UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG #140
@@ -1916,9 +1916,8 @@ class Controller:
|
||||
if (self.p1.stale and not self._meter_quiet_logged
|
||||
and self.p1.published_age_s > self.p1.max_age_s):
|
||||
self._meter_quiet_logged = True
|
||||
_LOG.warning("No meter reading for %s, over the limit of %s, "
|
||||
"so control waits and then sets the battery to "
|
||||
"0 W.", messages.seconds(self.p1.published_age_s),
|
||||
_LOG.warning("No meter reading for over %s, so control "
|
||||
"waits and then sets the battery to 0 W.",
|
||||
messages.seconds(self.p1.max_age_s))
|
||||
elif not self.p1.stale and self._meter_quiet_logged:
|
||||
self._meter_quiet_logged = False
|
||||
|
||||
@@ -877,7 +877,6 @@ DATA = {
|
||||
"main.py:messages.when(brussels(self.tariff_at))",
|
||||
"main.py:messages.duration(TARIFF_MAX_AGE_S)",
|
||||
"main.py:messages.count(len(targets), 'inverter')",
|
||||
"main.py:messages.seconds(self.p1.published_age_s)",
|
||||
"main.py:messages.seconds(self.p1.max_age_s)",
|
||||
# maintenance.py, mqtt.py, p1.py
|
||||
"maintenance.py:phase", "mqtt.py:err", "p1.py:err", "p1.py:self.host",
|
||||
@@ -1708,8 +1707,8 @@ _mq_info = [r.getMessage() for r in _mq if r.levelno == logging.INFO]
|
||||
check(f"a meter that goes quiet logs one WARNING per episode, not per cycle, "
|
||||
f"and one INFO when readings return ({_mq_warn}, {_mq_info})",
|
||||
len(_mq_warn) == 2 and _mq_info == ["Meter readings are back."]
|
||||
and _mq_warn[0].startswith("No meter reading for 40 seconds, over the "
|
||||
"limit of 30 seconds")
|
||||
and _mq_warn[0] == "No meter reading for over 30 seconds, so control "
|
||||
"waits and then sets the battery to 0 W."
|
||||
and len(words(_mq_warn[0])) <= LINE_WORDS)
|
||||
|
||||
# UX-11 item 1: a state file saved before UX-11 holds the long reasons, and
|
||||
|
||||
Reference in New Issue
Block a user