3 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5 6c980e87b0 DEPLOY-01: bump version to 0.3.0, changelog for SAFETY-04 and TEL-01
Fixes the version collision noticed while planning DEPLOY-01: release/1.0
still carried version 0.2.1, identical to what is already running on the
live system, so Home Assistant would not have offered the update at all.

- config.yaml: version 0.2.1 -> 0.3.0 (minor: TEL-01 adds a feature,
  SAFETY-04 changes the control law's internals)
- CHANGELOG.md: 0.3.0 entry for SAFETY-04 and TEL-01, in the existing voice

No code under app/ touched, no option defaults changed. Verified:
meter_source: off, integrator_max_w: 0, target_grid_w: -10 all unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 10:33:17 +02:00
glenn schrooyenandClaude Opus 5 505a847d85 TEL-01: P1 ingestion, with the derivation and the sample age the EMS owns
Evidence at sign-off: 122 checks in test_p1.py, 14 mutations all red with the
tree restored byte-identical, and an end-to-end run of the HA transport against
a fake Home Assistant websocket server with a real auth handshake. Age
semantics verified live rather than from fixtures - a real 2.2 s sleep with no
telegram arriving, age climbing 2.2004 s.

The deliverable that matters beyond this ticket is sensor.p1_sample_age_s:
recomputed against a monotonic clock and republished ~1 Hz rather than stamped
per telegram, so a meter frozen at a constant value - which pushes no state
change and therefore emits nothing - still shows an age that climbs. SAFETY-01's
firmware subscribes to it and trips on has_state() && state >= max_age_s.

Two blockers on the way, both of which would have shipped. With meter_source
off - the default, chosen for zero regression - the age was published anyway
and climbed without bound, which would have crossed max_age_s within half a
minute and pinned every installed inverter at 0 W. And a reconnect emitted a
synthetic sample that reset the age, hiding an outage from the watchdog that
exists to catch it, contradicting the module's own docstring while a test
asserted the violation.

Not verifiable without hardware, and not claimed: real DSMR entity ids and
units, whether a real P1 MQTT bridge matches the documented strict schema, the
0.35 s debounce against real telegram timing, and MQTT reconnect against a real
broker.

Known limits, both documented and filed as SAFETY-12: mqtt_p1 cannot detect a
frozen bridge that keeps republishing, and a value-frozen meter stops the
control loop cycling at all - the latter pre-existing and affecting the legacy
meter_entity path today.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-24 23:17:34 +02:00
glenn schrooyenandClaude Opus 5 f498d5fa54 SAFETY-04: bound the integrator independently of the output
Evidence at sign-off: 55 checks in test_control.py (24 on release/1.0),
independently reproduced. 108,031 failsafe-release combinations swept across
both grid directions, 2,500 randomised carried-i_w trajectories at 200 ticks,
300 repeated-meter-value stall scenarios - zero anomalies. The historical
runaway regression uses the real 10.3 numbers and goes red when the protection
is removed.

Two rejections on the way. The first cut deadlocked the loop at small |i_w| and
let the accumulator run 50% past the rail, which ADDED windup this codebase
never had - the accumulator used to be the post-clamp command, so it could not
exceed max_w by construction. The second deadlocked at i_w == 0.0 in the export
direction, found by sweeping the boundary after three reviewers had each
covered the same half of it.

The finding worth keeping: deleting the integrator freeze outright failed 0 of
55 checks, because the integrator bound truncated to exactly the value the
fixture asserted. A neighbouring mechanism was standing in for the one under
test. The same pattern turned up again in the output clamp. test_control.py now
carries the audit table and its invariant - every mechanism in compute() must
be noticed by at least two checks when deleted.

Deliberately not met as literally written: the detector counts cycles, not the
10 s the AC specifies. compute() is clockless and cycle() runs only on a
changed meter reading, so there is no wall-clock window at all. Documented in
the code and in DOCS.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-24 23:17:18 +02:00
2 changed files with 37 additions and 1 deletions
+36
View File
@@ -1,5 +1,41 @@
# Changelog
## 0.3.0
**SAFETY-04.** The control law's integrator is now an explicit accumulator,
bounded independently of the output clamp instead of inheriting whatever
headroom the clamp happened to leave. It also freezes while the inverter is
not tracking, rather than continuing to wind up against a command nothing is
acting on. `integrator_max_w` (default `0`) governs the bound; `0` means
"follow `max_w`", which is the existing behaviour.
Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep
against the previous control law confirms it decides identically at
`integrator_max_w: 0`.
**TEL-01.** P1 meter ingestion, so a Belgian P1's two unsigned registers
(consumption, injection) no longer need a hand-written signed template
sensor: the subtraction moves into the add-on, done once and tested. Two
transports, chosen with the new `meter_source` option: `ha_dsmr` subscribes
to the DSMR integration over the HA WebSocket, `mqtt_p1` reads a topic.
Defaults to `off`, which keeps the existing `meter_entity` path untouched -
nothing changes for an install that does not opt in.
Enabling it publishes `sensor.p1_sample_age_s`: seconds since the newest
accepted telegram, recomputed against the clock and republished roughly once
a second rather than only when a telegram lands. That is deliberate - Home
Assistant only pushes a state on change, so a meter sitting at a genuinely
constant reading would otherwise look identical to a dead one. Watching the
age instead means a frozen meter shows a climbing age, not a flat line. The
firmware watchdog subscribes to this exact entity id.
Known limits, both already in DOCS.md: on `mqtt_p1`, a bridge stuck
republishing its last telegram still "arrives", so the age cannot detect
that particular failure - prefer `ha_dsmr` where both are available. And a
dead P1 meter takes 45 s to reach 0 W commanded (30 s for `meter_max_age_s`
to call the reading stale, then 15 s of `stale_input_s` on top), which is
`meter_max_age_s` and `stale_input_s` stacking, not either one alone.
## 0.2.1
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.2.1"
version: "0.3.0"
slug: goodwe_controller
description: >-
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart