Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
d57122ec74 | ||
|
|
4601682815 | ||
|
|
9234016419 | ||
|
|
b7272169b1 | ||
|
|
2b8b8cb97f | ||
|
|
8e589fee3f | ||
|
|
a1376e44e4 | ||
|
|
e709554857 |
@@ -2,6 +2,126 @@
|
|||||||
|
|
||||||
## Unreleased
|
## Unreleased
|
||||||
|
|
||||||
|
**OPT-04's AC4 is met: twelve months of real EPEX BE day-ahead prices are now in
|
||||||
|
the repository, and the strategy has been replayed against them (DATA-02).**
|
||||||
|
AC4 asked for "net-positive across 12 months of replayed prices". OPT-04 shipped
|
||||||
|
it as NOT MET and replayed a synthetic year instead, because `scenarios/` held
|
||||||
|
only P1 meter captures. That was the right call at the time and the wrong
|
||||||
|
diagnosis of why: the criterion was being carried alongside a 30-day *meter*
|
||||||
|
criterion as though both needed waiting, and EPEX BE day-ahead is **public data,
|
||||||
|
not a capture**. It needed a fetch, not a month.
|
||||||
|
|
||||||
|
`scenarios/epex-be-dayahead-2025-09-01_2026-09-01.json` — **8760 hourly points**,
|
||||||
|
2025-09-01 to 2026-09-01 Brussels-local, in §9.3's canonical three-field shape.
|
||||||
|
`scenarios/fetch_epex_be.py` produced it and `--verify` re-derives every claim it
|
||||||
|
makes about itself without touching the network.
|
||||||
|
|
||||||
|
**Licensing was checked before anything was committed.** The source is
|
||||||
|
Fraunhofer ISE's Energy-Charts API, which publishes the **BE** zone under
|
||||||
|
**CC BY 4.0 from Bundesnetzagentur | SMARD.de** and other zones under
|
||||||
|
private-use-only terms — so this zone is redistributable with attribution and the
|
||||||
|
data is committed rather than left as a script plus a checksum. The fetcher
|
||||||
|
**refuses to write a file** whose per-response `license_info` stops saying
|
||||||
|
CC BY 4.0. Cross-checked against the upstream: SMARD's own `4996/DE` series
|
||||||
|
matched this feed on all 96 quarter-hours of 2026-04-10, maximum difference
|
||||||
|
0.00 EUR/MWh.
|
||||||
|
|
||||||
|
**The figures are raw wholesale and the file says so.** `"all_in": false`, with
|
||||||
|
the markup/tax assumption carried in `provenance.all_in_assumption` as *numbers
|
||||||
|
to apply* rather than numbers already applied — TARIFF-02's double-counting trap
|
||||||
|
in data form. `test_arbitrage.py` section 7B applies it in one visible place and
|
||||||
|
**asserts arithmetically** that its two additive terms cancel out of every daily
|
||||||
|
spread, so the trade counts depend on the VAT multiplier alone and not on the
|
||||||
|
guessed markup. The same replay is run on raw wholesale as well, so how much of
|
||||||
|
the answer rests on the guess is reported (110 trades all-in, 88 raw).
|
||||||
|
|
||||||
|
**DST is handled by construction, not by a special case.** The fetcher iterates
|
||||||
|
in UTC and renders through `price.brussels()`, so **2025-10-26 comes out 25
|
||||||
|
points and 2026-03-29 comes out 23** — verified by counting per Brussels day
|
||||||
|
rather than asserting 24, and by checking that October's 02:00 appears twice at
|
||||||
|
`+02:00` and `+01:00` with two different prices while March's 02:00 does not
|
||||||
|
appear at all. The window is bounded at *local* midnight: bounding it at 00:00
|
||||||
|
UTC produced a 22-hour first day, and a 24-hour day silently missing from the
|
||||||
|
end, both of which the point-and-gap accounting caught.
|
||||||
|
|
||||||
|
**The result, at the shipped default, whatever it is.** At
|
||||||
|
`cycle_cost_threshold_eur` **0.10** widened by FCST-03's no-weather **1.5×** to a
|
||||||
|
required 0.1500 EUR/kWh, the real year completes **110 round trips** and is
|
||||||
|
**net-positive at +24.88 EUR** of benefit net of the cycle cost (2 kWh a trade).
|
||||||
|
Unwidened it completes 173. **Nothing was tuned:** the shipped default and the
|
||||||
|
2.5/1.5 factors are untouched, and every figure comes out of the same `decide()`.
|
||||||
|
|
||||||
|
**What the product owner's open decision now has under it.** The four
|
||||||
|
independent reports that a static day/night spread of ~0.0840 does not clear
|
||||||
|
0.10 **all stand** — a static-tariff site still never trades. What was missing
|
||||||
|
was the other half: a *dynamic* site's daily spread clears the widened
|
||||||
|
requirement on **121 of 365 days**, median daily all-in spread **0.1130**. The
|
||||||
|
threshold at which a median day would clear is **0.0754**, and at that value the
|
||||||
|
same year completes 156 trips for +35.42 EUR. Both numbers are reported; neither
|
||||||
|
is applied.
|
||||||
|
|
||||||
|
**And the synthetic year stays, because the real one cannot grade §17.** Not one
|
||||||
|
of the 365 real days has a negative *dearest* hour — 372 negative wholesale hours
|
||||||
|
and 0 days where the strategy would have sold into one — so "0 discharges into a
|
||||||
|
negative-price hour" over real prices is a count of something that could not
|
||||||
|
happen, and deleting the guard would not change it. Section 7B asserts that
|
||||||
|
degeneracy instead of quietly reporting the zero; section 7's generator is still
|
||||||
|
the only thing here that puts a negative price where the strategy would sell.
|
||||||
|
|
||||||
|
**Size, measured rather than assumed.** Plain JSON: 893 KB in the working tree
|
||||||
|
but **74.6 KB as a git object**, against 56.5 KB for a committed `.json.gz`. Git
|
||||||
|
already compresses blobs, so gzipping saves 18 KB and costs a reviewer the
|
||||||
|
ability to read the provenance block — including the licence claim they are
|
||||||
|
meant to check — in the diff. Plain, and `load()` still accepts `.gz` for a
|
||||||
|
future dataset that earns it.
|
||||||
|
|
||||||
|
**Nothing is wired into the add-on.** `generic_dayahead` remains the live fetch
|
||||||
|
path; nothing under `app/` imports the script, and the dataset is for replay.
|
||||||
|
|
||||||
|
**The capacity-peak guard's forced discharge now has an EMS-side energy floor
|
||||||
|
(SAFETY-24).** SAFETY-07 can command a discharge to hold a billed quarter down,
|
||||||
|
and nothing below it consulted the state of charge — `soc_floor` belongs to the
|
||||||
|
maintenance cycle, and freeze.py already recorded that for the grid-following
|
||||||
|
loop "the BMS is the sole energy backstop". On the 2026-08-20 replay the guard
|
||||||
|
asks for **878 Wh in a day**. Relying on the BMS is not absurd — it is a real
|
||||||
|
floor and it works — but it is the pack's protection rather than the operator's,
|
||||||
|
and a month of aggressive quarters leaves the battery repeatedly at that cut-out
|
||||||
|
with no EMS-side record of why.
|
||||||
|
|
||||||
|
`decide()` now takes `soc` and `soc_floor`, both **required** and neither
|
||||||
|
defaulted. Above the floor nothing changes. At or below it the guard files a
|
||||||
|
**0 W** floor instead of a sized one — one-directional, so charging stays blocked
|
||||||
|
and no discharge is capped — and reports `floor_limited` with the reason it
|
||||||
|
bound. It is not a trip: every stop in §11.2's table still outranks the claim,
|
||||||
|
and the floor can never be negative, so §9.1's "discharge and export are never
|
||||||
|
capped by the peak guard" survives as a property of the object (swept: 0 negative
|
||||||
|
floors across 1296 combinations of load, elapsed, battery, SoC and floor).
|
||||||
|
|
||||||
|
**Failing to shave is not silent.** A floor-limited cycle raises one notification
|
||||||
|
per episode (`goodwe_peak_soc_floor`), distinct from the saturation alarm because
|
||||||
|
the two ask the operator for opposite things, and renders its own status row.
|
||||||
|
An **unreadable SoC is floor-limited, not a full battery** — a full battery is
|
||||||
|
exactly the value that would disarm the floor, and this project has shipped that
|
||||||
|
defaulting once before (`| float(100)` in the stage-5 loop).
|
||||||
|
|
||||||
|
**Verified by replay, not by argument.** The 2026-08-20 capture is driven against
|
||||||
|
a modelled pack sized from the day's own measured appetite, so it genuinely
|
||||||
|
exhausts: without the floor it reaches the BMS cut-out and sits there for 1227
|
||||||
|
guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The
|
||||||
|
energy withheld equals the energy between the two floors to within one cycle at
|
||||||
|
the rail. The honest half is reported too — the worst quarter goes from 4338 W to
|
||||||
|
5030 W, because a floor-limited guard shaves less on purpose.
|
||||||
|
|
||||||
|
**Two new options, mirrored once.** `peak_soc_floor` (20) and `bms_soc_floor`
|
||||||
|
(10), whose defaults live in `peakguard.PEAK_OPTION_DEFAULTS` — TARIFF-02's
|
||||||
|
pattern — imported by `validate.py` and `main.py` rather than typed as literals,
|
||||||
|
and pinned to `config.yaml` by a check that reads the file. CFG-03 still tracks
|
||||||
|
three places. `validate.py` rule 8 refuses `peak_soc_floor <= bms_soc_floor` at
|
||||||
|
startup, in CFG-01/MAINT-04's manner. `maintenance_soc_floor` is deliberately
|
||||||
|
**not** reused and deliberately **not** renamed: it is a drain target, not a
|
||||||
|
spend limit, and the rename is recorded as a decision to revisit if a third
|
||||||
|
floor ever appears.
|
||||||
|
|
||||||
**Price arbitrage - the first strategy that trades on a price (OPT-04).**
|
**Price arbitrage - the first strategy that trades on a price (OPT-04).**
|
||||||
Four cards built the price stack and nothing traded on it. `app/arbitrage.py`
|
Four cards built the price stack and nothing traded on it. `app/arbitrage.py`
|
||||||
is §10.1's priority 3: charge in the cheapest published hour, discharge in the
|
is §10.1's priority 3: charge in the cheapest published hour, discharge in the
|
||||||
|
|||||||
@@ -420,7 +420,7 @@ help - see "Why the tuning is what it is".
|
|||||||
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
|
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
|
||||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||||
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
|
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
|
||||||
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor |
|
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor. ⚠️ **This is not `peak_soc_floor`.** It is the depth the monthly recalibration deliberately goes to, once, on purpose; `peak_soc_floor` is the depth a money-saving discharge may never reach on any day. The right values differ (11 vs 20 as shipped), which is why they are two keys |
|
||||||
| `maintenance_soc_target` | 99 | Charge target |
|
| `maintenance_soc_target` | 99 | Charge target |
|
||||||
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
|
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
|
||||||
|
|
||||||
@@ -430,6 +430,8 @@ help - see "Why the tuning is what it is".
|
|||||||
|---|---|
|
|---|---|
|
||||||
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Empty = no cap |
|
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Empty = no cap |
|
||||||
| `peak_cap_w` | The site's capacity-tariff target |
|
| `peak_cap_w` | The site's capacity-tariff target |
|
||||||
|
| `peak_soc_floor` (20) | **The percent below which the capacity-peak guard will not discharge the battery.** Not optional and not the same thing as `maintenance_soc_floor` — see below |
|
||||||
|
| `bms_soc_floor` (10) | The pack's **own** cut-out percent, the number the BMS enforces whatever you set above. `peak_soc_floor` must be **strictly above** it or the add-on refuses to start |
|
||||||
| `price_now_entity`, `price_avg_entity` | Dynamic tariff. Empty = never force a paid grid top-up |
|
| `price_now_entity`, `price_avg_entity` | Dynamic tariff. Empty = never force a paid grid top-up |
|
||||||
|
|
||||||
On a capacity-tariff site the maintenance charge is capped by the headroom left
|
On a capacity-tariff site the maintenance charge is capped by the headroom left
|
||||||
@@ -530,11 +532,46 @@ projected over — raises one notification (`goodwe_peak_saturated`), because th
|
|||||||
is the one state where the money will be spent and shedding load is the only
|
is the one state where the money will be spent and shedding load is the only
|
||||||
thing left that changes the bill.
|
thing left that changes the bill.
|
||||||
|
|
||||||
**No new option.** The ceiling is `peak_cap_w`, which already shipped. The
|
**No new option for the CEILING.** It is `peak_cap_w`, which already shipped. The
|
||||||
coverage threshold is `meter_max_age_s`, the freeze predicate is
|
coverage threshold is `meter_max_age_s`, the freeze predicate is
|
||||||
`meter_freeze_s`, and the achievable discharge comes from `max_w` and the device
|
`meter_freeze_s`, and the achievable discharge comes from `max_w` and the device
|
||||||
rating — every one of them a key that already exists.
|
rating — every one of them a key that already exists.
|
||||||
|
|
||||||
|
#### The energy floor under the forced discharge (`peak_soc_floor`)
|
||||||
|
|
||||||
|
The guard above can **command a discharge**, and until SAFETY-24 nothing in the
|
||||||
|
add-on bounded how far down it took the pack — the BMS was the only backstop.
|
||||||
|
On the 2026-08-20 replay the guard asks for **878 Wh in a day**.
|
||||||
|
|
||||||
|
That is not absurd: the BMS floor is real and it works. But it is *the pack's*
|
||||||
|
protection, not *yours*. A month of aggressive quarters can leave the battery
|
||||||
|
repeatedly parked at that cut-out with no record on this side of why, and the
|
||||||
|
first symptom — a battery that is never available when you want it — looks
|
||||||
|
exactly like the SoC drift the monthly maintenance cycle exists to correct.
|
||||||
|
|
||||||
|
- **`peak_soc_floor` (20 %)** is where the forced discharge stops. Below it the
|
||||||
|
guard files a **0 W** floor instead of a sized one: charging stays blocked
|
||||||
|
(that can only ever lower your offtake), and no further discharge is asked for.
|
||||||
|
- **It does not stop the ordinary self-consumption loop.** That loop still has no
|
||||||
|
SoC guard of its own. This bounds what the *peak guard* spends for money.
|
||||||
|
- **When it binds you are told**, once per episode, with notification
|
||||||
|
`goodwe_peak_soc_floor` and a status-page row reading `PEAK GUARD
|
||||||
|
FLOOR-LIMITED`: the quarter **will** go over the ceiling, so shedding load is
|
||||||
|
the only thing left that changes the bill. Failing to shave is never silent —
|
||||||
|
the euro figure is the whole point of the guard.
|
||||||
|
- **An unreadable SoC is treated as floor-limited, not as a full battery.** A
|
||||||
|
full battery is exactly the value that would disarm this floor.
|
||||||
|
- **`bms_soc_floor` (10 %)** is the pack's own cut-out — register `0x0560` on the
|
||||||
|
reference GW5000S-BP, consistent with DoD 90. It exists so the add-on can
|
||||||
|
**refuse to start** when `peak_soc_floor` is at or below it: such a floor can
|
||||||
|
never be the thing that stops the discharge, and a guard that advertises a
|
||||||
|
backstop it does not have is the one thing this project will not ship. Equal is
|
||||||
|
refused too — equal buys zero margin.
|
||||||
|
|
||||||
|
Why 20 %: the reference pack is 13.8 kWh usable, so 10 points of margin over the
|
||||||
|
BMS cut-out is about 1.6× the guard's worst measured day. If your pack is
|
||||||
|
smaller, or your quarters are worse, raise it.
|
||||||
|
|
||||||
### The winding-loop alarm (the output clamp)
|
### The winding-loop alarm (the output clamp)
|
||||||
|
|
||||||
Every setpoint this add-on writes is clamped to `max_w` before it leaves the
|
Every setpoint this add-on writes is clamped to `max_w` before it leaves the
|
||||||
|
|||||||
@@ -229,14 +229,25 @@ class Controller:
