"""Controller methods that build the status page, rows and MQTT output.
Moved unchanged from app/main.py (MAINT-21). DECISIONS/MAIN-orchestration.md."""
import logging
import time
from datetime import datetime, timezone
from . import arbitrage
from . import packmode
from .clamp import is_commandable
from . import dayview, homeview
from . import messages
from .freeze import rail_unreachable, rail_w
from .hass import OUTAGE
from .maintenance import IDLE
from .mqtt import (
announced_units, optional_keys, parse_command, unit_slugs, unit_state_key,
)
from . import peakguard
from . import pv as pv_read
from . import shadow
from .price import brussels
from .validate import FIRMWARE_INGEST_VETO_S
from .rows import arbitrage_row
_LOG = logging.getLogger("goodwe")
class StatusMixin:
async def mqtt_command(self, topic, payload, retained) -> None:
"""OPT-11 P2: one command from a battery's HA switch or mode list,
through handle_action(). A retained command is never applied (the store
already holds the last choice). Never raises: MQTT must not reach
control. (DECISIONS/MAIN-orchestration-archive.md)"""
try:
slug, action, value, why = parse_command(
topic, payload, retained, packmode.MODES)
if why is None:
names = [inv.name for inv in self.inverters]
unit = dict(zip(unit_slugs(names), names)).get(slug)
result = await self.handle_action(action, unit=unit,
value=value)
if not (isinstance(result, dict) and "error" in result):
self.mqtt.publish(self.mode_values())
return
why = result["error"]
else:
why = messages.pack_refused(why)
# Printable only: a topic is sender-chosen, so no log injection.
topic_s = "".join(c if c.isprintable() else "?"
for c in str(topic)[:128])
_LOG.debug("Home Assistant command %s %s refused: %s", topic_s,
repr(payload)[:48], why)
if (topic_s, why) in self._mqtt_refused \
or len(self._mqtt_refused) >= 32:
# Not logged again, but counted: 1, 10, 100... stay visible.
self._mqtt_refused_more += 1
more = self._mqtt_refused_more
if str(more).rstrip("0") == "1":
_LOG.warning("Home Assistant commands still ignored: %d "
"more so far.", more)
return
self._mqtt_refused.add((topic_s, why))
_LOG.warning("Home Assistant command on %s ignored: %s", topic_s,
why)
except Exception: # noqa: BLE001
_LOG.exception("Home Assistant command could not be handled")
@property
def why_words(self) -> str:
"""The page's "Why" line. While control waits for a missing reading
the age is counted when the page asks (UX-10), not frozen at the age
the last cycle saw."""
if self._why_waiting_since is not None:
return messages.why_waiting(max(0.0, (
datetime.now(timezone.utc)
- self._why_waiting_since).total_seconds()))
return self._why_words
@why_words.setter
def why_words(self, text: str) -> None:
self._why_words = text
self._why_waiting_since = None
def publish(self) -> None:
# ⚠️ SITE TOTALS, AND THE KEYS DO NOT MOVE: `battery` stays the SUM and
# `soc` the EMPTIEST pack (their `unique_id`s are on live dashboards);
# per-inverter entities are TEL-07's.
# (DECISIONS/MAIN-orchestration-archive.md)
values = {
"setpoint": self.target,
"grid": self.grid,
"battery": self.site_batt_w,
"soc": self.pack_floor_soc,
"phase": self.maint.phase,
# ⚠️ SAFETY-02's alarm surface, and it is deliberately an existing
# one: "failsafe" is additive to a sensor already on every
# dashboard, and a P_SAFETY stop that did not reach it would be a
# site at 0 W reporting "running".
# (DECISIONS/MAIN-orchestration-archive.md)
"status": ("failsafe" if any(i.sign_wd.tripped
for i in self.inverters)
or (self.site_sign_wd.tripped
and len(self.inverters) > 1)
