SAFETY-128: control does not act on late Home Assistant readings
Readings that Home Assistant delivers late but still changing passed
every staleness gate, so the loop corrected again each cycle an error
its last command had already fixed (10 s late: the give run swung and
exported to -1.9 kW), and the peak guard pushed to the inverter limit
on the same late figures (OPT-34 F-2).

app/lateness.py fits how long after a power request the meter shows
it. Over 8 s the readings are late: a request the battery reading has
not answered holds the loop (it may not lead the reading by more than
100 W) and caps the peak guard at what stands; unanswered for 23 s it
holds, then 0 W after stale_input_s. An amber row and one log line per
episode say so. With readings on time nothing changes (digests equal).

DECISIONS/SAFETY-128-late-readings.md; test_safety128.py.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-01 23:45:03 +01:00

475 lines
21 KiB
Python

"""SAFETY-07 - the quarter-peak projection guard: one arbiter `lo` limit at
`P_PEAK` from tariff.py's measured month peak. Pure: no I/O, clock or state.
Why a limit, the floor's derivation, blindness, the SoC reserve and the
options: DECISIONS/SAFETY-07-peak-guard.md."""
from dataclasses import dataclass, replace
from . import messages
from .arbiter import ACTUATOR_SITE, P_PEAK, Claim
from .control import peak_at_risk
from .tariff import QUARTER_S
# Why the projection may not be graded; the status page and log say which.
BLIND_NO_BLOCK = "no open 15-minute period, the meter has given no reading yet"
BLIND_COVERAGE = "meter gap"
BLIND_FROZEN = "the meter is answering without changing"
# Where the ceiling came from. Only an OBSERVED reading may relax it.
CEILING_CAP = "peak_cap_w"
CEILING_MONTH_PEAK = "this month's peak"
# SAFETY-24. Why a forced discharge may not be sized.
FLOOR_SOC_UNREADABLE = ("the battery level was not read this cycle, and "
"unread is not full")
# The words are "the peak reserve", not "the SoC floor": `peak_soc_floor`
# bounds this guard only (SAFETY-25).
FLOOR_AT_SOC_FLOOR = "the battery level is at or below the peak reserve"
SOURCE = "peak"
# Mirror of config.yaml's peak options, pinned to the file by
# test_peakguard.py. Not a read: `decide()` takes them as arguments.
PEAK_OPTION_DEFAULTS = {
# Percent a forced discharge may not go below. 20 is derived from the
# reference pack, 300 Ah at 51.2 V with DoD 90 - 13.8 kWh usable (a test
# pins this wording). See DECISIONS/SAFETY-07-peak-guard.md.
"peak_soc_floor": 20,
# The pack's own cut-out in percent; rule 8 of validate.py refuses a
# `peak_soc_floor` at or below it.
"bms_soc_floor": 10,
# SAFETY-79. Watts the guard aims under `peak_cap_w`.
"peak_margin_w": 50,
}
# SAFETY-79. Range of `peak_margin_w` in config.yaml; test_peakguard.py pins it.
PEAK_MARGIN_RANGE_W = (0, 500)
@dataclass(frozen=True)
class PeakDecision:
"""What the guard concluded this cycle. No `floor_w_or(default)`: turning "not
measured" into a number is the defect `PeakReading` removes."""
engaged: bool
floor_w: float | None # the `lo` the claim carries; None = no claim
ceiling_w: float
ceiling_from: str
blind: str | None = None
projected_w: float | None = None
excess_w: float = 0.0
wanted_w: float | None = None # the floor before `achievable_w` clamped it
target_w: float | None = None # SAFETY-79: what the guard aims at
saturated: bool = False
# SAFETY-24: a forced discharge was wanted and the peak reserve refused it;
# excludes `saturated`. SAFETY-87: at N>=2 the others may be asked up to
# `able_w`.
floor_limited: bool = False
soc: float | None = None
soc_floor: float | None = None
soc_floor_reason: str | None = None
reason: str = ""
# SAFETY-87, N>=2: batteries at or under their reserve, and what the others
# can give.
held: tuple = ()
able_w: float | None = None
# SAFETY-126: power is wanted but the quarter still ends within
# ALARM_MISS_W of the aim with the batteries at 0 W (`misses_aim()`). Set
# by main.py.
within_aim: bool = False
def explain(self) -> str:
"""Idle: the status row's plain words (UX-08). Engaged: `reason`, the
technical record with every figure, for the log and the action log."""
