Deploy 0.18.2 to master #200

Merged
admin merged 6 commits from deploy-0.18.2 into master 2026-10-17 01:59:55 +02:00
11 changed files with 415 additions and 16 deletions
Showing only changes of commit f0b4e68e49 - Show all commits
@@ -0,0 +1,18 @@
# SAFETY-118 - the peak forecast is read in its own unit
**Status: for review.** Tests: `test_safety118.py`.
`peak_forecast_entity` was read as a bare number, and anything under 50 was
multiplied by 1000 ("accept kW or W"). A W sensor reading 17 to 45 W, which a
real site did 430 times in one morning, was taken as 17 to 45 kW. The validator
also called a kW sensor wrong, which was false for this entity.
Decision: the size rule is gone. The entity is read through `pv.watts()`, the
same unit table and reader as the solar entities, so W, kW, MW and the rest
convert by the sensor's own `unit_of_measurement`. No unit, or a unit that is
not power (kWh), means the forecast is not used, exactly as if the option were
empty: the loop cap and every non-forecast peak step still apply. One WARNING
per cause, and a status row and a settings note say the same.
No size rule can be right in both units: 30 W and 30 kW are both ordinary.
The read is still one `GET /api/states/<id>` per cycle, as `hass.number()` made.
+2 -2
View File
@@ -210,7 +210,7 @@ The label and description each setting shows on the Configuration tab, in tab or
| Limits | Battery cut-out level (%) | `bms_soc_floor` | The level where the battery's own management system stops giving power. Read it off your battery rather than copying a figure. |
| Limits | Peak limit (W) | `peak_cap_w` | Your own number: the 15-minute average power the add-on keeps the grid under. Take it from your grid contract. |
| Limits | Margin below the peak limit (W) | `peak_margin_w` | The add-on aims this much below the peak limit, so a 15-minute period that ends a little high still stays under it. |
| Limits | 15-minute demand forecast entity (W) | `peak_forecast_entity` | Optional. A forecast of this 15-minute period's average power. Leave it empty and there is no peak limit. |
| Limits | 15-minute demand forecast entity (W) | `peak_forecast_entity` | Optional. A forecast of this 15-minute period's average power, in W or kW. With no power unit it is not used. Leave it empty and there is no peak limit. |
| Limits | Peak reserve (%) | `peak_soc_floor` | Peak limiting will not draw the battery below this level, but ordinary use can. Derived value, leave it unchanged. |
| Tariff | Dynamic price source | `price_provider` | Where prices come from. Choosing a source starts the price fetch, even with trading off. |
| Tariff | Supplier markup (EUR/kWh) | `price_markup_eur_kwh` | Your supplier's margin. It is added only when the price source does not already include it. |
@@ -1697,7 +1697,7 @@ DECISIONS/MAINT-13-full-pack-is-complete.md.
| option | meaning |
|---|---|
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Empty = no cap |
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Read in its own unit (W, kW or any power unit). No unit, or a unit that is not power, means it is not used, as if empty (SAFETY-118). Empty = no cap |
| `peak_cap_w` | The site's capacity-tariff target |
| `peak_margin_w` (50) | Watts the peak guard aims under `peak_cap_w` (SAFETY-79). Reports and the bill use `peak_cap_w` itself |
| `peak_soc_floor` (20) | **The percent below which the capacity-peak guard will not discharge the battery.** ⚠️ It bounds **the peak guard only** — it is **not a pack-wide reserve**, and ordinary self-consumption discharges straight past it (SAFETY-25, see below). Not optional and not the same thing as `maintenance_soc_floor` |
+30 -3
View File
@@ -1202,6 +1202,9 @@ class Controller:
# `grid` is P1, one meter, one connection, and belongs here.
self.grid = None
self.peak_fc = None
# SAFETY-118: the unit fault last logged for the peak forecast (None =
# no fault), so the warning comes once and again only if it changes.
self._peak_fc_fault = None
self.cheap = False
self._price_gated = False # MAINT-13: is a price gate set up
# PRICE-01. Which step of the price chain the prices come from (logged
@@ -3358,6 +3361,22 @@ class Controller:
self.pv_w, self.pv_why, self.pv_parts = pv_read.total(
list(zip(roster, states)), pv_read.inverted(self.o))
def _peak_fc_unit_log(self, fault) -> None:
"""SAFETY-118. One WARNING when the peak forecast's unit cannot be read
in watts, and again only if the unit changes; the unit is on DEBUG."""
if fault == self._peak_fc_fault:
return
self._peak_fc_fault = fault
if fault is None:
_LOG.info("The 15-minute demand forecast is used again.")
elif fault == "":
_LOG.warning("The 15-minute demand forecast has no unit, so it "
"is not used.")
else:
_LOG.warning("The 15-minute demand forecast is not in a power "
"unit, so it is not used.")