or self.circ_wd.tripped
# SAFETY-10: "shadow" is its own value and not a flavour
# of "stopped". ⚠️ BELOW `failsafe`: a latch that is up
# is up, and shadow does not clear it.
# (DECISIONS/MAIN-orchestration-archive.md)
else "shadow" if self.shadow
else "running" if self.auto else "stopped"),
# SAFETY-31. ⚠️ MEASURED, not the allocation record - see
# `site_circulating_w`. `publish()` drops None values, so a missing
# per-unit reading leaves the last figure standing rather than
# publishing a zero that would read as health.
# (DECISIONS/MAIN-orchestration-archive.md)
"circulation": (None if self.site_circulating_w is None
else round(self.site_circulating_w)),
# TEL-10. The loop's own three, written from the fields `cycle()`
# recorded and not re-derived (the page and the publisher run on
# their own tasks, and `self.target` has moved on).
# (DECISIONS/MAIN-orchestration-archive.md)
"loop_i": round(self.loop_i_w, 1),
"loop_lead": round(self.loop_i_lead, 1),
"loop_reason": self.loop_reason,
}
# TEL-11. ⚠️ THE KEY IS PRESENT WITH `None` WHEN THERE IS NO READING
# AND ABSENT WHEN THERE IS NO SOURCE: two states
# (`mqtt.ABSENT_AS_UNKNOWN` makes the first an `unknown`, a gap in the
# recorder). TEL-12: still ONE number, the SITE total, None unless
# EVERY entity answered. ⚠️ THE GATE IS `optional_keys()`, THE SAME
# EXPRESSION THE ANNOUNCEMENT USES.
# (DECISIONS/MAIN-orchestration-archive.md)
if "pv" in optional_keys(self.o):
values["pv"] = (None if self.pv_w is None
else round(self.pv_w, 1))
# ⚠️ ONLY when P1 ingestion is running: the ESP32's stale-input
# watchdog subscribes to sensor.goodwe_p1_sample_age and forces layer-1
# failsafe at max_age_s, so with meter_source off a published age would
# climb unbounded and pin every existing install at 0 W within 30 s.
# Publishing nothing leaves the entity non-existent (firmware
# has_state()). (DECISIONS/MAIN-orchestration-archive.md)
if self.p1_enabled:
# Recomputed here, once a second, on purpose - see P1Ingest.
values["p1_age"] = round(self.p1.published_age_s, 1)
# TEL-07. THE PER-UNIT ROWS, AND THE EMPTY LIST IS THE GATE: ⚠️ no `if
# len(self.inverters) > 1` here, deliberately: `announced_units()`
# answers [] at N=1, so what is announced and what is published come
# from one expression. ⚠️ The site rows do not move: `battery` stays
# the SUM and `soc` the EMPTIEST pack (live dashboards use those ids).
# (DECISIONS/MAIN-orchestration-archive.md)
names = announced_units([inv.name for inv in self.inverters])
for inv, slug in zip(self.inverters, unit_slugs(names)):
values[unit_state_key(slug, "setpoint")] = inv.target
values[unit_state_key(slug, "battery")] = inv.batt
values[unit_state_key(slug, "soc")] = inv.soc
values[unit_state_key(slug, "sign_latch")] = (
"tripped" if inv.sign_wd.tripped else "clear")
# OPT-11 P2: each battery's mode and switch; nothing while modes are off.
values.update(self.mode_values())
self.mqtt.publish(values)
# -- UI ------------------------------------------------------------------
def checks(self, when: datetime | None = None) -> list:
"""The status rows. `when` is the reference time for anything billed by
the calendar - today's month when it is None, which is what the live
page means. ⚠️ IT EXISTS SO THE PEAK ROW CAN BE GRADED (TEST-17): a
suite that banks an August quarter went red at the September boundary.
(DECISIONS/MAIN-orchestration-archive.md)"""
o = self.o
out = []
# SAFETY-61. First, so a stalled loop is the headline: the heartbeat is
# sent from this loop, so past layer 1's veto the inverter is at 0 W.
if self.loop_pass_mono is None:
out.append({"ok": True, "warn": False, "id": "controller",
"text": messages.row_controller_starting()})
else:
_pass_age = time.monotonic() - self.loop_pass_mono
if _pass_age > FIRMWARE_INGEST_VETO_S:
out.append({"ok": False, "warn": False, "id": "controller",
"text": messages.row_controller_stalled(
_pass_age, FIRMWARE_INGEST_VETO_S)})
else:
out.append({"ok": True, "warn": False, "id": "controller",
"text": messages.row_controller_ran(_pass_age)})
# SAFETY-112. The headline unless control has stalled: while the
# Supervisor gives 502 (Home Assistant not yet RUNNING) no reading or
# write gets through, and the rows below that need it follow from it.
if OUTAGE.waiting():
out.insert(1 if out[0]["ok"] is False else 0,
{"ok": False, "warn": False, "id": "home_assistant",
"banner": messages.banner_ha_waiting(),
"text": messages.row_ha_waiting()})
if self.p1_enabled:
age = self.p1.published_age_s
if (self.p1.stale and self.p1.age_s() is None
and age <= self.p1.max_age_s):
# UX-10: no reading yet since the start, still inside the
# limit. Amber, not red: it is not a fault yet, but control
# waits for it. Red at 0 s contradicted the limit the row
# prints. (DECISIONS/MAIN-orchestration-archive.md)
out.append({"ok": False, "warn": True, "id": "meter",
"text": messages.row_meter_waiting(
self.p1.max_age_s)})
elif self.p1.stale:
# The last error is on the add-on log's WARNING line (p1.py).
out.append({"ok": False, "warn": False, "id": "meter",
"text": messages.row_meter_stale(
age, self.p1.max_age_s)})
else:
# ⚠️ unchanged_s is REPORTED, never thresholded and never
# folded into the age - see HomeWizardLocalSource.unchanged_s
# for why (at the converged -10 W this controller aims for, a 1
# Wh register needs ~6 minutes to move, so any limit
# false-trips at the exact operating point we target).
# (DECISIONS/MAIN-orchestration-archive.md)
unchanged = getattr(self.p1_source, "unchanged_s", None)
out.append({"ok": True, "warn": False, "id": "meter",
"text": messages.row_meter(
self.p1.net_w, age, self.p1.parse_errors,
unchanged)})
# SAFETY-18. Reported in both states (a detector nobody can see is
# armed is not trusted when it fires). ok=False/warn=False so the
# banner goes red; it changes NOTHING about control (see
# check_meter_frozen()). (DECISIONS/MAIN-orchestration-archive.md)
if self.freeze_wd.active:
# The figures are in `freeze_wd.reason`, on the log and the
# event list (check_meter_frozen()).
out.append({"ok": False, "warn": False, "id": "meter_frozen",
"text": messages.row_meter_frozen()})
elif getattr(self.p1_source, "unchanged_s", None) is None:
# Not "armed". Every transport but homewizard_local is invisible
# to this check, and saying "armed" there would be a lie the
# status page tells on behalf of a guard that cannot run.
out.append({"ok": False, "warn": True, "id": "freeze_check",
"text": messages.row_freeze_off("source")})
elif rail_unreachable(self.site_max_w,
dev_min=self.site_dev_bound("dev_min"),
dev_max=self.site_dev_bound("dev_max")):
# SAFETY-20: the same row as the transport case above (the
# check cannot be evaluated here); only the missing term
# differs. (DECISIONS/MAIN-orchestration-archive.md)
_no_rating = (not self.site_max_w
or not is_commandable(self.site_max_w))
out.append({"ok": False, "warn": True, "id": "freeze_check",
"text": messages.row_freeze_off(
"rating" if _no_rating else "range")})
else:
# ⚠️ SAFETY-20. THE RAIL PRINTED HERE IS THE RAIL THE PREDICATE
# USES, device range included.
# (DECISIONS/MAIN-orchestration-archive.md)
_rail = rail_w(self.site_max_w,
dev_min=self.site_dev_bound("dev_min"),
dev_max=self.site_dev_bound("dev_max"))
# And when the device set that number, SAY SO: the operator
# configured `max_w`. ⚠️ Either bound may be None on its own
# (`hass.limits()` reads min and max independently), so render
# what is there. (DECISIONS/MAIN-orchestration-archive.md)
out.append({"ok": True, "warn": False, "id": "freeze_check",
"text": messages.row_freeze_on(
self.freeze_wd.cfg.hold_s, _rail,
own_limit=_rail < rail_w(self.site_max_w))})
# TARIFF-01. The month's billed peak, and a DIFFERENT row when the
# store could not answer: "no peak yet" is normal on the 1st,
# "unreadable" is a broken instrument.
# (DECISIONS/MAIN-orchestration-archive.md)
_pk = self.peak.peak(when)
if _pk.is_unreadable:
out.append({"ok": False, "warn": True, "id": "month_peak",
"text": messages.row_month_peak_unreadable()})
else:
# §9.1's "warning entity at 80 %", as a status row rather than
# a second entity - see the constructor on not doubling up.
_frac = self.peak.warning_frac(when) or 0.0
_ok = _frac < 0.8
out.append({"ok": _ok, "warn": not _ok, "id": "month_peak",
"text": (messages.row_month_peak_none()
if not _pk.is_observed else
messages.row_month_peak(
_pk.peak_w,
brussels(_pk.quarter_start),
_frac))})
out.append({"ok": True, "warn": False, "id": "periods_measured",
"text": messages.row_periods_measured(
self.peak.recorded)})
# SAFETY-07. Three rows, not one, because "idle" and "cannot see"
# are opposite states and a page that spelled them the same would
# show a green line over a guard that is switched off. `None` is a
# fourth state on purpose: before the first cycle nothing has been
# concluded. (DECISIONS/MAIN-orchestration-archive.md)
_pg = self.peak_guard
if _pg is None:
out.append({"ok": True, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_waiting()})
elif _pg.saturated and not _pg.within_aim:
out.append({"ok": False, "warn": False, "id": "peak_guard",
"runs": True,
"text": messages.row_peak_saturated(_pg.ceiling_w)})
elif _pg.floor_limited and (
not ((_pg.floor_w or 0.0) > 0.0 or _pg.within_aim)
or self._peak_floor_limited):
# SAFETY-24. NOT ok, like saturation (the money is being spent
# and a human is the only actuator left); a separate row
# because the remedy is opposite. ⚠️ SAFETY-25: the scope
# sentence (the floor binds the guard, not the loop) is part of
# the row, which carries its own short `banner`; shortening the
# ROW would weaken AC 3.
# (DECISIONS/MAIN-orchestration-archive.md)
out.append({"ok": False, "warn": False, "id": "peak_guard",
"runs": True,
"banner": messages.banner_peak_reserve(),
"text": messages.row_peak_reserve(
_pg.ceiling_w, soc_unread=_pg.soc is None,
floor_unknown=(_pg.soc is not None
and _pg.soc_floor is None),
packs=(_pg.held if len(self.inverters) > 1
else ()),
others=(_pg.floor_w or 0.0) > 0.0)})
elif _pg.blind:
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_blind(
peakguard.blind_kind(_pg.blind))})
elif self.peak_unmeasured_s > 0.0:
# SAFETY-90: the start of this quarter came before the first
# reading, and the guard counts it as high use.
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_unmeasured()})
elif _pg.engaged:
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_on(
_pg.floor_w or 0.0, _pg.ceiling_w,
shadow=self.shadow)})
elif _pg.projected_w is not None:
# SAFETY-125: "under" only when it is; over the limit at this
# rate, a grid charge is cut back to the quarter's room.
out.append({"ok": True, "warn": False, "id": "peak_guard",
"text": messages.row_peak_guard_idle(
_pg.projected_w, _pg.ceiling_w,
month_peak=(_pg.ceiling_from
== peakguard.CEILING_MONTH_PEAK),
cut=self.room_charge and not self.shadow)})
else:
out.append({"ok": True, "warn": False, "id": "peak_guard",
"text": _pg.explain()})
else:
