diff --git a/goodwe_controller/CHANGELOG.md b/goodwe_controller/CHANGELOG.md index 679b372..b9316a5 100644 --- a/goodwe_controller/CHANGELOG.md +++ b/goodwe_controller/CHANGELOG.md @@ -1,5 +1,41 @@ # Changelog +## 0.15.0 + +**A minor bump: changed behaviour, and no option changes.** No option was +added, removed or renamed, and no default changed (83 options). Options that +start 0.14.0 also start 0.15.0. The changes below apply with one inverter and +with two. + +The add-on now learns and saves, per battery, what its power reading shows +at rest (`unit//idle_w`). It learns it after about two quiet minutes and +uses 0 W until then, as before. There is nothing to set. + +Contents of this release, in merge order since 0.14.0 (`02ed120`): + +| | | +|---|---| +| `cf705a9` | No more false "battery power reading stopped changing" errors at a new command after a rest, or at a change of phase. Each one paused control for a few seconds (several a day on a live site). A healthy battery that lags or turns around is no longer held as refusing for up to 15 min. With two inverters, a refusing battery whose reading at rest is about −100 W is now caught too. The rest value used is limited to ±75 W ([[SAFETY-94]], [[SAFETY-97]], also fixes [[SAFETY-58]]) | +| `3129dae` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-14]]) | + +### Known issues + +- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]). +- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]). +- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]). +- A battery whose reading at rest is beyond about ±170 W is still not caught when it refuses, as in 0.14.0 ([[SAFETY-97]]). +- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]). +- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]). +- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]). +- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]). + +### If you are crossing from a version older than 0.10.0 + +`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the +withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and +`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the +bare options (`jq '.data.options'`) first. + ## 0.14.0 **A minor bump: new behaviour with two inverters, and no option changes.** diff --git a/goodwe_controller/config.yaml b/goodwe_controller/config.yaml index 3c3104f..3faf4dc 100644 --- a/goodwe_controller/config.yaml +++ b/goodwe_controller/config.yaml @@ -1,5 +1,5 @@ name: GoodWe RS485 Controller -version: "0.14.0" +version: "0.15.0" slug: goodwe_controller description: >- Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart