Files
glenn schrooyenandClaude Opus 5.5 bdec66e97a SAFETY-95: a maintenance drain that ends hands back smoothly (N>=2)
When a battery's drain ended (done, Off, timeout, abort, stale link,
refusal), its drain floor stayed in the site target and landed on the
others: B 0 -> +1600 W in one cycle at a 1200 W house, exporting; under a
solar surplus B gave into the export.

Now, on that cycle, the loop starts from what the others stood at plus the
battery's new command, raised to the house's own point when the house needs
more (never above last cycle's start). While the battery settles, the loop
counts the batteries at its start instead of chasing the drain's tail on
the meter. Then one slew step a cycle. N=1 is unchanged.

test_safety95.py; DECISIONS/SAFETY-95-drain-end.md; one DOCS line.
test_modes.py: opt11 n2_maint re-pinned on purpose (its drain ends by a
refusal at 1655 s; B now stays at the house's 1420 W instead of 2500 W).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 12:44:25 +02:00

541 lines
25 KiB
Python

"""Runnable check for OPT-11 P1, battery modes. `python3 test_modes.py`
Each battery gets an on/off switch and a mode (Solar first, Leftover solar),
kept in the store and filed as a SOFT unit limit at P_MODE (35). Drives the
REAL `Controller` (read_inputs + cycle) through tools/opt11_identity.py's
harness, in simulated time. DECISIONS/OPT-11-battery-modes.md has the record.
1. With battery modes off, every command is byte-identical to release/1.0
a5dddad, at one inverter and at two (digests measured on that tree).
2. Solar order: surplus solar fills the Solar first battery, then spills to the
Leftover solar one; a full Solar first battery hands all of it on.
3. Off: the battery is asked for 0 W, the others carry the site, the loop is
bounded and never freezes on watts no battery may give; all off at N=1 and
N=2 asks 0 W.
4. Off stops and skips maintenance, with a log line; a battery in maintenance
gets no mode claim.
5. The actions: `pack_use` and `pack_mode`, what they store, log and refuse.
6. A mode range without 0 W is dropped as a software fault, logged once.
7. The Batteries screen's data.
Mutations (MUTATION.md, purged copies, graded over this file and the named
tests) are listed in the pull request and DECISIONS/OPT-11-battery-modes.md.
"""
import asyncio
import logging
import os
import sys
HERE = os.path.dirname(os.path.abspath(__file__))
sys.path.insert(0, os.path.join(HERE, "tools"))
import opt11_identity as rig # noqa: E402
from named_absence import nth, present # noqa: E402
import app.main as app_main # noqa: E402
from app import homeview, messages, packmode # noqa: E402
from app.control import MODE_BOUND # noqa: E402
from app.maintenance import DRAIN, IDLE # noqa: E402
from app.store import unit_key # noqa: E402
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
ON = {"battery_modes_enabled": True}
A, B = "inverter-a", "inverter-b"
def store_with(**modes):
"""A store where each named battery has (use, mode)."""
s = rig._Store()
for name, (use, mode) in modes.items():
s.data[unit_key(name, packmode.USE_KEY)] = use
s.data[unit_key(name, packmode.MODE_KEY)] = mode
return s
def spy_claims():
"""Record every claim list main.py's own `resolve` is handed."""
seen, real = [], app_main.resolve
def _spy(claims, **kw):
seen.append(list(claims))
return real(claims, **kw)
app_main.resolve = _spy
return seen, lambda: setattr(app_main, "resolve", real)
def spy_bounds():
"""Record the `bound` main.py hands `compute()` on every cycle."""