# ⚠️ OUTSIDE the `p1_enabled` block, and that placement is the
# point: SAFETY-07 is NOT COVERED on the legacy single-entity path
# (no telegrams), and a row that rendered only where the guard runs
# would leave the unprotected install showing nothing.
# (DECISIONS/MAIN-orchestration-archive.md)
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_off()})
# ⚠️ ONE PAIR OF ROWS PER INVERTER, NAMED. A single "battery SoC" row
# on a site with two packs is a page that shows one pack and calls it
# the site. (DECISIONS/MAIN-orchestration-archive.md)
rows = []
for inv in self.inverters:
unit = None if len(self.inverters) == 1 else inv.name
rows.append((messages.LABEL_SOC, unit, inv.soc,
inv.driver.soc_source()))
rows.append((messages.LABEL_BATTERY, unit, inv.batt,
inv.driver.batt_source()))
if not self.p1_enabled:
# In P1 mode the check above replaces this one; leaving both in
# would report "no entity configured" for a meter_entity that is
# correctly unused, i.e. a permanent false NOT READY.
rows.insert(0, (messages.LABEL_GRID, None, self.grid,
o.get("meter_entity")))
# UX-08: the rows name the setting, never the entity id (STYLE.md).
for label, unit, value, entity in rows:
if not entity:
out.append({"ok": False, "warn": False, "id": "sensor",
"text": messages.row_sensor_unset(label, unit)})
elif value is None:
# ⚠️ SAFETY-56. THIS ROW ONCE ASSERTED A FALSE FACT ABOUT A
# NAMED ENTITY: `Freshness.reading()` returns None BY DESIGN
# while the gate withholds a numeric reading. ⚠️ FIXED BY
# SAYING LESS: the gate has its own surface (`stale_note()` in
# `liveness_notes()`).
# (DECISIONS/MAIN-orchestration-archive.md)
out.append({"ok": False, "warn": False, "id": "sensor",
"text": messages.row_sensor_unusable(label, unit)})
else:
out.append({"ok": True, "warn": False, "id": "sensor",
"text": messages.row_sensor(label, value, unit)})
for inv in self.inverters:
unit = None if len(self.inverters) == 1 else inv.name
if not inv.driver.configured():
out.append({"ok": False, "warn": False, "id": "control",
"text": messages.row_control_unset(unit)})
elif inv.dev_max is None:
out.append({"ok": False, "warn": False, "id": "control",
"text": messages.row_control_missing(unit)})
else:
out.append({"ok": True, "warn": False, "id": "control",
"text": messages.row_control(inv.dev_min,
inv.dev_max, unit)})
# DEV-02. Whether this controller can still put a number on each
# inverter: a dropped link that shows nothing on the page reads as a
# healthy site. Red only for a unit no longer live; the rest amber. The
# same notes, in the same order, as `liveness_notes()`.
# (DECISIONS/MAIN-orchestration-archive.md)
_now = datetime.now(timezone.utc)
for inv in self.inverters:
for note, red in ((inv.link_note(_now), not inv.is_live(_now)[0]),
(inv.stale_note(), False),
(inv.refusal_note(), False)):
if note:
out.append({"ok": False, "warn": not red, "text": note})
if self.answer.late_seen: # SAFETY-128
out.append({"ok": False, "warn": True, "id": "late",
"text": messages.row_readings_late(
self.answer.shown_s, self._late_zero)})
# SAFETY-03. Red while an over-rating clamp is engaged (amber for the
# integrator bound, SAFETY-40), and the engagement COUNT stays shown
# after it clears. Each count is shown under ITS alarm's name, never
# the two summed (UX-07/UX-08).
# (DECISIONS/MAIN-orchestration-archive.md)
_cw = self.clamp_wd
if _cw.active and _cw.bug:
out.append({"ok": False, "warn": False, "id": "power_too_high",
"banner": messages.banner_power_too_high(),
"text": messages.row_power_too_high(
_cw.facts, _cw.over_rating, shadow=self.shadow)})
elif _cw.active:
# SAFETY-40: the integrator bound alone is amber, not red.
out.append({"ok": False, "warn": True, "id": "not_keeping_up",
"text": messages.row_not_keeping_up(
_cw.bound_episodes)})
# No over-rating in THIS episode (`bug` would be set), so any count
# is from an earlier one: keep that software-fault evidence shown.
if _cw.over_rating:
out.append({"ok": False, "warn": True, "id": "power_too_high",
"text": messages.row_before(
messages.T_OUTPUT_CLAMP, _cw.over_rating)})
else:
if _cw.over_rating:
out.append({"ok": False, "warn": True, "id": "power_too_high",
"text": messages.row_before(
messages.T_OUTPUT_CLAMP, _cw.over_rating)})
if _cw.bound_episodes:
out.append({"ok": False, "warn": True, "id": "not_keeping_up",
"text": messages.row_before(
messages.T_LOOP_BOUND, _cw.bound_episodes)})
for inv in self.inverters:
if inv.last_write_ok is False:
out.append({"ok": False, "warn": False, "id": "write",
"text": messages.row_write_refused(
None if len(self.inverters) == 1
else inv.name)})
# SAFETY-02. Reported in both states. ⚠️ ONE ROW PER INVERTER: a trip
# on B leaves A commanding. Since SAFETY-30 the row says what the unit
# was compared against (`sign_wd.against`, the string the trip sentence
# uses); at N=1 the wording is unchanged.
# (DECISIONS/MAIN-orchestration-archive.md)
for inv in self.inverters:
unit = None if len(self.inverters) == 1 else inv.name
# ⚠️ ADDED ONLY WHEN THERE IS SOMETHING TO DISAMBIGUATE: at N=1 the
# two sentences below are the ones that have always been on the
# page, word for word (AC 8); at N>=2 the noun is load-bearing, so
# the row does not send an operator to P1 for a fault visible only
# on one inverter's own power.
# (DECISIONS/MAIN-orchestration-archive.md)
if inv.sign_wd.tripped:
out.append({"ok": False, "warn": False, "id": "direction",
"text": messages.row_direction_trip(unit)})
else:
held = inv.sign_wd.held_s(datetime.now(timezone.utc))
out.append({"ok": True, "warn": False, "id": "direction",
"text": messages.row_direction_check(
held, inv.sign_wd.cfg.hold_s, unit)})
