glenn schrooyenandClaude Opus 5 f8e501393f OPT-09: the weights parameter nothing ever passed, and what it cannot do
`allocator.plan()` has taken a `weights` argument since ALLOC-01 and NOTHING
had ever passed one - main.py called `resolve()` without it and the arbiter
defaulted it to 1.0 per unit - so the site target was split 50/50 regardless
of what either pack could do. Two things now feed it, and they are different
kinds of thing:

  * a `pack` UNIT claim at P_SAFETY that CLOSES a unit's envelope at its own
    `bms_soc_floor` or at 100 % - a PERMISSION, obeyed absolutely, so an empty
    pack is not asked to discharge and its share goes to the sibling;
  * SoC-aware weights by ENERGY headroom in kWh - a PREFERENCE, which
    `_fill()`'s last-resort pass will override the moment the sibling saturates.

Measured (test_packshare.py part 8): at a load one pack cannot cover, the
weighted arm and the shipped arm command the IDENTICAL watts into an empty pack
and deliver the IDENTICAL watts. Only the envelope stops the ask, and what it
buys is not delivery - it is a reported `unmet_w` where the record used to read
impeccable. Weights are a comfort choice for STABILITY and NOT for DELIVERY.

Also: an optional per-entry `capacity_kwh` (schema change, all-or-nothing across
the roster, rule 9 refuses a partial one); per-pack arbitrage sizing, with the
sell side's no-op stated rather than hidden; and a 0 W trade refused by name,
because a 0 W arbitrage claim is a park order that outranks the loop.

SAFETY-42 and this card meet at one hazard from opposite sides - OPT-09 stops
the site ASKING a pack whose SoC says it cannot deliver, SAFETY-42 alarms when a
pack that said it could does not - and its end-to-end fixture moved as a result.
Its finding is unchanged and is now stated on the two quantities its rejected
discriminator actually reads.

Not filed at all at a roster of one: at N=1 every source routes to the site, so
the interval would bound the SITE TARGET, and SAFETY-25's decided Option A
stands untouched on the live install.

⚠️ INVERTER B DOES NOT EXIST. Its 4600 W / 20.48 kWh / 10 % are FROM DATASHEET
AND SERIAL, and `sim/plantsim.py`'s INVERTER_B is inverter A copied
(`measured=False`), so every two-inverter figure here is arithmetic or two
copies of A. No hardware was touched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 22:55:20 +02:00

544 lines
31 KiB
Python

"""Runnable check for the precedence arbiter. `python3 test_arbiter.py`
Each assertion is a precedence question someone will eventually ask in the
field: "why did it charge during a peak?", "why did it discharge while the
maintenance cycle was charging?", "what happens if two things disagree?".
⚠️ MUTATING THE MODULE THIS FILE GRADES? PURGE `__pycache__` FIRST - or run
`tools/mutation_run.sh`, which does. `python3 -B` alone does NOT save you: it
stops bytecode being WRITTEN, not a stale one being READ, and a size-preserving
edit reverted inside one second is invisible to CPython's staleness test. That
is TEST-15, and it has already turned one live mutation into a false survivor.
Read MUTATION.md before you report a survivor.
"""
import sys
from math import inf
from app.arbiter import (
ACTUATOR_SITE, CLAIM_SCOPE, P_ARBITRAGE, P_LOOP, P_MAINT_SHAPE,
P_MAINTENANCE, P_PEAK, P_SAFETY, SCOPE_SITE, SCOPE_UNIT, UnitBounds,
Claim, actuator_for, allocate, pre_resolve, resolve, scope_violations,
site_resolve,
)
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def _raises(fn):
"""True if `fn()` raises - a check that something is REFUSED, not defaulted."""
