UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified
  as data or as a built text, and every built text is produced by the real
  code and checked. This is the gap the 2d scan had: it counted `%s` as one
  word, so reasons built by loop_clamp_note() and friends were never seen.
- Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept):
  OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak
  guard (codes now PEAK_GUARD*), the migration report, price feed, price
  history and gate reasons. Plurals via messages.times()/count().
- Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff
  "one every 15 minutes or every hour", "not final yet" dropped.
- Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO,
  aiohttp access log only at log level debug, settings warnings once per
  start, one plain line per Home Assistant outage (hass.Outage).
- INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE",
  "NOT_OBSERVED", "did NOT land", "AND".
- Display bugs: WHY_WINNER covers every winner and safety reason
  (main.why_key(), part 7 finds them in the code); the meter row is amber
  "waiting for the first reading" inside its limit after a start; the
  missing-reading age is counted when the page asks.
- STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section).

No change to safety behaviour, alarm levels, notification ids, triggers,
cadence or the banner cascade. One row colour changes (meter at start),
justified in DECISIONS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 10:58:43 +02:00

352 lines
19 KiB
Python

"""SAFETY-31 - the power two inverters move through each other, which the meter cannot see.
Inverter A charging at 3 kW while inverter B discharges at 3 kW nets ~0 W at
P1. The site looks idle. In reality 3 kW is going round a loop through two
conversion stages continuously, for no benefit, and the wear on both packs is
real even though every instrument in this add-on says nothing is happening.
WHY NOTHING EXISTING SEES IT, AND IT IS STRUCTURAL RATHER THAN AN OVERSIGHT
==========================================================================
Every consumer of the site measurement is a consumer of the NET. SAFETY-02's
sign-disagreement watchdog gates on `abs(grid_w) > cfg.min_w` (300 W by
default) - with the grid at ~0 that gate never opens, on any cycle, for any
duration. The peak guard bills the quarter-hour average AT THE GRID
CONNECTION. The capacity tariff bills grid exchange. `freeze.looks_frozen()`
grades P1 against the site rail. There is one meter, it reads the sum, and
circulating power is exactly the component of per-unit power that the sum
DESTROYS. So this cannot be fixed by tuning a threshold on any existing
detector; it needs a quantity none of them are computing.
THE QUANTITY
============
circulating_w = sum(|B_i|) - |sum(B_i)|
Zero when every unit pulls the same way - then sum(|B_i|) == |sum(B_i)| by the
triangle equality. `2 * min(|B_a|, |B_b|)` at N=2 when they oppose, which is
twice the power going round the loop and is the right scale: that is what both
conversion stages are processing between them. It is non-negative always, it is
zero at N<=1 identically, and it needs no threshold to be interpretable - the
number IS the phenomenon in watts.
⚠️ IT IS COMPUTED FROM MEASURED PER-INVERTER POWER, AND THAT IS THE WHOLE CARD.
=============================================================================
The obvious cheap version reads the allocation record - the shares the
allocator just handed out - and reports the same formula over those. It would
be simpler, it would never see a `None`, and it would be worth NOTHING, for two
independent reasons.
The first is that it cannot fire. ALLOC-01 shipped the sign-coherence gate as
its AC 7 (`allocator.REFUSE_SIGN`, graded by `test_alloc.py` part 6): an
allocation whose shares carry two signs is REFUSED, both units named, no shares
returned. So a sensor over the allocation record is a sensor over a set the
allocator has already guaranteed is sign-coherent. It reads zero by
construction, forever, and a check written against it passes forever.
The second is the one MUTATION.md names as the third way a check lies. A sensor
derived from the allocation record can only ever confirm THE ALLOCATOR AGREES
WITH ITSELF. Every fault in this card's list is a divergence between what was
commanded and what the hardware is doing:
* a unit ignoring or lagging its share;
* a stale share still being executed by one inverter;
* SAFETY-25's deferred loop floor, or a maintenance drain, pinning one unit
while the loop drives the other;
* an inverter doing something of its own accord - and THIS HARDWARE HAS DONE
THAT TWICE. On 2026-09-02 the comms subsystem failed and the power stage
went on executing its last instruction for 6 h 25 m (HW-01). Through all of
it the allocation record was impeccable.
In every one of those the command side is coherent and the MEASUREMENT side is
not. So the input is `Inverter.batt` - this unit's own power, read from its own
`batt_entity`, which on the live system is holding register 0x0518, the
inverter's own AC power. DEV-02 made that per-instance; before it there was one
`batt` scalar on the Controller and this sensor could not have been written at
all.
⚠️ AND THIS IS THE MEASUREMENT HALF OF A PAIR. ALLOC-01's gate is the COMMAND
half: the allocator can no longer COMMAND circulating power. This module is the
detection half: circulating power the allocator never commanded. Neither one
replaces the other and neither is redundant - the gate refuses an allocation
before it is written, and cannot see a millisecond past that; this reads the
hardware and does not care what was written. Do not "unify" them.