seen, real = [], app_main.compute
def _spy(*a, **kw):
seen.append(kw.get("bound", "absent"))
return real(*a, **kw)
app_main.compute = _spy
return seen, lambda: setattr(app_main, "compute", real)
def flat(t):
return 0.0
# ============================================================================ #
print("1. battery modes off: byte-identical to release/1.0 a5dddad")
# The digests below were printed by `python3 tools/opt11_identity.py` run on
# the a5dddad tree (the same file copied in, nothing else changed), in the CI
# image, on 2026-09-28. Each hashes 540 cycles: site target, every inverter's
# written value, the loop's reason, integrator and saturation count, the
# arbiter's sentence and the allocation record.
A5DDDAD = {
"n1": "fc3bca170c46920f08d86baee62ea883954a89ea6222d6bbf7d6652877226262",
"n2": "a60003b1930fa3cba21f3220670d9172b9ff438347d77ba9bc3383fca1ceb15a",
"n1_off": "fc3bca170c46920f08d86baee62ea883954a89ea6222d6bbf7d6652877226262",
"n2_off": "a60003b1930fa3cba21f3220670d9172b9ff438347d77ba9bc3383fca1ceb15a",
# Added in review (PR #149), printed on a5dddad the same way: both
# batteries due for maintenance, and the arbiter alone on 6000 seeded
# claim lists with the peak floor, trades, maintenance and refusals.
"n1_maint": "5a21d43ec7cbf95a224bbb9bca13a8e62a00161101b586ae9fa68ab565992977",
"n2_maint": "48a1ad96121592e207a4664fb2da9f5208a49b88e5802a358873a5d30cb8c18e",
"resolve": "43a874216711936e14b9185bcc8d26c58fe4f3cfc3c1c8eaf89bffd95d6e81ef",
}
_claims, _undo_c = spy_claims()
_bounds, _undo_b = spy_bounds()
try:
_now = {k: rig.digest(rig.run(**v)[0])
for k, v in rig.SCENARIOS.items() if k != "n2_maint"}
_now["resolve"] = rig.digest(rig.resolve_rows())
finally:
_undo_b()
# SAFETY-85: n2_maint (maintenance at N=2) is the one run with a bound.
_bounds_m, _undo_b = spy_bounds()
try:
_now["n2_maint"] = rig.digest(rig.run(**rig.SCENARIOS["n2_maint"])[0])
finally:
_undo_c()
_undo_b()
# SAFETY-78 changes n2_maint ON PURPOSE: on a5dddad and 5a4cdc2 its N=2 drain
# was refused on 392 of 540 cycles (site at 0 W); now none is. Printed on the
# SAFETY-78 tree the same way. Every other digest is unchanged.
# SAFETY-85 changes it again ON PURPOSE: while A's drain pin stands the loop
# is bounded by what the batteries can place, so when A drops out at t=1655 B
# follows the house down at once instead of unwinding 920 W too high. Was
# cd4d9cb5b7e29ff4ab4fe65dab5106683d8a599f09323fbdee4018ad9b28fcd1.
SAFETY78_N2_MAINT = \
"1afcd46b1b987868b110d2b0f4a7555848c9aa4728a836d4a2ce2a2107268497"
# SAFETY-95 changes it again ON PURPOSE: A's drain ends at t=1655 (its
# refusal), and B now stays at the house's 1420 W instead of jumping to
# 2500 W (1100 W export) and slewing back. Rows differ only at 1655-2105 s.
SAFETY95_N2_MAINT = \
"949e7c093dcf065257417de3f2f908e4d57311790abc9fba0a09aa4b5d64c0d2"