try:
fn()
except Exception:
return True
return False
print("basics")
r = resolve([])
check("no claims at all means 0 W", r.target_w == 0.0 and r.winner == "failsafe")
r = resolve([Claim.set("loop", P_LOOP, 900)])
check("a lone claim is honoured", r.target_w == 900)
r = resolve([Claim.set("loop", P_LOOP, 900),
Claim.set("maintenance", P_MAINTENANCE, 2500)])
check("higher priority set wins", r.target_w == 2500 and r.winner == "maintenance")
print("limits")
r = resolve([Claim.set("loop", P_LOOP, 4000),
Claim.limit("supervised", P_SAFETY, lo=-2000, hi=2000, reason="max_w")])
check("safety limit binds the loop", r.target_w == 2000)
check("and says what bound it", "supervised" in (r.bound_by or ""))
r = resolve([Claim.set("loop", P_LOOP, 4000),
Claim.limit("a", P_SAFETY, hi=3000),
Claim.limit("b", P_SAFETY, hi=1500)])
check("most restrictive limit wins", r.target_w == 1500)
print("the rule that matters: limits only bind claims at or below their priority")
# Maintenance charge phase forbids discharging...
charge_only = Claim.limit("maintenance", P_MAINT_SHAPE, hi=0, reason="charge-only")
r = resolve([Claim.set("loop", P_LOOP, 900), charge_only])
check("charge-only stops the ordinary loop discharging", r.target_w == 0)
# ...but peak shaving outranks it and must be able to discharge anyway.
r = resolve([Claim.set("loop", P_LOOP, 900), charge_only,
Claim.set("peak", P_PEAK, 2500)])
check("peak shaving is NOT bound by charge-only", r.target_w == 2500)
check("peak shaving is the winner", r.winner == "peak")
# Safety limits still bind everything, including peak shaving.
r = resolve([Claim.set("peak", P_PEAK, 9000), charge_only,
Claim.limit("device", P_SAFETY, lo=-5000, hi=5000, reason="rating")])
check("safety limits bind even the highest strategy", r.target_w == 5000)
print("safety stops")
r = resolve([Claim.set("loop", P_LOOP, 900),
Claim.set("safety", P_SAFETY, 0, "inputs missing")])
check("a safety stop beats everything", r.target_w == 0 and r.winner == "safety")
r = resolve([Claim.set("maintenance", P_MAINTENANCE, 2500),
Claim.set("safety", P_SAFETY, 0, "stopped")])
check("safety stop beats maintenance too", r.target_w == 0)
print("contradictions are bugs, not ties")
r = resolve([Claim.set("loop", P_LOOP, 500),
Claim.limit("x", P_SAFETY, lo=1000),
Claim.limit("y", P_SAFETY, hi=200)])
check("impossible limits command 0 W", r.target_w == 0.0)
check("and are flagged, not silently clipped", r.contradiction)
check("explain() says so", "CONTRADICTION" in r.explain())
print("explainability")
r = resolve([Claim.set("loop", P_LOOP, 900), charge_only])
check("explain names winner and binder",
"loop" in r.explain() and "maintenance" in r.explain())
print(f" e.g. {r.explain()!r}")
print("sign handling")
r = resolve([Claim.set("loop", P_LOOP, -3000),
Claim.limit("supervised", P_SAFETY, lo=-1000, hi=1000)])
check("charging is clamped by the low limit", r.target_w == -1000)
r = resolve([Claim.set("loop", P_LOOP, -200), charge_only])
check("charge-only permits charging", r.target_w == -200)
# =============================================================================
# ARB-03: the actuator specs.md declared, and the three stages
# =============================================================================
# ⚠️ EVERY CHECK ABOVE THIS LINE IS UNEDITED, AND THAT IS ITSELF THE FIRST
# ACCEPTANCE CRITERION. Not one of them names an actuator, so every claim they
# build is a SITE claim - which is exactly the state main.py is in at N=1 - and
# they still answer what they answered before the field existed. If a line above
# had to be changed to accommodate `actuator`, stage 2 would not be the shipped
# arbiter and the refactor would not be pure.
print()
print("ARB-03 1. the field, and what its absence means")
lone = Claim.set("loop", P_LOOP, 900)
check("a claim built without naming an actuator carries one anyway",
lone.actuator == ACTUATOR_SITE)
# ⚠️ THE TYPE ITSELF, NOT ONLY THE TWO HELPERS. Measured: with only the helper
# checked, emptying the DATACLASS default survives this suite untouched, because
# `Claim.set()` and `Claim.limit()` pass their own default down and the field's
# never runs. Anything that builds a `Claim(...)` directly - a future strategy,
# a `dataclasses.replace()` - would have got the unspecified actuator that this
# card exists to remove.
check("...and so does one built through the dataclass directly, which is the "
"constructor the two helpers do not cover",
Claim("loop", P_LOOP).actuator == ACTUATOR_SITE)
check("...and it is an explicit SITE, not None and not an empty string. "
"'unspecified' is what the shipped code had, and 'unspecified' is what "
"made every claim implicitly about the one and only actuator",
isinstance(lone.actuator, str) and lone.actuator != ""
and lone.actuator is not None)
check("...and `source` is still the first positional argument, which is what "
"test_peakguard.py part 10f's AST scan reads off main.py to pin the "
"claim-source set. specs.md declares `actuator` first; the tuple position "
"is not the part of that declaration that carries meaning, and moving "
"`source` off zero would blind the tripwire that guards SAFETY-25",
Claim.limit("device", P_SAFETY, -1, 1).source == "device")
print()
print("ARB-03 2. the split: eleven sources, each classified where it is BUILT")
# The classification is graded against what each claim is ABOUT, restated here
# so that the table in arbiter.py and the expectation in a test are not the same
# sentence read twice. test_peakguard.py part 10f pins this set against main.py's
# own AST, so a ninth source cannot arrive without both files noticing.
SITE_SOURCES = {
"loop": "regulates grid_w, the P1 measurement - one meter, one site",
"peak": "the quarter-hour average offtake AT the grid connection",
"arbitrage": "buys and sells at the grid against a day-ahead price",
"safety": "'stopped' is the site's switch, 'inputs missing' is the "
"site's own meter - neither is about a pack",
# SAFETY-31, and it is the entry most easily filed on the wrong side.
"circulation": "sum(|Bi|) - |sum(Bi)| is defined OVER THE ROSTER and is "
"identically zero for any one unit - there is no fact of "
"the matter about which of two opposing inverters is the "
"offender, so there is nothing to file it per-unit on",
# SAFETY-30, and it is the entry most easily confused with `failsafe`
# below, because the same three words describe both.
"sign_site": "the SUM of every standing command against the meter. The "
"offending number is the SITE target, which no single "
"inverter owns - parking one of them would leave the rest "
"pushing the same way with the guard satisfied",
}
UNIT_SOURCES = {
"device": "one inverter's own reported min/max rating",
"supervised": "max_w caps what may be WRITTEN to one setpoint entity",
"failsafe": "per-unit evidence, per-unit remedy: since SAFETY-30 it "
"grades THIS unit's command against THIS unit's OWN "
"measured power (0x0518), so what it learns is about one "
"device. The site-wide half moved to `sign_site`",
"maintenance": "the monthly recalibration is a pack procedure",
# OPT-09, and it is the entry a reader will want to check against
# SAFETY-25's deferred loop-side reserve, because it has the same shape.
"pack": "THIS pack's own state of charge against THIS pack's own "
"`bms_soc_floor` - a fact about one battery in one cupboard, "
"exactly as `device`'s rating is a fact about one box. It is "
"not SAFETY-25's deferred `loop_soc_floor` reserve: no option "
"is added, `peak_soc_floor` is not consulted, the SITE target "
"is untouched, and main.py does not file it at all at a "
"roster of one",
}
for _src, _why in sorted(SITE_SOURCES.items()):
print(f" site {_src:<11} {_why}")
for _src, _why in sorted(UNIT_SOURCES.items()):
print(f" unit {_src:<11} {_why}")
check("all ELEVEN claim sources are classified, and only those eleven",
set(CLAIM_SCOPE) == set(SITE_SOURCES) | set(UNIT_SOURCES))
check("the six that are about the GRID CONNECTION are site claims",
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE} == set(SITE_SOURCES))
check("the five that are about a PACK, a DEVICE or one write are per-inverter",
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT} == set(UNIT_SOURCES))
check("a source nobody classified cannot be routed at all - actuator_for() "
"raises rather than defaulting to the site, because defaulting to the "
"site is the failure this card removes",
_raises(lambda: actuator_for("reserve", "inverter-a", ("inverter-a",))))
print()
print("ARB-03 3. at N=1 the site IS the unit, so nothing moves")