# SAFETY-30: the SITE row. ⚠️ ONLY AT N>=2, and the absence at N=1 is
# the honest report: with one inverter the site comparison and the row
# above are the same sentence about the same actuator.
# (DECISIONS/MAIN-orchestration-archive.md)
if len(self.inverters) > 1:
if self.site_sign_wd.tripped:
out.append({"ok": False, "warn": False, "id": "site_direction",
"text": messages.row_site_direction_trip()})
else:
_sheld = self.site_sign_wd.held_s(datetime.now(timezone.utc))
out.append({"ok": True, "warn": False, "id": "site_direction",
"text": messages.row_site_direction_check(
_sheld, self.site_sign_wd.cfg.hold_s)})
# SAFETY-31. ⚠️ SITE-LEVEL, WHERE THE ROWS ABOVE ARE PER-INVERTER, and
# the row says so: there is one circulating figure for the site, and
# naming an inverter would invite clearing "the other one".
# (DECISIONS/MAIN-orchestration-archive.md)
_circ = self.site_circulating_w
if self.circ_wd.tripped:
out.append({"ok": False, "warn": False, "id": "circulating",
"text": messages.row_circulating_trip()})
elif len(self.inverters) <= 1:
# AC 5. At the shipped roster the quantity is identically zero for
# every value of every reading, so "armed" would be a claim to be
# watching something that cannot happen. Say what is true instead.
out.append({"ok": True, "warn": False, "id": "circulating",
"text": messages.row_one_inverter(
messages.CHECK_CIRCULATING)})
else:
held = self.circ_wd.held_s(datetime.now(timezone.utc))
out.append({"ok": True, "warn": False, "id": "circulating",
"text": messages.row_circulating_check(
_circ, held, self.circ_wd.cfg.hold_s)})
# SAFETY-42. ⚠️ PER INVERTER, AND WARN RATHER THAN BAD, WHICH IS THE
# ONE PLACE THE "reports, does not act" DECISION IS VISIBLE: every
# other latched row means the site is at 0 W, this one means it is
# STILL RUNNING and quietly short by one unit's share; `ok: False` with
# `warn: True` is this list's caution.
# (DECISIONS/MAIN-orchestration-archive.md)
if len(self.inverters) > 1:
for inv in self.inverters:
if inv.delivery_wd.tripped:
out.append({"ok": False, "warn": True, "id": "delivery",
"text": messages.row_not_delivering(inv.name)})
else:
_dheld = inv.delivery_wd.held_s(datetime.now(timezone.utc))
out.append({"ok": True, "warn": False, "id": "delivery",
"text": messages.row_delivery_check(
inv.name, _dheld,
inv.delivery_wd.cfg.hold_s)})
else:
# AC 5: at one inverter this check has nothing to find, so it is
# not called "armed" (as `circulating power: n/a` above).
# (DECISIONS/MAIN-orchestration-archive.md)
out.append({"ok": True, "warn": False, "id": "delivery",
"text": messages.row_one_inverter("Delivery check")})
if not o.get("estop_fitted", False):
out.append({"ok": False, "warn": True, "id": "estop",
"text": messages.row_no_estop()})
else:
out.append({"ok": True, "warn": False, "id": "estop",
"text": messages.row_estop_fitted()})
if not o.get("peak_forecast_entity"):
# ok=False + warn=True renders as a caution, not a pass. A check that
# is both is a check nobody reads.
out.append({"ok": False, "warn": True, "id": "peak_forecast",
"text": messages.row_no_peak_forecast()})
elif getattr(self, "_peak_fc_fault", None) is not None:
out.append({"ok": False, "warn": True, "id": "peak_forecast",
"text": messages.row_peak_forecast_unit(
self._peak_fc_fault)})
# OPT-17: a forecast summed from several entities names, by position,
# each member with no usable reading. A caution: control goes on.
gaps = getattr(self, "solar_fc_gaps", ())
for day, ents in (("today", getattr(self, "fc_entities", ())),
("tomorrow",
getattr(self, "fc_tomorrow_entities", ()))):
gone = [i for d, i, _e, _w in gaps if d == day]
if gone:
out.append({"ok": False, "warn": True, "id": "solar_forecast",
"text": messages.row_forecast_gap(
day, gone, len(ents))})
# TEL-11. ⚠️ NO ROW AT ALL WHEN THE ROSTER IS EMPTY (pure
# instrumentation: no warning spam). ⚠️ WHEN IT IS SET, A FAILED READ
# IS `ok=False, warn=True`, a CAUTION never `bad`: telemetry must not
# put a battery site into NOT READY. UX-08 replaced 0.11.0's sentences
# on purpose. (DECISIONS/MAIN-orchestration-archive.md)
roster = self.pv_roster
if roster:
# UX-08: sources are numbered in the order of the settings list,
# never named by entity id (STYLE.md). The per-source figures and
# units are what `pv.total()` returns; they stay in `pv_parts`.
flip = pv_read.inverted(self.o)
n_src = len(roster)
if self.pv_w is None and n_src == 1:
out.append({"ok": False, "warn": True, "id": "pv",
"text": messages.row_pv_none(self.pv_why)})
elif self.pv_w is None:
# ⚠️ THE ROW THAT SAYS THERE IS NO TOTAL, AND IT SAYS IT IN
# THOSE WORDS - and which sources are missing, by position.
out.append({"ok": False, "warn": True, "id": "pv",
"text": messages.row_pv_partial(
[i + 1 for i, (_e, watt, _y)
in enumerate(self.pv_parts) if watt is None],
n_src)})
else:
out.append({"ok": True, "warn": False, "id": "pv",
"text": messages.row_pv(
self.pv_w, n_src,
n_src == 1 and roster[0] in flip)})
# ⚠️ AND WHEN BOTH KEYS ARE SET, WHICH ONE WON IS STATED. `pv.py`'s
# `entities()` makes `pv_entities` REPLACE `pv_entity`, which is
# the rule an operator upgrading from 0.11.0 is most likely to trip
# over. (DECISIONS/MAIN-orchestration-archive.md)
if pv_read.entity_is_ignored(self.o):
out.append({"ok": False, "warn": True, "id": "pv",
"text": messages.row_pv_single_ignored()})