# SAFETY-91 changes n2 and n2_off ON PURPOSE: from t=1600 battery A is at its
# 20 % reserve, so B carries the house first and A gives last. With
# `_held_back()` reverted to SAFETY-87's (held only for the peak) both are
# a5dddad's again, which the check below grades.
SAFETY91_N2 = \
"9535c08f556d6d50bec8fb0872445173480c29b10df1a7c437ef73d6ddb2814d"
_real_hb = app_main.Controller._held_back
app_main.Controller._held_back = lambda self: self._peak_reserve()
try:
_n2_s87 = rig.digest(rig.run(**rig.SCENARIOS["n2"])[0])
finally:
app_main.Controller._held_back = _real_hb
_S91 = ("n2", "n2_off", "n2_maint")
for k in A5DDDAD:
print(f" {k:7} {'same' if _now[k] == A5DDDAD[k] else 'DIFFERS'} "
f"{_now[k][:16]}")
check("⭐ at N=1 and N=2, with the option absent and with it false, every "
"command, reason and allocation record over 540 cycles each is "
"byte-identical to a5dddad (house steps, a solar surplus, a battery "
"at its cut-out level, at N=2 a refusal with probes, both batteries "
"due for maintenance; n2, n2_off and n2_maint apart, below), and so "
"is the arbiter on 6000 claim lists",
{k: v for k, v in _now.items() if k not in _S91}
== {k: v for k, v in A5DDDAD.items() if k not in _S91})
# SAFETY-94: with SAFETY-87's held rule, A (cut out at 1600 s) now trips the
# stale gate at 1640 s, not 1635 s - 35 s after its command moved rather than
# after its reading last changed - so that run is no longer a5dddad's. It was
# a5dddad's (a60003b1...) before SAFETY-94. The shipped n2 is unchanged.
SAFETY94_N2_S87 = \
"4ddea7ef9dc1efa437af899675db442cd531b084ae4cec35951d7c7bb3d6d8b5"
check("...n2 and n2_off are the SAFETY-91 digest (A at its reserve gives "
"last), and SAFETY-87's held rule gives SAFETY-94's",
_now["n2"] == _now["n2_off"] == SAFETY91_N2 != A5DDDAD["n2"]
and _n2_s87 == SAFETY94_N2_S87)
check("...and n2_maint is the SAFETY-78 digest: the N=2 drain that a5dddad "
"refused on 392 of 540 cycles now runs (test_safety78.py), bounded by "
"SAFETY-85, its end handed back by SAFETY-95",
_now["n2_maint"] == SAFETY95_N2_MAINT != A5DDDAD["n2_maint"])
check("...and no cycle in those runs filed a `mode` claim, and only "
"n2_maint's (SAFETY-85: maintenance at N=2) handed `compute()` a bound",
_claims and not any(c.source == "mode" for cl in _claims for c in cl)
and _bounds and set(_bounds) == {None}
and any(b is not None for b in _bounds_m))
# ============================================================================ #
print("\n2. the solar order: Solar first fills, the rest spills to Leftover")
_surplus = (lambda t: -3200.0) # 3200 W more solar than the house uses
_full_a = (lambda u, t: 100.0 if (u == "a" and t >= 300) else 50.0)
_rows, _c = rig.run(2, extra=ON, dur=600.0, load=_surplus, soc=_full_a,
cut=lambda u, t: False,
store=store_with(**{A: (True, packmode.SOLAR_FIRST),
B: (True, packmode.LEFTOVER_SOLAR)}))
_room = [r for r in _rows if 200 <= r[0] < 300]
_full = [r for r in _rows if r[0] >= 500]
def _cmd(r):
"""One row's written values, by battery; ABSENTs if the row is missing."""
return (dict(r[2]) if present(r)
else {"a": nth((), 0, "a"), "b": nth((), 0, "b")})
print(f" A has room: A {_cmd(nth(_room, -1))['a']:+.0f} W, B "
f"{_cmd(nth(_room, -1))['b']:+.0f} W | A full: A {_cmd(nth(_full, -1))['a']:+.0f} "
f"W, B {_cmd(nth(_full, -1))['b']:+.0f} W")
check("⭐ while A (Solar first) has room it takes all it can, 2500 W, and B "
"(Leftover solar) gets only the spill, about 700 W",
present(nth(_room, -1))
and all(_cmd(r)["a"] == -2500.0 and -800.0 <= _cmd(r)["b"] <= -600.0
for r in _room))
check("⭐ once A is full, the surplus spills to B, up to B's rating",
present(nth(_full, -1))
and all(_cmd(r)["a"] == 0.0 and _cmd(r)["b"] == -2500.0 for r in _full))
_rows_off, _ = rig.run(2, dur=300.0, load=_surplus,
soc=lambda u, t: 50.0, cut=lambda u, t: False)
check("...and the same site with battery modes off splits 50/50, which is "
"what says the order above comes from the modes",
_cmd(_rows_off[-1])["a"] == _cmd(_rows_off[-1])["b"] < -1500.0)
_give = rig.run(2, extra=ON, dur=300.0, load=lambda t: 3000.0,
soc=lambda u, t: 50.0, cut=lambda u, t: False,
store=store_with(**{A: (True, packmode.SOLAR_FIRST),
B: (True, packmode.LEFTOVER_SOLAR)}))[0]
check("while giving power the modes keep OPT-09's weights: A Solar first and "
"B Leftover solar, both half full, share a 3000 W house equally",
_cmd(_give[-1])["a"] == _cmd(_give[-1])["b"] > 1400.0)
# ============================================================================ #
print("\n3. Off: 0 W on that battery, the loop bounded, no freeze")
_rows, _c = rig.run(2, extra=ON, dur=600.0, load=lambda t: 4000.0,
soc=lambda u, t: 50.0, cut=lambda u, t: False,
store=store_with(**{B: (False, packmode.SOLAR_FIRST)}))
_tail = _rows[40:]
print(f" house 4000 W, B off: A {_cmd(_tail[-1])['a']:+.0f} W, B "
f"{_cmd(_tail[-1])['b']:+.0f} W, site {_tail[-1][1]:+.0f} W, reason "
f"{_tail[-1][3]}, {_tail[-1][7]}")
check("⭐ B (Off) is asked for 0 W on every cycle and A carries the house up "
"to its rating",
all(_cmd(r)["b"] == 0.0 for r in _rows)
and all(_cmd(r)["a"] == 2500.0 for r in _tail))
check("⭐ the loop stays inside what the modes allow (2500 W) and never "
"freezes: no saturated-freeze reason, and the saturation count stays "
"below the freeze",
all(r[1] <= 2500.0 for r in _rows)
and not any(r[3] == "saturated-freeze" for r in _rows)
and max(r[5] for r in _rows) < _c.tuning.saturation_cycles
and _tail[-1][3] == MODE_BOUND)
check("...and nothing is left unmet: the allocation places the whole target",
all("UNMET" not in (r[7] or "") for r in _tail))
_bounds, _undo_b = spy_bounds()
try:
rig.run(2, extra=ON, dur=100.0, load=lambda t: 4000.0,
soc=lambda u, t: 50.0, cut=lambda u, t: False,
store=store_with(**{B: (False, packmode.SOLAR_FIRST)}))
finally:
_undo_b()
check("...because main.py hands compute() the loop bound, B's 0 W included: "
"[-2500, 2500]", _bounds and set(_bounds) == {(-2500.0, 2500.0)})
# Review (PR #149): a unit the allocator drops (stale link) must not count in
# the loop bound either, or the loop asks for watts nobody live can place.
_rows, _c = rig.run(2, extra=ON, dur=10.0, load=flat, soc=lambda u, t: 50.0,
cut=lambda u, t: False)
_both = _c.loop_bound([app_main.Claim.limit(
"supervised", app_main.P_SAFETY, -2500.0, 2500.0,
actuator=_c.actuator_of("supervised", i)) for i in _c.inverters])
_c.live_units = lambda: (A,)
_one_live = _c.loop_bound([app_main.Claim.limit(
"supervised", app_main.P_SAFETY, -2500.0, 2500.0,
actuator=_c.actuator_of("supervised", i)) for i in _c.inverters])
check("the loop bound counts only live units: both live [-5000, 5000], B's "
"link stale [-2500, 2500]",
_both == (-5000.0, 5000.0) and _one_live == (-2500.0, 2500.0))
for _n in (1, 2):
_st = store_with(**{A: (False, packmode.SOLAR_FIRST),
B: (False, packmode.LEFTOVER_SOLAR)})
if _n == 1:
_st = rig._Store()
_st.data[unit_key(app_main.UNIT_A, packmode.USE_KEY)] = False
_rows, _c = rig.run(_n, extra=ON, dur=300.0, load=lambda t: 3000.0,
soc=lambda u, t: 50.0, cut=lambda u, t: False,
store=_st)