THE TRIP, AND WHY A THRESHOLD ALONE IS A FALSE-ALARM GENERATOR
==============================================================
A momentary opposition is LEGITIMATE. Writes to the inverters are serialised
(one `hass.call()` at a time - see `Inverter`'s docstring on what a hung write
to A costs B), so on a cycle where the site target reverses, one unit receives
its new command up to a whole control cycle before its sibling. Both then slew
through zero, with a real ramp rate and a real first-order lag, and BETWEEN THE
TWO ZERO CROSSINGS THE UNITS GENUINELY OPPOSE. Nothing is wrong; the site is
turning around.
This project's doctrine on crying wolf is explicit (SAFETY-15, SAFETY-19) and
this is exactly the shape that generates it. So the trip is a threshold AND a
sustained window, and BOTH numbers were measured on the TEST-19 two-master rig
rather than chosen - see `CIRC_OPTION_DEFAULTS` for the measurements and
`DECISIONS/SAFETY-31-circulating-power.md` for the runs.
⚠️ THE WINDOW ACCUMULATES, WHICH IS WHY THIS IS NOT SAFETY-02's PROBLEM AGAIN.
The reason the sign watchdog is blind to the broadcast fight is that the
disagreement FLIPS SIGN on alternate ticks, so `disagree_since` is cleared
between every pair of them and the 180 s hold never accumulates (allocator.py's
docstring records the measurement). Circulating power cannot do that: it is a
MAGNITUDE, non-negative by construction, and a sustained loop holds it high on
every cycle rather than on every other one. An oscillation that genuinely
alternated between opposing and agreeing is not a circulating loop and should
not be reported as one.
"""