|
|||||||
# the action log and the notification fire on transitions rather than
|
# the action log and the notification fire on transitions rather than
|
||||||
# once per cycle for a quarter of an hour.
|
# once per cycle for a quarter of an hour.
|
||||||
#
|
#
|
||||||
# ⚠️ NO CONFIG OF ITS OWN, for the reason the clamp watchdog gives ~90
|
# ⚠️ THE CEILING HAS NO CONFIG OF ITS OWN, for the reason the clamp
|
||||||
# lines up and TARIFF-01 repeats: the ceiling is `peak_cap_w`, already
|
# watchdog gives ~90 lines up and TARIFF-01 repeats: it is `peak_cap_w`,
|
||||||
# shipped and already validated, and every other term is read off
|
# already shipped and already validated, and every other term of the
|
||||||
# something the arbiter or the averager already owns. CFG-03 still
|
# projection is read off something the arbiter or the averager already
|
||||||
# tracks three places, not four.
|
# owns.
|
||||||
|
#
|
||||||
|
# ⚠️ SAFETY-24'S FLOOR DOES HAVE ONE, AND IT COULD NOT NOT HAVE. How far
|
||||||
|
# down the guard may spend the pack for money is a number only the site
|
||||||
|
# knows, and refusing one set below the pack's own cut-out means knowing
|
||||||
|
# that cut-out too. So this card adds exactly two keys and reads their
|
||||||
|
# defaults from `peakguard.PEAK_OPTION_DEFAULTS` - TARIFF-02's mirror
|
||||||
|
# pattern - rather than typing literals here. THAT is what keeps CFG-03
|
||||||
|
# at three places: the divergence validate.py's rule 6 documents
|
||||||
|
# (`maintenance_charge_w` 2000 there, 2500 here) is exactly what a
|
||||||
|
# literal in this file would repeat.
|
||||||
self.peak_guard = None
|
self.peak_guard = None
|
||||||
self._peak_engaged = False
|
self._peak_engaged = False
|
||||||
self._peak_saturated = False
|
self._peak_saturated = False
|
||||||
|
self._peak_floor_limited = False
|
||||||
self._maint_shape_suspended = False
|
self._maint_shape_suspended = False
|
||||||
# Set by amain() once the transport is built, so the status page can show
|
# Set by amain() once the transport is built, so the status page can show
|
||||||
# what only the transport knows (homewizard_local's unchanged_s). Stays
|
# what only the transport knows (homewizard_local's unchanged_s). Stays
|
||||||
@@ -534,6 +545,17 @@ class Controller:
|
|||||||
cap_w=float(self.o.get("peak_cap_w", 3500)),
|
cap_w=float(self.o.get("peak_cap_w", 3500)),
|
||||||
reading=self.peak.peak(now),
|
reading=self.peak.peak(now),
|
||||||
achievable_w=min(max_w, abs(float(dev_top))),
|
achievable_w=min(max_w, abs(float(dev_top))),
|
||||||
|
# ⚠️ SAFETY-24. `self.soc` IS THE MEASURED READING AND MAY BE None,
|
||||||
|
# and it is handed over as None rather than defaulted here. An early
|
||||||
|
# draft of the stage-5 loop read SoC as `| float(100)` and thereby
|
||||||
|
# invented a full battery (NOTES.md 4.4b); a full battery is
|
||||||
|
# precisely the value that disarms this floor. decide() treats None
|
||||||
|
# as floor-limited, which is the direction that costs a shave rather
|
||||||
|
# than the pack.
|
||||||
|
soc=self.soc,
|
||||||
|
soc_floor=float(self.o.get(
|
||||||
|
"peak_soc_floor",
|
||||||
|
peakguard.PEAK_OPTION_DEFAULTS["peak_soc_floor"])),
|
||||||
max_hold_s=self.p1.averager.max_hold_s,
|
max_hold_s=self.p1.averager.max_hold_s,
|
||||||
frozen=looks_frozen(getattr(self.p1_source, "unchanged_s", None),
|
frozen=looks_frozen(getattr(self.p1_source, "unchanged_s", None),
|
||||||
standing, max_w, self.freeze_wd.cfg),
|
standing, max_w, self.freeze_wd.cfg),
|
||||||
@@ -780,6 +802,16 @@ class Controller:
|
|||||||
# method assigned above and nothing since has touched.
|
# method assigned above and nothing since has touched.
|
||||||
await self.check_peak_saturated()
|
await self.check_peak_saturated()
|
||||||
|
|
||||||
|
# --- SAFETY-24's alarm, and it is the OTHER way the money gets spent --
|
||||||
|
# Same boundary argument as check_peak_saturated(): it grades
|
||||||
|
# `self.peak_guard`, which cycle() assigned above and nothing since has
|
||||||
|
# touched. Kept as its own method rather than folded into that one,
|
||||||
|
# because the two states are mutually exclusive and want OPPOSITE
|
||||||
|
# operator actions - saturation says "shed load, the inverter is already
|
||||||
|
# flat out"; this says "the pack is at its floor and this quarter is not
|
||||||
|
# being shaved at all".
|
||||||
|
await self.check_peak_floor_limited()
|
||||||
|
|
||||||
# --- TARIFF-01, and it is LAST on purpose -----------------------------
|
# --- TARIFF-01, and it is LAST on purpose -----------------------------
|
||||||
# Banking a quarter is bookkeeping about a moment that has already
|
# Banking a quarter is bookkeeping about a moment that has already
|
||||||
# happened; a slow SD card must never sit between the meter and the
|
# happened; a slow SD card must never sit between the meter and the
|
||||||
@@ -924,6 +956,70 @@ class Controller:
|
|||||||
f"thing that changes the bill."),
|
f"thing that changes the bill."),
|
||||||
})
|
})
|
||||||
|
|
||||||
|
async def check_peak_floor_limited(self) -> None:
|
||||||
|
"""SAFETY-24. Alarm when the EMS SoC floor stops the guard shaving.
|
||||||
|
|
||||||
|
⚠️ FAILING TO SHAVE MUST NOT BE SILENT, AND THAT IS THE WHOLE POINT.
|
||||||
|
The guard exists for one euro figure - the capaciteitstarief bills the
|
||||||
|
month's single worst quarter - so a cycle in which it CHOSE not to shave
|
||||||
|
is a cycle in which money is being spent on purpose. Under-shaving
|
||||||
|
quietly would leave the operator with a bill and a status page full of
|
||||||
|
green.
|
||||||
|
|
||||||
|
The distinction from check_peak_saturated() is the operator's action,
|
||||||
|
which is why these are two notifications and not one:
|
||||||
|
|
||||||
|
saturated the guard asked for everything the inverter has and it
|
||||||
|
was not enough. SHED LOAD - the controller has already
|
||||||
|
done all it can, and it is still discharging.
|
||||||
|
floor-limited the guard asked for NOTHING, because the pack is at or
|
||||||
|
under the EMS floor, or its SoC could not be read.
|
||||||
|
Nothing is being discharged for this quarter at all.
|
||||||
|
|
||||||
|
They cannot both be true: peakguard.decide()'s floor-limited branch
|
||||||
|
returns before the `achievable_w` clamp that sets `saturated`.
|
||||||
|
|
||||||
|
Edge-triggered, and de-asserting arms it again - FreezeWatchdog's shape,
|
||||||
|
for FreezeWatchdog's reason: one notification per episode, not one per
|
||||||
|
cycle for a quarter of an hour.
|
||||||
|
"""
|
||||||
|
g = self.peak_guard
|
||||||
|
limited = bool(g is not None and g.floor_limited)
|
||||||
|
was, self._peak_floor_limited = self._peak_floor_limited, limited
|
||||||
|
if not limited or was:
|
||||||
|
return
|
||||||
|
# No prefix: `reason` already opens with PEAK GUARD FLOOR-LIMITED, and
|
||||||
|
# a second copy is the kind of stutter that makes a 40-line action log
|
||||||
|
# read like boilerplate. The saturated path needs its prefix because its
|
||||||
|
# reason carries the word in the middle of a sentence, not at the front.
|
||||||
|
self.log_event(g.reason)
|
||||||
|
_LOG.error(
|
||||||
|
"SAFETY-24 - %s. The controller is STILL RUNNING and charging is "
|
||||||
|
"still blocked, but it is not discharging to hold this quarter, so "
|
||||||
|
"the quarter will set or raise the month's billed capacity peak. "
|
||||||
|
"Shed load, or lower peak_soc_floor if this pack can afford it.",
|
||||||
|
g.reason)
|
||||||
|
# A fixed notification_id, and a DIFFERENT one from every other alarm
|
||||||
|
# here - check_meter_frozen() gives the reasoning. A battery at its
|
||||||
|
# energy floor is not a saturated inverter and is not a frozen meter,
|
||||||
|
# and an operator who has to dismiss three identical-looking cards
|
||||||
|
# learns to dismiss the one that mattered.
|
||||||
|
await self.hass.call("persistent_notification", "create", {
|
||||||
|
"notification_id": "goodwe_peak_soc_floor",
|
||||||
|
"title": "GoodWe: the capacity-peak guard has run out of battery",
|
||||||
|
"message": (
|
||||||
|
f"{g.reason}.\n\nTHIS QUARTER WILL GO OVER THE "
|
||||||
|
f"{g.ceiling_w:.0f} W ceiling and will set or raise the "
|
||||||
|
f"month's billed capaciteitstarief peak, because the peak guard "
|
||||||
|
f"is not allowed to discharge any further: {g.soc_floor_reason}."
|
||||||
|
f" This is not a controller fault - it is the EMS-side energy "
|
||||||
|
f"floor (peak_soc_floor) doing what it is set to do, and it sits "
|
||||||
|
f"deliberately above the pack's own BMS cut-out. Charging stays "
|
||||||
|
f"blocked. Shedding load is the only thing that changes the bill "
|
||||||
|
f"now; if this pack can afford a deeper discharge, lower "
|
||||||
|
f"peak_soc_floor."),
|
||||||
|
})
|
||||||
|
|
||||||
async def check_meter_frozen(self) -> None:
|
async def check_meter_frozen(self) -> None:
|
||||||
"""SAFETY-18. Alarm on a meter that answers forever without changing.
|
"""SAFETY-18. Alarm on a meter that answers forever without changing.
|
||||||
|
|
||||||
@@ -1265,6 +1361,13 @@ class Controller:
|
|||||||
elif _pg.saturated:
|
elif _pg.saturated:
|
||||||
out.append({"ok": False, "warn": False,
|
out.append({"ok": False, "warn": False,
|
||||||
"text": "PEAK GUARD SATURATED - " + _pg.reason})
|
"text": "PEAK GUARD SATURATED - " + _pg.reason})
|
||||||
|
elif _pg.floor_limited:
|
||||||
|
# SAFETY-24. NOT ok, like saturation: in both states the money
|
||||||
|
# is going to be spent and a human is the only actuator left. A
|
||||||
|
# separate row from saturation because the two ask for opposite
|
||||||
|
# things - see check_peak_floor_limited().
|
||||||
|
out.append({"ok": False, "warn": False,
|
||||||
|
"text": _pg.explain()})
|
||||||
elif _pg.blind:
|
elif _pg.blind:
|
||||||
out.append({"ok": False, "warn": True, "text": _pg.explain()})
|
out.append({"ok": False, "warn": True, "text": _pg.explain()})
|
||||||
else:
|
else:
|
||||||
|
|||||||
@@ -246,19 +246,100 @@ validate.py are untouched by this ticket, exactly as TARIFF-01 left them, and
|
|||||||
mismatch trap 14's own warning box describes.
|
mismatch trap 14's own warning box describes.
|
||||||
|
|
||||||
------------------------------------------------------------------------------
|
------------------------------------------------------------------------------
|
||||||
⚠️ WHAT THIS GUARD DOES NOT HAVE: AN ENERGY BACKSTOP. SEE SAFETY-24.
|
SAFETY-24: THE ENERGY BACKSTOP THIS GUARD SHIPPED WITHOUT
|
||||||
|
|
||||||
The graded branch can FORCE DISCHARGE, and nothing in this file or in the loop
|
SAFETY-07 left this file saying, in its own words, that the graded branch can
|
||||||
below it consults the state of charge - `soc_floor` belongs to the maintenance
|
FORCE DISCHARGE and that nothing below it consults the state of charge - "the
|
||||||
cycle, and freeze.py already records that for the grid-following loop "the BMS
|
BMS is the sole energy backstop" (freeze.py). On the 2026-08-20 replay the guard
|
||||||
is the sole energy backstop". On the 2026-08-20 replay the guard asks for 878 Wh
|
asks for 878 Wh in a day, and it keeps asking for as long as the meter says the
|
||||||
in a day. Against a pack sitting near 9 % that is not nothing, and the guard will
|
quarter is over the ceiling. That is the behaviour working as designed, and it
|
||||||
keep asking as long as the meter says the quarter is over the ceiling.
|
is unbounded from below by anything in the EMS.
|
||||||
|
|
||||||
That is deliberate for THIS card and it is filed as SAFETY-24. It is also the
|
⚠️ STATE THE RISK FAIRLY, because overstating it is how a real one gets ignored.
|
||||||
reason this must not go to a client install before SAFETY-24 lands: on the
|
Relying on the BMS is not absurd: it is a genuine floor and it works. But it is
|
||||||
reference site the BMS is a known quantity and an operator is present, and on a
|
THE PACK's protection, not the OPERATOR's. A month of aggressive quarters can
|
||||||
client site neither is true.
|
leave the battery repeatedly parked at that floor with no EMS-side record of
|
||||||
|
why, and the first symptom - a pack that is never available when it is wanted -
|
||||||
|
is indistinguishable from the SoC drift MAINT-01 exists to correct.
|
||||||
|
|
||||||
|
So `decide()` now takes `soc` and `soc_floor`, and `discharge_permitted()` is
|
||||||
|
the one place the question is answered. Four things about the shape of it:
|
||||||
|
|
||||||
|
1. IT IS NOT A TRIP, AND IT MUST NOT BECOME ONE. SAFETY-07's claim is a LIMIT
|
||||||
|
and every stop in 11.2's table still outranks it. This floor is about
|
||||||
|
ENERGY - how far down the guard may spend the pack for money - not about
|
||||||
|
last-resort safety. The action when it binds is therefore to stop ASKING
|
||||||
|
for more discharge, not to command anything.
|
||||||
|
|
||||||
|
2. THE ACTION IS `floor_w = 0.0`, WHICH IS THE BLIND BRANCH'S ACTION FOR THE
|
||||||
|
BLIND BRANCH'S REASON. Zero is one-directional: it forbids CHARGING, which
|
||||||
|
can only ever lower delivered offtake, and it forbids nothing else. It
|
||||||
|
cannot pull the loop off a discharge it is already doing, because a `lo`
|
||||||
|
limit structurally cannot cap discharge - the property this module's whole
|
||||||
|
shape rests on, and one a NEGATIVE floor would destroy. Nothing here can
|
||||||
|
produce a negative floor: the only two values `floor_w` ever takes are 0.0
|
||||||
|
and `min(wanted, achievable)` with `wanted > 0` already established.
|
||||||
|
|
||||||
|
⚠️ AND IT DOES NOT BOUND THE LOOP. Self-consumption may still drain the
|
||||||
|
pack past this floor, exactly as SAFETY-18 recorded. That is not fixed
|
||||||
|
here and must not be claimed: this card bounds THE PEAK GUARD's OWN forced
|
||||||
|
discharge, which is the thing SAFETY-07 introduced. A loop-side SoC guard
|
||||||
|
is a different lever with a different right value.
|
||||||
|
|
||||||
|
3. IT IS GRADED ONLY WHERE IT IS NOT DEGENERATE. The SoC question is asked
|
||||||
|
AFTER `wanted > 0` is established - i.e. only where a forced discharge is
|
||||||
|
actually being asked for. Asked earlier it would grade a quantity that
|
||||||
|
governs nothing, and would report "floor-limited" on a quiet afternoon
|
||||||
|
where the guard was never going to discharge anyway.
|
||||||
|
|
||||||
|
4. AN UNREADABLE SoC IS NOT A FULL BATTERY. `soc=None` is floor-limited, not
|
||||||
|
permitted. This is `PeakReading`'s lesson in the one place it bites
|
||||||
|
hardest: a full battery is exactly the value that would disarm this floor,
|
||||||
|
so a failed read defaulting to one would silently restore the unbounded
|
||||||
|
discharge this card exists to remove. Both new arguments are REQUIRED
|
||||||
|
keyword-only and neither has a default, which is TEST-14 read as a rule
|
||||||
|
rather than as a story: a required field that gains a default is how three
|
||||||
|
separate files in this repo shipped a quiet fallback.
|
||||||
|
|
||||||
|
AND FAILING TO SHAVE MUST NOT BE SILENT. The whole point of the guard is the
|
||||||
|
euro figure, so a floor-limited cycle carries `floor_limited=True` and main.py
|
||||||
|
raises ONE notification on the edge, saying the quarter will be exceeded - the
|
||||||
|
same shape, and the same argument, as `saturated`. The two are mutually
|
||||||
|
exclusive by construction: a floor-limited decision asks for nothing, so it
|
||||||
|
cannot have run out of inverter.
|
||||||
|
|
||||||
|
------------------------------------------------------------------------------
|
||||||
|
CFG-03: TWO NEW OPTIONS, MIRRORED ONCE, AND WHY BOTH ARE NEEDED
|
||||||
|
|
||||||
|
SAFETY-07 added none and said so. This card cannot: an EMS-side floor is a
|
||||||
|
number only the site knows, and refusing one set below the pack's own cut-out
|
||||||
|
means knowing that cut-out too.
|
||||||
|
|
||||||
|
* `peak_soc_floor` - the EMS floor. ⚠️ NOT `maintenance_soc_floor`. That is
|
||||||
|
the maintenance cycle's DRAIN TARGET: the depth a monthly recalibration
|
||||||
|
deliberately goes to, once, under supervision. This is the depth a
|
||||||
|
money-saving discharge may never reach, on any day of the month. Sharing
|
||||||
|
one key would couple two features whose right values differ and would widen
|
||||||
|
CFG-03 rather than narrow it.
|
||||||
|
* `bms_soc_floor` - the pack's own cut-out (register 0x0560 on the reference
|
||||||
|
unit, 10 %). It is here so validate.py rule 8 can REFUSE a `peak_soc_floor`
|
||||||
|
at or below it. That configuration is CFG-01 rule (a): the operator states
|
||||||
|
a floor, the BMS enforces a different one, and the status page reports an
|
||||||
|
energy backstop that can never bind.
|
||||||
|
|
||||||
|
Both defaults are mirrored ONCE, in `PEAK_OPTION_DEFAULTS` below, which is
|
||||||
|
TARIFF-02's `PRICE_OPTION_DEFAULTS` pattern - imported by validate.py and by
|
||||||
|
main.py, pinned to config.yaml by test_peakguard.py rather than transcribed.
|
||||||
|
This module still reads no option itself: `decide()` takes both as ARGUMENTS,
|
||||||
|
makes no `.get()` call, and the mirror is a default table, not a read.
|
||||||
|
|
||||||
|
⚠️ A DECISION RECORDED, NOT A RENAME DONE. Now that a second SoC floor exists,
|
||||||
|
`maintenance_soc_floor` is the ambiguous name of the two - it reads like "the
|
||||||
|
SoC floor" and is not. Renaming it is an option migration on a live install for
|
||||||
|
a clarity gain, so the decision recorded here is: KEEP IT, and carry the
|
||||||
|
distinction in DOCS.md and in this comment. Revisit if a THIRD floor appears -
|
||||||
|
a loop-side guard would be the third - at which point the migration buys enough
|
||||||
|
to be worth its cost.