# TEL-14: a sign that looks reversed, per entity rather than on the
# total - see `pv.NEGATIVE_W` and DECISIONS/TEL-14-pv-sign.md §3.
for i, (ent, watt, _y) in enumerate(self.pv_parts):
if watt is not None and watt < pv_read.NEGATIVE_W:
out.append({"ok": False, "warn": True, "id": "pv",
"text": messages.row_pv_negative(
i + 1, n_src, watt, ent in flip)})
_inv_list = [str(x or "").strip()
for x in (self.o.get("pv_invert_entities") or [])]
for ent in pv_read.stray_inverts(self.o):
out.append({"ok": False, "warn": True, "id": "pv",
"text": messages.row_pv_stray(
_inv_list.index(ent) + 1)})
return out
def status_payload(self, lang: str = "en") -> dict:
checks = self.checks()
bad = [c for c in checks if not c["ok"] and not c["warn"]]
# SAFETY-87: a red row with `runs` (the peak alarms) is an alarm while
# control goes on, so it neither reads "Not ready" nor holds the page.
runs = [c for c in bad if c.get("runs")]
bad = [c for c in bad if not c.get("runs")]
running_alarm = waiting = False
# SAFETY-10, AND IT IS FIRST IN THE CASCADE: "The battery is NOT being
# controlled" may never be displaced by another condition. ⚠️ AND IT
# CARRIES A STANDING LATCH RATHER THAN HIDING ONE: `shadow.banner()`
# names the latch and goes red for it, so nothing the cascade would
# have said is lost. (DECISIONS/MAIN-orchestration-archive.md)
_shadow = shadow.banner(self.o, control_started=self.auto,
latched=self.shadow_latches())
if _shadow is not None:
level, banner = _shadow
elif self.circ_wd.tripped:
# ⚠️ ABOVE THE SIGN FAILSAFE, and the order is a decision: both are
# latched P_SAFETY stops and the banner carries one sentence; this
# one goes first because it is the fault the operator has NO OTHER
# WAY of learning about (a sign disagreement is visible at the
# meter, circulating power nowhere).
# (DECISIONS/MAIN-orchestration-archive.md)
level, banner = "bad", messages.banner_circulating()
elif self.site_sign_wd.tripped and len(self.inverters) > 1:
# SAFETY-30's site half, ABOVE the per-unit rows below and below
# circulating power above: the banner carries one sentence, so the
# one that says the widest true thing. A site sign trip parks EVERY
# inverter and the fault is in what the site was asking for; naming
# a unit would send an operator to swap the wrong box.
# (DECISIONS/MAIN-orchestration-archive.md)
level, banner = "bad", messages.banner_site_direction()
elif any(i.sign_wd.tripped for i in self.inverters):
# Outranks "Not ready": nothing is missing, something went wrong.
# At N>=2 the unit was graded against its own power, so the banner
# says so (see checks()). (DECISIONS/MAIN-orchestration-archive.md)
level, banner = "bad", messages.banner_direction(
len(self.inverters) > 1)
elif bad:
# ⚠️ `banner` IF THE ROW OFFERS ONE, `text` OTHERWISE: a row may
# say more than fits the headline (SAFETY-25's floor row).
# (DECISIONS/MAIN-orchestration-archive.md)
level, banner = "bad", messages.banner_not_ready(bad[0])
# SAFETY-112: nothing to do but wait, so Home says that instead
# of "Needs you now". Only when it IS the headline: a safety stop
# above outranks it and still needs a person.
waiting = bad[0].get("id") == "home_assistant"
elif not self.auto:
level, banner = "warn", messages.banner_stopped()
elif runs:
level, running_alarm = "bad", True
banner = runs[0].get("banner") or messages.headline_bi(
runs[0]["text"])
elif any(i.delivery_wd.tripped for i in self.inverters):
# ⚠️ SAFETY-42, AND IT IS A `warn` BANNER RATHER THAN A `bad` ONE,
# WHICH IS THE WHOLE "reports, does not act" DECISION IN ONE LINE
# (the site is STILL RUNNING, one unit short). ⚠️ BUT IT MUST
# DISPLACE "Running - holding grid at zero": that sentence is a
# claim the site cannot make while a unit is absent. It sits BELOW
# "Stopped". (DECISIONS/MAIN-orchestration-archive.md)
level, banner = "warn", messages.banner_not_delivering(
[i.name for i in self.inverters if i.delivery_wd.tripped])
elif self.maint.phase != IDLE:
# ⚠️ THE PACK IS NAMED ONLY WHEN THERE IS MORE THAN ONE: at N=1 the
# string is what it has always been, character for character.
# (DECISIONS/MAIN-orchestration-archive.md)
level, banner = "warn", messages.banner_maintenance(
self.maint.phase,
self.maint_unit.name if len(self.inverters) > 1 else "")
else:
level, banner = "ok", messages.banner_running()
def w(v):
return "—" if v is None else f"{v:,.0f} W".replace(",", " ")
