|
# On HA 2026.8 `object_id` in a discovery payload does NOT determine the
|
|
# entity_id. HA composes it from the device name plus the entity name:
|
|
# "GoodWe RS485 Controller" + "P1 sample age" -> sensor.goodwe_p1_sample_age.
|
|
# Verified against the live system 2026-08-26; the firmware subscribes to
|
|
# that composed name (goodwe-master-stage4-failsafe.yaml, homeassistant
|
|
# sensor p1_age_s), and its own comment records that sensor.p1_sample_age_s
|
|
# never existed.
|
|
#
|
|
# So: do NOT "fix" the firmware to match the object_id below, and do not
|
|
# rename the device or this entity's friendly name - either changes the
|
|
# composed id and silently disarms the ingest guard, because has_state()
|
|
# simply stays false forever and nothing reports it. The firmware calls this
|
|
# out as the failure that "FAILS SILENTLY AND LOOKS CORRECT".
|
|
#
|
|
# The value: seconds since the newest accepted P1 telegram, republished
|
|
# every second so a meter frozen at a constant value still shows a climbing
|
|
# age - the false-trip this entity exists to remove.
|
|
#
|
|
# ⚠️ Separately, and not fixed here: the firmware's ingest guard tests this
|
|
# sensor's VALUE rather than its arrival, so a dead publisher freezes the
|
|
# number and reads permanently fresh. Filed as TEL-06.
|
|
("p1_age", "p1_sample_age_s", "P1 sample age", "s", "duration", "measurement", None),
|
|
]
|
|
|
|
BASE = "goodwe_ctl"
|
|
AVAILABILITY = f"{BASE}/availability"
|
|
|
|
|
|
class MqttPublisher:
|
|
def __init__(self, host, port, username=None, password=None, omit=()):
|
|
# `omit` drops sensor keys from discovery entirely. ⚠️ Announcing a
|
|
# sensor that nothing will ever publish to is not harmless here:
|
|
# p1_sample_age_s is a watchdog input, and an entity that exists but is
|
|
# never fed is a worse signal than one that does not exist at all.
|
|
self.omit = set(omit)
|
|
self.enabled = mqtt is not None and bool(host)
|
|
self.client = None
|
|
if not self.enabled:
|
|
_LOG.info("MQTT not configured - status entities will not be published")
|
|
return
|
|
# paho-mqtt 2.x requires a callback API version; 1.x has no such
|
|
# argument and Alpine ships 1.x. Support both rather than pinning, so
|
|
# the container can use the distro package instead of compiling.
|
|
try:
|
|
self.client = mqtt.Client(mqtt.CallbackAPIVersion.VERSION2,
|
|
client_id="goodwe_rs485_controller")
|
|
except AttributeError:
|
|
self.client = mqtt.Client(client_id="goodwe_rs485_controller")
|
|
if username:
|
|
self.client.username_pw_set(username, password or "")
|
|
self.client.will_set(AVAILABILITY, "offline", retain=True)
|
|
# ⚠️ Announce from on_connect, never straight after connect(). paho
|
|
# processes the CONNACK on its network thread, so a publish issued
|
|
# immediately after connect() is made while still disconnected - and
|
|
# paho DROPS QoS-0 publishes when disconnected, silently. The result is
|
|
# an add-on that logs "MQTT connected" and creates no entities at all.
|
|
# As a bonus, this also re-announces after every reconnect.
|
|
self.client.on_connect = lambda *_args, **_kw: self._announce()
|
|
try:
|
|
self.client.connect(host, int(port), keepalive=60)
|
|
self.client.loop_start()
|
|
_LOG.info("MQTT connected to %s:%s", host, port)
|
|
except OSError as err:
|
|
_LOG.warning("MQTT connect failed (%s) - continuing without it", err)
|
|
self.enabled = False
|
|
|
|
def _announce(self) -> None:
|
|
for key, object_id, name, unit, dev_class, state_class, icon in SENSORS:
|
|
if key in self.omit:
|
|
continue
|
|
cfg = {
|
|
"name": name,
|
|
"object_id": object_id,
|
|
"unique_id": f"{BASE}_{key}",
|
|
"state_topic": f"{BASE}/{key}",
|
|
"availability_topic": AVAILABILITY,
|
|
"device": DEVICE,
|
|
}
|
|
if unit:
|
|
cfg["unit_of_measurement"] = unit
|
|
if dev_class:
|
|
cfg["device_class"] = dev_class
|
|
if state_class:
|
|
cfg["state_class"] = state_class
|
|
if icon:
|
|
cfg["icon"] = icon
|
|
self.client.publish(
|
|
f"homeassistant/sensor/{BASE}_{key}/config",
|
|
json.dumps(cfg), retain=True,
|
|
)
|
|
self.client.publish(AVAILABILITY, "online", retain=True)
|
|
|
|
def publish(self, values: dict) -> None:
|
|
if not self.enabled or self.client is None:
|
|
return
|
|
try:
|
|
for key, value in values.items():
|
|
if value is None:
|
|
continue
|
|
self.client.publish(f"{BASE}/{key}", str(value))
|
|
except OSError as err: # pragma: no cover
|
|
_LOG.debug("MQTT publish failed: %s", err)
|
|
|
|
def close(self) -> None:
|
|
if not self.enabled or self.client is None:
|
|
return
|
|
try:
|
|
self.client.publish(AVAILABILITY, "offline", retain=True)
|
|
self.client.loop_stop()
|
|
self.client.disconnect()
|
|
except OSError: # pragma: no cover
|
|
pass
|