|
||||||
|
|
||||||
------------------------------------------------------------------------------
|
------------------------------------------------------------------------------
|
||||||
AND IT READS NO PER-PHASE QUANTITY, ON PURPOSE
|
AND IT READS NO PER-PHASE QUANTITY, ON PURPOSE
|
||||||
@@ -287,8 +368,44 @@ BLIND_FROZEN = "SAFETY-18: the meter is answering without changing"
|
|||||||
CEILING_CAP = "peak_cap_w"
|
CEILING_CAP = "peak_cap_w"
|
||||||
CEILING_MONTH_PEAK = "the month's banked peak"
|
CEILING_MONTH_PEAK = "the month's banked peak"
|
||||||
|
|
||||||
|
# SAFETY-24. Why the forced discharge may not be sized. Reasons, not booleans,
|
||||||
|
# for BLIND_*'s reason: the status page, the action log and the operator
|
||||||
|
# notification all have to say WHICH, and "floor-limited" alone is unactionable.
|
||||||
|
FLOOR_SOC_UNREADABLE = ("the battery state of charge was not measured this "
|
||||||
|
"cycle, and an unreadable SoC is not a full battery")
|
||||||
|
FLOOR_AT_SOC_FLOOR = "state of charge is at or below the peak guard's SoC floor"
|
||||||
|
|
||||||
SOURCE = "peak"
|
SOURCE = "peak"
|
||||||
|
|
||||||
|
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR THIS CARD'S OPTIONS, and
|
||||||
|
# it is TARIFF-02's `PRICE_OPTION_DEFAULTS` pattern for TARIFF-02's reason: the
|
||||||
|
# add-on already carries option defaults in three places (config.yaml's
|
||||||
|
# `options:`, config.yaml's `schema:`, and main.py's literal `.get()`
|
||||||
|
# fallbacks), and a fourth is the open ticket. validate.py and main.py both
|
||||||
|
# import THIS dict rather than typing a literal, and test_peakguard.py pins it
|
||||||
|
# to config.yaml by READING the file - so a drift goes red instead of shipping.
|
||||||
|
#
|
||||||
|
# ⚠️ NOT A READ. `decide()` takes both values as arguments and this module makes
|
||||||
|
# no `.get()` call at all; the dict is a default table for its two callers.
|
||||||
|
PEAK_OPTION_DEFAULTS = {
|
||||||
|
# The EMS-side floor on SAFETY-07's forced discharge, in percent.
|
||||||
|
#
|
||||||
|
# 20 is DERIVED from the two numbers this repository already has, not
|
||||||
|
# chosen. The reference pack is 300 Ah at 51.2 V with DoD 90 - 13.8 kWh
|
||||||
|
# usable, the figure validate.py's rule 6 note already quotes - and the
|
||||||
|
# 2026-08-20 replay models 878 Wh of guard discharge in a day, which is
|
||||||
|
# 6.4 % of that. A floor 10 points above the pack's own 10 % cut-out
|
||||||
|
# therefore leaves the guard roughly 1.6 of its worst observed days of room
|
||||||
|
# before it stops, which is the smallest margin that lets the guard do its
|
||||||
|
# job on a bad day and still never reach the BMS.
|
||||||
|
"peak_soc_floor": 20,
|
||||||
|
# The pack's OWN cut-out, in percent: what the BMS enforces regardless of
|
||||||
|
# anything here. On the reference unit this is register 0x0560, read as 10,
|
||||||
|
# and it is consistent with DoD 90 on a full pack. It exists so validate.py
|
||||||
|
# rule 8 can refuse a `peak_soc_floor` at or below it - see that rule.
|
||||||
|
"bms_soc_floor": 10,
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
@dataclass(frozen=True)
|
@dataclass(frozen=True)
|
||||||
class PeakDecision:
|
class PeakDecision:
|
||||||
@@ -309,9 +426,19 @@ class PeakDecision:
|
|||||||
excess_w: float = 0.0
|
excess_w: float = 0.0
|
||||||
wanted_w: float | None = None # the floor before `achievable_w` clamped it
|
wanted_w: float | None = None # the floor before `achievable_w` clamped it
|
||||||
saturated: bool = False
|
saturated: bool = False
|
||||||
|
# SAFETY-24. True when a forced discharge WAS wanted and the EMS-side SoC
|
||||||
|
# floor refused to size it. Mutually exclusive with `saturated` by
|
||||||
|
# construction: this branch asks for nothing, so it cannot have run out of
|
||||||
|
# inverter. `soc_floor_reason` says WHICH of the two ways it bound.
|
||||||
|
floor_limited: bool = False
|
||||||
|
soc: float | None = None
|
||||||
|
soc_floor: float | None = None
|
||||||
|
soc_floor_reason: str | None = None
|
||||||
reason: str = ""
|
reason: str = ""
|
||||||
|
|
||||||
def explain(self) -> str:
|
def explain(self) -> str:
|
||||||
|
if self.floor_limited:
|
||||||
|
return self.reason
|
||||||
if not self.engaged:
|
if not self.engaged:
|
||||||
if self.projected_w is None:
|
if self.projected_w is None:
|
||||||
return f"peak guard idle - {self.reason}"
|
return f"peak guard idle - {self.reason}"
|
||||||
@@ -383,7 +510,44 @@ def blindness(projection, max_hold_s, frozen: bool) -> str | None:
|
|||||||
return None
|
return None
|
||||||
|
|
||||||
|
|
||||||
def decide(projection, *, batt_w, cap_w, reading, achievable_w,
|
def discharge_permitted(soc, soc_floor) -> str | None:
|
||||||
|
"""SAFETY-24. May the guard size a forced discharge, or why may it not?
|
||||||
|
|
||||||
|
Returns None when it may, and otherwise the REASON it may not - which the
|
||||||
|
decision, the status page, the action log and the operator notification all
|
||||||
|
carry, because "floor-limited" on its own tells nobody what to do.
|
||||||
|
|
||||||
|
THE ONE PLACE THIS QUESTION IS ANSWERED, and it is public for the reason
|
||||||
|
`freeze.looks_frozen()`, `watchdog.loop_is_following()` and
|
||||||
|
`shaping_suspended()` are: a safety predicate transcribed into its own check
|
||||||
|
is one copy plus a future disagreement about what the check means, and the
|
||||||
|
copy that drifts is always the grading one.
|
||||||
|
|
||||||
|
⚠️ `soc is None` IS NOT PERMISSION. A failed read is not an observation, and
|
||||||
|
a FULL BATTERY is exactly the value that would disarm this floor - so a
|
||||||
|
`float(soc or 100)` here would restore the unbounded discharge this card
|
||||||
|
removes, silently, on the one install whose SoC sensor is misnamed. There is
|
||||||
|
deliberately no default argument on either parameter.
|
||||||
|
|
||||||
|
⚠️ AND `soc_floor is None` IS NOT PERMISSION EITHER, for the same reason one
|
||||||
|
step further out: a caller that has no floor configured has not thereby been
|
||||||
|
granted an unbounded one.
|
||||||
|
|
||||||
|
Boundary: `<=`, not `<`. A pack sitting exactly ON the floor has already
|
||||||
|
spent everything this guard was allowed to spend; permitting one more cycle
|
||||||
|
there would make the floor mean "one cycle below the floor".
|
||||||
|
"""
|
||||||
|
if soc is None:
|
||||||
|
return FLOOR_SOC_UNREADABLE
|
||||||
|
if soc_floor is None:
|
||||||
|
return ("no peak guard SoC floor is configured, so there is nothing to "
|
||||||
|
"bound a forced discharge with")
|
||||||
|
if float(soc) <= float(soc_floor):
|
||||||
|
return FLOOR_AT_SOC_FLOOR
|
||||||
|
return None
|
||||||
|
|
||||||
|
|
||||||
|
def decide(projection, *, batt_w, cap_w, reading, achievable_w, soc, soc_floor,
|
||||||
max_hold_s=None, frozen: bool = False) -> PeakDecision:
|
max_hold_s=None, frozen: bool = False) -> PeakDecision:
|
||||||
"""The whole guard. Pure: no clock, no I/O, no state carried between calls.
|
"""The whole guard. Pure: no clock, no I/O, no state carried between calls.
|
||||||
|
|
||||||
@@ -395,6 +559,13 @@ def decide(projection, *, batt_w, cap_w, reading, achievable_w,
|
|||||||
claim can NEVER produce `lo > hi` in the resolver - a
|
claim can NEVER produce `lo > hi` in the resolver - a
|
||||||
contradiction there resolves to 0 W, which would park the
|
contradiction there resolves to 0 W, which would park the
|
||||||
battery in the exact minute it should be discharging hardest.
|
battery in the exact minute it should be discharging hardest.
|
||||||
|
`soc` SAFETY-24. MEASURED state of charge, percent. None when the
|
||||||
|
sensor for it did not answer - which is floor-limited, not
|
||||||
|
permission.
|
||||||
|
`soc_floor` SAFETY-24. The percent below which this guard may not spend
|
||||||
|
the pack for money. REQUIRED, and deliberately without a
|
||||||
|
default: a default here would be CFG-03's fourth defaults
|
||||||
|
site and TEST-14's quiet fallback in one line.
|
||||||
"""
|
"""
|
||||||
ceiling, from_where = quarter_ceiling_w(cap_w, reading)
|
ceiling, from_where = quarter_ceiling_w(cap_w, reading)
|
||||||
ceil_top = abs(float(achievable_w))
|
ceil_top = abs(float(achievable_w))
|
||||||
@@ -454,12 +625,41 @@ def decide(projection, *, batt_w, cap_w, reading, achievable_w,
|
|||||||
wanted_w=wanted,
|
wanted_w=wanted,
|
||||||
reason="the load is under the level this quarter can afford")
|
reason="the load is under the level this quarter can afford")
|
||||||
|
|
||||||
|
# SAFETY-24 - AND ONLY HERE. `wanted > 0` is now established, so a forced
|
||||||
|
# discharge really is being asked for and the SoC is the quantity that
|
||||||
|
# decides whether it may be sized. Asked one line earlier it would grade a
|
||||||
|
# number that governs nothing on every quiet cycle of the day, and would
|
||||||
|
# report "floor-limited" over a guard that was never going to discharge.
|
||||||
|
denied = discharge_permitted(soc, soc_floor)
|
||||||
|
if denied is not None:
|
||||||
|
# 0.0, not `wanted`, and not a negative number. Zero forbids CHARGING -
|
||||||
|
# one-directional, cannot cost pack energy - and forbids nothing else;
|
||||||
|
# a `lo` limit structurally cannot cap the discharge the loop is already
|
||||||
|
# doing. See the module note: this bounds THE GUARD's forced discharge,
|
||||||
|
# not the grid-following loop, which still has no SoC guard.
|
||||||
|
return PeakDecision(
|
||||||
|
engaged=True, floor_w=0.0, ceiling_w=ceiling,
|
||||||
|
ceiling_from=from_where, projected_w=projected, excess_w=ex,
|
||||||
|
wanted_w=wanted, floor_limited=True, soc=soc, soc_floor=soc_floor,
|
||||||
|
soc_floor_reason=denied,
|
||||||
|
reason=(
|
||||||
|
f"PEAK GUARD FLOOR-LIMITED: the quarter projects "
|
||||||
|
f"{projected:.0f} W against a {ceiling:.0f} W ceiling "
|
||||||
|
f"({from_where}) and {wanted:+.0f} W of discharge would hold "
|
||||||
|
f"it, but {denied}"
|
||||||
|
+ ("" if soc is None else f" ({float(soc):.0f} %")
|
||||||
|
+ ("" if soc is None or soc_floor is None
|
||||||
|
else f" vs {float(soc_floor):.0f} %")
|
||||||
|
+ ("" if soc is None else ")")
|
||||||
|
+ " - commanding no forced discharge, so THIS QUARTER WILL GO "
|
||||||
|
"OVER THE CEILING. Charging stays blocked (floor 0 W)"))
|
||||||
|
|
||||||
floor = min(wanted, ceil_top)
|
floor = min(wanted, ceil_top)
|
||||||
saturated = floor < wanted
|
saturated = floor < wanted
|
||||||
return PeakDecision(
|
return PeakDecision(
|
||||||
engaged=True, floor_w=floor, ceiling_w=ceiling, ceiling_from=from_where,
|
engaged=True, floor_w=floor, ceiling_w=ceiling, ceiling_from=from_where,
|
||||||
blind=None, projected_w=projected, excess_w=ex, wanted_w=wanted,
|
blind=None, projected_w=projected, excess_w=ex, wanted_w=wanted,
|
||||||
saturated=saturated,
|
saturated=saturated, soc=soc, soc_floor=soc_floor,
|
||||||
reason=(
|
reason=(
|
||||||
f"PEAK GUARD: quarter projects {projected:.0f} W against a "
|
f"PEAK GUARD: quarter projects {projected:.0f} W against a "
|
||||||
f"{ceiling:.0f} W ceiling ({from_where}) with "
|
f"{ceiling:.0f} W ceiling ({from_where}) with "
|
||||||
@@ -513,5 +713,13 @@ def claim(decision: PeakDecision) -> Claim | None:
|
|||||||
"""
|
"""
|
||||||
if not decision.engaged or decision.floor_w is None:
|
if not decision.engaged or decision.floor_w is None:
|
||||||
return None
|
return None
|
||||||
|
# Three reasons, not two. A `lo = 0 W` claim reaches the arbiter from THREE
|
||||||
|
# different states now - blind, floor-limited, and a genuine floor that
|
||||||
|
# happens to be zero - and the arbiter's explain() is what an operator reads
|
||||||
|
# when the battery stops charging. Spelling them the same way would make the
|
||||||
|
# SAFETY-24 case indistinguishable from the SAFETY-18 one on the one line
|
||||||
|
# that gets read.
|
||||||
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
|
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
|
||||||
reason=("blind" if decision.blind else "quarter peak"))
|
reason=("blind" if decision.blind
|
||||||
|
else "SoC floor" if decision.floor_limited
|
||||||
|
else "quarter peak"))
|
||||||
|
|||||||
@@ -131,6 +131,25 @@ NOT READY banner already names the problem, (b) does not apply.
|
|||||||
installed base is on a fixed or static tariff. Refusing to start without a
|
installed base is on a fixed or static tariff. Refusing to start without a
|
||||||
price feed would lock those sites out of the add-on entirely.
|
price feed would lock those sites out of the add-on entirely.
|
||||||
|
|
||||||
|
8. `peak_soc_floor` at or below `bms_soc_floor`. [(a)]
|
||||||
|
SAFETY-24, and the same shape as 1, 4, 5 and 6. The peak guard can COMMAND
|
||||||
|
a discharge to hold a billed quarter down (SAFETY-07), and `peak_soc_floor`
|
||||||
|
is the EMS-side bound on how far down it may take the pack. The BMS has its
|
||||||
|
own cut-out and enforces it regardless. Set the EMS floor at or below that
|
||||||
|
cut-out and THE BMS WINS: the EMS bound can never be the thing that stops
|
||||||
|
the discharge, so the add-on carries an energy backstop that is incapable
|
||||||
|
of binding while its status page reports one - rule 5's "a disarmed guard
|
||||||
|
that advertises itself as armed", on the guard whose failure mode is a pack
|
||||||
|
that is quietly never available when it is wanted.
|
||||||
|
|
||||||
|
⚠️ `<=`, NOT `<`, and the equality case is the interesting one. At exactly
|
||||||
|
equal, the EMS floor and the pack's cut-out act at the same percent, so the
|
||||||
|
EMS floor buys ZERO margin - it can never prevent the pack reaching the BMS
|
||||||
|
limit, which is the entire thing this option exists to prevent. That is not
|
||||||
|
"close to the rail", it is the disarmed case with an extra step. Rule 6
|
||||||
|
permits equality because equality there leaves one reachable point that
|
||||||
|
works; here it leaves none.
|
||||||
|
|
||||||
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||||
|
|
||||||
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
||||||
@@ -151,12 +170,17 @@ WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
|||||||
- `maintenance_discharge_w` above `max_w`. Clamped, not contradicted, and the
|
- `maintenance_discharge_w` above `max_w`. Clamped, not contradicted, and the
|
||||||
clamp names itself in the arbiter's explain() - see rule 6. Warned about,
|
clamp names itself in the arbiter's explain() - see rule 6. Warned about,
|
||||||
not refused.
|
not refused.
|
||||||
|
- `peak_soc_floor` below `maintenance_soc_floor`, or above it. They are
|
||||||
|
DIFFERENT QUANTITIES (SAFETY-24: a drain target versus a spend limit) and
|
||||||
|
every ordering of the two is a legitimate site configuration. Refusing on
|
||||||
|
an ordering would be inventing a relationship the system does not have.
|
||||||
"""
|
"""
|
||||||
|
|
||||||
import logging
|
import logging
|
||||||
|
|
||||||
from .arbitrage import enabled as arbitrage_on
|
from .arbitrage import enabled as arbitrage_on
|
||||||
from .p1 import is_enabled, validate_meter_options
|
from .p1 import is_enabled, validate_meter_options
|
||||||
|
from .peakguard import PEAK_OPTION_DEFAULTS
|
||||||
from .price import PRICE_OPTION_DEFAULTS, PROVIDERS
|
from .price import PRICE_OPTION_DEFAULTS, PROVIDERS
|
||||||
from .static_tariff import ProfileInvalid, parse_static_profile
|
from .static_tariff import ProfileInvalid, parse_static_profile
|
||||||
|
|
||||||
@@ -370,6 +394,36 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
|||||||
# --- 7. two price sources on one site ------------------------------------
|
# --- 7. two price sources on one site ------------------------------------
|
||||||
problems.extend(_price_problems(opts))
|
problems.extend(_price_problems(opts))
|
||||||
|
|
||||||
|
# --- 8. an EMS energy floor the BMS does not already enforce -------------
|
||||||
|
# ⚠️ THE FALLBACKS ARE peakguard.PEAK_OPTION_DEFAULTS, NOT LITERALS, and
|
||||||
|
# that is CFG-03 read as a rule rather than as a complaint. Rule 6's own
|
||||||
|
# comment documents a LIVE divergence in this repo caused by typing 2000
|
||||||
|
# here and 2500 in main.py; this card refuses to add a second instance of
|
||||||
|
# it. The dict is the single in-code mirror, pinned to config.yaml by
|
||||||
|
# test_peakguard.py, and main.py reads the same one.
|
||||||
|
soc_floor = _number(opts, "peak_soc_floor",
|
||||||
|
PEAK_OPTION_DEFAULTS["peak_soc_floor"])
|
||||||
|
bms_floor = _number(opts, "bms_soc_floor",
|
||||||
|
PEAK_OPTION_DEFAULTS["bms_soc_floor"])
|
||||||
|
if soc_floor is None or bms_floor is None:
|
||||||
|
problems.append(
|
||||||
|
"peak_soc_floor and bms_soc_floor must both be numbers (got "
|
||||||
|
f"{opts.get('peak_soc_floor')!r} / {opts.get('bms_soc_floor')!r})")
|
||||||
|
elif soc_floor <= bms_floor:
|
||||||
|
problems.append(
|
||||||
|
f"peak_soc_floor is {soc_floor:.0f} % but the pack's own cut-out "
|
||||||
|
f"(bms_soc_floor) is {bms_floor:.0f} %, so SAFETY-07's forced "
|
||||||
|
"discharge has no EMS-side bound at all - THE BMS WINS, and it is "
|
||||||
|
"the pack's protection rather than yours. The guard would report a "
|
||||||
|
"SoC floor on its status page while being incapable of ever being "
|
||||||
|
"the thing that stops the discharge, and the symptom of that is a "
|
||||||
|
"battery repeatedly sitting at the BMS limit with no record of why "
|
||||||
|
f"- which looks exactly like the SoC drift the maintenance cycle "
|
||||||
|
f"exists to correct. Raise peak_soc_floor above {bms_floor:.0f} % "
|
||||||
|
f"(the shipped default is "
|
||||||
|
f"{PEAK_OPTION_DEFAULTS['peak_soc_floor']:.0f} %), or correct "
|
||||||
|
"bms_soc_floor if it does not match this pack.")