# ⚠️ THE EARLIEST ACROSS THE PACKS, NOT THE FIRST PACK'S. `None` means
# "never run, due now" and has to win over any date, so it is tested
# for rather than sorted with. At N=1 this is that pack's own date.
# (DECISIONS/MAIN-orchestration-archive.md)
_now = datetime.now(timezone.utc)
_dues = [m.next_due(_now) for m in self.maints]
_waits = [u for u in (m.backoff_until(_now) for m in self.maints) if u]
next_due = None if any(d is None for d in _dues) else min(_dues)
rows = [
("Grid", w(self.grid)),
("Battery", w(self.site_batt_w)),
# SAFETY-31, and it belongs DIRECTLY UNDER the two figures it is
# not derivable from ("Grid 0 W, Battery 0 W, Circulating 6000 W"
# is the whole card in three rows). Only shown at N>=2: at one
# inverter it is identically zero.
# (DECISIONS/MAIN-orchestration-archive.md)
*(() if len(self.inverters) <= 1
else ((("Circulating", w(self.site_circulating_w)),))),
# TEL-11, and ONLY when a source is configured - see `checks()`.
# `w(None)` renders "-", which is how this row says "no reading"
# rather than "0 W". (DECISIONS/MAIN-orchestration-archive.md)
*(() if not self.pv_roster else ((("Solar production",
w(self.pv_w)),))),
("Battery level", "—" if self.pack_floor_soc is None
else f"{self.pack_floor_soc:g} %"),
("Power request", w(self.target)),
# SAFETY-10, and it sits BETWEEN the two rows it reconciles.
# "Commanded 0 W" above and a "Why" below that explains a trade is
# the exact pair an operator would otherwise have to guess at; this
# row is what makes the two of them consistent, and it is rendered
# in EVERY state - including `off`, where it says the battery IS
# being controlled - because a surface whose ABSENCE is how you
# learn something is a surface you have to already know about.
("Shadow mode", shadow.words(
self.o, control_started=self.auto,
would_w=self.shadow_would_w,
# SAFETY-47. THE FLAG THE CYCLE RECORDED, NOT ONE DERIVED HERE
# - the page runs on its own task and `self.peak_guard` has
# moved on. See `Controller.__init__`.
sized_from_meter=self.shadow_sized_from_meter,
reason=self.why_words)),
("Why", self.why_words),
("Maintenance phase", self.maint.phase if len(self.inverters) <= 1
else f"{self.maint.phase} ({self.maint_unit.name})"),
# ⚠️ ONLY WHEN A PACK IS ACTUALLY WAITING, so a one-inverter status
# page - where `_maint_deferred` is empty on every tick - carries
# exactly the rows it carried before.
*((("Maintenance waiting", "; ".join(f"{n}: {why}"
for n, why in self._maint_deferred)),)
if self._maint_deferred else ()),
# MAINT-13: only while a failed cycle waits, so a site with nothing
# failed carries exactly the rows it carried before.
*((("Maintenance paused", messages.row_maint_waits(
min(_waits).strftime("%Y-%m-%d"))),) if _waits else ()),
("Maintenance due", "now" if next_due is None else next_due.strftime("%Y-%m-%d")),
("Cheap window", "yes" if self.cheap else "no"),
("Tariff", self.tariff_words),
# PRICE-01: only while no price covers now.
*((("Prices", messages.row_no_prices(*self._gap_args())),)
if self.price_gap else ()),
# FCST-04. WHAT §8.3 HAS TO CARRY FORWARD, the difference between a
# 48-hour plan and a 12-hour one on a weekday morning. Its own row:
# "Tariff" says what the plan IS, this says what it could still be
# filled from if the feed is late again.
# (DECISIONS/MAIN-orchestration-archive.md)
("Price history", self.price_history.words),
# OPT-04. The strategy's own sentence, not a re-derivation: every
# refusal it can make carries a reason a human can act on. ⚠️
# TARIFF-11: `self.arb is None` is NOT "trading is off" (cycle()
# returns at the input hold first); `arbitrage_row()` reads the
# option, and `cycle_at`/`arb_at` make "no decision this cycle" an
# observation. (DECISIONS/MAIN-orchestration-archive.md)
("Arbitrage", arbitrage_row(
on=arbitrage.enabled(self.o) or self.modes_on,
decision=self.arb,
decided_at=self.arb_at, cycle_at=self.cycle_at,
now=datetime.now(timezone.utc), why=self.why_words)),
]
held = level == "bad" and not running_alarm
# UX-46. The page's language is chosen once, here, for the Home
# sentences, checks, rows that carry one and the banner; a plain str
# (no Dutch twin) stays as it is.
# (DECISIONS/MAIN-orchestration-archive.md)
checks = [dict(c, text=messages.pick(c["text"], lang)) for c in checks]
rows = [(k, messages.pick(v, lang)) for k, v in rows]
banner = messages.pick(banner, lang)
out = {
"banner": banner, "level": level, "rows": rows, "checks": checks,
"hint": self.hint,
# The action log itself, newest first: not shown on the page (UX-08
# 2d) but readable in the `status` JSON, since several events are
# written nowhere else. (DECISIONS/MAIN-orchestration-archive.md)
"events": list(self.events),
}
# UX-13 P1: the Home screen's structured half. Read-only, and it may
# never cost the page its rows: a fault here is logged and the old
# fields are served alone (the page then shows the installer details).
try:
out.update(homeview.build(self, level=level, checks=checks,
lang=lang, held=held, waiting=waiting))
except Exception: # noqa: BLE001
# Once per process at ERROR: the page polls every 3 s.
if not getattr(self, "_home_failed", False):
self._home_failed = True
_LOG.exception("Home view could not be built, so the page "
"shows the plain status rows only")
else:
_LOG.debug("Home view failed again", exc_info=True)
out["home_error"] = True
return out
def forecast_payload(self, lang: str = "en") -> dict:
"""UX-54: the Forecast tab's data. Built on request, from what the
control cycle already holds; no Home Assistant call. Today's blocks are
Home's own, so `status_payload()` is built first and read."""