# §6.2's identity: with one inverter the fabricated grid reading and the battery
# setpoint are the same number, so there is one actuator and it is both.
ONE = ("inverter-a",)
TWO = ("inverter-a", "inverter-b")
check("with one inverter every source routes to the site, per-inverter ones "
"included - that is the identity, not the classification being ignored",
all(actuator_for(s, "inverter-a", ONE) == ACTUATOR_SITE for s in CLAIM_SCOPE))
check("...and with none configured at all, likewise",
all(actuator_for(s, "inverter-a", ()) == ACTUATOR_SITE for s in CLAIM_SCOPE))
check("with TWO the identity breaks and the split becomes real: the five "
"per-inverter sources route to the unit this controller drives, the six "
"site sources stay on the grid connection",
{s: actuator_for(s, "inverter-a", TWO) for s in CLAIM_SCOPE}
== {**{s: "inverter-a" for s in UNIT_SOURCES},
**{s: ACTUATOR_SITE for s in SITE_SOURCES}})
print()
print("ARB-03 4. stage 2 IS the shipped arbiter (AC 3)")
# ⚠️ NOT ASSERTED, REPLAYED. Every claim list this file resolves above is run
# through BOTH entry points and every field the shipped code reads off a
# Resolution is compared. `resolve()` at N=1 is `site_resolve()` on the same
# list, so a single edit inside stage 2 would show up in every check above as
# well as here - and one that only affects the wrapper shows up only here.
REPLAY = [
[],
[Claim.set("loop", P_LOOP, 900)],
[Claim.set("loop", P_LOOP, 900), Claim.set("maintenance", P_MAINTENANCE, 2500)],
[Claim.set("loop", P_LOOP, 4000),
Claim.limit("supervised", P_SAFETY, lo=-2000, hi=2000, reason="max_w")],
[Claim.set("loop", P_LOOP, 4000), Claim.limit("a", P_SAFETY, hi=3000),
Claim.limit("b", P_SAFETY, hi=1500)],
[Claim.set("loop", P_LOOP, 900), charge_only],
[Claim.set("loop", P_LOOP, 900), charge_only, Claim.set("peak", P_PEAK, 2500)],
[Claim.set("peak", P_PEAK, 9000), charge_only,
Claim.limit("device", P_SAFETY, lo=-5000, hi=5000, reason="rating")],
[Claim.set("loop", P_LOOP, 900), Claim.set("safety", P_SAFETY, 0, "inputs missing")],
[Claim.set("loop", P_LOOP, 500), Claim.limit("x", P_SAFETY, lo=1000),
Claim.limit("y", P_SAFETY, hi=200)],
[Claim.set("loop", P_LOOP, -3000),
Claim.limit("supervised", P_SAFETY, lo=-1000, hi=1000)],
[Claim.set("loop", P_LOOP, -200), charge_only],
[Claim.set("arbitrage", P_ARBITRAGE, -2000, "buy"),
Claim.limit("peak", P_PEAK, lo=800.0, reason="quarter peak"),
Claim.limit("supervised", P_SAFETY, lo=-2000, hi=2000, reason="max_w")],
]
def _shape(r):
return (r.target_w, r.winner, r.bound_by, r.contradiction,
list(r.considered), r.explain())
_diff = [i for i, cl in enumerate(REPLAY)
if _shape(resolve(cl)) != _shape(site_resolve(cl))]
print(f" replayed {len(REPLAY)} claim lists through both entry points")
check("NOT ONE of them resolves differently - target, winner, binder, "
"contradiction flag, the considered list and the operator line are equal "
"on every one. At N=1 the three stages are the shipped arbiter with "
"bookkeeping either side of it", _diff == [] and len(REPLAY) >= 12)
check("...and stage 3 hands the whole target to the one actuator there is, "
"which is the N=1 identity rather than an allocation",
resolve([Claim.set("loop", P_LOOP, 900)]).shares == {ACTUATOR_SITE: 900.0})
check("...and says it allocated, because at N<=1 there is nothing to divide",
resolve([Claim.set("loop", P_LOOP, 900)]).allocated)
print()
print("ARB-03 5. THE CONTRADICTION THAT CANNOT BE WRITTEN DOWN (AC 4)")