check(f"every battery off at N={_n}: every command is 0 W, the site "
f"target is 0 W, the integrator stays at 0 and nothing freezes",
all(all(v == 0.0 for _u, v in r[2]) and r[1] == 0.0 and r[4] == 0.0
and r[3] != "saturated-freeze" for r in _rows))
_rows1, _ = rig.run(1, extra=ON, dur=300.0, load=lambda t: 1800.0,
soc=lambda u, t: 50.0)
_rows1o, _ = rig.run(1, dur=300.0, load=lambda t: 1800.0,
soc=lambda u, t: 50.0)
check("at N=1 a battery that is on (Solar first by default) follows the "
"house exactly as with battery modes off",
[r[:6] for r in _rows1] == [r[:6] for r in _rows1o]
and _cmd(_rows1[-1])["a"] > 1700.0)
# ============================================================================ #
print("\n4. Off stops and skips maintenance; maintenance outranks the mode")
MAINT = {"maintenance_enabled": True, "maintenance_start_hour": 11}
_st = store_with(**{A: (False, packmode.SOLAR_FIRST)})
_rows, _c = rig.run(2, extra={**ON, **MAINT}, dur=60.0,
load=lambda t: 500.0, soc=lambda u, t: 60.0,
cut=lambda u, t: False, store=_st)
print(f" both due at 11:00, A off: A {_c.maints[0].phase}, "
f"B {_c.maints[1].phase}")
check("⭐ a battery that is off starts no cycle, and does not hold the slot: "
"both are due, A (first in the roster) is off, so B starts",
_c.maints[0].phase == IDLE and _c.maints[1].phase == DRAIN)
_st2 = store_with()
_seen, _undo_c = spy_claims()
_msgs = []
async def _switch_b_off(c, t):
if t == 30.0:
_msgs.append(await c.handle_action("pack_use", unit=B, value=False))
try:
_rows, _c = rig.run(2, extra={**ON, **MAINT}, dur=60.0,
load=lambda t: 500.0, soc=lambda u, t: 60.0,
cut=lambda u, t: False, store=_st2,
before=_switch_b_off)
finally:
_undo_c()
_during = [cl for cl in _seen[:6]]
print(f" B off at 30 s while A drains: A {_c.maints[0].phase}, "
f"B {_c.maints[1].phase}; events: "
f"{[e for e in _c.events if 'switched' in str(e) or 'ABORT' in str(e)]}")
check("while A runs its cycle it gets no mode claim (maintenance at 60/40 "
"outranks the mode) and B, idle, gets one",
all({c.actuator for c in cl if c.source == "mode"} == {B}
for cl in _during))
_st3 = store_with()
_st3.data[unit_key(B, "phase")] = DRAIN
_st3.data["maint_schema_version"] = 1
async def _b_off_now(c, t):
if t == 10.0:
_msgs.append(await c.handle_action("pack_use", unit=B, value=False))
_rows, _c = rig.run(2, extra=ON, dur=30.0, load=lambda t: 500.0,
soc=lambda u, t: 60.0, cut=lambda u, t: False,
store=_st3, before=_b_off_now)
_ev = [str(e) for e in _c.events]
print(f" B mid-drain, switched off at 10 s: B {_c.maints[1].phase}; "
f"{[e for e in _ev if 'switched off' in e or 'ABORT' in e]}")
check("⭐ switching off a battery that is mid-cycle stops its cycle at once, "
"with a log line saying why",
_c.maints[1].phase == IDLE
and any("battery switched off" in e for e in _ev)
and _cmd(_rows[-1])["b"] == 0.0)
_st4 = store_with(**{B: (False, packmode.SOLAR_FIRST)})
_st4.data[unit_key(B, "phase")] = DRAIN
_st4.data["maint_schema_version"] = 1
_rows, _c = rig.run(2, extra=ON, dur=20.0, load=lambda t: 500.0,
soc=lambda u, t: 60.0, cut=lambda u, t: False, store=_st4)
check("...and a store that says Off for a battery mid-cycle (a restart) stops "
"it on the first cycle, and it is never asked to drain",
_c.maints[1].phase == IDLE
and all(_cmd(r)["b"] == 0.0 for r in _rows))
# ============================================================================ #
print("\n5. the actions: pack_use and pack_mode")
_rows, _c = rig.run(2, extra=ON, dur=10.0, load=flat,
soc=lambda u, t: 50.0, cut=lambda u, t: False)
_r1 = asyncio.run(_c.handle_action("pack_mode", unit=B,
