adminandClaude Opus 5 1abca15520 Compatibility gate: check the serial tag, not the model name
Platform is identified by characters 6-8 of the serial number, and only
platform 105 (ES/EM/BP - ESU EMU ESA BPS BPU EMJ IJL) speaks the AA55-era
meter bus this product emulates. The reference unit is 95000BPS225W0290 -> BPS.

Everything with a "-20"/G2 suffix is a different platform: SBP G2 (SPB/SPN) and
ES G2 (ESN/ESC) are platform 745, ET/EH/BT are 205/745/753. PV-only inverters
(SDT/DST/MSU/NSU) have no battery to control at all.

Added as the first item in Step 0 of the field guide, because it is a 60-second
check that decides whether the job can be quoted, and as a table in the README.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:56:20 +02:00