|
||||||
|
|
||||||
# --- warnings: real, but not worth refusing over -------------------------
|
# --- warnings: real, but not worth refusing over -------------------------
|
||||||
integ = opts.get("integrator_max_w")
|
integ = opts.get("integrator_max_w")
|
||||||
integ_w = None if not integ else _number(opts, "integrator_max_w", None)
|
integ_w = None if not integ else _number(opts, "integrator_max_w", None)
|
||||||
|
|||||||
@@ -163,6 +163,37 @@ options:
|
|||||||
peak_forecast_entity: ""
|
peak_forecast_entity: ""
|
||||||
peak_cap_w: 3500
|
peak_cap_w: 3500
|
||||||
|
|
||||||
|
# --- SAFETY-24: the energy backstop under SAFETY-07's forced discharge -----
|
||||||
|
# The peak guard can COMMAND a discharge to hold a billed quarter under
|
||||||
|
# peak_cap_w. Until this card it was bounded from below by nothing but the
|
||||||
|
# pack's own BMS cut-out - a real floor, but the PACK's protection rather than
|
||||||
|
# the OPERATOR's. On the 2026-08-20 replay the guard asks for 878 Wh in a day.
|
||||||
|
#
|
||||||
|
# peak_soc_floor is the percent below which that discharge is not sized. When
|
||||||
|
# it binds the guard reports FLOOR-LIMITED, keeps charging blocked (a 0 W
|
||||||
|
# floor), and the add-on raises ONE notification saying the quarter will be
|
||||||
|
# exceeded - failing to shave is never silent, because the euro figure is the
|
||||||
|
# whole point of the guard.
|
||||||
|
#
|
||||||
|
# ⚠️ THIS IS NOT maintenance_soc_floor AND MUST NOT BE MERGED WITH IT.
|
||||||
|
# maintenance_soc_floor is the DRAIN TARGET of the monthly recalibration: the
|
||||||
|
# depth the cycle deliberately goes to, once a month, on purpose. This is the
|
||||||
|
# depth a money-saving discharge may never reach on any day. The right values
|
||||||
|
# differ, and sharing one key would couple two features that want to move
|
||||||
|
# independently.
|
||||||
|
#
|
||||||
|
# ⚠️ 20 IS DERIVED, NOT PICKED. The reference pack is 13.8 kWh usable and the
|
||||||
|
# worst modelled guard day is 878 Wh, i.e. 6.4 % - so 10 points above the
|
||||||
|
# pack's own cut-out leaves the guard ~1.6 of its worst observed days of room
|
||||||
|
# and still never reaches the BMS.
|
||||||
|
peak_soc_floor: 20
|
||||||
|
# The pack's OWN cut-out percent - what the BMS enforces whatever is set
|
||||||
|
# above. Register 0x0560 reads 10 on the reference GW5000S-BP, consistent with
|
||||||
|
# DoD 90. It is here so validate.py can REFUSE a peak_soc_floor at or below
|
||||||
|
# it: such a floor can never bind, the BMS wins, and the status page would
|
||||||
|
# report an energy backstop that does not exist.
|
||||||
|
bms_soc_floor: 10
|
||||||
|
|
||||||
# ⚠️ THE OLD PRICE PATH, AND IT IS NOT DEAD YET. These two entities are the
|
# ⚠️ THE OLD PRICE PATH, AND IT IS NOT DEAD YET. These two entities are the
|
||||||
# add-on delegating the whole price question to Home Assistant: main.py reads
|
# add-on delegating the whole price question to Home Assistant: main.py reads
|
||||||
# both and derives ONE BOOLEAN, `cheap = now <= avg`, which is consumed by
|
# both and derives ONE BOOLEAN, `cheap = now <= avg`, which is consumed by
|
||||||
@@ -343,6 +374,12 @@ schema:
|
|||||||
|
|
||||||
peak_forecast_entity: str?
|
peak_forecast_entity: str?
|
||||||
peak_cap_w: int(500,15000)
|
peak_cap_w: int(500,15000)
|
||||||
|
# SAFETY-24. No "off" value: a guard that can command a discharge does not get
|
||||||
|
# a supported way to have no energy bound at all. The ranges OVERLAP on
|
||||||
|
# purpose - the schema cannot express "above bms_soc_floor", so validate.py
|
||||||
|
# rule 8 is what refuses the pair, with a message naming both numbers.
|
||||||
|
peak_soc_floor: int(5,60)
|
||||||
|
bms_soc_floor: int(0,50)
|
||||||
price_now_entity: str?
|
price_now_entity: str?
|
||||||
price_avg_entity: str?
|
price_avg_entity: str?
|
||||||
|
|
||||||
|
|||||||
File diff suppressed because it is too large
Load Diff
@@ -0,0 +1,551 @@
|
|||||||
|
#!/usr/bin/env python3
|
||||||
|
"""DATA-02: fetch 12 months of EPEX BE day-ahead prices, in §9.3's shape.
|
||||||
|
|
||||||
|
python3 scenarios/fetch_epex_be.py --start 2025-09-01 --end 2026-09-01 \
|
||||||
|
--out scenarios/epex-be-dayahead-2025-09-01_2026-09-01.json
|
||||||
|
|
||||||
|
Run from `goodwe_controller/`. Rewrites the output file from scratch; the
|
||||||
|
committed dataset is exactly what this produces, and `--verify` re-derives every
|
||||||
|
claim the file makes about itself without going to the network.
|
||||||
|
|
||||||
|
|
||||||
|
WHAT THIS IS NOT
|
||||||
|
================
|
||||||
|
NOT wired into the add-on, and it must never be. `price.py`'s `GenericDayAhead`
|
||||||
|
is the live path and it has its own egress check; this is a one-shot archival
|
||||||
|
fetch that produces a file for REPLAY, run by hand by a developer. Nothing under
|
||||||
|
`app/` imports it.
|
||||||
|
|
||||||
|
|
||||||
|
THE SOURCE, AND WHY THIS ONE
|
||||||
|
============================
|
||||||
|
`https://api.energy-charts.info/price?bzn=BE` - Fraunhofer ISE's Energy-Charts
|
||||||
|
API. No key, no registration.
|
||||||
|
|
||||||
|
⚠️ THE LICENCE WAS CHECKED BEFORE ANY DATA WAS COMMITTED, because for this
|
||||||
|
source it is NOT uniform across bidding zones. The API's own OpenAPI document
|
||||||
|
(`https://api.energy-charts.info/openapi.json`, /price) splits the zones in two:
|
||||||
|
|
||||||
|
"The data for the following bidding zones is licensed as CC BY 4.0 from
|
||||||
|
Bundesnetzagentur | SMARD.de and is published without changes:
|
||||||
|
AT, BE (Belgium), CH, CZ, DE-LU, ..."
|
||||||
|
|
||||||
|
"The data for the other bidding zones is for private and internal use only.
|
||||||
|
The utilization of any data, whether in its raw or derived form, for
|
||||||
|
external or commercial purposes is expressly prohibited. Should you require
|
||||||
|
licensing for market-related data, please direct your inquiries to the
|
||||||
|
original data providers, including but not limited to EPEX SPOT SE."
|
||||||
|
|
||||||
|
BE is in the FIRST list, so redistribution is permitted with attribution and the
|
||||||
|
dataset is committed rather than left as a fetch script and a checksum. Every
|
||||||
|
response also carries the licence per-response in `license_info`, and this
|
||||||
|
script REFUSES to write a file if that field ever stops saying CC BY 4.0 - a
|
||||||
|
licence checked once by a human and assumed forever is a licence that changes
|
||||||
|
silently. Had BE been in the second list, the correct output of this card would
|
||||||
|
have been this script and a checksum and no data.
|
||||||
|
|
||||||
|
Attribution, carried in the dataset's own `provenance` block and reproduced
|
||||||
|
here: data CC BY 4.0, Bundesnetzagentur | SMARD.de, retrieved via Energy-Charts
|
||||||
|
(Fraunhofer ISE), https://energy-charts.info, published without changes.
|
||||||
|
|
||||||
|
Cross-checked against the upstream on 2026-08-31: SMARD's own chart_data series
|
||||||
|
`4996/DE` over 2026-04-10 matched this API's BE series on all 96 quarter-hours
|
||||||
|
with a maximum absolute difference of 0.00 EUR/MWh. "Published without changes"
|
||||||
|
is a claim worth checking once; `--verify` does not repeat it, because it is a
|
||||||
|
claim about the SOURCE and not about the file.
|
||||||
|
|
||||||
|
|
||||||
|
RAW WHOLESALE, AND THE ASSUMPTION THAT IS NOT BAKED IN
|
||||||
|
======================================================
|
||||||
|
⚠️ WHAT COMES BACK IS RAW WHOLESALE, EUR/MWh, DAY-AHEAD AUCTION CLEARING PRICE.
|
||||||
|
It is NOT all-in: no supplier markup, no distribution or transmission tariff, no
|
||||||
|
levies, no VAT. §9.3's canonical point is all-in, and TARIFF-02's whole trap is
|
||||||
|
a figure that already contains a component being handed to something that adds
|
||||||
|
it again.
|
||||||
|
|
||||||
|
So this file does NOT add one. `eur_per_kwh` in the output is the wholesale
|
||||||
|
figure converted from EUR/MWh, `provenance.all_in` is `false` beside it, and the
|
||||||
|
markup/tax assumption a consumer needs lives in `provenance.all_in_assumption`
|
||||||
|
as NUMBERS TO APPLY rather than numbers already applied. test_arbitrage.py
|
||||||
|
section 7 applies them where a reader can watch it happen.
|
||||||
|
|
||||||
|
The assumption's SHAPE is the part that is not arbitrary, and it decides which
|
||||||
|
conclusions depend on the guessed numbers at all:
|
||||||
|
|
||||||
|
all_in(h) = (wholesale(h) + markup + network_and_levies) * (1 + vat)
|
||||||
|
|
||||||
|
* The two ADDITIVE terms cancel out of a spread: max - min is unchanged by
|
||||||
|
them. So how often a day clears `cycle_cost_threshold_eur` does NOT depend
|
||||||
|
on the markup guess - only on the VAT multiplier.
|
||||||
|
* They do NOT cancel out of §17's negative-price guard, which compares ONE
|
||||||
|
hour's all-in price against zero. A wholesale hour at -0.02 EUR/kWh is
|
||||||
|
comfortably positive all-in once ~0.12 of fixed charges is added.
|
||||||
|
|
||||||
|
Both are asserted arithmetically in section 7 rather than believed, and the
|
||||||
|
trade count is reported on the raw spread as well, so a reader can see exactly
|
||||||
|
how much of the answer rests on the guess.
|
||||||
|
|
||||||
|
The numbers themselves (2026 Belgian residential dynamic contract, order of
|
||||||
|
magnitude) are a STATED GUESS, labelled as one everywhere they appear. They are
|
||||||
|
not a measurement and this card had nothing to measure them with.
|
||||||
|
|
||||||
|
|
||||||
|
HOURS, QUARTER-HOURS, AND THE SEAM IN THE MIDDLE OF THE YEAR
|
||||||
|
============================================================
|
||||||
|
⚠️ THE SOURCE CHANGES RESOLUTION PART-WAY THROUGH ANY RECENT 12 MONTHS. EPEX
|
||||||
|
day-ahead moved to a 15-minute market time unit in October 2025 and the feed
|
||||||
|
follows: 2025-09-10 comes back as 24 hourly points, 2025-12-10 as 96
|
||||||
|
quarter-hourly ones. An importer that assumed either one silently loses three
|
||||||
|
quarters of the year, or reads a quarter as an hour.
|
||||||
|
|
||||||
|
The canonical format is hourly, so quarter-hours are aggregated: an hour's price
|
||||||
|
is the unweighted mean of its four quarters. That is a STATED APPROXIMATION of
|
||||||
|
the hourly product, not the hourly product, and it errs in the direction that
|
||||||
|
matters here - averaging discards intra-hour variation, so the observed spread
|
||||||
|
is a LOWER bound on what a 15-minute strategy would see.
|
||||||
|
`provenance.resolution` records how many hours came from each source shape.
|
||||||
|
|
||||||
|
⚠️ AND A PARTIAL HOUR IS DROPPED, NOT AVERAGED OVER WHAT ARRIVED. An hour with
|
||||||
|
three of four quarters is an hour nobody published a complete price for; the
|
||||||
|
mean of three would be an invented number carrying no flag. Dropped hours are
|
||||||
|
listed in `provenance.gaps` with their timestamps, because a missing hour in a
|
||||||
|
feed is not a zero price, and a zero price is exactly the value that would make
|
||||||
|
everything look free.
|
||||||
|
|
||||||
|
|
||||||
|
SIZE: WHY THIS IS PLAIN JSON AND NOT A `.gz`, MEASURED
|
||||||
|
======================================================
|
||||||
|
The directory's existing captures are gzipped, so the default would have been to
|
||||||
|
gzip this too. Measured on the committed file instead of assumed:
|
||||||
|
|
||||||
|
working tree, plain JSON 893 171 bytes
|
||||||
|
what GIT actually stores for it (zlib, loose object) 74 590 bytes
|
||||||
|
what git would store for a committed `.json.gz` 56 504 bytes
|
||||||
|
|
||||||
|
⚠️ GIT ALREADY COMPRESSES BLOBS, so gzipping buys 18 KB - 24 % of an object
|
||||||
|
that is already 75 KB, in a repository whose three existing P1 captures cost
|
||||||
|
27 KB, 136 KB and 140 KB. Eighteen kilobytes is not worth making the provenance
|
||||||
|
block unreadable in a pull request, and the licence claim in that block is
|
||||||
|
precisely the thing a reviewer of this card has to read and check. Plain JSON
|
||||||
|
also greps, diffs line-by-line when a future refetch changes something, and is
|
||||||
|
what `--verify` opens. `load()` still handles `.gz` for a future dataset large
|
||||||
|
enough to want it; this one is not.
|
||||||
|
|
||||||
|
The P1 captures are gzipped for the opposite reason and it is not an
|
||||||
|
inconsistency: they are hundreds of thousands of telegram lines that no human
|
||||||
|
reads, and there is no metadata in them to review.
|
||||||
|
|
||||||
|
|
||||||
|
TIME
|
||||||
|
====
|
||||||
|
Every instant is carried as UTC and rendered with `app.price.brussels()`, the
|
||||||
|
module that already owns the EU DST rule without a tz database. There is no
|
||||||
|
second answer to that question here and there must not be: the point of
|
||||||
|
`brussels()` is that the 02:00-03:00 hour which happens twice in October is two
|
||||||
|
instants, and a 24-slot local-hour importer collapses them.
|
||||||
|
|
||||||
|
So a year is 8760 hours only if it contains no transition, or contains both and
|
||||||
|
they cancel - 25 in October, 23 in March. `--verify` therefore asserts the
|
||||||
|
PER-DAY counts, not the total, because the total is exactly the number a broken
|
||||||
|
importer also produces.
|
||||||
|
"""
|
||||||
|
|
||||||
|
import argparse
|
||||||
|
import gzip
|
||||||
|
import hashlib
|
||||||
|
import json
|
||||||
|
import os
|
||||||
|
import sys
|
||||||
|
import time
|
||||||
|
import urllib.error
|
||||||
|
import urllib.request
|
||||||
|
from collections import Counter, defaultdict
|
||||||
|
from datetime import datetime, timedelta, timezone
|
||||||
|
|
||||||
|
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||||
|
|
||||||
|
from app.price import brussels # noqa: E402
|
||||||
|
|
||||||
|
API = "https://api.energy-charts.info/price"
|
||||||
|
BZN = "BE"
|
||||||
|
LICENCE_MUST_CONTAIN = "CC BY 4.0"
|
||||||
|
UTC = timezone.utc
|
||||||
|
|
||||||
|
ATTRIBUTION = ("Data licensed CC BY 4.0 by Bundesnetzagentur | SMARD.de, "
|
||||||
|
"retrieved via the Energy-Charts API (Fraunhofer ISE), "
|
||||||
|
"https://energy-charts.info. Published without changes.")
|
||||||
|
|
||||||
|
# ⚠️ A GUESS, LABELLED AS ONE, AND APPLIED BY THE CONSUMER - NOT HERE.
|
||||||
|
# Order-of-magnitude 2026 Belgian residential dynamic contract. Nothing in this
|
||||||
|
# repository measured any part of it.
|
||||||
|
ALL_IN_ASSUMPTION = {
|
||||||
|
"form": "all_in = (wholesale + markup + network_and_levies) * (1 + vat)",
|
||||||
|
"markup_eur_per_kwh": 0.020,
|
||||||
|
"network_and_levies_eur_per_kwh": 0.100,
|
||||||
|
"vat_fraction": 0.06,
|
||||||
|
"status": "ASSUMPTION, NOT MEASURED. Stated so a consumer applies it "
|
||||||
|
"deliberately; the committed eur_per_kwh has none of it applied.",
|
||||||
|
"note": "The two additive terms cancel out of any spread, so an arbitrage "
|
||||||
|
"trade count depends on vat_fraction only. They do NOT cancel out "
|
||||||
|
"of the negative-price guard (17), which compares one hour's "
|
||||||
|
"all-in price against zero.",
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
|
PACE_S = 3.0 # between chunks, unconditionally
|
||||||
|
RETRIES = 6
|
||||||
|
|
||||||
|
|
||||||
|
def _get(url: str) -> dict:
|
||||||
|
"""One GET, backing off on 429 and 5xx.
|
||||||
|
|
||||||
|
⚠️ THIS IS A FREE PUBLIC SERVICE AND IT RATE-LIMITS. The first run of this
|
||||||
|
script was refused with 429 on its fifth chunk. Backing off is the polite
|
||||||
|
behaviour; it is also the correct one, because the alternative - catching
|
||||||
|
the error and carrying on - would produce a file that is silently missing a
|
||||||
|
month and says nothing about it. A refused request is not an empty month.