from dataclasses import dataclass
from datetime import datetime
# CFG-03. THE ONE IN-CODE COPY OF THESE DEFAULTS. `config.yaml`'s `options:`
# block is the source of truth an operator edits and the Supervisor reads;
# `schema:` holds the bounds. This dict exists for the reason
# `maintenance.MAINT_OPTION_DEFAULTS` does - the Dockerfile does not put
# config.yaml in the image, so the running add-on cannot read it - and
# `test_watchdog.py` pins the two together by READING config.yaml, so a drift
# goes red in CI rather than shipping.
CIRC_OPTION_DEFAULTS = {
# --- THE THRESHOLD, AND IT IS READ OFF A CURVE ------------------------
# ⚠️ MEASURED ON THE TEST-19 TWO-MASTER RIG, NOT CHOSEN. 924 closed-loop
# runs in which NOTHING is faulty - every unit executes the share the
# allocator gave it - over both families of stimulus that can produce
# legitimate opposition: single reversals (7 sizes x 5 write staggers) and a
# flapping load (7 periods x 4 amplitudes), each swept across the WHOLE
# range config.yaml accepts for the two settings that decide how fast the
# site can turn around, `gain` float(0.05,1.0) and `slew_w` int(50,5000).
# The worst CONTINUOUS opposition, as a function of the threshold:
#
# 100 W -> 505.0 s 300 W -> 10.0 s 700 W -> 5.0 s
# 200 W -> 445.0 s 350 W -> 10.0 s 1000 W -> 5.0 s
# 250 W -> 40.0 s 400 W -> 5.0 s 1700 W -> 0.0 s
#
# ⚠️ SAFETY-39 MOVED THAT SCHEMA FLOOR FROM 50 TO 0, AND THE CAMPAIGN ABOVE
# WAS NOT RE-RUN. It does not have to be, and here is the argument rather
# than the assurance. What these windows are about is how long the command
# takes to CROSS ITS RAIL - the swept worst case is the SLOWEST crossing,
# which is `slew_w` at its floor, 5000/50 = 100 cycles. `slew_w: 0` means
# "follow the rail" and resolves to `SLEW_RAIL_FRAC * max_w`, which is
# exactly 9 cycles at EVERY rail by construction. So the new value can never
# be the slowest crossing at any `max_w`, and it is strictly inside the
# envelope this campaign measured. An explicit number still spans 50..5000
# and is unchanged. If `SLEW_RAIL_FRAC` is ever loosened past 1/100, this
# paragraph stops being true and the campaign has to be re-run.
#
# THE KNEE IS AT 400 W and it is sharp. Below ~250 W a flapping load holds
# the sensor above the threshold for MINUTES at a time - 505 s at 100 W -
# and no window shorter than the 900 s billing quarter could tell that from
# a fault. At 400 W and above the worst legitimate episode collapses to 5.0
# s, ONE control cycle, and stays there. So this number is not a sensitivity
# preference; it is the edge of the regime in which the guard is
# answerable at all.
#
# 700 W is 1.75x the knee, and the margin is bought for one named reason:
# INVERTER B DOES NOT PHYSICALLY EXIST. Its ramp and lag in the rig are
# inverter A's, COPIED, carrying `measured=False` - SPIKE-04 measures the
# real ones. A slower or faster second unit moves the transient's shape, and
# the headroom above the knee is what absorbs that without re-opening this
# card. Revisit it when SPIKE-04 lands, not before.
#
# What it costs: a circulating loop smaller than 350 W per unit is not
# reported. That is deliberate - at that scale the round-trip loss is a few
# watts and the wear is proportionate to it.
"circulation_w": 700,
# --- THE WINDOW -------------------------------------------------------
# Two lower bounds, one upper, and the chosen value clears all three.
#
# LOWER, from the rig: 5.0 s. The worst continuous legitimate opposition
# above 700 W across all 924 runs is exactly one control cycle - a
# reversing site whose second write lands a cycle after the first, which
# is what the serialised write path does on every reversal.
#
# LOWER, from the firmware: `inverter.LINK_STALE_S`, 30 s. A unit still
# executing a stale share for less than that is a LINK fault, and the
# add-on already has an answer for it - liveness drops the unit and the
# survivors carry its share, with the record saying so. Firing inside that
# window would raise a second, louder alarm about a state that is already
# being handled, which is the SAFETY-15/SAFETY-19 failure exactly.
#
# UPPER, from the bill: 900 s, the quarter that sets the capacity tariff.
# A circulating loop must be caught and acted on well inside one.
#
# 75 s: fifteen control cycles - 15x the worst legitimate episode this rig
# can produce, 2.5x the firmware's own veto window, and 12x inside the
# quarter. ⚠️ IT IS DELIBERATELY NOT 60 OR 120. A round number here would be
# a guess wearing a measurement's clothes, and the three bounds above are
# what the number has to answer to.
"circulation_hold_s": 75,
}
@dataclass(frozen=True)
class CirculationConfig:
"""Defaults, not constants - config.yaml carries both. See CFG-03 above."""
min_w: float = float(CIRC_OPTION_DEFAULTS["circulation_w"])
hold_s: float = float(CIRC_OPTION_DEFAULTS["circulation_hold_s"])
def circulating_w(powers):
"""`sum(|B_i|) - |sum(B_i)|` over MEASURED per-inverter power, in W.
`powers` one measured power per inverter, in roster order, + = discharge.
A unit whose reading did not arrive is `None`.
Returns a non-negative float, or `None` when the answer is unknown.
⚠️ N<=1 IS IDENTICALLY ZERO AND RETURNS ZERO EVEN FOR A MISSING READING
(AC 5). With one term `sum(|B|) - |sum(B)| == |B| - |B| == 0` for EVERY
value of B, including a value nobody read. Returning `None` there would be
reporting an unknown where the algebra has no room for one, and it would put
a shipped one-inverter install permanently in the "cannot tell" state on a
quantity that cannot be anything but zero. Nothing changes at the shipped
roster; that is the compatibility promise this card makes.
⚠️ AND AT N>=2 A MISSING READING IS `None`, NOT ZERO, WHICH IS THE OPPOSITE
DIRECTION AND FOR A REASON. Zero would be this sensor reporting HEALTH from
an absence - the precise shape of the 2026-09-02 outage, where a subsystem
stopped answering and its silence read as calm for 6 h 25 m. An unknown
circulating figure is an unknown, it CLEARS the trip's window rather than
accumulating it (see `CirculationWatchdog.evaluate`), and the site is
already stopped for a missing per-unit reading anyway - `inputs_ok` requires
every unit's `batt`, and §11.1 rule 1 commands 0 W without consulting this.
"""
vals = list(powers)
if len(vals) <= 1:
return 0.0
if any(v is None for v in vals):
return None
vals = [float(v) for v in vals]
# ⚠️ max(0.0, ...) IS DEFENSIVE, AND IT IS AN EQUIVALENT MUTANT - SAID HERE
# RATHER THAN LEFT FOR THE NEXT MUTATION SWEEP TO REDISCOVER. The triangle
# inequality makes this non-negative mathematically, and in floating point
# it is non-negative too: for a same-sign roster `abs(v)` is the list itself
# up to one sign, so the two sums accumulate THE SAME MAGNITUDES IN THE SAME
# ORDER and are bit-identical; for a mixed-sign roster the two differ by
# 2*min(...), which is enormous beside any rounding. Searched, not assumed -
# 700 000 random rosters of 2 to 12 units across 10 orders of magnitude
# produced no negative result.
#
# So removing this line changes no observable and no check here would go
# red. It stays because the cost is one call and the failure it would
# prevent - a power sensor publishing -1e-16 W, which is the kind of value
# somebody eventually writes a `< 0` branch against - is out of proportion
# to it. Do not report its survival as a gap in the checks.
return max(0.0, sum(abs(v) for v in vals) - abs(sum(vals)))
def opposing(powers, min_w: float = 0.0):
"""The units pulling each way right now, as `(discharging, charging)` names.