# SAFETY-25 §0a, constructed. A per-inverter reserve says "this pack must not
# discharge" (`hi = 0`); the peak guard says "the site must deliver at least
# 1500 W" (`lo = 1500`). At N=1 those are two bounds on ONE number and they
# genuinely cross - which is today's behaviour, and today's hazard, and is left
# exactly as it is. Filed on TWO actuators they are bounds on two different
# numbers, and there is no expression in which one is the other's counterpart.
SITE_SIDE = [Claim.set("loop", P_LOOP, -1500.0, "grid"),
Claim.limit("peak", P_PEAK, lo=1500.0, reason="quarter peak")]
CROSSED = SITE_SIDE + [Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0,
reason="charge-only")]
SPLIT = SITE_SIDE + [Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0,
reason="charge-only", actuator="inverter-b")]
r_crossed, r_split = resolve(CROSSED), resolve(SPLIT)
print(f" both on one actuator: {r_crossed.explain()}")
print(f" the `hi` on inverter-b: {r_split.explain()} "
f"inverter-b bounds {r_split.unit_bounds['inverter-b'].explain()}")
check("filed on ONE actuator the pair still contradicts and still parks the "
"battery at 0 W in the billed quarter. That is the shipped behaviour and "
"this card does not change it - at N=1 the two really are bounds on one "
"number", r_crossed.contradiction and r_crossed.target_w == 0.0)
check("filed on TWO the site keeps its floor: the unit `hi` is not a term of "
"the site's `lo > hi` test, so there is no contradiction to flag",
not r_split.contradiction and r_split.target_w == 1500.0)
check("...and the constraint is not lost, it is CARRIED - inverter-b's own "
"interval still says 'do not discharge', for the allocator to honour when "
"it divides the 1500 W", r_split.unit_bounds["inverter-b"].hi == 0.0
and r_split.unit_bounds["inverter-b"].hi_src == "maintenance")
check("...and the site target is bit-for-bit what the site claims alone "
"resolve to, so the unit claim contributed NOTHING to it - which is the "
"'cannot be expressed' rather than 'is guarded against'",
_shape(site_resolve(SITE_SIDE))[:4] == _shape(r_split)[:4])
# Swept rather than argued: no per-inverter source, at any bound, on any unit,
# can reach the site's limits.
_SWEEP_N = _SWEEP_BAD = 0
for _src in sorted(UNIT_SOURCES):
for _unit in ("inverter-a", "inverter-b"):
for _lo, _hi in ((0.0, inf), (-inf, 0.0), (2500.0, inf), (-inf, -2500.0),
(900.0, 100.0)):
_r = resolve(SITE_SIDE + [Claim.limit(_src, P_MAINT_SHAPE, lo=_lo,
hi=_hi, actuator=_unit)])
_SWEEP_N += 1
if _r.contradiction or _r.target_w != 1500.0:
_SWEEP_BAD += 1
print(f" swept {_SWEEP_N} (per-inverter source x unit x bound) filings "
f"against a live site floor: {_SWEEP_BAD} disturbed the site target")
check(f"NOT ONE of the {_SWEEP_N} filings contradicts the site floor or moves "
f"the site target - including the last bound of each row, which is a unit "
f"contradicting ITSELF (lo 900 > hi 100). A unit's own impossible pair "
f"parks that unit; it does not park the site",
_SWEEP_BAD == 0 and _SWEEP_N >= 40)
_self_bad = resolve(SITE_SIDE + [Claim.limit("maintenance", P_MAINT_SHAPE,
lo=900.0, hi=100.0,
actuator="inverter-b")])
check("...and that unit says so on its own bounds, so the fault is reported "
"where it was made rather than swallowed",
_self_bad.unit_bounds["inverter-b"].contradiction
and "CONTRADICTION" in _self_bad.unit_bounds["inverter-b"].explain())
print()
print("ARB-03 6. stage 1: one unit's claims, one unit's interval")
mb = pre_resolve([Claim.limit("device", P_SAFETY, -5000, 5000, "rating"),
Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w"),
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only")])
print(f" a unit filing rating, max_w and charge-only: {mb.explain()}")
check("the most restrictive of the unit's own limits is the interval",
mb.lo == -2000 and mb.hi == 0.0 and mb.hi_src == "maintenance"
and mb.lo_src == "supervised")