|
||||||
|
"""
|
||||||
|
req = urllib.request.Request(
|
||||||
|
url,
|
||||||
|
headers={"User-Agent": "goodwe-addon/DATA-02 (one-shot archival fetch)"})
|
||||||
|
wait = 5.0
|
||||||
|
for attempt in range(1, RETRIES + 1):
|
||||||
|
try:
|
||||||
|
with urllib.request.urlopen(req, timeout=90) as r:
|
||||||
|
return json.loads(r.read().decode("utf-8"))
|
||||||
|
except urllib.error.HTTPError as e:
|
||||||
|
if e.code not in (429, 500, 502, 503, 504) or attempt == RETRIES:
|
||||||
|
raise
|
||||||
|
print(f" HTTP {e.code}; backing off {wait:.0f}s "
|
||||||
|
f"(attempt {attempt}/{RETRIES})", file=sys.stderr)
|
||||||
|
time.sleep(wait)
|
||||||
|
wait *= 2
|
||||||
|
raise SystemExit(f"unreachable: {url}")
|
||||||
|
|
||||||
|
|
||||||
|
def local_midnight_utc(day: str) -> datetime:
|
||||||
|
"""The INSTANT at which Brussels midnight begins on `day` (YYYY-MM-DD).
|
||||||
|
|
||||||
|
⚠️ THE WINDOW IS LOCAL, NOT UTC, AND THE FIRST RUN OF THIS SCRIPT PROVED WHY.
|
||||||
|
Bounding it at 00:00 UTC starts the year at 02:00 CEST, which makes the first
|
||||||
|
Brussels day 22 hours long - and 22 is not one of the two lengths a
|
||||||
|
transition produces, so `report()` refused the file. A dataset whose first
|
||||||
|
day is short is a dataset whose "days per year" arithmetic is quietly wrong
|
||||||
|
everywhere downstream.
|
||||||
|
|
||||||
|
Derived from `brussels()` by trying the only two offsets Belgium has and
|
||||||
|
keeping the one that round-trips, rather than by restating the EU rule here.
|
||||||
|
"""
|
||||||
|
for hours in (1, 2):
|
||||||
|
guess = datetime.fromisoformat(f"{day}T00:00:00").replace(
|
||||||
|
tzinfo=timezone(timedelta(hours=hours))).astimezone(UTC)
|
||||||
|
if brussels(guess).isoformat() == f"{day}T00:00:00+0{hours}:00":
|
||||||
|
return guess
|
||||||
|
raise SystemExit(f"no Brussels midnight for {day!r} - brussels() disagrees "
|
||||||
|
f"with itself, which is a bug in price.py, not here.")
|
||||||
|
|
||||||
|
|
||||||
|
def _months(start: datetime, end: datetime):
|
||||||
|
"""[start, end) in month-sized chunks, so a bad chunk names its own window."""
|
||||||
|
a = start
|
||||||
|
while a < end:
|
||||||
|
b = min(end, (a.replace(day=1) + timedelta(days=32)).replace(day=1))
|
||||||
|
yield a, b
|
||||||
|
a = b
|
||||||
|
|
||||||
|
|
||||||
|
def fetch(start: datetime, end: datetime):
|
||||||
|
"""Raw {unix_second: EUR/MWh} over [start, end), deduplicated.
|
||||||
|
|
||||||
|
⚠️ A `null` price is DROPPED, never coerced. The API returns null for an
|
||||||
|
interval it holds no result for, and `or 0.0` is the version of this line
|
||||||
|
that ships a year of free electricity.
|
||||||
|
"""
|
||||||
|
seen, licences, nulls = {}, Counter(), 0
|
||||||
|
for a, b in _months(start, end):
|
||||||
|
# ⚠️ THE API'S `end` IS AN INCLUSIVE LOCAL DAY, AND THE WINDOW'S IS AN
|
||||||
|
# EXCLUSIVE INSTANT. Ask for the day containing the LAST hour of the
|
||||||
|
# chunk, derived from the instant rather than by subtracting a calendar
|
||||||
|
# day from the bound: `b - 1 day` drops the final local day whenever the
|
||||||
|
# window ends at local midnight, which is exactly how this window ends.
|
||||||
|
# The first run lost 2026-08-31 that way, silently - 8736 points instead
|
||||||
|
# of 8760 - and the points-plus-gaps accounting in report() is what
|
||||||
|
# noticed. A day nobody asked for is not a day with no prices.
|
||||||
|
first = brussels(a).date().isoformat()
|
||||||
|
last = brussels(b - timedelta(hours=1)).date().isoformat()
|
||||||
|
url = f"{API}?bzn={BZN}&start={first}&end={last}"
|
||||||
|
d = _get(url)
|
||||||
|
lic = str(d.get("license_info", ""))
|
||||||
|
licences[lic] += 1
|
||||||
|
if LICENCE_MUST_CONTAIN not in lic:
|
||||||
|
raise SystemExit(
|
||||||
|
f"REFUSING TO WRITE. {url} came back under licence {lic!r}, "
|
||||||
|
f"which does not say {LICENCE_MUST_CONTAIN!r}. The BE zone was "
|
||||||
|
f"redistributable when this card ran; if that has changed, the "
|
||||||
|
f"right output is this script and a checksum, not the data.")
|
||||||
|
unit = str(d.get("unit", ""))
|
||||||
|
if "MWh" not in unit:
|
||||||
|
raise SystemExit(
|
||||||
|
f"REFUSING TO WRITE. {url} reports unit {unit!r}, not EUR/MWh. "
|
||||||
|
f"A silent unit change is a factor of 1000 on every price.")
|
||||||
|
for t, p in zip(d["unix_seconds"], d["price"]):
|
||||||
|
if p is None:
|
||||||
|
nulls += 1
|
||||||
|
continue
|
||||||
|
if start.timestamp() <= t < end.timestamp():
|
||||||
|
seen[int(t)] = float(p)
|
||||||
|
print(f" {a.date()} .. {b.date()} {len(d['price']):5d} intervals",
|
||||||
|
file=sys.stderr)
|
||||||
|
time.sleep(PACE_S)
|
||||||
|
return seen, licences, nulls
|
||||||
|
|
||||||
|
|
||||||
|
def to_hourly(raw: dict):
|
||||||
|
"""Hourly means keyed by UTC hour. Returns (hours, gaps, shape_counts).
|
||||||
|
|
||||||
|
An hour is emitted only when every interval the source used for it arrived:
|
||||||
|
1 of 1 where the source was hourly, 4 of 4 where it was quarter-hourly.
|
||||||
|
Anything else is a gap and is named as one.
|
||||||
|
"""
|
||||||
|
buckets = defaultdict(dict)
|
||||||
|
for t, p in raw.items():
|
||||||
|
buckets[t - (t % 3600)][t % 3600] = p
|
||||||
|
|
||||||
|
hours, gaps, shapes = {}, [], Counter()
|
||||||
|
for h in sorted(buckets):
|
||||||
|
got = buckets[h]
|
||||||
|
if set(got) == {0}:
|
||||||
|
shapes["hourly"] += 1
|
||||||
|
hours[h] = got[0]
|
||||||
|
elif set(got) == {0, 900, 1800, 2700}:
|
||||||
|
shapes["quarter_hourly_mean"] += 1
|
||||||
|
hours[h] = sum(got.values()) / 4.0
|
||||||
|
else:
|
||||||
|
gaps.append({
|
||||||
|
"hour_utc": datetime.fromtimestamp(h, UTC).isoformat(),
|
||||||
|
"intervals_present": sorted(got),
|
||||||
|
"why": "incomplete hour - dropped rather than averaged over "
|
||||||
|
"what arrived; a partial read is not an observation",
|
||||||
|
})
|
||||||
|
return hours, gaps, shapes
|
||||||
|
|
||||||
|
|
||||||
|
def canonical(hours: dict) -> list:
|
||||||
|
"""9.3 points. THREE FIELDS, rendered at the Brussels offset for the instant."""
|
||||||
|
return [{"start": brussels(datetime.fromtimestamp(h, UTC)).isoformat(),
|
||||||
|
"eur_per_kwh": round(hours[h] / 1000.0, 6) + 0.0,
|
||||||
|
"provisional": False}
|
||||||
|
for h in sorted(hours)]
|
||||||
|
|
||||||
|
|
||||||
|
def expected_hours(start: datetime, end: datetime) -> int:
|
||||||
|
"""Whole hours in the window. Derived, rather than 8760 typed in."""
|
||||||
|
return int((end - start).total_seconds() // 3600)
|
||||||
|
|
||||||
|
|
||||||
|
def per_local_day(points) -> Counter:
|
||||||
|
"""Points per BRUSSELS calendar day - the count that exposes a DST bug."""
|
||||||
|
n = Counter()
|
||||||
|
for p in points:
|
||||||
|
n[p["start"][:10]] += 1
|
||||||
|
return n
|
||||||
|
|
||||||
|
|
||||||
|
def digest(points) -> str:
|
||||||
|
"""A checksum over the POINTS, so reformatting the envelope does not move it."""
|
||||||
|
h = hashlib.sha256()
|
||||||
|
for p in points:
|
||||||
|
h.update(f"{p['start']}|{p['eur_per_kwh']:.6f}|{int(p['provisional'])}\n"
|
||||||
|
.encode())
|
||||||
|
return h.hexdigest()
|
||||||
|
|
||||||
|
|
||||||
|
def load(path: str) -> dict:
|
||||||
|
op = gzip.open if path.endswith(".gz") else open
|
||||||
|
with op(path, "rt", encoding="utf-8") as f:
|
||||||
|
return json.load(f)
|
||||||
|
|
||||||
|
|
||||||
|
def report(doc, *, start=None, end=None) -> int:
|
||||||
|
"""Re-derive every claim the file makes about itself. Returns failures."""
|
||||||
|
pts = doc["prices"]
|
||||||
|
prov = doc["provenance"]
|
||||||
|
bad = 0
|
||||||
|
|
||||||
|
def ck(name, cond):
|
||||||
|
nonlocal bad
|
||||||
|
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||||
|
if not cond:
|
||||||
|
bad += 1
|
||||||
|
|
||||||
|
ck(f"the checksum over the {len(pts)} points matches the recorded one "
|
||||||
|
f"({prov['sha256_of_points'][:16]}...)",
|
||||||
|
digest(pts) == prov["sha256_of_points"])
|
||||||
|
ck("every point has exactly the three canonical fields and nothing else",
|
||||||
|
all(set(p) == {"start", "eur_per_kwh", "provisional"} for p in pts))
|
||||||
|
ck("every start carries a UTC offset, and it is +01:00 or +02:00 - a naive "
|
||||||
|
"timestamp here is a wall clock plus an assumption",
|
||||||
|
bool(pts) and all(p["start"][-6:] in ("+01:00", "+02:00") for p in pts))
|
||||||
|
ck("the series is strictly increasing in time, so no instant is duplicated",
|
||||||
|
all(datetime.fromisoformat(a["start"]) < datetime.fromisoformat(b["start"])
|
||||||
|
for a, b in zip(pts, pts[1:])))
|
||||||
|
ck("consecutive points are exactly one hour apart AS INSTANTS, so the two "
|
||||||
|
"02:00s of the October day are two hours rather than one",
|
||||||
|
all((datetime.fromisoformat(b["start"])
|
||||||
|
- datetime.fromisoformat(a["start"])) == timedelta(hours=1)
|
||||||
|
for a, b in zip(pts, pts[1:])))
|
||||||
|
|
||||||
|
days = per_local_day(pts)
|
||||||
|
odd = {d: n for d, n in days.items() if n != 24}
|
||||||
|
ck(f"exactly two Brussels days are not 24 hours long, and they are the "
|
||||||
|
f"transitions: {sorted(odd.items())}",
|
||||||
|
sorted(odd.values()) == [23, 25] and len(odd) == 2)
|
||||||
|
spring = [d for d, n in odd.items() if n == 23]
|
||||||
|
autumn = [d for d, n in odd.items() if n == 25]
|
||||||
|
ck(f"the 23-hour day {spring} is in March and the 25-hour day {autumn} is "
|
||||||
|
f"in October, which is the direction the EU rule actually runs",
|
||||||
|
len(spring) == 1 and len(autumn) == 1
|
||||||
|
and spring[0][5:7] == "03" and autumn[0][5:7] == "10")
|
||||||
|
if autumn:
|
||||||
|
twice = [p["start"] for p in pts
|
||||||
|
if p["start"].startswith(autumn[0] + "T02")]
|
||||||
|
ck(f"...and 02:00 on {autumn[0]} occurs TWICE at two different offsets "
|
||||||
|
f"{twice} - exactly the case a 24-slot local-hour array collapses",
|
||||||
|
len(twice) == 2 and twice[0][-6:] == "+02:00"
|
||||||
|
and twice[1][-6:] == "+01:00")
|
||||||
|
ck(f"...and the two carry DIFFERENT prices, so the 25th hour is a real "
|
||||||
|
f"observation and not the same one written down twice",
|
||||||
|
len({p["eur_per_kwh"] for p in pts
|
||||||
|
if p["start"].startswith(autumn[0] + "T02")}) == 2)
|
||||||
|
if spring:
|
||||||
|
ck(f"...and 02:00 on {spring[0]} does not occur at all, because that "
|
||||||
|
f"wall clock reading never happened in Belgium",
|
||||||
|
not any(p["start"].startswith(spring[0] + "T02") for p in pts))
|
||||||
|
|
||||||
|
if start and end:
|
||||||
|
want = expected_hours(start, end)
|
||||||
|
ck(f"{len(pts)} points for a window of {want} whole hours, and the "
|
||||||
|
f"{len(prov['gaps'])} recorded gaps account for the difference "
|
||||||
|
f"exactly", len(pts) + len(prov["gaps"]) == want)
|
||||||
|
|
||||||
|
# ⚠️ A ZERO IS NOT AUTOMATICALLY A DEFECT HERE, AND SAYING IT WAS WOULD BE
|
||||||
|
# THE WRONG LESSON. The Belgian market really does clear at 0.00 EUR/MWh in
|
||||||
|
# solar-glut hours; this window contains such hours. What must be impossible
|
||||||
|
# is a zero that arrived by COERCION - a dropped read turned into a free
|
||||||
|
# hour. That is excluded structurally rather than by outlawing the value:
|
||||||
|
# nulls are dropped, incomplete hours become gaps, and the accounting above
|
||||||
|
# shows points + gaps covering every hour of the window, so every emitted
|
||||||
|
# point stands for intervals the source actually published.
|
||||||
|
zeros = [p["start"] for p in pts if p["eur_per_kwh"] == 0.0]
|
||||||
|
ck(f"the {len(zeros)} hours priced at exactly zero match the count recorded "
|
||||||
|
f"at build time, so no zero appeared between the fetch and the file",
|
||||||
|
len(zeros) == prov["exact_zero_hours"])
|
||||||
|
ck("...and none of them is a coerced read: every emitted hour is backed by "
|
||||||
|
"published intervals, which is what the points-plus-gaps accounting "
|
||||||
|
"above establishes",
|
||||||
|
len(prov["gaps"]) == 0 or all("intervals_present" in g
|
||||||
|
for g in prov["gaps"]))
|
||||||
|
ck("the figures are declared RAW WHOLESALE, and the all-in assumption is "
|
||||||
|
"recorded as an assumption rather than applied",
|
||||||
|
prov["all_in"] is False
|
||||||
|
and "ASSUMPTION" in prov["all_in_assumption"]["status"])
|
||||||
|
return bad
|
||||||
|
|
||||||
|
|
||||||
|
def main() -> int:
|
||||||
|
ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
|
||||||
|
ap.add_argument("--start", default="2025-09-01")
|
||||||
|
ap.add_argument("--end", default="2026-09-01",
|
||||||
|
help="exclusive; both bounds are BRUSSELS-local midnights")
|
||||||
|
ap.add_argument("--out", default=None)
|
||||||
|
ap.add_argument("--verify", default=None,
|
||||||
|
help="re-derive the claims of an existing file; no network")
|
||||||
|
a = ap.parse_args()
|
||||||
|
|
||||||
|
if a.verify:
|
||||||
|
doc = load(a.verify)
|
||||||
|
print(f"verifying {a.verify}")
|
||||||
|
s = datetime.fromisoformat(doc["provenance"]["window_utc"]["start"])
|
||||||
|
e = datetime.fromisoformat(doc["provenance"]["window_utc"]["end"])
|
||||||
|
bad = report(doc, start=s, end=e)
|
||||||
|
print("OK" if not bad else f"{bad} FAILED")
|
||||||
|
return 1 if bad else 0
|
||||||
|
|
||||||
|
start = local_midnight_utc(a.start)
|
||||||
|
end = local_midnight_utc(a.end)
|
||||||
|
out = a.out or f"scenarios/epex-be-dayahead-{a.start}_{a.end}.json"
|
||||||
|
|
||||||
|
print(f"fetching {BZN} day-ahead {start.date()} .. {end.date()}",
|
||||||
|
file=sys.stderr)
|
||||||
|
raw, licences, nulls = fetch(start, end)
|
||||||
|
hours, gaps, shapes = to_hourly(raw)
|
||||||
|
pts = canonical(hours)
|
||||||
|
|
||||||
|
doc = {
|
||||||
|
"provenance": {
|
||||||
|
"card": "DATA-02",
|
||||||
|
"what": "EPEX BE day-ahead auction clearing prices, hourly",
|
||||||
|
"source": f"{API}?bzn={BZN} (Energy-Charts API, Fraunhofer ISE)",
|
||||||
|
"upstream": "Bundesnetzagentur | SMARD.de",
|
||||||
|
"licence": "CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/)",
|
||||||
|
"licence_checked": "before committing anything; the API's OpenAPI "
|
||||||
|
"document lists BE among the CC BY 4.0 zones and "
|
||||||
|
"the remaining zones as private/internal use "
|
||||||
|
"only, so redistribution of THIS zone is "
|
||||||
|
"permitted with attribution",
|
||||||
|
"licence_as_returned": sorted(licences),
|
||||||
|
"attribution": ATTRIBUTION,
|
||||||
|
"cross_check": "SMARD chart_data 4996/DE over 2026-04-10 matched "
|
||||||
|
"this feed on all 96 quarter-hours, max abs "
|
||||||
|
"difference 0.00 EUR/MWh (2026-08-31)",
|
||||||
|
"retrieved_utc": datetime.now(UTC).replace(microsecond=0).isoformat(),
|
||||||
|
"fetched_by": "scenarios/fetch_epex_be.py",
|
||||||
|
"window_utc": {"start": start.isoformat(), "end": end.isoformat()},
|
||||||
|
"unit": "EUR per kWh (source publishes EUR/MWh; divided by 1000)",
|
||||||
|
"all_in": False,
|
||||||
|
"all_in_note": "RAW WHOLESALE. No supplier markup, no network or "
|
||||||
|
"transmission tariff, no levies, no VAT. 9.3's "
|
||||||
|
"canonical point is all-in and this is NOT; the "
|
||||||
|
"consumer applies the assumption below, visibly.",
|
||||||
|
"all_in_assumption": ALL_IN_ASSUMPTION,
|
||||||
|
"resolution": {
|
||||||
|
"note": "EPEX day-ahead moved to a 15-minute market time unit "
|
||||||
|
"in Oct 2025, part-way through this window.",
|
||||||
|
"hours_from_hourly_source": shapes["hourly"],
|
||||||
|
"hours_from_quarter_hourly_mean": shapes["quarter_hourly_mean"],
|
||||||
|
"aggregation": "unweighted mean of the four quarters; a stated "
|
||||||
|
"approximation of the hourly product, and a "
|
||||||
|
"LOWER bound on the spread a 15-minute strategy "
|
||||||
|
"would have seen",
|
||||||
|
},
|
||||||
|
"timezone": "starts rendered at the Brussels offset by "
|
||||||
|
"app.price.brussels(); instants carried in UTC, so the "
|
||||||
|
"transition days come out 23 and 25 points by "
|
||||||
|
"construction rather than by a special case",
|
||||||
|
"nulls_dropped": nulls,
|
||||||
|
"gaps": gaps,
|
||||||
|
"gaps_note": "hours the source did not publish completely. Dropped, "
|
||||||
|
"never zero-filled: a missing hour is not a free hour.",
|
||||||
|
"points": len(pts),
|
||||||
|
"exact_zero_hours": sum(1 for p in pts if p["eur_per_kwh"] == 0.0),
|
||||||
|
"negative_hours": sum(1 for p in pts if p["eur_per_kwh"] < 0),
|
||||||
|
"zero_note": "REAL CLEARINGS AT 0.00 EUR/MWh, not dropped reads. "
|
||||||
|
"Nulls are dropped and incomplete hours become gaps, "
|
||||||
|
"so points + gaps == hours in the window and no point "
|
||||||
|
"stands in for something that failed to arrive.",
|
||||||
|
"sha256_of_points": digest(pts),
|
||||||
|
},
|
||||||
|
"prices": pts,
|
||||||
|
}
|
||||||
|
|
||||||
|
with open(out, "w", encoding="utf-8", newline="\n") as f:
|
||||||
|
json.dump(doc, f, indent=1, ensure_ascii=False)
|
||||||
|
f.write("\n")
|
||||||
|
print(f"wrote {out} {len(pts)} points {os.path.getsize(out)} bytes",
|
||||||
|
file=sys.stderr)
|
||||||
|
print(f"verifying {out}")
|
||||||
|
return 1 if report(doc, start=start, end=end) else 0
|
||||||
|
|
||||||
|
|
||||||
|
if __name__ == "__main__":
|
||||||
|
raise SystemExit(main())
|
||||||
@@ -20,12 +20,15 @@ WHAT THIS FILE IS DEFENDING, in the order the card's acceptance criteria name it
|
|||||||
exist - static_tariff's required `peak_guard_active` interlock and
|
exist - static_tariff's required `peak_guard_active` interlock and
|
||||||
arbiter.py's clause 2 - both driven end to end, plus the third state
|
arbiter.py's clause 2 - both driven end to end, plus the third state
|
||||||
(the guard never ran) that neither of them can express on its own.
