adminandClaude Opus 5 0a1e61dbc9 Packaged as a Home Assistant add-on, with a field guide
Turns the reference RS485 controller into something a technician can install
at a client site: a typed config form instead of YAML, an ingress UI that
names misconfiguration in words, and persistent state that cannot be broken by
a timezone.

Why an add-on rather than YAML packages or blueprints:

- Blueprints cannot create helpers, and the maintenance cycle is a state
  machine whose phase and completion date must survive restarts.
- YAML packages need filesystem access, a configuration.yaml edit and a
  restart - none of which belong in a client install.
- Add-ons authenticate with SUPERVISOR_TOKEN, so there is no long-lived token
  to generate, store or leak on someone else's machine.
- Requires HA OS/Supervised. Container and Core installs cannot run add-ons at
  all, which is a market decision, not an oversight.

The control law and the maintenance machine are pure functions with no Home
Assistant imports, and both ship with runnable checks (22 and 22 assertions).
Every assertion corresponds to a rule whose absence caused an observed failure
on hardware - the saturation duration term, the clamp-before-slew ordering, the
deadband, the sign convention.

One behaviour deliberately differs from the implementation it replaces: when
its inputs go missing this commands 0 W rather than replaying the last
setpoint. The reference version kept replaying, which the hardware watchdog
cannot catch - from the ESP32's side, Home Assistant is still talking to it.

Includes the ESPHome firmware (now parameterised: node name, inverter rating,
watchdog timeout) and the optional RS485 e-stop. FIELD-GUIDE.md carries the
commissioning gates, all judged on the wire rather than on how Home Assistant
looks, plus the written statement a site without an e-stop needs signed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:15:25 +02:00

114 lines
4.6 KiB
Python

"""Runnable check for the control law. `python3 test_control.py`
No framework, no fixtures - it needs to run on a tech's laptop and in CI with
nothing installed. Every assert here corresponds to a rule that exists because
its absence caused an observed failure on real hardware.
If you change control.py, run this. If it fails, the inverter would have done
something you did not intend.
"""
import sys
from app.control import Tuning, compute, maintenance_charge_floor, peak_at_risk
T = Tuning()
fails = []
def check(name, cond):
if cond:
print(f" ok {name}")
else:
print(f" FAIL {name}")
fails.append(name)
print("control law")
# Deadband: inside meter noise, hold exactly - do not drift.
d = compute(prev_w=900, grid_w=10, actual_w=900, tuning=T)
check("deadband holds the command", d.target_w == 900 and d.reason == "deadband")
d = compute(prev_w=900, grid_w=20, actual_w=900, tuning=T)
check("outside deadband it acts", d.target_w != 900)
# Proportional: 0 + 0.6*500 = 300
d = compute(prev_w=0, grid_w=500, actual_w=0, tuning=T)
check("proportional step (gain 0.6)", d.target_w == 300)
# Sign: exporting (negative grid) must CHARGE (negative target).
d = compute(prev_w=0, grid_w=-500, actual_w=0, tuning=T)
check("export drives charging", d.target_w == -300)
# Clamp
d = compute(prev_w=1900, grid_w=1000, actual_w=1900, tuning=Tuning(max_w=2000, slew_w=5000))
check("clamped to max_w", d.target_w == 2000)
# Slew: from 0 with a huge error, no more than slew_w in one cycle.
d = compute(prev_w=0, grid_w=5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
check("slew limits one cycle", d.target_w == 1000)
# Saturation needs DURATION: one diverging cycle must NOT freeze.
t = Tuning(saturation_w=500, saturation_cycles=3)
d1 = compute(prev_w=2000, grid_w=500, actual_w=1000, tuning=t, sat_count=0)
check("one saturated cycle does not freeze", not d1.frozen and d1.sat_count == 1)
d2 = compute(prev_w=2000, grid_w=500, actual_w=1000, tuning=t, sat_count=d1.sat_count)
d3 = compute(prev_w=2000, grid_w=500, actual_w=1000, tuning=t, sat_count=d2.sat_count)
check("three consecutive saturated cycles freeze", d3.frozen)
check("freeze forbids raising magnitude", d3.target_w <= 2000)
# ...and one good cycle clears the counter immediately.
d4 = compute(prev_w=2000, grid_w=500, actual_w=1990, tuning=t, sat_count=3)
check("counter resets when tracking resumes", d4.sat_count == 0 and not d4.frozen)
# Freeze must still allow the magnitude to FALL (that is the escape route).
d = compute(prev_w=2000, grid_w=-800, actual_w=1000, tuning=t, sat_count=3)
check("freeze still allows magnitude to fall", d.target_w < 2000)
# Charge-only (maintenance charge phase)
d = compute(prev_w=500, grid_w=500, actual_w=500, tuning=T, charge_only=True)
check("charge-only never discharges", d.target_w <= 0)
d = compute(prev_w=0, grid_w=0, actual_w=0, tuning=T, charge_only=True, charge_floor_w=800)
check("charge floor pulls at least the floor", d.target_w == -800)
# Charge floor must still respect slew (floor applied BEFORE slew).
d = compute(prev_w=0, grid_w=0, actual_w=0, tuning=Tuning(slew_w=200),
charge_only=True, charge_floor_w=2000)
check("charge floor is still slew-limited", d.target_w == -200)
# Quantisation
d = compute(prev_w=0, grid_w=7, actual_w=0, tuning=Tuning(deadband_w=1, step_w=10))
check("quantised to step_w", d.target_w % 10 == 0)
print("capacity tariff")
check("no forecast means no cap", maintenance_charge_floor(2500, None, 3500) == 2500)
check("headroom caps the charge", maintenance_charge_floor(2500, 2000, 3500) == 1500)
check("no headroom means no charge", maintenance_charge_floor(2500, 4000, 3500) == 0)
check("peak risk detected", peak_at_risk(4000, 3500) is True)
check("peak risk off without forecast", peak_at_risk(None, 3500) is False)
print("behaviour: 2 kW load step converges")
# Closed-loop sim. The plant is modelled as first-order-ish: it moves most of
# the way to the command each cycle (measured: 94 % by 3.3 s against a ~5 s
# cycle). House load steps by 2000 W at t=0.
prev, actual, sat, load = 0.0, 0.0, 0, 2000.0
cycles = 0
for i in range(12):
grid = load - actual # what the meter sees
d = compute(prev, grid, actual, T, sat)
prev, sat = d.target_w, d.sat_count
actual = actual + 0.94 * (prev - actual) # plant follows
cycles += 1
if abs(load - actual) < T.deadband_w:
break
check(f"converges within deadband in {cycles} cycles (<=6)", cycles <= 6)
check("no overshoot past the load", actual <= load + T.deadband_w)
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
sys.exit(1)
print("all checks passed")