"""Runnable check for the maintenance state machine. `python3 test_maintenance.py`
Walks a whole cycle in simulated time, which is the test the YAML version never
had - and it is exactly the phase transitions that a real cycle takes ten hours
to exercise once a month.
⚠️ MUTATING THE MODULE THIS FILE GRADES? PURGE `__pycache__` FIRST - or run
`tools/mutation_run.sh`, which does. `python3 -B` alone does NOT save you: it
stops bytecode being WRITTEN, not a stale one being READ, and a size-preserving
edit reverted inside one second is invisible to CPython's staleness test. That
is TEST-15, and it has already turned one live mutation into a false survivor.
Read MUTATION.md before you report a survivor.
"""
import sys
from datetime import datetime, timedelta, timezone
from app.maintenance import CHARGE, DRAIN, HOLD, IDLE, MaintConfig, Maintenance
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
class FakeStore:
"""Same surface as Store, no disk."""
def __init__(self):
self.data = {"phase": IDLE, "phase_started": None,
"last_completed": None, "last_start_attempt": None}
def set(self, k, v):
self.data[k] = v
def set_time(self, k, when):
self.data[k] = when
def get_time(self, k):
return self.data.get(k)
def save(self):
pass
cfg = MaintConfig(enabled=True, interval_days=28, start_hour=10,
discharge_w=2500, charge_w=2500,
soc_floor=11, soc_target=99, hold_min=120)
t0 = datetime(2026, 8, 23, 10, 0, tzinfo=timezone.utc)
print("scheduling")
m = Maintenance(cfg, FakeStore())
check("never run before is due", m.due(t0))
r = m.tick(t0, soc=80)
check("starts at the start hour when due", r.phase == DRAIN and r.owns_setpoint)
check("drain commands the discharge rate", r.setpoint_w == 2500)
m2 = Maintenance(cfg, FakeStore())
r = m2.tick(t0.replace(hour=11), soc=80)
check("does not start outside the start hour", r.phase == IDLE)
m3 = Maintenance(cfg, FakeStore())
m3.store.set_time("last_completed", t0 - timedelta(days=3))
check("not due three days after a cycle", not m3.due(t0))
check("due 29 days after a cycle",
Maintenance(cfg, FakeStore()).due(t0) and
(t0 - (t0 - timedelta(days=29))) >= timedelta(days=28))
print("ownership per phase")
m = Maintenance(cfg, FakeStore())
m.force_start(t0)
r = m.tick(t0, soc=80)
check("drain: maintenance owns the setpoint", r.owns_setpoint and not r.charge_only)
r = m.tick(t0 + timedelta(hours=3), soc=10.5)
check("drain exits at the floor", r.phase == CHARGE)
check("charge: the LOOP owns the setpoint", not r.owns_setpoint and r.charge_only)
r = m.tick(t0 + timedelta(hours=20), soc=99)
check("charge exits at the target", r.phase == HOLD)
check("hold: maintenance owns and commands zero",
r.owns_setpoint and r.setpoint_w == 0.0)
r = m.tick(t0 + timedelta(hours=21), soc=100)
check("hold keeps holding before hold_min", r.phase == HOLD)
r = m.tick(t0 + timedelta(hours=22, minutes=5), soc=100)
check("hold completes after hold_min", r.phase == IDLE)
check("completion is recorded", m.store.get_time("last_completed") is not None)
check("no longer due right after completing", not m.due(t0 + timedelta(hours=22)))
print("failure handling")
m = Maintenance(cfg, FakeStore())
m.force_start(t0)
r = m.tick(t0 + timedelta(hours=13), soc=60)
check("drain aborts on timeout", r.phase == IDLE)
check("abort commands zero", r.setpoint_w == 0.0)
m = Maintenance(cfg, FakeStore())
m.force_start(t0)
r = m.tick(t0 + timedelta(minutes=5), soc=None)
check("no SoC: holds the phase rather than guessing", r.phase == DRAIN)
check("no SoC: still commands the drain rate", r.setpoint_w == 2500)
m = Maintenance(cfg, FakeStore())
m.store.set("phase", "banana")
r = m.tick(t0, soc=50)
check("unknown phase recovers to idle at 0 W", r.phase == IDLE and r.setpoint_w == 0.0)
print("disabled schedule")
m = Maintenance(MaintConfig(enabled=False), FakeStore())
check("disabled never starts", m.tick(t0, soc=80).phase == IDLE)
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
sys.exit(1)