|
(the guard never ran) that neither of them can express on its own.
|
||||||
AC4 NET-POSITIVE ACROSS 12 MONTHS OF REPLAYED PRICES. ⚠️ SEE SECTION 7. THIS
|
AC4 NET-POSITIVE ACROSS 12 MONTHS OF REPLAYED PRICES. ⚠️ MET AS OF DATA-02,
|
||||||
REPOSITORY HOLDS NO PRICE HISTORY AT ALL - `scenarios/` carries two days
|
AND SECTIONS 7 AND 7B DO DIFFERENT HALVES OF IT. 7B replays twelve months
|
||||||
of real METER data and nothing else - so the criterion as written cannot
|
of REAL EPEX BE day-ahead prices - `scenarios/epex-be-dayahead-*.json`,
|
||||||
be met, and it is NOT redefined here into something that can be. What
|
8760 hours, public data under CC BY 4.0 - through the shipped `decide()`,
|
||||||
section 7 does instead is stated there in full, and what it cannot say is
|
and reports the euro figure at the shipped threshold. Section 7 keeps the
|
||||||
stated with it.
|
SYNTHETIC year, because the real one turns out to be unable to grade §17
|
||||||
|
at all: not one of its 365 days has a negative DEAREST hour, so a count
|
||||||
|
of zero negative-price discharges over it grades nothing. 7B asserts that
|
||||||
|
degeneracy rather than quietly reporting the zero.
|
||||||
|
|
||||||
THREE RULES THIS FILE HOLDS ITSELF TO, because the reviewer will:
|
THREE RULES THIS FILE HOLDS ITSELF TO, because the reviewer will:
|
||||||
|
|
||||||
@@ -378,7 +381,11 @@ check("BUYING in a negative-price hour is still permitted - §17 forbids "
|
|||||||
"refusing to be paid to charge",
|
"refusing to be paid to charge",
|
||||||
act(NEG_PLAN, NEG.index(min(NEG)), thresh=_shipped,
|
act(NEG_PLAN, NEG.index(min(NEG)), thresh=_shipped,
|
||||||
unc=NO_WEATHER).action == CHARGE)
|
unc=NO_WEATHER).action == CHARGE)
|
||||||
# A zero price is the boundary and it is NOT negative.
|
# A zero price is the boundary and it is NOT negative. ⚠️ KEEP THIS PROBE. It
|
||||||
|
# pins the boundary from ABOVE - it is what catches a guard written `<= 0` - and
|
||||||
|
# the SAFETY-26 block below pins it from BELOW. Neither replaces the other, and
|
||||||
|
# the whole defect that card exists to close is that only one of the two sides
|
||||||
|
# was ever stated.
|
||||||
ZERO = list(POS)
|
ZERO = list(POS)
|
||||||
ZERO[DEAR_H] = 0.0
|
ZERO[DEAR_H] = 0.0
|
||||||
check("a sell hour priced at exactly ZERO is not a negative one, so the guard "
|
check("a sell hour priced at exactly ZERO is not a negative one, so the guard "
|
||||||
@@ -387,6 +394,119 @@ check("a sell hour priced at exactly ZERO is not a negative one, so the guard "
|
|||||||
act(plan_of(ZERO), DEAR_H, thresh=_shipped, unc=NO_WEATHER).action
|
act(plan_of(ZERO), DEAR_H, thresh=_shipped, unc=NO_WEATHER).action
|
||||||
== DISCHARGE)
|
== DISCHARGE)
|
||||||
|
|
||||||
|
# --------------------------------------------------------------------------- #
|
||||||
|
# SAFETY-26. THE OTHER SIDE OF THE SAME BOUNDARY, AND WHY IT HAD TO BE ADDED.
|
||||||
|
#
|
||||||
|
# OPT-04's reviewer mutated `if price < 0` to `if price < -0.001` and EVERY
|
||||||
|
# SUITE STAYED GREEN, with a -0.0005 EUR/kWh sell hour discharging. The shipped
|
||||||
|
# code was right the whole time; the CHECKS could not tell correct from
|
||||||
|
# nearly-correct, because the only probe near the boundary sat at 0.0000. A
|
||||||
|
# probe above the line catches `<=`. It says nothing at all about a tolerance
|
||||||
|
# invented below the line, and a tolerance below the line IS §17's regression
|
||||||
|
# case walking through with the suite passing.
|
||||||
|
#
|
||||||
|
# ⚠️ AND -0.0005 IS NOT AN EXOTIC INPUT. Belgian day-ahead prints small negative
|
||||||
|
# hours regularly; an all-in price a twentieth of a cent below zero is an
|
||||||
|
# ordinary day, not a fuzz value. That is what makes this a live regression
|
||||||
|
# rather than a theoretical one.
|
||||||
|
#
|
||||||
|
# ⚠️ SO THE PROBE IS A SWEEP, NOT A POINT, and the sweep is the discriminating
|
||||||
|
# part. One probe at -0.0005 closes `-0.001` and nothing else; a mutation
|
||||||
|
# reaching for `-0.01` would survive it, which is the identical defect one
|
||||||
|
# decimal place further out. The sweep spans four orders of magnitude down to
|
||||||
|
# the last place the canonical six-decimal format can even express, so there is
|
||||||
|
# no tolerance a guard can invent that some member of it does not straddle.
|
||||||
|
# `_ROUNDING` asserts the smallest member SURVIVES the format rather than being
|
||||||
|
# rounded to zero on the way in - a probe that silently became 0.0 would be the
|
||||||
|
# `0.0000` check again, wearing a different name.
|
||||||
|
TINY_NEG = (-0.05, -0.005, -0.0005, -0.00005, -0.000001)
|
||||||
|
_ROUNDING = [round(p, 6) for p in TINY_NEG]
|
||||||
|
check(f"every probe price survives the canonical 6-decimal rounding as a "
|
||||||
|
f"STRICTLY negative number {_ROUNDING} - one that rounded to 0.0 would "
|
||||||
|
f"be the check above again under another name",
|
||||||
|
all(r < 0 for r in _ROUNDING) and len(set(_ROUNDING)) == len(TINY_NEG))
|
||||||
|
check("...and they span four orders of magnitude, so no single invented "
|
||||||
|
"tolerance can sit below all of them and above none",
|
||||||
|
abs(min(TINY_NEG)) / abs(max(TINY_NEG)) > 10000)
|
||||||
|
|
||||||
|
|
||||||
|
def tiny_neg_plan(price):
|
||||||
|
"""The POS day with its DEAREST hour set to a small negative print."""
|
||||||
|
day = list(POS)
|
||||||
|
day[DEAR_H] = price
|
||||||
|
return plan_of(day), day
|
||||||
|
|
||||||
|
|
||||||
|
# The stimulus has to survive the rungs ABOVE §17 or it grades nothing: the
|
||||||
|
# hour must still be the dearest, and the spread must still clear the widened
|
||||||
|
# threshold, at every probe. Asserted first, for all of them, as its own check.
|
||||||
|
_wellformed = [
|
||||||
|
(p, day.index(max(day)) == DEAR_H,
|
||||||
|
round(max(day) - min(day), 6) > required_spread(_shipped, NO_WEATHER))
|
||||||
|
for p, (_pl, day) in ((p, tiny_neg_plan(p)) for p in TINY_NEG)]
|
||||||
|
check(f"at every probe the negative hour is still the DEAREST one and the "
|
||||||
|
f"spread still clears the threshold, so §17 is the only rung that can "
|
||||||
|
f"refuse {_wellformed}",
|
||||||
|
all(dearest and clears for _p, dearest, clears in _wellformed))
|
||||||
|
_swept = [(p, act(tiny_neg_plan(p)[0], DEAR_H, thresh=_shipped,
|
||||||
|
unc=NO_WEATHER).action) for p in TINY_NEG]
|
||||||
|
check(f"SAFETY-26: a sell hour that is negative BY ANY MARGIN AT ALL refuses - "
|
||||||
|
f"down to -0.000001 EUR/kWh, so the guard is `< 0` and not `< -epsilon` "
|
||||||
|
f"for any epsilon {_swept}",
|
||||||
|
all(a is None for _p, a in _swept))
|
||||||
|
check("...and each refusal is §17's, not some other rung that happens to fire "
|
||||||
|
"at small numbers",
|
||||||
|
all("§17" in act(tiny_neg_plan(p)[0], DEAR_H, thresh=_shipped,
|
||||||
|
unc=NO_WEATHER).reason for p in TINY_NEG))
|
||||||
|
# The mirror image, one place above zero. Without this the sweep above would
|
||||||
|
# pass for a guard that refused EVERYTHING, which grades §17 by nothing.
|
||||||
|
_tiny_pos = [(-p, act(tiny_neg_plan(-p)[0], DEAR_H, thresh=_shipped,
|
||||||
|
unc=NO_WEATHER).action) for p in TINY_NEG]
|
||||||
|
check(f"...while THE SAME MAGNITUDES with the sign flipped all DISCHARGE, so "
|
||||||
|
f"the sweep is a boundary at exactly zero rather than a refusal of small "
|
||||||
|
f"numbers - which a guard that refused everything would also have passed "
|
||||||
|
f"{_tiny_pos}",
|
||||||
|
all(a == DISCHARGE for _p, a in _tiny_pos))
|
||||||
|
|
||||||
|
# SAFETY-26 AC4 - THE LOOK AT THE OTHER BOUNDARIES, NAMED RATHER THAN FIXED.
|
||||||
|
#
|
||||||
|
# The card asks whether the same one-sided pinning exists elsewhere. Every
|
||||||
|
# price/quantity boundary in arbitrage.py and static_tariff.py was given the
|
||||||
|
# tolerance mutation that survived on `price < 0`, in both directions where
|
||||||
|
# both exist, under `-B` with a recursive purge. Two survived, BOTH in
|
||||||
|
# static_tariff.py - TARIFF-03's file, and deliberately NOT touched here:
|
||||||
|
#
|
||||||
|
# D `spread == 0.0` (the flat-tariff rung) -> `spread <= 0.001` SURVIVES.
|
||||||
|
# Measured, not reasoned: with it loosened, a series priced 0.20000 /
|
||||||
|
# 0.20050 - a REAL 0.0005 spread - flips from ALLOWED to REFUSED at
|
||||||
|
# min_spread_eur_kwh=0.0, which `arbitrage()`'s own docstring documents as
|
||||||
|
# a supported value ("pass 0.0 to mean any positive spread, explicitly").
|
||||||
|
# At a shipped threshold the OUTCOME is unchanged, but the operator's
|
||||||
|
# reason becomes the false sentence "the tariff is flat - every one of the
|
||||||
|
# 2 firm hours costs 0.2000 EUR/kWh" about a tariff that is not flat.
|
||||||
|
# Same shape as §17's: the rung is only ever probed with an EXACTLY flat
|
||||||
|
# series, so nothing pins the tiny-but-real side.
|
||||||
|
#
|
||||||
|
# F `len(firm) < 2` (§8.3's firm-pair rung) -> `< 1` SURVIVES, at +0 BYTES,
|
||||||
|
# which is the delta TEST-15 names as the risky one. It is not live on its
|
||||||
|
# own: a single firm hour has a spread of 0.0, so the flat rung refuses it
|
||||||
|
# anyway - but the reason degrades from §8.3's honest "only 1 of 3 hours
|
||||||
|
# carry a published price" to "the tariff is flat". THE FINDING THAT
|
||||||
|
# MATTERS IS THE INTERACTION: D and F MASK EACH OTHER. Neither is
|
||||||
|
# individually live because the other catches it, which is exactly the
|
||||||
|
# arrangement in which a later edit to either one opens a hole nothing
|
||||||
|
# reports.
|
||||||
|
#
|
||||||
|
# Everything else in arbitrage.py is pinned on BOTH sides and was verified so:
|
||||||
|
# `price < 0` (this card), `soc <= floor_pct` and `soc >= ceiling_pct` are each
|
||||||
|
# red under a +5 and a -5 tolerance; static_tariff's `spread < need` is red
|
||||||
|
# under +/-0.001 and additionally bisected to 1e-6 in section 1; `cheap_now`'s
|
||||||
|
# `price < mean` is red under a +0.001 tolerance in test_static_tariff.py.
|
||||||
|
#
|
||||||
|
# Not fixed here on purpose. D and F are TARIFF-03's rungs, they need probes in
|
||||||
|
# test_static_tariff.py rather than in this file, and the card is explicit that
|
||||||
|
# its fourth criterion is a look and not a refactor.
|
||||||
|
|
||||||
|
|
||||||
# --------------------------------------------------------------------------- #
|
# --------------------------------------------------------------------------- #
|
||||||
print()
|
print()
|
||||||
@@ -669,34 +789,39 @@ check("...and it is still ARMED when arbitrage is idle and the loop wins, so "
|
|||||||
print()
|
print()
|
||||||
print("7. AC4 - 12 months of replayed prices, and what could NOT be measured")
|
print("7. AC4 - 12 months of replayed prices, and what could NOT be measured")
|
||||||
|
|
||||||
# ⚠️ READ THIS BEFORE READING THE NUMBERS BELOW.
|
# ⚠️ READ THIS BEFORE READING THE NUMBERS BELOW. THIS SECTION IS THE SYNTHETIC
|
||||||
|
# YEAR, AND IT IS NOT AC4's EVIDENCE ANY MORE - SECTION 7B IS.
|
||||||
#
|
#
|
||||||
# The acceptance criterion is "net-positive across 12 months of replayed prices
|
# When OPT-04 shipped, this repository held no price history: `scenarios/`
|
||||||
# in simulation". THIS REPOSITORY CONTAINS NO PRICE HISTORY. `scenarios/` holds
|
# carried three gzipped P1 METER captures and nothing else. AC4 was therefore
|
||||||
# three gzipped captures and all three are P1 METER data - two days of net power
|
# reported NOT MET rather than redefined into something passable, which is what
|
||||||
# from the reference house plus one age capture. There is no EPEX archive, no
|
# TARIFF-01 and SAFETY-07 had both been upheld for doing.
|
||||||
# supplier export, and no CSV of a past year anywhere in the tree.
|
|
||||||
#
|
#
|
||||||
# TARIFF-01 and SAFETY-07 both hit an unmeetable criterion and both DECLINED to
|
# DATA-02 pointed out that the missing ingredient was never a capture. EPEX BE
|
||||||
# redefine it into one they could pass, and both were upheld for it. So:
|
# day-ahead is PUBLIC DATA; the 30-day meter criterion it was being carried
|
||||||
|
# beside genuinely needs waiting, and this one only ever needed a fetch. Section
|
||||||
|
# 7B replays the real year and AC4 is met there.
|
||||||
#
|
#
|
||||||
# AC4 IS NOT MET, AND IT IS NOT RESTATED. What follows is not a replay of the
|
# ⚠️ SO WHY IS THE SYNTHETIC YEAR STILL HERE? Because the real one cannot grade
|
||||||
# Belgian market; it is a replay of a SYNTHETIC year, and a euro figure from a
|
# §17, and 7B proves that rather than assuming it. Across all 365 real days, the
|
||||||
# synthetic year grades the generator that produced it, not the strategy.
|
# number whose DEAREST hour is priced below zero is ZERO - raw wholesale and
|
||||||
|
# all-in alike - so "no discharges into a negative hour" over the real year is a
|
||||||
|
# count of something that never had the chance to happen. Deleting the guard
|
||||||
|
# would not change it. This section's generator drives a summer midday block
|
||||||
|
# negative ON PURPOSE, and it is the only thing in this file that puts a
|
||||||
|
# negative price where the strategy would otherwise sell.
|
||||||
#
|
#
|
||||||
# What the replay is FOR is the half of AC4 that does not need real prices. Net
|
# What this section establishes is the half of AC4 that does not need real
|
||||||
# positivity here is not an empirical outcome to be hoped for - it is a property
|
# prices, and it is a property of the decision rule rather than an outcome to be
|
||||||
# of the decision rule, and the replay's job is to demonstrate that the property
|
# hoped for:
|
||||||
# holds on every trade the strategy actually chose, over a year of varied days
|
|
||||||
# including negative-price ones. Stated as an invariant:
|
|
||||||
#
|
#
|
||||||
# every executed round trip has (sell - buy) >= required >= threshold,
|
# every executed round trip has (sell - buy) >= required >= threshold,
|
||||||
# so its benefit net of the threshold is >= 0, on every day, always.
|
# so its benefit net of the threshold is >= 0, on every day, always.
|
||||||
#
|
#
|
||||||
# That is asserted per trade below, over 365 days. What it does NOT establish -
|
# That is asserted per trade below, over 365 varied days including negative ones.
|
||||||
# and no synthetic series could - is how OFTEN a real Belgian year clears the
|
# HOW OFTEN a real Belgian year clears the threshold is the other question, it
|
||||||
# threshold, which is the actual open question and the reason the shipped
|
# is the one the product owner's open decision turns on, and section 7B is the
|
||||||
# default is a product decision rather than a number this card picked.
|
# only place in this file that answers it.
|
||||||
|
|
||||||
def synth_day(n):
|
def synth_day(n):
|
||||||
"""A synthetic all-in day-ahead day. Deterministic, seeded by day number.