if self.floor_limited:
return self.reason
if not self.engaged:
if self.projected_w is None:
return messages.row_peak_guard_quiet()
return messages.row_peak_guard_idle(
self.projected_w, self.ceiling_w,
month_peak=self.ceiling_from == CEILING_MONTH_PEAK)
return self.reason
def blind_kind(blind: str) -> str:
"""Which of the three kinds of blindness, as a key of
`messages.BLIND_WORDS`, for the status row."""
if blind == BLIND_FROZEN:
return "frozen"
if blind == BLIND_NO_BLOCK:
return "no_block"
return "gap"
def quarter_ceiling_w(cap_w, reading) -> tuple[float, str]:
"""The average this quarter may not exceed, and where it came from.
Only an OBSERVED reading raises it; a failed read keeps the cap (stricter)."""
cap = float(cap_w)
if (reading is not None and getattr(reading, "is_observed", False)
and reading.peak_w is not None and float(reading.peak_w) > cap):
return float(reading.peak_w), CEILING_MONTH_PEAK
return cap, CEILING_CAP
def quarter_target_w(cap_w, margin_w, reading) -> float:
"""SAFETY-79. The average the guard AIMS at: `margin_w` under
`quarter_ceiling_w()`. Reports and the bill keep the real limit (`ceiling_w`)."""
return quarter_ceiling_w(cap_w, reading)[0] - float(margin_w)
def excess_w(projection, ceiling_w) -> float:
"""Watts that must come off the meter now to land the quarter on the ceiling:
`900 * (projected - ceiling) / remaining`; 0.0 when `remaining <= 0`."""
remaining = QUARTER_S - float(projection.elapsed_s)
if remaining <= 0.0:
return 0.0
return QUARTER_S * (float(projection.projected_w) - float(ceiling_w)) / remaining
def uncovered_s(projection) -> float:
"""Seconds of the open block the meter did not cover (`covered_frac` of `elapsed_s`)."""
return max(0.0, float(projection.elapsed_s)
* (1.0 - float(projection.covered_frac)))
def blindness(projection, max_hold_s, frozen: bool) -> str | None:
"""Why this projection may not be graded, or None. Checked first: a fresh
averager's all-zero `Projection` sits under every ceiling."""
if frozen:
return BLIND_FROZEN
if projection.block_start is None:
return BLIND_NO_BLOCK
gap = uncovered_s(projection)
if max_hold_s is not None and gap > float(max_hold_s):
return (f"{BLIND_COVERAGE}, {gap:.0f} s of this 15-minute period not "
f"covered, past the {float(max_hold_s):.0f} s a reading is "
f"held")
return None
# SAFETY-90. Uncounted seconds below this are float noise, never a gap.
GAP_TOL_S = 1e-3
def gap_w(ceiling_w, *seen_w) -> float:
"""SAFETY-90: the watts a meter gap is counted at. The highest of the
limit and `seen_w`, the import with the batteries at 0 W (grid + their
discharge) just before and just after the gap; None entries are skipped.
DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
return max([float(ceiling_w)] + [float(w) for w in seen_w if w is not None])
def fill_gaps(projection, *, tail_s, max_hold_s, unseen_s, gap_w, unseen_w,
held_ws=0.0):
"""SAFETY-90: `projection` with the meter-gap seconds the averager did not
count filled at `gap_w` (those before the first reading, `unseen_s`, at
`unseen_w`), plus `held_ws`. Returns `(projection, gap s, unseen s)`.
`tail_s`: up to `max_hold_s` of the held reading is left as before; past
that nothing is filled. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
if projection.block_start is None or max_hold_s is None:
return projection, 0.0, 0.0
wall = float(projection.elapsed_s)
tail = min(max(0.0, float(tail_s)), wall)
if tail > float(max_hold_s):
return projection, 0.0, 0.0
covered = wall - uncovered_s(projection)
missing = wall - covered - tail
if missing <= GAP_TOL_S:
missing = 0.0
if held_ws <= 0.0:
return projection, 0.0, 0.0
unseen = min(missing, max(0.0, float(unseen_s)))
gap = missing - unseen
add_ws = gap * float(gap_w) + unseen * float(unseen_w) + float(held_ws)
done = covered + missing
return (replace(
projection,
projected_w=float(projection.projected_w) + add_ws / QUARTER_S,
elapsed_w=((float(projection.elapsed_w) * covered + add_ws) / done
if done > 0.0 else float(projection.elapsed_w)),
covered_frac=(done / wall if wall > 0.0
else float(projection.covered_frac))), gap, unseen)
def discharge_permitted(soc, soc_floor) -> str | None:
"""SAFETY-24. May the guard size a forced discharge? None if so, else the reason.