_LOG.debug("The 15-minute demand forecast reads in %r.", fault)
async def _read_forecast(self) -> None:
"""OPT-11 P4: the solar forecast sensors (`solarfc.read()`). A
failed or stale read is no forecast, never a zero."""
@@ -3448,11 +3467,15 @@ class Controller:
_reads.append(self._read_forecast())
await asyncio.gather(*_reads)
if o.get("peak_forecast_entity"):
raw = await self.hass.number(o["peak_forecast_entity"])
# Accept kW or W - nobody's quarter-hour forecast is 50 W.
self.peak_fc = None if raw is None else (raw * 1000 if abs(raw) < 50 else raw)
# SAFETY-118: read in its own unit, like the PV path. One state
# read, as `hass.number()` made. No unit or a unit that is not
# power: not used, as if the option were empty.
st = await self.hass.state(o["peak_forecast_entity"])
self.peak_fc, _why = pv_read.watts(st)
self._peak_fc_unit_log(pv_read.unit_fault(st))
else:
self.peak_fc = None
self._peak_fc_fault = None
now_e, avg_e = o.get("price_now_entity"), o.get("price_avg_entity")
if now_e and avg_e:
@@ -7240,6 +7263,10 @@ class Controller:
# is both is a check nobody reads.
out.append({"ok": False, "warn": True, "id": "peak_forecast",
"text": messages.row_no_peak_forecast()})
elif getattr(self, "_peak_fc_fault", None) is not None:
out.append({"ok": False, "warn": True, "id": "peak_forecast",
"text": messages.row_peak_forecast_unit(
self._peak_fc_fault)})
# OPT-17: a forecast summed from several entities names, by position,
# each member with no usable reading. A caution: control goes on.
gaps = getattr(self, "solar_fc_gaps", ())
+21
View File
@@ -788,6 +788,25 @@ def row_no_peak_forecast() -> str:
"the peak limit")
def peak_forecast_unit(unit, lang="en") -> str:
"""SAFETY-118. The 15-minute demand forecast has a number but no power
unit, so it is not used. `unit` is "" for none. One sentence, for the log
line, the status row and the settings page. Log lines stay English."""
if lang == "nl":
return ("De kwartierprognose heeft geen eenheid, dus ze wordt niet "
"gebruikt." if not unit else
"De kwartierprognose heeft geen vermogenseenheid, dus ze "
"wordt niet gebruikt.")
return ("The 15-minute demand forecast has no unit, so it is not used."
if not unit else
"The 15-minute demand forecast is not in a power unit, so it is "
"not used.")
def row_peak_forecast_unit(unit) -> str:
return peak_forecast_unit(unit)
def row_peak_guard_waiting() -> str:
return "Peak guard: no decision yet, control has not run"
@@ -1229,6 +1248,8 @@ def status_samples() -> list:
("row_no_estop", AMBER, row_no_estop()),
("row_estop_fitted", GREEN, row_estop_fitted()),
("row_no_peak_forecast", AMBER, row_no_peak_forecast()),
("row_peak_forecast_unit", AMBER, row_peak_forecast_unit("")),
("row_peak_forecast_unit", AMBER, row_peak_forecast_unit("kWh")),
("row_peak_guard_waiting", AMBER, row_peak_guard_waiting()),
("row_pv", GREEN, row_pv(3200, 2)),
("row_pv", GREEN, row_pv(1800, 1, True)),
+24 -6
View File
@@ -93,12 +93,12 @@ def watts(state: dict | None) -> tuple:
unknown" are different claims and the page has to be able to make the first.
⚠️ THE UNIT IS READ OFF THE ENTITY AND NOT ASSUMED, AND THERE IS NO
MAGNITUDE HEURISTIC. `read_inputs()` guesses kW-or-W for
`peak_forecast_entity` with `abs(raw) < 50`, which is safe there because
nobody's quarter-hour demand forecast is 50 W. It is NOT safe here: 30 W of
real production at dusk is an ordinary reading, and that heuristic would
publish it as 30 kW - a fabricated number, in the channel whose entire
purpose is to be believed a week later. A sensor whose unit this cannot read
MAGNITUDE HEURISTIC. 30 W of real production at dusk is an ordinary reading,
and a "small number means kW" rule would publish it as 30 kW - a fabricated
number, in the channel whose entire purpose is to be believed a week later.
SAFETY-118 removed the last such rule, on `peak_forecast_entity`, for the
same reason (DECISIONS/SAFETY-118-peak-forecast-unit.md): the peak forecast
now reads through this function too. A sensor whose unit this cannot read
is REFUSED rather than guessed at.
"""
if state is None:
@@ -126,6 +126,24 @@ def watts(state: dict | None) -> tuple:
return value * WATTS_PER[unit], unit
def unit_fault(state: dict | None):
"""SAFETY-118. `None` unless `state` holds a number whose unit cannot be
read in watts, then that unit (`""` for none). A missing, unavailable or
non-numeric state is a missing reading, not a unit fault, so it is `None`.
"""
if state is None:
return None
raw = str(state.get("state", "")).strip()
if raw.lower() in BAD_STATES:
return None
try:
float(raw)
except ValueError:
return None
unit = str((state.get("attributes") or {}).get(UNIT_KEY) or "").strip()
return None if unit in WATTS_PER else unit
# --- TEL-12: the ROSTER, and the SITE figure over it --------------------------
def entities(opts: dict) -> tuple:
+1 -1
View File
@@ -194,7 +194,7 @@ GROUPS = (
Field("peak_cap_w", SLIDER, "kW", scale=1000, step=100,
simple=True, wizard=5, note="month_peak"),
Field("peak_margin_w", SLIDER, "W", step=10), # SAFETY-79
Field("peak_forecast_entity", ENTITY, kind="power_w", wizard=5),
Field("peak_forecast_entity", ENTITY, kind="power", wizard=5),
Field("peak_soc_floor", LOCKED, "%"),
)),
Part("start", (
+7 -2
View File
@@ -1741,11 +1741,12 @@ def _card_note(option: str, spec) -> str:
# UX-13: entity options whose number the add-on takes as watts, with no unit
# conversion. pv.py converts each solar entity's own unit, so those are not here.
# conversion. pv.py converts each solar entity's own unit, so those are not here,
# and SAFETY-118 moved the peak forecast there too.
WATT_ENTITY_KEYS = (
"meter_entity", "p1_net_entity", "p1_import_entity", "p1_export_entity",
"p1_phase_net_entities", "p1_phase_import_entities",
"p1_phase_export_entities", "batt_entity", "peak_forecast_entity")
"p1_phase_export_entities", "batt_entity")
# The meter entities each `meter_source` reads through Home Assistant.
@@ -1829,6 +1830,10 @@ def _entity_notes(notes, opts: dict, entities: dict, bad=()) -> None:
_advise(notes, "warn", (key,),
f"{entity} reads in {unit}, but {S(key, where)} is "
"taken as watts, so pick a sensor in W.")
if key == "peak_forecast_entity" and unit not in pv.WATTS_PER:
_advise(notes, "warn", (key,),
messages.peak_forecast_unit(unit) + " Pick a sensor in "
"W or kW.")
if key in FORECAST_KEYS and unit not in solarfc.KWH_PER:
_advise(notes, "warn", (key,),
f"{entity} does not read in kWh, so pick a solar "
+303
View File
@@ -0,0 +1,303 @@
"""SAFETY-118: the peak forecast is read in its own unit. `python3 -B test_safety118.py`
`peak_forecast_entity` used to be read as a bare number and anything under 50
was multiplied by 1000, so a W sensor reading 17 W was taken as 17 kW. It is
now read through `pv.watts()` by its own `unit_of_measurement`. No unit, or a
unit that is not power: the forecast is not used, as if the option were empty.
1. The reader through the real `read_inputs()`: W, kW, MW, no unit, kWh, bad state.
2. The warning: once, again only when the cause changes, never every cycle.
3. One state read per cycle, as before.
4. The maintenance charge headroom and the charge-only clamp act on the
converted value (real `cycle()`).
5. The validator, the status row and the strings.
Mutating a module this file grades? Read MUTATION.md first (purge __pycache__).
"""
import asyncio
import logging
from pathlib import Path
from app import main as _main
from app import messages, pv, validate
from app.main import Controller
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def st(value, unit=None):
attrs = {} if unit is None else {"unit_of_measurement": unit}
return {"state": str(value), "attributes": attrs}
class _Store:
def __init__(self, data=None):
self.data = dict(data or {})
def set(self, k, v):
self.data[k] = v
def get_time(self, *a):
return None
def set_time(self, *a):
pass
class _Pub:
enabled = False
def publish(self, *a, **k):
pass
def close(self):
pass
class _Hass:
def __init__(self, fc=None, prices=None):
self.fc = fc
self.prices = prices or {}
self.reads = []
self.writes = []
async def limits(self, entity):
return (-5000.0, 5000.0, 1.0)
async def state(self, entity):
self.reads.append(entity)
if entity == "sensor.fc":
return self.fc
v = {"sensor.grid": 0.0, "sensor.soc": 50.0, "sensor.batt": 0.0,
**self.prices}.get(entity)
return None if v is None else st(v, "W")
async def number(self, entity, invert=False):
obj = await self.state(entity)
try:
return float(obj["state"]) if obj else None
except ValueError:
return None
async def set_number(self, entity, value):
self.writes.append(float(value))
return True
async def call(self, domain, service, data):
return True
OPTS = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "heartbeat_s": 10, "stale_input_s": 15,
"max_w": 5000.0, "gain": 0.6, "slew_w": 400.0, "deadband_w": 15,
"step_w": 10, "target_grid_w": -10.0, "stale_input_s": 15,
"peak_cap_w": 5000, "peak_margin_w": 0,
"peak_forecast_entity": "sensor.fc"}
class _Rec(logging.Handler):
def __init__(self):
super().__init__(logging.DEBUG)
self.rows = []
def emit(self, r):
self.rows.append((r.levelno, r.getMessage()))
def make(fc, store=None, prices=None, **over):
hass = _Hass(fc, prices)
c = Controller(dict(OPTS, **over), hass, _Store(store), _Pub(),
stop=asyncio.Event())
c.auto, c.dev_min, c.dev_max = True, -5000.0, 5000.0
return c, hass
def reads(c):
asyncio.run(c.read_inputs())
return c.peak_fc
def peak_of(state):
c, _h = make(state)
return reads(c)
print("1. the reader")
CASES = [("W 17", st(17, "W"), 17.0), ("W 820", st(820, "W"), 820.0),
("kW 0.82", st(0.82, "kW"), 820.0), ("kW 0.017", st(0.017, "kW"), 17.0),
("MW 0.0008", st(0.0008, "MW"), 800.0), ("W 49", st(49, "W"), 49.0),
("W 50", st(50, "W"), 50.0), ("kW 30", st(30, "kW"), 30000.0),
("W 0", st(0, "W"), 0.0)]
for label, s, want in CASES:
got = peak_of(s)
check(f"{label} -> {want} W (got {got})",
got is not None and abs(got - want) < 1e-6)
for label, s in [("no unit", st(820)), ("empty unit", st(820, "")),
("kWh", st(820, "kWh")), ("percent", st(20, "%")),
("unavailable", st("unavailable", "W")),
("unknown", st("unknown", "W")), ("missing entity", None),
("not a number", st("sunny", "W"))]:
check(f"{label} -> None (got {peak_of(s)})", peak_of(s) is None)
c, _h = make(st(820, "W"), peak_forecast_entity="")
check("option empty -> None and the entity is never read",
reads(c) is None and "sensor.fc" not in _h.reads)
print("2. the warning")
rec = _Rec()
lg = logging.getLogger("goodwe")
lg.addHandler(rec)
lg.setLevel(logging.DEBUG)
def warns():
return [m for lv, m in rec.rows if lv >= logging.WARNING]
c, h = make(st(820, "kWh"))
for _ in range(5):
reads(c)
check(f"kWh: five cycles, one WARNING ({warns()})", len(warns()) == 1)
check("...short, plain, and says it is not used",
warns()[0] == "The 15-minute demand forecast is not in a power unit, so "
"it is not used." and len(warns()[0].split()) <= 25)
h.fc = st(820, "MWh")
reads(c)
check("the same cause with another unit warns again (the cause changed)",
len(warns()) == 2)
h.fc = st(820)
reads(c)
check("no unit is a different cause and warns", len(warns()) == 3
and "has no unit" in warns()[2])
reads(c)
check("...and only once", len(warns()) == 3)
h.fc = st("unavailable")
reads(c)
check("unavailable is no unit fault and adds no warning", len(warns()) == 3)
h.fc = st(820, "W")
reads(c)
check("a good unit is read again and logs INFO, not a warning",
c.peak_fc == 820.0 and len(warns()) == 3
and rec.rows[-1] == (logging.INFO,
"The 15-minute demand forecast is used again."))