try:
return dayview.build(self, self.status_payload(lang=lang),
datetime.now(timezone.utc), lang)
except Exception: # noqa: BLE001
if not getattr(self, "_forecast_failed", False):
self._forecast_failed = True
_LOG.exception("The Forecast tab could not be built")
else:
_LOG.debug("The Forecast tab failed again", exc_info=True)
return {"ok": False}
async def handle_action(self, what: str, *, unit=None, value=None):
now = datetime.now(timezone.utc)
if what in ("pack_use", "pack_mode", "pack_sell"):
return self._pack_action(what, unit, value, now)
if what == "auto_toggle":
self.auto = not self.auto
self.store.set("auto", self.auto)
self.log_event("control started" if self.auto else "control stopped",
hint=messages.hint("control_started" if self.auto
else "control_stopped"))
if self.auto:
# ⚠️ THE ONLY WAY OUT OF A SIGN-DISAGREEMENT TRIP, on purpose:
# it clears on a deliberate human start, not on the condition
# going away (the condition ALWAYS goes away, because the trip
# commands 0 W). ⚠️ IT CLEARS EVERY INVERTER'S LATCH, AND SAYS
# SO PER INVERTER, each under its OWN key.
# (DECISIONS/MAIN-orchestration-archive.md)
for inv in self.inverters:
if not inv.sign_wd.tripped:
continue
inv.sign_wd.reset()
inv.store_set("sign_tripped", False)
inv.store_set("sign_reason", "")
self.log_event(f"sign-disagreement failsafe cleared by "
f"operator on {inv.name}",
hint=messages.hint("stop_cleared",
unit=inv.name))
# ⚠️ AND THE PRE-DEV-02 FLAT KEYS GO WITH THEM,
# UNCONDITIONALLY: this is what makes `flat True + namespaced
# False` MEAN something, and why `_grade_store_migration()` can
# run on every start. Left behind, a flat key is a fossil that
# re-arms the failsafe on every restart.
# (DECISIONS/MAIN-orchestration-archive.md)
self.store.set("sign_tripped", False)
self.store.set("sign_reason", "")
# SAFETY-30's SITE latch, cleared by the SAME press for the
# same reason (the trip commands 0 W, so the condition goes
# away on its own). ⚠️ UNCONDITIONAL, NOT GUARDED ON THE
# ROSTER: an install reconfigured back to one inverter would
# otherwise keep `site_sign_tripped: true` for ever.
# (DECISIONS/MAIN-orchestration-archive.md)
if self.site_sign_wd.tripped:
self.log_event("site sign-disagreement failsafe cleared "
"by operator",
hint=messages.hint("site_stop_cleared"))
self.site_sign_wd.reset()
self.store.set("site_sign_tripped", False)
self.store.set("site_sign_reason", "")
# SAFETY-31, cleared by the SAME press and for the same reason.
# ⚠️ AND `_circ_announced` GOES WITH IT: left True, the NEXT
# trip in this process would latch, stop the site and raise no
# notification. (DECISIONS/MAIN-orchestration-archive.md)
if self.circ_wd.tripped:
self.circ_wd.reset()
self.store.set("circ_tripped", False)
self.store.set("circ_reason", "")
self.log_event("circulating-power trip cleared by operator",
hint=messages.hint("site_stop_cleared"))
self._circ_announced = False
# SAFETY-42, cleared by the SAME press, for a reason that is
# NOT the one above: this latch commands nothing, so its
# evidence still stands and it could clear itself. It does not:
# a unit that stopped delivering and resumed is an INTERMITTENT
# fault. ⚠️ AND `_delivery_announced` GOES WITH IT, like
# `_circ_announced`. (DECISIONS/MAIN-orchestration-archive.md)
for inv in self.inverters:
if inv.delivery_wd.tripped:
self.log_event(f"not-delivering report on {inv.name} "
f"cleared by operator",
hint=messages.hint(
"not_delivering_cleared",
unit=inv.name))
inv.delivery_wd.reset()
inv.store_set("delivery_tripped", False)
inv.store_set("delivery_reason", "")
self._delivery_announced = set()
if not self.auto:
# ⚠️ THE WHOLE SITE, TARGETS INCLUDED - see
# command_site_zero(). SMA-10: Stop gives hand-back units back.
# (DECISIONS/MAIN-orchestration-archive.md)
await self.command_site_release()
return {"auto": self.auto}
if what in ("maint_start", "maint_abort") and unit is not None:
# MAINT-11: the operator named the battery. A request with no unit
# falls through to the branches below, unchanged.
return await self._maint_unit_action(what, unit, now)
if what == "maint_start":
# ⚠️ WHICH PACK, BECAUSE THERE ARE NOW SEVERAL AND THE BUTTON HAS
# ONE LABEL: `_maint_button()` picks the pack that holds the
# maintenance slot, else the one longest without a cycle; at N=1
# both are `maints[0]`. This is the bare request; a named battery
# is `_maint_unit_action()` (MAINT-11).
# (DECISIONS/MAIN-orchestration-archive.md)
_m = self._maint_button(now)
for msg in _m.force_start(now):
self.log_event(msg, hint=messages.hint("maintenance",
phase=_m.phase))
return {"phase": self.maint.phase}
if what == "maint_abort":
# Aborts the pack that is actually cycling - `_maint_button()` again
# - and then zeroes the SITE, which is what it always did.
_m = self._maint_button(now)
for msg in _m.abort(now, "operator"):
self.log_event(msg, hint=messages.hint("maintenance",
phase=_m.phase))
await self.command_site_zero()
return {"phase": self.maint.phase}