`None` for `soc` or `soc_floor` is NOT permission, and neither has a default.
`<=`: a pack exactly on the floor has spent what the guard may spend."""
if soc is None:
return FLOOR_SOC_UNREADABLE
if soc_floor is None:
return ("no peak guard SoC floor is configured, so there is nothing to "
"bound a forced discharge with")
if float(soc) <= float(soc_floor):
return FLOOR_AT_SOC_FLOOR
return None
@dataclass(frozen=True)
class Pack:
"""SAFETY-32. One pack's numbers for the floor question.
`bms_floor` is its own cut-out percent; None when the roster states none."""
name: str
soc: float | None
bms_floor: float | None
def pack_floor_pct(pack, soc_floor):
"""The percent THIS pack may not be spent below, or None if unknown:
`max(site EMS floor, its own cut-out)`. An unstated cut-out is None, not 0
(`discharge_permitted()` reads None as no permission). The reduction is
written out because it must not depend on validate.py rule 8."""
if soc_floor is None or pack.bms_floor is None:
return None
return max(float(soc_floor), float(pack.bms_floor))
def pack_permissions(packs, soc_floor) -> list[tuple[str, str | None]]:
"""SAFETY-32. Per pack, in roster order: None if it may be spent, else why not.
Unlike the `min()` over SoC, it keeps which pack and which floor."""
return [(p.name, discharge_permitted(p.soc, pack_floor_pct(p, soc_floor)))
for p in packs]
def binding_soc_floor(packs, soc_floor):
"""The one floor `decide()` grades `pack_floor_soc` against: the MAXIMUM of the
packs' floors, so never more permissive than grading each pack. None if any
floor is unknown. At N=1 it is `soc_floor` (test_peakguard.py part 12)."""
if not packs:
return None if soc_floor is None else float(soc_floor)
floors = [pack_floor_pct(p, soc_floor) for p in packs]
if any(f is None for f in floors):
return None
return max(floors)
def reserve_split(packs, soc_floor) -> tuple[list, tuple]:
"""SAFETY-87: `(packs the guard may spend, names of those it may not)`,
each pack graded on its own floor by `pack_permissions()`."""
perms = pack_permissions(packs, soc_floor)
return ([p for p, (_n, why) in zip(packs, perms) if why is None],
tuple(n for n, why in perms if why is not None))
def place_on_able(decision, held, *, able_w, soc, soc_floor) -> PeakDecision:
"""SAFETY-87: `decision` with the batteries in `held` (at or under their
own reserve) giving nothing for the peak. `able_w`, `soc` and `soc_floor`
describe the others, as `decide()`'s arguments do for the roster. A
floor-limited decision is re-taken on them: they are asked for the need
up to `able_w`, and it stays floor-limited only if that is not enough.
`soc` and `soc_floor` keep the roster's verdict, as `decide()` echoed it.
DECISIONS/SAFETY-87-guard-uses-able-batteries.md."""
held = tuple(held)
if not decision.floor_limited or decision.wanted_w is None \
or discharge_permitted(soc, soc_floor) is not None:
return replace(decision, held=held)
wanted = float(decision.wanted_w)
floor = min(wanted, float(able_w))
head = (f"this 15-minute period heads for {decision.projected_w:.0f} W "
f"against a {decision.ceiling_w:.0f} W limit "
f"({decision.ceiling_from}), aiming at {decision.target_w:.0f} W. "
f"At the peak reserve, so giving nothing for the peak: "
f"{messages.names(held)}. The others are asked for {floor:+.0f} W")
if floor >= wanted:
return replace(decision, floor_limited=False, floor_w=floor,
soc_floor_reason=None, held=held, able_w=float(able_w),
reason=f"PEAK_GUARD: {head}")
return replace(decision, floor_w=floor, held=held, able_w=float(able_w),
reason=(f"PEAK_GUARD_FLOOR_LIMITED: {head}, all they can "
f"give, but {wanted:+.0f} W was needed, so this "
f"period may go over the limit"))
def decide(projection, *, batt_w, cap_w, margin_w, reading, achievable_w, soc,
soc_floor, max_hold_s=None, frozen: bool = False) -> PeakDecision:
"""The whole guard. Pure: no clock, no I/O, no state carried between calls.