n = len(warns())
for s in (st(820, "W"), st(0.8, "kW")):
h.fc = s
reads(c)
check("W and kW never warn", len(warns()) == n)
rows = [r for r in c.checks() if r.get("id") == "peak_forecast"]
check("a good forecast has no peak_forecast row", not rows)
h.fc = st(820, "kWh")
reads(c)
rows = [r for r in c.checks() if r.get("id") == "peak_forecast"]
check("the status page carries a caution row for the unit fault",
len(rows) == 1 and rows[0]["warn"] and not rows[0]["ok"]
and rows[0]["text"] == messages.row_peak_forecast_unit("kWh"))
lg.removeHandler(rec)
print("3. one state read per cycle")
c, h = make(st(0.82, "kW"))
reads(c)
check(f"one read of the forecast entity per read_inputs() ({h.reads})",
h.reads.count("sensor.fc") == 1)
print("4. maintenance headroom and the charge-only clamp use watts")
seen = []
_real = _main.maintenance_charge_floor
def spy(charge_w, fc, cap):
out = _real(charge_w, fc, cap)
seen.append((charge_w, fc, cap, out))
return out
_main.maintenance_charge_floor = spy
try:
def cycle(fc, **kw):
c, h = make(fc, store={"phase": "charge"},
prices={"sensor.pnow": 1.0, "sensor.pavg": 2.0},
price_now_entity="sensor.pnow",
price_avg_entity="sensor.pavg", **kw)
seen.clear()
asyncio.run(c.read_inputs())
asyncio.run(c.cycle())
return c, h
# cap 2500 W, charge rate 2000 W: 820 W of forecast leaves 1680 W, 17 W
# leaves the whole 2000 W (the size rule read 17 as 17 kW and left 0).
c, h = cycle(st(0.82, "kW"), peak_cap_w=2500)
check(f"cheap-window headroom is cap - 820 W = 1680 W ({seen})",
len(seen) == 1 and seen[0][1] == 820.0 and seen[0][0] == 2000.0
and abs(seen[0][3] - 1680.0) < 1e-6)
c, h = cycle(st(17, "W"), peak_cap_w=2500)
check(f"a 17 W forecast leaves the full 2000 W charge rate ({seen})",
len(seen) == 1 and seen[0][1] == 17.0 and abs(seen[0][3] - 2000.0) < 1e-6)
# charge-only clamp: not cheap, shaping suspended only if the forecast is
# over the aim. 6 kW is over 5000 W; 17 W is not (the old rule read it
# as 17 kW and suspended).
def clamp(fc):
c, h = make(fc, store={"phase": "charge"})
asyncio.run(c.read_inputs())
asyncio.run(c.cycle())
return c._maint_shape_suspended
check("kW 6.0 (6000 W, over the 5000 W aim) suspends the charge-only clamp",
clamp(st(6.0, "kW")) is True)
check("W 17 leaves the charge-only clamp in place",
clamp(st(17, "W")) is False)
check("kW 0.017 leaves the charge-only clamp in place",
clamp(st(0.017, "kW")) is False)
check("no unit: forecast unused, clamp in place, as with the option empty",
clamp(st(6000)) is False)
finally:
_main.maintenance_charge_floor = _real
print("5. validator and strings")
def notes(unit, key="peak_forecast_entity"):
ent = {"sensor.fc": {"entity_id": "sensor.fc", "unit": unit,
"state": "1"}}
return [n for n in validate.config_notes(
{key: "sensor.fc", "meter_source": "off"}, entities=ent)
if key in n.keys]
check("validator: W no note", not notes("W"))
check("validator: kW no note", not notes("kW"))
check("validator: MW no note", not notes("MW"))
nu, kw = notes(""), notes("kWh")
check(f"validator: no unit warns ({nu})", len(nu) == 1 and nu[0].tier == "warn"
and "has no unit" in nu[0].text)
check(f"validator: kWh warns ({kw})", len(kw) == 1 and kw[0].tier == "warn"
and "not in a power unit" in kw[0].text)
check("validator: the false 'taken as watts' claim is gone for this entity",
not any("taken as watts" in n.text for n in nu + kw + notes("kW")))
check("validator: another watt key keeps its claim",
len(notes("kW", "batt_entity")) == 1
and "taken as watts" in notes("kW", "batt_entity")[0].text)
check("WATT_ENTITY_KEYS no longer holds the peak forecast",
"peak_forecast_entity" not in validate.WATT_ENTITY_KEYS
and "batt_entity" in validate.WATT_ENTITY_KEYS)
print(" EN no unit :", messages.peak_forecast_unit(""))
print(" EN bad unit:", messages.peak_forecast_unit("kWh"))
print(" NL no unit :", messages.peak_forecast_unit("", "nl"))
print(" NL bad unit:", messages.peak_forecast_unit("kWh", "nl"))
check("the strings differ by cause and by language",
len({messages.peak_forecast_unit(u, l) for u in ("", "kWh")
for l in ("en", "nl")}) == 4)
check("pv.unit_fault: None for a good unit and for a missing reading",
pv.unit_fault(st(1, "kW")) is None and pv.unit_fault(None) is None
and pv.unit_fault(st("unavailable")) is None
and pv.unit_fault(st(1)) == "" and pv.unit_fault(st(1, "kWh")) == "kWh")
src = (Path(__file__).parent / "app" / "main.py").read_text(encoding="utf-8")
check("the size rule is gone from main.py", "abs(raw) < 50" not in src)
print()
print("FAILED: " + "; ".join(fails) if fails else "all checks passed")
raise SystemExit(1 if fails else 0)
@@ -105,6 +105,13 @@ class _Hass:
return self.power(u)
return None
async def state(self, e):
"""SAFETY-118: the peak forecast is read as a state object; every
number this rig serves is in watts."""
v = await self.number(e)
return None if v is None else {
"state": str(v), "attributes": {"unit_of_measurement": "W"}}
async def set_number(self, e, v):
self.cmd[e[-1]] = float(v)
return True
+1 -1
View File
@@ -165,7 +165,7 @@ configuration:
description: "The add-on aims this much below the peak limit, so a 15-minute period that ends a little high still stays under it."
peak_forecast_entity:
name: "Limits · 15-minute demand forecast entity (W)"
description: "Optional. A forecast of this 15-minute period's average power. Leave it empty and there is no peak limit."
description: "Optional. A forecast of this 15-minute period's average power, in W or kW. With no power unit it is not used. Leave it empty and there is no peak limit."
peak_soc_floor:
name: "Limits · Peak reserve (%)"
description: "Peak limiting will not draw the battery below this level, but ordinary use can. Derived value, leave it unchanged."
+1 -1
View File
@@ -146,7 +146,7 @@ configuration:
description: "De add-on mikt zoveel onder de piekgrens, zodat een kwartier dat iets hoger uitvalt er toch onder blijft."
peak_forecast_entity:
name: "Grenzen · Entiteit kwartierprognose (W)"
description: "Optioneel. Een prognose van het gemiddelde vermogen in het lopende kwartier. Laat u dit leeg, dan is er geen piekgrens."
description: "Optioneel. Een prognose van het gemiddelde vermogen in het lopende kwartier, in W of kW. Zonder vermogenseenheid wordt ze niet gebruikt. Laat u dit leeg, dan is er geen piekgrens."
peak_soc_floor:
name: "Grenzen · Piekreserve (%)"
description: "De piekbeperking laat de batterij niet onder dit niveau zakken, gewoon verbruik wel. Afgeleide waarde, laat ze ongewijzigd."