value=packmode.LEFTOVER_SOLAR))
_r2 = asyncio.run(_c.handle_action("pack_use", unit=A, value=False))
print(f" {_r1} {_r2}")
check("pack_mode stores the mode under the battery's own key and says what "
"it now is",
_r1 == {"unit": B, "use": True, "mode": packmode.LEFTOVER_SOLAR}
and _c.store.data[unit_key(B, packmode.MODE_KEY)]
== packmode.LEFTOVER_SOLAR)
check("pack_use stores the switch, and both are written to the action log",
_r2 == {"unit": A, "use": False, "mode": packmode.SOLAR_FIRST}
and _c.store.data[unit_key(A, packmode.USE_KEY)] is False
and any("inverter-a switched off by operator" in str(e)
for e in _c.events)
and any("inverter-b mode set to leftover solar" in str(e)
for e in _c.events))
_bad = [asyncio.run(_c.handle_action("pack_use", unit="inverter-z",
value=True)),
asyncio.run(_c.handle_action("pack_use", unit=A, value="yes")),
# 0 == False in Python: a stored 0 would read back as ON.
asyncio.run(_c.handle_action("pack_use", unit=A, value=0)),
asyncio.run(_c.handle_action("pack_use", unit=A, value=1)),
asyncio.run(_c.handle_action("pack_mode", unit=A,
value="sell_only")),
asyncio.run(_c.handle_action("pack_mode", unit=A, value=None))]
check("an unknown battery, a switch that is not true or false (0 and 1 "
"included), and a mode "
"that does not exist are refused, "
"with a plain reason, and store nothing",
all(isinstance(x, dict) and set(x) == {"error"} for x in _bad)
and unit_key(A, packmode.MODE_KEY) not in _c.store.data
and _c.store.data[unit_key(A, packmode.USE_KEY)] is False)
_rows, _c0 = rig.run(2, dur=10.0, load=flat, soc=lambda u, t: 50.0,
cut=lambda u, t: False)
_r0 = asyncio.run(_c0.handle_action("pack_use", unit=A, value=False))
check("with battery modes off the actions are refused and store nothing",
set(_r0) == {"error"}
and unit_key(A, packmode.USE_KEY) not in _c0.store.data)
check("the old actions still take no battery and answer as before",
asyncio.run(_c0.handle_action("nonsense")) is None)
check("a store value from a later version (an unknown mode) reads as the "
"default, Solar first and on, never as Off",
packmode.read({unit_key(A, packmode.MODE_KEY): "grid_only",
unit_key(A, packmode.USE_KEY): "maybe"}, A)
== packmode.PackMode(True, packmode.SOLAR_FIRST))
# ============================================================================ #
print("\n6. a mode range without 0 W is a software fault, never obeyed")
_real_range = packmode.mode_range
packmode.mode_range = lambda pm, r: (100.0, 900.0)
_log = []
class _H(logging.Handler):
def emit(self, rec):
_log.append((rec.levelno, rec.getMessage()))
_h = _H()
logging.getLogger("goodwe").addHandler(_h)
try:
_rows, _c = rig.run(2, extra=ON, dur=60.0, load=lambda t: -2000.0,
soc=lambda u, t: 50.0, cut=lambda u, t: False)
finally:
packmode.mode_range = _real_range
logging.getLogger("goodwe").removeHandler(_h)
_errs = [msg for lv, msg in _log if lv >= logging.ERROR and "MODE_RANGE" in msg]
print(f" {_errs}")
check("⭐ both batteries still charge from the surplus (the forced range is "
"dropped, so no battery is made to give power) and no split is refused",
all(v <= 0.0 for _u, v in _rows[-1][2])
and _cmd(_rows[-1])["a"] < 0.0
and not any("REFUSED" in (r[7] or "") for r in _rows))
check("...and it is logged once per battery, as an ERROR naming the fault "
"code, not once per cycle",
len(_errs) == 2 and any(A in e for e in _errs) and any(B in e for e in _errs))
# ============================================================================ #
print("\n7. the Batteries screen's data")