|
"""A synthetic all-in day-ahead day. Deterministic, seeded by day number.
|
||||||
@@ -803,12 +928,256 @@ check("the shipped threshold is strictly more selective than the loose one on "
|
|||||||
"the same year - the parameter does what it says, at whatever value the "
|
"the same year - the parameter does what it says, at whatever value the "
|
||||||
"owner sets it to",
|
"owner sets it to",
|
||||||
len(_sh_trades) < len(_trades))
|
len(_sh_trades) < len(_trades))
|
||||||
check("AC4 IS REPORTED AS NOT MET rather than redefined: this file says so in "
|
check("...and the shipped default was NOT moved to make any of this look "
|
||||||
"section 7's preamble, and there is no price history in the repository "
|
"better: app/arbitrage.py reads the threshold through price_option() and "
|
||||||
"to meet it with",
|
"names no number of its own",
|
||||||
not any(f.endswith((".csv", ".json.gz"))
|
"0.10" not in open(os.path.join(HERE, "app", "arbitrage.py"),
|
||||||
and "price" in f.lower()
|
encoding="utf-8").read().split('"""', 2)[2])
|
||||||
for f in os.listdir(os.path.join(HERE, "scenarios"))))
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
# --------------------------------------------------------------------------- #
|
||||||
|
print()
|
||||||
|
print("7B. AC4 - twelve months of REAL EPEX BE prices, replayed")
|
||||||
|
|
||||||
|
# THE DATASET, AND WHAT IT IS NOT.
|
||||||
|
#
|
||||||
|
# `scenarios/epex-be-dayahead-2025-09-01_2026-09-01.json` - 8760 hourly Belgian
|
||||||
|
# day-ahead auction prices, 2025-09-01 to 2026-09-01 Brussels-local, fetched by
|
||||||
|
# `scenarios/fetch_epex_be.py` from Fraunhofer ISE's Energy-Charts API, which
|
||||||
|
# publishes the BE zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de. The
|
||||||
|
# licence was checked BEFORE the data was committed, because the same API serves
|
||||||
|
# other zones under private-use-only terms; the script refuses to write a file
|
||||||
|
# whose per-response `license_info` stops saying CC BY 4.0. Provenance,
|
||||||
|
# attribution and the DST accounting live in the file's own `provenance` block
|
||||||
|
# and `fetch_epex_be.py --verify` re-derives every claim in it.
|
||||||
|
#
|
||||||
|
# ⚠️ THE FIGURES IN THAT FILE ARE RAW WHOLESALE, NOT ALL-IN, AND THIS SECTION IS
|
||||||
|
# WHERE THE DIFFERENCE IS MADE VISIBLE. §9.3's canonical point is all-in; the
|
||||||
|
# committed file says `"all_in": false` and carries the markup/tax assumption as
|
||||||
|
# NUMBERS TO APPLY rather than numbers already applied - TARIFF-02's
|
||||||
|
# double-counting trap, avoided by never baking the guess in. `_all_in()` below
|
||||||
|
# applies it in one place where a reader can watch it happen, and both replays
|
||||||
|
# are run, so exactly how much of the answer rests on the guess is reported
|
||||||
|
# rather than hidden.
|
||||||
|
|
||||||
|
import json # noqa: E402
|
||||||
|
from collections import defaultdict # noqa: E402
|
||||||
|
|
||||||
|
_DS_PATH = os.path.join(HERE, "scenarios",
|
||||||
|
"epex-be-dayahead-2025-09-01_2026-09-01.json")
|
||||||
|
_DS = derived(lambda: json.load(open(_DS_PATH, encoding="utf-8")))
|
||||||
|
_ASSUME = _DS["provenance"]["all_in_assumption"]
|
||||||
|
|
||||||
|
|
||||||
|
def _all_in(wholesale):
|
||||||
|
"""The stated assumption, applied HERE and nowhere in the committed data.
|
||||||
|
|
||||||
|
all_in = (wholesale + markup + network_and_levies) * (1 + vat), with the
|
||||||
|
coefficients read from the dataset's own provenance block rather than
|
||||||
|
retyped - a second copy is a second thing to disagree with the file.
|
||||||
|
"""
|
||||||
|
return round((wholesale + _ASSUME["markup_eur_per_kwh"]
|
||||||
|
+ _ASSUME["network_and_levies_eur_per_kwh"])
|
||||||
|
* (1.0 + _ASSUME["vat_fraction"]), 6)
|
||||||
|
|
||||||
|
|
||||||
|
def _days(price_of):
|
||||||
|
"""The dataset as Brussels calendar days of `PricePoint`s, in order.
|
||||||
|
|
||||||
|
⚠️ GROUPED BY THE LOCAL DATE IN THE `start` STRING, NOT BY SLICING 24 AT A
|
||||||
|
TIME. Two of these days are not 24 hours long, which is the whole DST check,
|
||||||
|
and a fixed stride would put October's 25th hour into the next day and
|
||||||
|
misalign every day after it.
|
||||||
|
"""
|
||||||
|
out = defaultdict(list)
|
||||||
|
for p in _DS["prices"]:
|
||||||
|
out[p["start"][:10]].append(
|
||||||
|
PricePoint(start=datetime.fromisoformat(p["start"]),
|
||||||
|
eur_per_kwh=price_of(p["eur_per_kwh"]),
|
||||||
|
provisional=bool(p["provisional"])))
|
||||||
|
return [out[k] for k in sorted(out)]
|
||||||
|
|
||||||
|
|
||||||
|
_AI_DAYS = derived(lambda: _days(_all_in))
|
||||||
|
_RAW_DAYS = derived(lambda: _days(lambda w: w))
|
||||||
|
|
||||||
|
# ---- the dataset is not degenerate, asserted BEFORE anything is graded ------
|
||||||
|
_lens = [len(d) for d in _AI_DAYS]
|
||||||
|
check(f"the replay has {len(_AI_DAYS)} Brussels days and {sum(_lens)} hourly "
|
||||||
|
f"points, which is a full year rather than a fortnight repeated",
|
||||||
|
len(_AI_DAYS) == 365 and sum(_lens) == 8760)
|
||||||
|
check(f"...and the day lengths are {sorted(set(_lens))}, so BOTH DST days are "
|
||||||
|
f"in it: an importer that produced 24 everywhere would have lost an hour "
|
||||||
|
f"in October and invented one in March",
|
||||||
|
sorted(set(_lens)) == [23, 24, 25]
|
||||||
|
and _lens.count(23) == 1 and _lens.count(25) == 1)
|
||||||
|
_dst_day = [d for d in _AI_DAYS if len(d) == 25][0]
|
||||||
|
check("...and the 25-hour day's two 02:00 points are two different INSTANTS at "
|
||||||
|
"two different offsets, which is what `at()` has to tell apart",
|
||||||
|
len({p.start for p in _dst_day}) == 25
|
||||||
|
and {p.start.utcoffset() for p in _dst_day}
|
||||||
|
== {timedelta(hours=1), timedelta(hours=2)})
|
||||||
|
|
||||||
|
_ai_spreads = sorted(round(max(p.eur_per_kwh for p in d)
|
||||||
|
- min(p.eur_per_kwh for p in d), 6)
|
||||||
|
for d in _AI_DAYS)
|
||||||
|
_raw_spreads = sorted(round(max(p.eur_per_kwh for p in d)
|
||||||
|
- min(p.eur_per_kwh for p in d), 6)
|
||||||
|
for d in _RAW_DAYS)
|
||||||
|
_req_shipped = required_spread(_shipped, NO_WEATHER)
|
||||||
|
_clears = [s for s in _ai_spreads if s > _req_shipped]
|
||||||
|
check(f"...and the year's daily spreads STRADDLE the shipped requirement of "
|
||||||
|
f"{_req_shipped:.4f} EUR/kWh - {len(_clears)} of {len(_ai_spreads)} days "
|
||||||
|
f"clear it - so the threshold is grading something. A year in which every "
|
||||||
|
f"day cleared, or none did, would grade nothing at any value",
|
||||||
|
0 < len(_clears) < len(_ai_spreads))
|
||||||
|
check(f"...and the spreads are not one repeated number: median "
|
||||||
|
f"{_ai_spreads[len(_ai_spreads) // 2]:.4f}, min {_ai_spreads[0]:.4f}, "
|
||||||
|
f"max {_ai_spreads[-1]:.4f}",
|
||||||
|
len(set(_ai_spreads)) > 300 and _ai_spreads[-1] > 4 * _ai_spreads[0])
|
||||||
|
|
||||||
|
# ---- the assumption's arithmetic, asserted rather than asserted-about -------
|
||||||
|
check("the ADDITIVE half of the all-in assumption cancels out of every daily "
|
||||||
|
"spread, so the trade counts below do not depend on the markup guess at "
|
||||||
|
"all - only on the VAT multiplier",
|
||||||
|
all(near(a, r * (1.0 + _ASSUME["vat_fraction"]), 1e-6)
|
||||||
|
for a, r in zip(_ai_spreads, _raw_spreads)))
|
||||||
|
|
||||||
|
# ---- ⚠️ THE DEGENERACY THAT KEEPS SECTION 7 ALIVE --------------------------
|
||||||
|
_raw_neg_h = sum(1 for d in _RAW_DAYS for p in d if p.eur_per_kwh < 0)
|
||||||
|
_ai_neg_h = sum(1 for d in _AI_DAYS for p in d if p.eur_per_kwh < 0)
|
||||||
|
_raw_neg_dear = sum(1 for d in _RAW_DAYS if max(p.eur_per_kwh for p in d) < 0)
|
||||||
|
_ai_neg_dear = sum(1 for d in _AI_DAYS if max(p.eur_per_kwh for p in d) < 0)
|
||||||
|
check(f"the real year DOES contain negative hours - {_raw_neg_h} of them at "
|
||||||
|
f"wholesale, {_ai_neg_h} still negative once the assumed markup and "
|
||||||
|
f"charges are added - so §17 is a live case on this market and not a "
|
||||||
|
f"hypothetical", _raw_neg_h > 100 and _ai_neg_h > 0)
|
||||||
|
check(f"BUT NOT ONE OF THE 365 DAYS HAS A NEGATIVE DEAREST HOUR "
|
||||||
|
f"({_raw_neg_dear} raw, {_ai_neg_dear} all-in), and the guard is on the "
|
||||||
|
f"hour being SOLD INTO. So a count of zero negative-price discharges over "
|
||||||
|
f"this year would be a count of something that could not happen, and "
|
||||||
|
f"section 7's synthetic year stays because it is the only thing here that "
|
||||||
|
f"puts a negative price where the strategy would sell",
|
||||||
|
_raw_neg_dear == 0 and _ai_neg_dear == 0)
|
||||||
|
|
||||||
|
|
||||||
|
def replay_real(days, threshold, unc, *, soc0=50.0, floor=20.0, ceiling=95.0):
|
||||||
|
"""The shipped `decide()` over the real year. Returns the ledger, nothing else.
|
||||||
|
|
||||||
|
One `TariffPlan` per Brussels day, so "the cheapest hour" means the cheapest
|
||||||
|
hour of that day - the same shape as section 7's replay, and the same shape
|
||||||
|
a site with a day-ahead feed actually sees.
|
||||||
|
"""
|
||||||
|
soc = soc0
|
||||||
|
trades, holdings, bad, neg_sells = [], [], [], 0
|
||||||
|
for day in days:
|
||||||
|
plan = TariffPlan(
|
||||||
|
PriceRead.series(day, PriceProduct.DAY_AHEAD, "generic_dayahead",
|
||||||
|
day[0].start), None, "provider")
|
||||||
|
open_buy = None
|
||||||
|
for p in day:
|
||||||
|
d = decide(plan, p.start + timedelta(minutes=30),
|
||||||
|
peak_guard_active=False, soc=soc,
|
||||||
|
min_spread_eur_kwh=threshold, uncertainty=unc,
|
||||||
|
charge_w=MAX_W, discharge_w=MAX_W,
|
||||||
|
soc_floor_pct=floor, soc_ceiling_pct=ceiling)
|
||||||
|
if d.action is None:
|
||||||
|
continue
|
||||||
|
if d.spread_eur_kwh is None or d.required_eur_kwh is None:
|
||||||
|
bad.append(p.start)
|
||||||
|
if d.action == CHARGE:
|
||||||
|
soc = min(ceiling, soc + STEP_PCT)
|
||||||
|
open_buy = (p.eur_per_kwh, d)
|
||||||
|
else:
|
||||||
|
if p.eur_per_kwh < 0:
|
||||||
|
neg_sells += 1
|
||||||
|
soc = max(floor, soc - STEP_PCT)
|
||||||
|
if open_buy is not None:
|
||||||
|
trades.append((open_buy[0], p.eur_per_kwh, d))
|
||||||
|
open_buy = None
|
||||||
|
else:
|
||||||
|
holdings.append(p.start)
|
||||||
|
return trades, holdings, bad, neg_sells
|
||||||
|
|
||||||
|
|
||||||
|
# ⚠️ AT THE SHIPPED THRESHOLD, UNTOUCHED, AND WIDENED BY FCST-03's NO-WEATHER
|
||||||
|
# FACTOR - the harsher of the two operating states, so the figure reported is
|
||||||
|
# the conservative one.
|
||||||
|
_r_trades, _r_held, _r_bad, _r_neg = derived(
|
||||||
|
lambda: replay_real(_AI_DAYS, _shipped, NO_WEATHER)) or (None,) * 4
|
||||||
|
_r_kwh = MAX_W / 1000.0
|
||||||
|
_r_net = round(sum((s - b - _shipped) * _r_kwh for b, s, _ in _r_trades), 2)
|
||||||
|
|
||||||
|
check(f"the real year traded at the SHIPPED threshold: {len(_r_trades)} "
|
||||||
|
f"completed round trips over 365 days of Belgian day-ahead prices - so "
|
||||||
|
f"the criterion is being graded on trades that happened, not on an empty "
|
||||||
|
f"ledger that is net-positive by vacuity", len(_r_trades) > 0)
|
||||||
|
check("...and every one of them carries the spread and the widened requirement "
|
||||||
|
"it cleared, so the ledger is auditable rather than a count", _r_bad == [])
|
||||||
|
check(f"...and it did NOT trade every day ({len(_r_trades)} round trips over "
|
||||||
|
f"365 days), so the threshold selected rather than waved everything "
|
||||||
|
f"through", len(_r_trades) < 365)
|
||||||
|
_r_losses = [(b, s) for b, s, _ in _r_trades if s - b < _shipped]
|
||||||
|
check(f"AC4: every completed round trip on the REAL year cleared the shipped "
|
||||||
|
f"{_shipped} EUR/kWh - {len(_r_losses)} exceptions of {len(_r_trades)}",
|
||||||
|
_r_losses == [])
|
||||||
|
_r_under = [d.spread_eur_kwh for _b, _s, d in _r_trades
|
||||||
|
if d.spread_eur_kwh < d.required_eur_kwh]
|
||||||
|
check(f"...and each cleared its own WIDENED requirement of "
|
||||||
|
f"{_req_shipped:.4f} EUR/kWh, which is the stricter statement §8.3 asks "
|
||||||
|
f"for", _r_under == [])
|
||||||
|
check(f"AC4 IS MET: twelve months of REAL replayed EPEX BE prices are "
|
||||||
|
f"NET-POSITIVE at the shipped default - {_r_net:+.2f} EUR of benefit net "
|
||||||
|
f"of the cycle cost over {len(_r_trades)} round trips of {_r_kwh:.1f} kWh "
|
||||||
|
f"each, accumulated from the trades the strategy actually chose",
|
||||||
|
_r_net > 0)
|
||||||
|
|
||||||
|
# ---- what the owner's open decision actually turns on -----------------------
|
||||||
|
# ⚠️ REPORTED, NOT SETTLED. `cycle_cost_threshold_eur` and FCST-03's 2.5/1.5 are
|
||||||
|
# the product owner's decision. DATA-02 supplies the input and changes nothing:
|
||||||
|
# every number below comes out of the same untouched `decide()`.
|
||||||
|
_r_calm = derived(lambda: replay_real(_AI_DAYS, _shipped, frozenset())[0])
|
||||||
|
_r_raw = derived(lambda: replay_real(_RAW_DAYS, _shipped, NO_WEATHER)[0])
|
||||||
|
# The threshold at which the MEDIAN day of this year clears its widened
|
||||||
|
# requirement. Derived from the observed spreads, not chosen.
|
||||||
|
_median_spread = _ai_spreads[len(_ai_spreads) // 2]
|
||||||
|
_suggested = round(_median_spread / widen_factor(NO_WEATHER), 4)
|
||||||
|
_r_sugg, _, _, _ = derived(
|
||||||
|
lambda: replay_real(_AI_DAYS, _suggested, NO_WEATHER)) or (None,) * 4
|
||||||
|
_sugg_net = round(sum((s - b - _suggested) * _r_kwh for b, s, _ in _r_sugg), 2)
|
||||||
|
print(f" [report] SHIPPED {_shipped} EUR/kWh, widened {widen_factor(NO_WEATHER)}x "
|
||||||
|
f"to {_req_shipped:.4f}: {len(_r_trades)} round trips, {_r_net:+.2f} EUR "
|
||||||
|
f"over the year. Unwidened (weather present): {len(_r_calm)} trips. On "
|
||||||
|
f"RAW wholesale instead of the assumed all-in: {len(_r_raw)} trips, so "
|
||||||
|
f"the markup/VAT guess moves the count by "
|
||||||
|
f"{len(_r_trades) - len(_r_raw):+d}.")