owned = pre_resolve([Claim.set("maintenance", P_MAINTENANCE, -2500, "charge"),
Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w"),
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only")])
print(f" a unit whose maintenance owns the setpoint: {owned.explain()}")
check("a unit's own winning SET gates its own limits exactly as clause 2 does "
"at the site - the P_MAINT_SHAPE ceiling is not applied to a "
"P_MAINTENANCE drain that outranks it", owned.hi == 2000.0)
check("...and the SET's value travels BESIDE the interval, not inside it. "
"Folding -2500 into [-2500, -2500] would turn 'clamped to max_w' into "
"'contradicts max_w', which is a different answer and a wrong one",
owned.pinned_w == -2500 and owned.pinned_by == "maintenance"
and owned.gate == P_MAINTENANCE and not owned.contradiction)
print()
print("ARB-03 7 / ALLOC-01: the seam, and what now occupies it")
# ⚠️ THIS PART WAS "the seam is a seam, and NOT an allocator" AND IT GRADED THE
# DECLINE. ALLOC-01 filled the seam, so the decline at N>=2 is gone - and the
# checks that graded it are RE-AIMED rather than deleted, because the two halves
# they were really about are both still true and both still worth a line: the
# N<=1 pass-through is byte-identical, and the seam still does not BROADCAST.
check("with no units the whole target goes to the site actuator",
allocate(1500.0, {}) == ({ACTUATOR_SITE: 1500.0}, True))
check("with one unit the share IS the site target - §6.2's N=1 identity, "
"pass-through. ⚠️ A FLOAT, UNROUNDED AND UNCLAMPED: this is the "
"compatibility promise every N=1 replay in this repository depends on, "
"and the general path below does neither of those things",
allocate(1500.0, {"inverter-a": UnitBounds()})
== ({"inverter-a": 1500.0}, True))
check("...and it is byte-identical on a fractional target too, which is where a "
"'tidy this into the general path' refactor would show up: the general "
"path rounds to the 1 W register, the pass-through must not",
allocate(1500.4, {"inverter-a": UnitBounds()})
== ({"inverter-a": 1500.4}, True))
_shares, _ok = allocate(1500.0, {"inverter-a": UnitBounds(),
"inverter-b": UnitBounds()})
print(f" two units, ALLOC-01: shares={_shares} allocated={_ok}")
check("⚠️ AND THE ONE THING THE SEAM MUST NEVER DO, WHICH IS THE WHOLE OF "
"ARCH-01: it does not BROADCAST. Hand the site target to each inverter "
"and each supplies it IN FULL - the gain at the meter becomes N times the "
"per-unit gain, which admin/goodwe's two-master rig measures as a 4000 W "
"peak-to-peak limit cycle at gain 1.0 with not one guard firing. This "
"line went red on ARB-03's decline and it goes red on a broadcast, which "
"is the point: it grades the OUTPUT, not the mechanism",
1500.0 not in _shares.values())
check("...it allocates instead, and the shares SUM to the site target exactly. "
"That is the safety property: sum(s_i) = S is what makes the gain at the "
"meter a convex combination of the per-unit gains for ANY split, so the "
"weights are a comfort choice and a bad split cannot destabilise the site",
_ok is True and sum(_shares.values()) == 1500
and sorted(_shares) == ["inverter-a", "inverter-b"])
check("...and an odd target still sums exactly, which is the half a per-unit "
"round() gets wrong: 1501/2 is 750.5 twice, and two roundings of that are "
"either 1500 or 1502. Largest remainder gives 751 and 750",
sum(allocate(1501.0, {"inverter-a": UnitBounds(),
"inverter-b": UnitBounds()})[0].values()) == 1501)
check("⚠️ AND THE DECLINE IS NOT GONE, IT IS RE-AIMED. It is still correct when "
"no safe split exists at all, and PR #40's reviewer proved that branch was "
"unreachable and untested once already - removing its trigger without "
"giving it a new one would rebuild that hole. Here: every inverter's "
"master stale, so there is no envelope set to allocate into",
allocate(1500.0, {"inverter-a": UnitBounds(),
"inverter-b": UnitBounds()}, live=()) == ({}, False))