Indices, not names - the caller owns the roster order. Used for the operator
sentence: "which two inverters are pushing against each other" is the first
thing somebody woken by this alarm needs, and reconstructing it from the
number alone is impossible.
`min_w` ignores units below a magnitude, so a unit resting at 3 W of
standby draw is not named as a participant in a 3 kW loop.
"""
pos = [i for i, v in enumerate(powers)
if v is not None and float(v) > float(min_w)]
neg = [i for i, v in enumerate(powers)
if v is not None and float(v) < -float(min_w)]
return pos, neg
class CirculationWatchdog:
"""ONE PER SITE, evaluated once per control cycle.
⚠️ ONE PER SITE, WHERE SAFETY-02's IS ONE PER ACTUATOR, AND THE ASYMMETRY IS
THE WHOLE ATTRIBUTION ARGUMENT. `SignWatchdog` concludes "THE UNIT I AM
DRIVING is pushing power the wrong way" - evidence about one actuator, so
the remedy is that actuator (arbiter.CLAIM_SCOPE calls `failsafe` a UNIT
claim for exactly this reason). Circulating power is not a property any one
inverter has. It is a property of a PAIR, it is defined by a sum across the
roster, and there is no fact of the matter about which of the two is the
offender: a unit ignoring its share and a sibling faithfully executing a
share computed to sum with it produce identical readings. So the quantity is
site-level, the watchdog is site-level, and the remedy below is site-level.
Latches, for `SignWatchdog`'s reason: the trip removes its own evidence. The
moment the site stops commanding, the loop it detected either persists (a
wedged unit, now visible at the meter) or vanishes (the add-on was one of
the two participants) - and in the second case a non-latching detector would
de-assert and start the whole thing again, three minutes at a time, forever.
"""
def __init__(self, cfg: CirculationConfig | None = None, *,
tripped: bool = False, reason: str = ""):
self.cfg = cfg or CirculationConfig()
self.over_since: datetime | None = None
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED - SAFETY-34, and it is the
# reason this card exists in the shape it does. `persistent_notification`
# is IN MEMORY: Home Assistant restarts and the card is gone, with the
# fault still running. That is precisely how the 2026-09-02 outage went
# unseen for 6 h 25 m while the detector had been correct for hours. The
# latch lives in `/data/state.json` - the add-on's only durable volume -
# and `main.py` RE-RAISES the notification from it on every start.
self.tripped = bool(tripped)
self.reason = reason if self.tripped else ""
# The worst figure seen during the current episode, for the operator
# sentence. Not persisted: it is colour on a reason string that IS.
self.peak_w = 0.0
def evaluate(self, circ_w, now: datetime) -> bool:
"""Advance the detector one cycle. Returns True while tripped.
`circ_w` this cycle's `circulating_w()` over MEASURED per-unit power,
or None when a reading is missing. None CLEARS the window
rather than accumulating it - see the module docstring, and
`SignWatchdog.evaluate` on the identical decision for a stale
meter. A frozen figure held against a moving one manufactures
a fault in about a window's worth of cycles.
`now` the caller's clock, so this is testable and replayable.
"""
if self.tripped:
# Latched. Do not re-evaluate: the trip removed the evidence.
return True
if circ_w is None or float(circ_w) <= self.cfg.min_w:
self.over_since = None
self.peak_w = 0.0
return False
circ_w = float(circ_w)
self.peak_w = max(self.peak_w, circ_w)
if self.over_since is None:
self.over_since = now
return False
held = (now - self.over_since).total_seconds()
if held < self.cfg.hold_s:
return False
self.tripped = True
# UX-10: plain sentences, every figure kept (test_messages.py part 6).
self.reason = (
f"CIRCULATING_POWER: {circ_w:.0f} W measured going round between "
f"the inverters for {held:.0f} s, peaking at {self.peak_w:.0f} W. "
f"The meter cannot see it, because it nets to zero there. Limits: "
f"over {self.cfg.min_w:.0f} W, held over {self.cfg.hold_s:.0f} s")
return True
def held_s(self, now: datetime) -> float:
"""How long the current opposition has stood, for the status page.
Takes the clock rather than reading one, for `SignWatchdog.held_s`'s
reason: every observable on this object is a pure function of what it
was handed, and an unclocked function is one nothing can test.
"""
if self.over_since is None:
return 0.0
return (now - self.over_since).total_seconds()
def reset(self) -> None:
self.over_since = None
self.tripped = False
self.reason = ""
self.peak_w = 0.0