@@ -0,0 +1,10 @@
|
|||||||
|
# This add-on is deployed to a Linux container. core.autocrlf=true on the
|
||||||
|
# authoring box gave the checkout CRLF, so a plain copy shipped CRLF files -
|
||||||
|
# run.sh with CRLF is a "bad interpreter" failure, and any hash-based drift
|
||||||
|
# check between repo and deployment fails for a reason that has nothing to do
|
||||||
|
# with the code. Deploy with:
|
||||||
|
# git -c core.autocrlf=false archive release/1.0 goodwe_controller | tar -x
|
||||||
|
# which is how 0.3.0 went out, byte-identical to the blobs.
|
||||||
|
* text=auto eol=lf
|
||||||
|
*.png binary
|
||||||
|
*.gz binary
|
||||||
@@ -1,5 +1,41 @@
|
|||||||
# Changelog
|
# Changelog
|
||||||
|
|
||||||
|
## 0.3.0
|
||||||
|
|
||||||
|
**SAFETY-04.** The control law's integrator is now an explicit accumulator,
|
||||||
|
bounded independently of the output clamp instead of inheriting whatever
|
||||||
|
headroom the clamp happened to leave. It also freezes while the inverter is
|
||||||
|
not tracking, rather than continuing to wind up against a command nothing is
|
||||||
|
acting on. `integrator_max_w` (default `0`) governs the bound; `0` means
|
||||||
|
"follow `max_w`", which is the existing behaviour.
|
||||||
|
|
||||||
|
Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep
|
||||||
|
against the previous control law confirms it decides identically at
|
||||||
|
`integrator_max_w: 0`.
|
||||||
|
|
||||||
|
**TEL-01.** P1 meter ingestion, so a Belgian P1's two unsigned registers
|
||||||
|
(consumption, injection) no longer need a hand-written signed template
|
||||||
|
sensor: the subtraction moves into the add-on, done once and tested. Two
|
||||||
|
transports, chosen with the new `meter_source` option: `ha_dsmr` subscribes
|
||||||
|
to the DSMR integration over the HA WebSocket, `mqtt_p1` reads a topic.
|
||||||
|
Defaults to `off`, which keeps the existing `meter_entity` path untouched -
|
||||||
|
nothing changes for an install that does not opt in.
|
||||||
|
|
||||||
|
Enabling it publishes `sensor.p1_sample_age_s`: seconds since the newest
|
||||||
|
accepted telegram, recomputed against the clock and republished roughly once
|
||||||
|
a second rather than only when a telegram lands. That is deliberate - Home
|
||||||
|
Assistant only pushes a state on change, so a meter sitting at a genuinely
|
||||||
|
constant reading would otherwise look identical to a dead one. Watching the
|
||||||
|
age instead means a frozen meter shows a climbing age, not a flat line. The
|
||||||
|
firmware watchdog subscribes to this exact entity id.
|
||||||
|
|
||||||
|
Known limits, both already in DOCS.md: on `mqtt_p1`, a bridge stuck
|
||||||
|
republishing its last telegram still "arrives", so the age cannot detect
|
||||||
|
that particular failure - prefer `ha_dsmr` where both are available. And a
|
||||||
|
dead P1 meter takes 45 s to reach 0 W commanded (30 s for `meter_max_age_s`
|
||||||
|
to call the reading stale, then 15 s of `stale_input_s` on top), which is
|
||||||
|
`meter_max_age_s` and `stale_input_s` stacking, not either one alone.
|
||||||
|
|
||||||
## 0.2.1
|
## 0.2.1
|
||||||
|
|
||||||
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
|
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
name: GoodWe RS485 Controller
|
name: GoodWe RS485 Controller
|
||||||
version: "0.2.1"
|
version: "0.3.0"
|
||||||
slug: goodwe_controller
|
slug: goodwe_controller
|
||||||
description: >-
|
description: >-
|
||||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||||
|
|||||||
Reference in New Issue