UX-13 P4 review fixes (PR #146, comment 1887)
R1: first_start also needs a Store created at this boot (Store.fresh), so
    old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 06:12:09 +02:00

5.6 KiB

UX-13 P4 — the setup wizard, and when it opens by itself

Status: DECIDED 2026-09-28 (P4 dev; the design and mockup were approved 2026-09-27). Card 6ab979852f3eca02fb40f69e. Builds on UX-13-one-layout-table. Design note: goodwe-session/UX-13-design.md §1, §3.6.

1. What the wizard is

The Setup tab draws the Installer view's page model one step at a time: a field is on step n when its uilayout.Field says wizard=n. It uses P2's controls, /config/validate and /config/save. No route was added. uilayout.py holds what a field cannot say: the kettle table (KETTLE), the optional step and the shadow switch (SHADOW). Step 5 has no battery modes yet (OPT-11); it says they come later.

A step moves on when no refusal is anchored to one of its shown fields (uipage.step_problems). A refusal on a hidden field, a field on no step or no field at all blocks the last step, which lists every refusal.

2. When it opens by itself (uipage.setup_needed)

The page opens #setup only when it is opened with no route, and only when /config/model gives a reason:

  • no_power_request: the stored options name no inverter to control.
  • first_start: this boot found no /data/state.json (Store.fresh), the Store has no setup_done and no auto key, and control is not started. auto is the key Start/Stop writes. The startup gate exits 78 before the controller writes the Store, so a new install's first good boot is fresh.

"Never started" alone is not enough: both TEST-23 add-ons have auto_start off and no auto key, and one has run in shadow for weeks (review of PR #146, R1). So a Store read from a file is an old site, and it is never sent to the wizard. A new install that restarts before the page is opened is not sent either, and its Setup tab still works. A site that runs control, or ever started or stopped it, is never sent. Without a Store the answer is no. The wizard's save writes setup_done (an ISO time) to the Store. A save from the Installer view does not.

Not decided here, for the owner: the add-on exits 78 before it serves the page when the stored options name no power request entity, which is what a brand-new install ships (config.yaml's setpoint_entity: ""). So on a truly new install the installer fills in "Inverter setpoint entity" on the Configuration tab first, and the wizard opens on the next page visit. Serving a setup-only page from a refused configuration would change the CFG-01 startup gate and UX-02 §4 ("the panel is not available when it is most needed"), so it is left as an open question.

3. The kettle test and the sign checks

Step 1 reads the meter's entities now (GET ha/entities?entity=, one hass.state() read, in W) before and after a kettle is switched on. The change, not the sign, decides: a rise of at least 500 W keeps meter_invert off, a fall turns it on. For a net entity or import and export, a fall cannot be fixed by an option, so the step is not passed and the page says what to check. A meter the add-on reads itself (HomeWizard, MQTT) cannot be read by the page, so the test is skipped and Home shows the direction after the restart. The installer may skip the test, because a cloud can fake a fall; the last step then warns, and after a fall it says the reading went down.

The battery and solar signs cannot be forced from the page, which never commands an inverter. The last step reports each battery's reading with its direction ("reads 800 W charging now, so check the inverter shows the same") and warns when a solar entity reads below zero without its "reads negative" switch. It also warns when meter + solar + battery, all known, add up to a house using less than -300 W: a battery sensor reversed while giving power. An idle or charging battery cannot be judged that way.

4. The last step

validate.setup_checks() sits beside the rules because it names option keys. It reads nothing itself: web.py passes a Home Assistant entity list at most 5 s old, the running options, the running meter reading and today's price count. Tiers are ok, info, warn and bad. A power request entity missing from Home Assistant is bad, because a write to it is answered 200 (SAFETY-77) and only the entity list can tell. So is Home Assistant not answering, since the list is then unknown. The wizard does not save while anything is bad. It then saves through P2's path (setup: "done") and asks for the restart as the second, confirmed request, with a dialog that names the 0 W. The shadow switch is on by default and writes shadow_mode: on, which holds every inverter at 0 W after a restart even if control is started. Off keeps the stored value, or auto if that was on. The switch goes only on the model the wizard posts, never into the page model the Installer view also saves.

5. The stale save lists only what moved (P2 test, finding a)

/config/model remembers the last 16 blobs it handed out, by fingerprint. On a stale save the add-on compares that blob with what is stored now, so the banner lists only the other surface's changes. changed (stored against the posted blob) is unchanged for the classic page's "theirs → mine" list. When the fingerprint was not handed out by this process, it falls back to changed.

6. How it is held

  • test_setup.py: the steps and tables, the kettle logic (and the page's copy of it), step blocking, the first-run rule on new and TEST-23 sites, the live checks, the save through the P2 path, the stale fix, and the words.
  • tools/ux13_wizard_blobs.py produces every blob the wizard can save from a new install and three TEST-23 sites (88 accepted by the shipped validator). At P4 all 88 were accepted by Supervisor 2026.08.0's AppOptions, offline, 78 keys each.