EV-18 review round 2: the contradiction latch touches only the alarm; an unknown energy reading is not a contradiction
- [Critical] The latch set `w = None` before `_car_quarter`, so with cover
  off the guard's input (`car_exclude`) counted the car as house and the
  batteries discharged. The latch now changes only the figure graded for the
  alarm; the car's energy count, the guard's input and the car-over row keep
  the unlatched `car_alarm_w()`. Cover-off N4 twins (energy gap, T9(c) liar,
  SoC 60 % and at the reserve) give the same commands as without the latch.
- [Major] `corroborated()` is False for an unknown energy reading, so one
  missing reading latched a correct figure for the quarter. New
  `CarTracker.contradicted()`: only a meter that answered over a whole window
  and fell short. R1 (energy entity unknown 1 s at E+200, T2 and T3 shapes):
  red for that cycle only, explained from the next.
- Minors: unit checks that a contradiction in our own pause latches nothing
  (MF) and that the latch ends with the quarter (MG).