`batt_w` measured battery power, positive = discharge; None invents no floor.
`achievable_w` largest discharge the arbiter could grant; the floor is
clamped to it so the claim never produces `lo > hi` (resolves to 0 W).
`soc` percent; None is floor-limited. `soc_floor`, `margin_w`: required."""
ceiling, from_where = quarter_ceiling_w(cap_w, reading)
target = quarter_target_w(cap_w, margin_w, reading)
aim = "" if target == ceiling else f", aiming at {target:.0f} W"
ceil_top = abs(float(achievable_w))
blind = blindness(projection, max_hold_s, frozen)
if blind is not None:
# 0.0: nothing trustworthy to size a floor from; forbid charging, which
# costs no pack energy.
return PeakDecision(
engaged=True, floor_w=0.0, ceiling_w=ceiling, ceiling_from=from_where,
target_w=target, blind=blind, projected_w=None,
reason=(f"PEAK_GUARD_BLIND: {blind}. The battery may not charge "
f"while this 15-minute period cannot be measured, so it "
f"is asked for no charging, floor 0 W"))
projected = float(projection.projected_w)
if batt_w is None:
# main.py's P_SAFETY stop already owns a missing input; file nothing.
return PeakDecision(
engaged=False, floor_w=None, ceiling_w=ceiling,
ceiling_from=from_where, target_w=target, projected_w=projected,
reason="no battery measurement to size a floor from")
if QUARTER_S - float(projection.elapsed_s) <= 0.0:
# A block with no seconds left cannot be influenced (`excess_w` answers
# 0.0).
return PeakDecision(
engaged=False, floor_w=None, ceiling_w=ceiling,
ceiling_from=from_where, target_w=target, projected_w=projected,
reason="the quarter has no seconds left to influence")
ex = excess_w(projection, target)
wanted = float(batt_w) + ex
if wanted <= 0.0:
# The test is on the floor (`batt_w + excess`), not on `excess > 0`:
# excess falls to zero once the battery is removing it, and releasing
# there cycled the guard 17 times in one quarter (2026-08-20).
# DECISIONS/SAFETY-07-peak-guard.md.
return PeakDecision(
engaged=False, floor_w=None, ceiling_w=ceiling,
ceiling_from=from_where, target_w=target, projected_w=projected,
excess_w=ex,
wanted_w=wanted,
reason="the load is under the level this quarter can afford")
# SAFETY-24, only here: `wanted > 0`, so a forced discharge is really asked
# for.
denied = discharge_permitted(soc, soc_floor)
if denied is not None:
# 0.0, never negative: forbids charging only. It bounds the guard, not
# the loop.
return PeakDecision(
engaged=True, floor_w=0.0, ceiling_w=ceiling,
ceiling_from=from_where, target_w=target, projected_w=projected,
excess_w=ex,
wanted_w=wanted, floor_limited=True, soc=soc, soc_floor=soc_floor,
soc_floor_reason=denied,
reason=(
f"PEAK_GUARD_FLOOR_LIMITED: this 15-minute period heads for "
f"{projected:.0f} W against a {ceiling:.0f} W limit "
f"({from_where}){aim}, and {wanted:+.0f} W from the battery "
f"would hold it. But {denied}"
+ ("" if soc is None else f", at {float(soc):.0f} %")
+ ("" if soc is None or soc_floor is None
else f" against {float(soc_floor):.0f} %")
+ ", so no forced discharge and no charging, and this period "
"will go over the limit"))
floor = min(wanted, ceil_top)
saturated = floor < wanted
return PeakDecision(
engaged=True, floor_w=floor, ceiling_w=ceiling, ceiling_from=from_where,
target_w=target, blind=None, projected_w=projected, excess_w=ex,
wanted_w=wanted, saturated=saturated, soc=soc, soc_floor=soc_floor,
reason=(
f"PEAK_GUARD: this 15-minute period heads for {projected:.0f} W "
f"against a {ceiling:.0f} W limit ({from_where}){aim}, with "
f"{QUARTER_S - projection.elapsed_s:.0f} s left, so {ex:.0f} W must "
f"come off the meter. The battery measured {float(batt_w):+.0f} W "
f"and is asked for {floor:+.0f} W"
+ (f", the most the inverters give, but {wanted:+.0f} W was needed"
if saturated else "")))
# SAFETY-81. A quarter must end this many W over the real limit (and for
# ALARM_HOLD_S, so a hob cycling does not count) before "Load too high" fires.
ALARM_MISS_W = 10.0
ALARM_HOLD_S = 10.0
def load_too_high(projection, *, batt_w, ceiling_w, achievable_w) -> bool:
"""SAFETY-81. May "Load too high for battery" fire? Only if, with the battery at
full power, the quarter still ends over the real limit by `ALARM_MISS_W`.