# ⚠️ AND `resolve()` HAS TO HONOUR THE ROSTER IT IS GIVEN, WHICH IS NOT THE SAME
# THING AS HAVING A `units` PARAMETER. Left None the roster is DERIVED from the
# claims, and that derivation is right only for a caller that files a claim for
# every unit every cycle. Ignore the argument and derive it always - `if units
# is None:` -> `if True:` - and a unit that filed nothing this cycle simply
# CEASES TO EXIST: the site of two looks like a site of one, the seam passes the
# whole grid target through to the single inverter that spoke, and ARCH-01's
# fault is built with the evidence for it removed. That mutation left this whole
# suite green until this check was written (PR #40 review), so it is graded on
# the one observation that distinguishes the two - a SILENT unit.
_silent = resolve([Claim.set("loop", P_LOOP, 900.0),
Claim.limit("device", P_SAFETY, -2000, 2000, "rating",
actuator="inverter-a")],
units=TWO)
print(f" roster of two, only inverter-a files: bounds="
f"{sorted(_silent.unit_bounds)} allocated={_silent.allocated} "
f"shares={_silent.shares}")
check("resolve() HONOURS the roster it is handed rather than inferring one from "
"who happened to speak. inverter-b filed nothing this cycle and is still "
"a unit: it gets its own interval, and the site is still a site of TWO, "
"so the target is SPLIT across two inverters",
sorted(_silent.unit_bounds) == ["inverter-a", "inverter-b"]
and _silent.shares == {"inverter-a": 450, "inverter-b": 450})
check("...and that is the whole cost of ignoring the argument, stated as the "
"number it would produce: derive the roster from the claims instead and "
"the site is a site of ONE, so the seam passes ALL 900 W through to "
"inverter-a - the silent inverter's absence read as a smaller site, and "
"inverter-a told to do the whole site's work on its own. ⚠️ ALLOC-01 "
"makes this mutation WORSE, not better: before, both answers refused, so "
"only the roster listing distinguished them; now the wrong one produces a "
"plausible number that is twice what inverter-a should be given",
resolve([Claim.set("loop", P_LOOP, 900.0),
Claim.limit("device", P_SAFETY, -2000, 2000, "rating",
actuator="inverter-a")]).shares
== {"inverter-a": 900.0})
check("...and left None the roster IS derived from the claims, which is the "
"documented default every N=1 replay above depends on - so the parameter "
"changes the answer only where the two disagree",
resolve([Claim.set("loop", P_LOOP, 900.0),
Claim.limit("device", P_SAFETY, -2000, 2000, "rating",
actuator="inverter-a")], units=None).allocated is True)
print()
print("ARB-03 8. verified by breaking it: a claim routed to the wrong stage (AC 6)")
# The `peak` floor, misfiled on a unit. It is the site's floor - if it lands on
# one inverter's interval the SITE keeps no floor at all, and the loop is free to
# go on charging through the quarter that sets the month's bill.
mis_peak = SITE_SIDE[:1] + [Claim.limit("peak", P_PEAK, lo=1500.0,
reason="quarter peak",
actuator="inverter-b")]
r_mis = resolve(mis_peak)
print(f" peak floor misfiled on inverter-b: {r_mis.explain()} "
f"scope_errors={r_mis.scope_errors}")