_rows, _c = rig.run(2, extra=ON, dur=10.0, load=flat, soc=lambda u, t: 50.0,
cut=lambda u, t: False,
store=store_with(**{B: (False, packmode.LEFTOVER_SOLAR)}))
_bat = homeview.battery_rows(_c, False, True)
_bat_nl = homeview.build(_c, level="ok", checks=[], lang="nl")["batteries"]
print(f" {[(b['name'], b['use'], b['mode_key'], b['mode']) for b in _bat]}")
check("with battery modes on each row carries its switch, its state and its "
"stored mode, in the page's words",
[(b["use"], b["mode_key"], b["mode_choice"], b["mode"]) for b in _bat]
== [(True, "solar_first", "solar_first", "Solar first"),
(False, "off", "leftover_solar", "Off")]
and _bat_nl[1]["mode"] == "Uit")
_rows, _c0 = rig.run(2, dur=10.0, load=flat, soc=lambda u, t: 50.0,
cut=lambda u, t: False)
check("...and with them off the rows are what they were: no new keys, the "
"mode reads as before",
all("mode_key" not in b and b["mode"] == homeview.mode_house()
for b in homeview.battery_rows(_c0, False, True)))
# ============================================================================ #
print("\n8. the page's route: /action and /status over the real web app")
import socket # noqa: E402
import aiohttp # noqa: E402
from aiohttp import web as aioweb # noqa: E402
from app import web as app_web # noqa: E402
_rows, _c = rig.run(2, extra=ON, dur=10.0, load=flat, soc=lambda u, t: 50.0,
cut=lambda u, t: False)
async def _page():
# The configuration routes are not used here; a stand-in keeps the app
# from building a Supervisor client.
app = app_web.build_app(_c, selfcfg=object())
runner = aioweb.AppRunner(app)
await runner.setup()
sock = socket.socket()
sock.bind(("127.0.0.1", 0))
port = sock.getsockname()[1]
sock.close()
await aioweb.TCPSite(runner, "127.0.0.1", port).start()
out = {}
try:
async with aiohttp.ClientSession() as s:
root = f"http://127.0.0.1:{port}/"
for key, body in (
("mode", {"action": "pack_mode", "unit": B,
"value": packmode.LEFTOVER_SOLAR}),
("off", {"action": "pack_use", "unit": A,
"value": False}),
("bad", {"action": "pack_mode", "unit": A,
"value": "grid_only"})):
async with s.post(root + "action", json=body) as r:
out[key] = (r.status, await r.json(content_type=None))
async with s.get(root + "status") as r:
out["status"] = (r.status, await r.json(content_type=None))
async with s.get(root) as r:
out["page"] = (r.status, await r.text())
finally:
await runner.cleanup()
return out
_web = asyncio.run(_page())
print(f" {_web['mode']} {_web['off']} {_web['bad']}")
check("POST /action with pack_mode and pack_use names a battery and a value, "
"and answers what it stored",
_web["mode"] == (200, {"ok": True, "result": {
"unit": B, "use": True, "mode": packmode.LEFTOVER_SOLAR}})
and _web["off"][0] == 200 and _web["off"][1]["result"]["use"] is False)
check("...a value this release does not offer is a 400 with the plain reason "
"the page shows",
_web["bad"][0] == 400 and _web["bad"][1]["ok"] is False
and _web["bad"][1]["error"] == messages.pack_refused("value"))
_sb = {b["name"]: b for b in _web["status"][1].get("batteries", [])}
check("...and /status then shows both batteries' switch and mode for the "
"Batteries screen",
_web["status"][0] == 200
and (_sb.get(A, {}).get("mode_key"), _sb.get(B, {}).get("mode_key"))
== ("off", packmode.LEFTOVER_SOLAR))
check("the page carries the mode names from app/ui_text for its cards",
_web["page"][0] == 200 and "Leftover solar" in _web["page"][1]
and "Overschot zonne-energie" in _web["page"][1])
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
sys.exit(1)