No `decide()` gain; `batt_w` is the lower of two cycles' readings.
DECISIONS/SAFETY-81-load-too-high.md."""
remaining = QUARTER_S - float(projection.elapsed_s)
if batt_w is None or remaining <= 0.0:
return False
rest = float(projection.held_w) + float(batt_w) - float(achievable_w)
done_ws = (QUARTER_S * float(projection.projected_w)
- max(float(projection.held_w), 0.0) * remaining)
ends_w = (done_ws + max(rest, 0.0) * remaining) / QUARTER_S
return ends_w - float(ceiling_w) > ALARM_MISS_W
def misses_aim(projection, *, batt_w, target_w) -> bool:
"""SAFETY-126. With the batteries at 0 W from now on, does the quarter end more
than `ALARM_MISS_W` over the aim?
DECISIONS/SAFETY-126-landing-error-is-not-an-overrun.md."""
return load_too_high(projection, batt_w=batt_w, ceiling_w=target_w,
achievable_w=0.0)
def charge_headroom_w(decision) -> float | None:
"""SAFETY-45. The hardest this SITE may charge without putting the billed
quarter over the ceiling, in W; None when nothing measured it (not unlimited).
It is `wanted_w` read the other way, independent of the battery, so sizing a
trade to it cannot oscillate. 0.0 when blind or holding. A SIZING, NOT A
CLAIM: a negative `lo` would cross the maintenance shaping's negative `hi`
(0 W, battery parked). DECISIONS/SAFETY-45-sizing-the-trade.md section 2b."""
if decision is None:
return None
if decision.blind:
return 0.0
if decision.wanted_w is None:
return None
return max(0.0, -float(decision.wanted_w))
def charge_room_w(decision, projection) -> float | None:
"""SAFETY-125: `charge_headroom_w()` less the unread seconds counted at the
last reading, so a late reading is not room for a grid charge.
DECISIONS/SAFETY-125-grid-charge-under-the-month-peak.md."""
room = charge_headroom_w(decision)
if not room or projection is None or projection.block_start is None:
return room
left = QUARTER_S - float(projection.elapsed_s)
if left <= 0.0:
return room
late_ws = max(0.0, float(projection.held_w)) * uncovered_s(projection)
return max(0.0, room - late_ws / left)
def shaping_suspended(decision, peak_forecast_w, cap_w) -> bool:
"""Must the maintenance charge-only shaping stand down this cycle?
Crossing limits resolve to 0 W, so the rule is suppression, not priority.
Both terms are needed: the forecast entity is empty on a default install,
where the measured guard fires. Dropping either parks the battery in the
billed quarter (test_peakguard.py part 7). The one place this conjunction is
written, public so the test grades the shipped expression: do not inline it.
DECISIONS/SAFETY-07-peak-guard.md."""
if peak_at_risk(peak_forecast_w, float(cap_w)):
return True
return decision is not None and decision.engaged
def cap_floor(decision, cap_w):
"""SAFETY-128: the floor no higher than `cap_w` (the command standing while
the readings have not answered it), or `decision` unchanged when None.
DECISIONS/SAFETY-128-late-readings.md."""
if (cap_w is None or decision is None or decision.floor_w is None
or decision.floor_w <= cap_w):
return decision
return replace(
decision, floor_w=float(cap_w), saturated=False,
reason=decision.reason + f", held at {float(cap_w):+.0f} W until the "
"readings answer the last power request")
def claim(decision: PeakDecision) -> Claim | None:
"""The decision as one arbiter claim (`lo` only, `hi` stays `+inf`), or None."""
if not decision.engaged or decision.floor_w is None:
return None
# Blind, floor-limited and a genuine zero floor all file `lo = 0 W`; each
# gets its own reason. On the SITE actuator: the billed quantity is one per
# site.
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
reason=("blind" if decision.blind
else "SoC floor" if decision.floor_limited
and not decision.floor_w
else "quarter peak"),
actuator=ACTUATOR_SITE)