# ⚠️ THE ORDERED PAIR, AND THE CHECK THAT USED TO BE HERE WAS WIDER THAN ITS
# OWN CLAIM. It said `scope_violations` "names the source and the actuator it
# does not belong on" and then asserted `"peak" in r_mis.scope_errors[0]`.
# `arbiter.py:264` builds that sentence as
# `f"{c.source}: a SITE claim filed on unit {c.actuator!r} - …"`; transpose the
# two - zero bytes, no decision changes, SAFETY-38 census B row B12 - and it
# reads "inverter-b: a SITE claim filed on unit 'peak'", naming the misfiled
# claim as the actuator and the actuator as the claim. `"peak" in …` is STILL
# TRUE under that, so the old line graded neither half of what it claimed.
# The operands are read off the CLAIM this test built, not off the message.
_mis_c = mis_peak[-1]
check("PRECONDITION: the misfiled claim's source and actuator are DIFFERENT "
"STRINGS, so a transposition genuinely produces a different sentence",
_mis_c.source != _mis_c.actuator and _mis_c.source == "peak"
and _mis_c.actuator == "inverter-b")
check("the mis-routing is CAUGHT, and scope_violations names the source FIRST "
"and the actuator it does not belong on SECOND - the ORDERED PAIR on the "
"contiguous literal, because a substring test finds either name under a "
"transposition that swaps their roles",
len(r_mis.scope_errors) == 1
and r_mis.scope_errors[0].startswith(
f"{_mis_c.source}: a SITE claim filed on unit {_mis_c.actuator!r}"))
check("...and the TRANSPOSED sentence is not what it says, so the check above "
"discriminates rather than decorates",
f"{_mis_c.actuator}: a SITE claim filed on unit {_mis_c.source!r}"
not in r_mis.scope_errors[0])
check("...and the reason it must be caught, measured rather than argued: with "
"the floor on a unit the SITE has no floor, so the loop charges 1500 W "
"into the quarter the guard was trying to shave",
r_mis.target_w == -1500.0 and resolve(SITE_SIDE).target_w == 1500.0)
check("a UNIT source filed on the site at a site that HAS named units is "
"caught too - that is the direction that produces `lo > hi`",
scope_violations(SITE_SIDE + [
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0),
Claim.limit("device", P_SAFETY, -1, 1, actuator="inverter-b")]) != [])
check("...and at N=1, where every source legitimately routes to the site, the "
"same list is clean. The check grades ROUTING, not tidiness",
scope_violations(SITE_SIDE + [
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0)]) == [])
check("an unclassified ninth source is a violation wherever it is filed",
scope_violations([Claim.limit("reserve", P_LOOP, hi=0.0)]) != [])
check("and the eight, routed by actuator_for() at a two-inverter site, are "
"clean - which is what says the router and the checker agree",
scope_violations(
[Claim.limit(s, P_SAFETY, -1, 1,
actuator=actuator_for(s, "inverter-a", TWO))
for s in CLAIM_SCOPE]) == [])
# --- ALLOC-01: AND NOW SOMETHING HAPPENS ABOUT IT ---------------------------
# ⚠️ ARB-03 LEFT THIS DELIBERATELY INERT - `scope_violations()` logged and did
# not change the resolution, and nothing graded the consequence. ALLOC-01 had to
# decide, and decided the allocator CONSUMES it as a REFUSAL rather than as an
# input. The reasoning is at `allocator.plan()`'s REFUSAL 1 and the short form
# is: the mis-routed claim has already been partitioned by the time stage 3
# runs, so its effect is baked into S or into somebody's interval; "consuming"
# it as an allocation input would mean RE-ROUTING it, which needs a guess about
# which inverter it belonged to that nothing here can make. What is left is that
# S itself may be wrong, and dividing a number that may be wrong is worse than
# not dividing it.
print(f" and stage 3's answer to it: {r_mis.allocation.explain()}")
check("⚠️ the mis-routing is no longer only a log line: stage 3 REFUSES to "
"allocate on a claim list it has been told is mis-routed, so main.py "
"fails toward inaction and shouts instead of dividing a number that may "
"be wrong. That is the same answer clause 3 already gives a contradiction",
r_mis.allocated is False and r_mis.shares == {}
and "mis-routed" in r_mis.allocation.refused)
check("...and it is NOT consumed as an ENVELOPE, which is the tempting reading "
"and the wrong one: a unit-scoped claim that landed on the site names no "
"unit, so promoting it means either guessing one or applying one "
"inverter's rating to a sibling that does not have it. Nothing here is "
"promoted - the refusal carries no shares at all",
r_mis.allocation.plans == () and r_mis.allocation.dropped == ())
check("...and a correctly routed cycle is unaffected, which is what says this "
"grades ROUTING and not the presence of units: the same site claims with "
"the floor where it belongs allocate normally",
resolve(SITE_SIDE, units=TWO).allocated is True)
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
sys.exit(1)
print("all checks passed")