|
||||||
|
print(f" [report] the year's MEDIAN daily all-in spread is "
|
||||||
|
f"{_median_spread:.4f} EUR/kWh, so the threshold at which a median day "
|
||||||
|
f"clears its widened requirement is {_suggested} - and at that value the "
|
||||||
|
f"same year completes {len(_r_sugg)} round trips for {_sugg_net:+.2f} "
|
||||||
|
f"EUR. THE SHIPPED DEFAULT IS NOT CHANGED BY THIS CARD; both numbers are "
|
||||||
|
f"reported so the owner can decide between them.")
|
||||||
|
print(f" [report] and the four-developer finding stands unchanged: a STATIC "
|
||||||
|
f"day/night spread of ~0.0840 EUR/kWh still does not clear "
|
||||||
|
f"{_req_shipped:.4f}, so a static-tariff site never trades at the shipped "
|
||||||
|
f"default. What this year adds is that a DYNAMIC site does - on "
|
||||||
|
f"{len(_clears)} of its 365 days the spread was there to be taken.")
|
||||||
|
check("the loose threshold is strictly less selective than the shipped one on "
|
||||||
|
"the SAME real year - the parameter does what it says at whatever value "
|
||||||
|
"the owner sets, and neither run tuned anything",
|
||||||
|
len(_r_sugg) > len(_r_trades) > 0)
|
||||||
|
check(f"§17 held over the real year too ({_r_neg} discharges into a negative "
|
||||||
|
f"hour) - but see the degeneracy check above: on this data that zero is "
|
||||||
|
f"structural, and section 7's synthetic year is what actually grades the "
|
||||||
|
f"guard", _r_neg == 0)
|
||||||
|
check("the dataset carries its own provenance, states it is NOT all-in, and "
|
||||||
|
"keeps the markup/tax figures as an assumption rather than applying "
|
||||||
|
"them - the TARIFF-02 trap, in data form",
|
||||||
|
_DS["provenance"]["all_in"] is False
|
||||||
|
and "ASSUMPTION" in _ASSUME["status"]
|
||||||
|
and _DS["provenance"]["licence"].startswith("CC BY 4.0"))
|
||||||
|
|
||||||
|
|
||||||
# --------------------------------------------------------------------------- #
|
# --------------------------------------------------------------------------- #
|
||||||
|
|||||||
@@ -2,7 +2,7 @@
|
|||||||
|
|
||||||
python3 test_peakguard.py
|
python3 test_peakguard.py
|
||||||
|
|
||||||
Eight parts. What each is for, and - where it matters - what it is deliberately
|
Ten parts. What each is for, and - where it matters - what it is deliberately
|
||||||
NOT allowed to be tested at:
|
NOT allowed to be tested at:
|
||||||
|
|
||||||
1. THE CONTROL LAW, `excess_w`, graded AWAY from the two points where it is
|
1. THE CONTROL LAW, `excess_w`, graded AWAY from the two points where it is
|
||||||
@@ -36,8 +36,18 @@ NOT allowed to be tested at:
|
|||||||
6. THE REPLAY. 2026-08-20's 5029.8 W billed quarter, closed-loop, and the
|
6. THE REPLAY. 2026-08-20's 5029.8 W billed quarter, closed-loop, and the
|
||||||
healthy day's baseline. Every figure re-derived from the committed capture.
|
healthy day's baseline. Every figure re-derived from the committed capture.
|
||||||
7. THE WIRING, through the real `Controller.cycle()` and its real status page.
|
7. THE WIRING, through the real `Controller.cycle()` and its real status page.
|
||||||
8. MUTATION. Six one-line defeats of this guard, each run against the checks
|
8. SAFETY-24: THE ENERGY FLOOR under the forced discharge, graded only where
|
||||||
above to show they are not vacuous.
|
a forced discharge is actually being asked for - the SoC is a degenerate
|
||||||
|
stimulus on every cycle where `wanted <= 0`, and grading it there is how
|
||||||
|
six bugs hid in this repository this week. Includes the sweep that shows
|
||||||
|
the floor is never negative, which is the property the whole `lo`-limit
|
||||||
|
shape rests on.
|
||||||
|
9. THE EXHAUSTING REPLAY (AC 4) AND THE STARTUP REFUSAL. The same 2026-08-20
|
||||||
|
capture, against a MODELLED PACK small enough that the guard's own 878 Wh
|
||||||
|
day would take it to the BMS cut-out - so the two worlds, before and after
|
||||||
|
this card, are run against each other rather than reasoned about.
|
||||||
|
10. MUTATION. Eleven one-line defeats of these two guards, each run against
|
||||||
|
the checks above to show they are not vacuous.
|
||||||
|
|
||||||
------------------------------------------------------------------------------
|
------------------------------------------------------------------------------
|
||||||
WHAT THE REPLAY IS AND IS NOT
|
WHAT THE REPLAY IS AND IS NOT
|
||||||
@@ -66,7 +76,9 @@ support: the same quarters, with and without the guard.
|
|||||||
|
|
||||||
import asyncio
|
import asyncio
|
||||||
import ast
|
import ast
|
||||||
|
import dataclasses
|
||||||
import gzip
|
import gzip
|
||||||
|
import inspect
|
||||||
import json
|
import json
|
||||||
import re
|
import re
|
||||||
import shutil
|
import shutil
|
||||||
@@ -89,9 +101,11 @@ from app.p1 import (
|
|||||||
)
|
)
|
||||||
from app.peakguard import (
|
from app.peakguard import (
|
||||||
BLIND_COVERAGE, BLIND_FROZEN, BLIND_NO_BLOCK, CEILING_CAP,
|
BLIND_COVERAGE, BLIND_FROZEN, BLIND_NO_BLOCK, CEILING_CAP,
|
||||||
CEILING_MONTH_PEAK, PeakDecision, blindness, decide, excess_w,
|
CEILING_MONTH_PEAK, FLOOR_AT_SOC_FLOOR, FLOOR_SOC_UNREADABLE,
|
||||||
quarter_ceiling_w, uncovered_s,
|
PEAK_OPTION_DEFAULTS, PeakDecision, blindness, decide, discharge_permitted,
|
||||||
|
excess_w, quarter_ceiling_w, uncovered_s,
|
||||||
)
|
)
|
||||||
|
from app.validate import validate_startup_config
|
||||||
from app.tariff import (
|
from app.tariff import (
|
||||||
NOT_OBSERVED, NO_RECORD, OBSERVED, PeakReading, PeakStore, PeakTracker,
|
NOT_OBSERVED, NO_RECORD, OBSERVED, PeakReading, PeakStore, PeakTracker,
|
||||||
month_key,
|
month_key,
|
||||||
@@ -166,13 +180,29 @@ CYCLE_S = read_option("cycle_floor_s")
|
|||||||
# ceiling and the GW5000S-BP's rating, which is why the two agree - so the
|
# ceiling and the GW5000S-BP's rating, which is why the two agree - so the
|
||||||
# device figure is taken from the schema rather than typed.
|
# device figure is taken from the schema rather than typed.
|
||||||
LIVE_MAX_W = read_schema_max("max_w")
|
LIVE_MAX_W = read_schema_max("max_w")
|
||||||
|
# SAFETY-24's two options, out of the shipped file for the same reason.
|
||||||
|
SOC_FLOOR = read_option("peak_soc_floor")
|
||||||
|
BMS_FLOOR = read_option("bms_soc_floor")
|
||||||
|
MAINT_FLOOR = read_option("maintenance_soc_floor")
|
||||||
|
# A state of charge that comfortably permits a forced discharge, DERIVED from
|
||||||
|
# the floor rather than typed: every part of this file that is not about
|
||||||
|
# SAFETY-24 has to grade SAFETY-07's behaviour at a SoC where the new floor is
|
||||||
|
# not the thing deciding the answer, or it would be measuring the wrong guard.
|
||||||
|
SOC_OK = SOC_FLOOR + 30.0
|
||||||
|
|
||||||
print("SAFETY-07 - the quarter-peak projection guard")
|
print("SAFETY-07 - the quarter-peak projection guard")
|
||||||
|
print("SAFETY-24 - and the energy floor under its forced discharge")
|
||||||
print(f" read from config.yaml: peak_cap_w {CAP_W:.0f} W, "
|
print(f" read from config.yaml: peak_cap_w {CAP_W:.0f} W, "
|
||||||
f"meter_max_age_s {MAX_HOLD_S:.0f} s, meter_freeze_s {FREEZE_S:.0f} s, "
|
f"meter_max_age_s {MAX_HOLD_S:.0f} s, meter_freeze_s {FREEZE_S:.0f} s, "
|
||||||
f"cycle_floor_s {CYCLE_S:.0f} s, max_w schema ceiling {LIVE_MAX_W:.0f} W")
|
f"cycle_floor_s {CYCLE_S:.0f} s, max_w schema ceiling {LIVE_MAX_W:.0f} W")
|
||||||
|
print(f" ...and peak_soc_floor {SOC_FLOOR:.0f} %, bms_soc_floor "
|
||||||
|
f"{BMS_FLOOR:.0f} %, maintenance_soc_floor {MAINT_FLOOR:.0f} %")
|
||||||
check("every threshold this check grades against came out of config.yaml",
|
check("every threshold this check grades against came out of config.yaml",
|
||||||
None not in (CAP_W, MAX_HOLD_S, FREEZE_S, CYCLE_S, LIVE_MAX_W))
|
None not in (CAP_W, MAX_HOLD_S, FREEZE_S, CYCLE_S, LIVE_MAX_W,
|
||||||
|
SOC_FLOOR, BMS_FLOOR, MAINT_FLOOR))
|
||||||
|
check("...and the SoC these checks use as 'plenty of battery' is comfortably "
|
||||||
|
"clear of the floor, so nothing outside part 9 is silently grading "
|
||||||
|
"SAFETY-24 instead of SAFETY-07", SOC_OK > SOC_FLOOR + 10.0)
|
||||||
|
|
||||||
B = datetime(2026, 8, 30, 9, 0, 0, tzinfo=timezone.utc) # a quarter boundary
|
B = datetime(2026, 8, 30, 9, 0, 0, tzinfo=timezone.utc) # a quarter boundary
|
||||||
|
|
||||||
@@ -239,7 +269,7 @@ BATT_NOW = 400.0
|
|||||||
a_edge = averager_at(CEIL, 450.0)
|
a_edge = averager_at(CEIL, 450.0)
|
||||||
p_edge = PeakTracker.project(a_edge, B + timedelta(seconds=450))
|
p_edge = PeakTracker.project(a_edge, B + timedelta(seconds=450))
|
||||||
d_edge = decide(p_edge, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
d_edge = decide(p_edge, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
e_edge = excess_w(p_edge, CEIL)
|
e_edge = excess_w(p_edge, CEIL)
|
||||||
print(f" held exactly AT the ceiling for 450 s: projected "
|
print(f" held exactly AT the ceiling for 450 s: projected "
|
||||||
f"{p_edge.projected_w:.2f} W, excess {e_edge:.3f} W, "
|
f"{p_edge.projected_w:.2f} W, excess {e_edge:.3f} W, "
|
||||||
@@ -254,7 +284,7 @@ check("at the engagement boundary the excess is zero, so the floor is exactly "
|
|||||||
# released as soon as `excess <= 0` hands the actuator back at the exact instant
|
# released as soon as `excess <= 0` hands the actuator back at the exact instant
|
||||||
# it is working, and the load springs straight back.
|
# it is working, and the load springs straight back.
|
||||||
released = decide(p_edge, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
released = decide(p_edge, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
would_release_on_excess = excess_w(p_edge, CEIL) <= 0.0
|
would_release_on_excess = excess_w(p_edge, CEIL) <= 0.0
|
||||||
print(f" at the boundary: excess {e_edge:.3f} W (an `excess > 0` test would "
|
print(f" at the boundary: excess {e_edge:.3f} W (an `excess > 0` test would "
|
||||||
f"RELEASE: {would_release_on_excess}), floor {released.floor_w:.0f} W "
|
f"RELEASE: {would_release_on_excess}), floor {released.floor_w:.0f} W "
|
||||||
@@ -266,7 +296,7 @@ check("...and the claim is held there, not released. `excess` falls to zero as "
|
|||||||
d_gone = decide(PeakTracker.project(averager_at(500.0, 450.0),
|
d_gone = decide(PeakTracker.project(averager_at(500.0, 450.0),
|
||||||
B + timedelta(seconds=450)),
|
B + timedelta(seconds=450)),
|
||||||
batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
check("...and it DOES release once the load falls under what the quarter can "
|
check("...and it DOES release once the load falls under what the quarter can "
|
||||||
"afford, so 'threshold the floor' is not 'never let go'",
|
"afford, so 'threshold the floor' is not 'never let go'",
|
||||||
not d_gone.engaged and d_gone.floor_w is None)
|
not d_gone.engaged and d_gone.floor_w is None)
|
||||||
@@ -275,7 +305,7 @@ check("...and it DOES release once the load falls under what the quarter can "
|
|||||||
a_over = averager_at(CEIL + 200.0, 450.0)
|
a_over = averager_at(CEIL + 200.0, 450.0)
|
||||||
p_over = PeakTracker.project(a_over, B + timedelta(seconds=450))
|
p_over = PeakTracker.project(a_over, B + timedelta(seconds=450))
|
||||||
d_over = decide(p_over, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
d_over = decide(p_over, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
print(f" 200 W over for 450 s: {d_over.explain()}")
|
print(f" 200 W over for 450 s: {d_over.explain()}")
|
||||||
check("a quarter projected over the ceiling engages, and the floor is the "
|
check("a quarter projected over the ceiling engages, and the floor is the "
|
||||||
"MEASURED battery power plus the derived excess",
|
"MEASURED battery power plus the derived excess",
|
||||||
@@ -284,7 +314,7 @@ check("a quarter projected over the ceiling engages, and the floor is the "
|
|||||||
check("...and the floor moves with the battery measurement, so it is a claim "
|
check("...and the floor moves with the battery measurement, so it is a claim "
|
||||||
"about delivered power rather than a fixed setpoint",
|
"about delivered power rather than a fixed setpoint",
|
||||||
not near(decide(p_over, batt_w=BATT_NOW + 250.0, cap_w=CAP_W, reading=None,
|
not near(decide(p_over, batt_w=BATT_NOW + 250.0, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S).floor_w,
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR).floor_w,
|
||||||
d_over.floor_w, 1.0))
|
d_over.floor_w, 1.0))
|
||||||
|
|
||||||
# THE WIND-UP ARGUMENT, made concrete. A floor built on INTENT re-adds its own
|
# THE WIND-UP ARGUMENT, made concrete. A floor built on INTENT re-adds its own
|
||||||
@@ -295,7 +325,7 @@ delivered_floor = []
|
|||||||
intent_floor = []
|
intent_floor = []
|
||||||
for _ in range(5):
|
for _ in range(5):
|
||||||
d_del = decide(p_over, batt_w=stuck_batt, cap_w=CAP_W, reading=None,
|
d_del = decide(p_over, batt_w=stuck_batt, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
delivered_floor.append(d_del.floor_w)
|
delivered_floor.append(d_del.floor_w)
|
||||||
intent = intent + excess_w(p_over, CEIL) # what the intent form would do
|
intent = intent + excess_w(p_over, CEIL) # what the intent form would do
|
||||||
intent_floor.append(intent)
|
intent_floor.append(intent)
|
||||||
@@ -378,7 +408,7 @@ absurd = averager_at(LIVE_MAX_W * 4, 870.0)
|
|||||||
p_absurd = PeakTracker.project(absurd, B + timedelta(seconds=870))
|
p_absurd = PeakTracker.project(absurd, B + timedelta(seconds=870))
|
||||||
DEV_MAX = LIVE_MAX_W - 500.0 # a device rating tighter than max_w
|
DEV_MAX = LIVE_MAX_W - 500.0 # a device rating tighter than max_w
|
||||||
d_absurd = decide(p_absurd, batt_w=1000.0, cap_w=CAP_W, reading=None,
|
d_absurd = decide(p_absurd, batt_w=1000.0, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=min(LIVE_MAX_W, DEV_MAX), max_hold_s=MAX_HOLD_S)
|
achievable_w=min(LIVE_MAX_W, DEV_MAX), max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
r6 = resolve([Claim.limit("device", P_SAFETY, -DEV_MAX, DEV_MAX, "rating"),
|
r6 = resolve([Claim.limit("device", P_SAFETY, -DEV_MAX, DEV_MAX, "rating"),
|
||||||
Claim.limit("supervised", P_SAFETY, -LIVE_MAX_W, LIVE_MAX_W, "max_w"),
|
Claim.limit("supervised", P_SAFETY, -LIVE_MAX_W, LIVE_MAX_W, "max_w"),
|
||||||
Claim.set("loop", P_LOOP, -200.0, "grid"),
|
Claim.set("loop", P_LOOP, -200.0, "grid"),
|
||||||
@@ -461,7 +491,7 @@ print(f" a real PeakStore on a missing volume: state={rd_broken.state}, "
|
|||||||
check("the real store answers NOT_OBSERVED rather than a peak of 0 W",
|
check("the real store answers NOT_OBSERVED rather than a peak of 0 W",
|
||||||
rd_broken.state == NOT_OBSERVED and rd_broken.peak_w is None)
|
rd_broken.state == NOT_OBSERVED and rd_broken.peak_w is None)
|
||||||
d_broken = decide(p_over, batt_w=BATT_NOW, cap_w=CAP_W, reading=rd_broken,
|
d_broken = decide(p_over, batt_w=BATT_NOW, cap_w=CAP_W, reading=rd_broken,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
print(f" {d_broken.explain()}")
|
print(f" {d_broken.explain()}")
|
||||||
check("AND THE GUARD STILL ENGAGES ON IT. An unreadable peak must not disarm "
|
check("AND THE GUARD STILL ENGAGES ON IT. An unreadable peak must not disarm "
|
||||||
"the cap - 'no peak recorded' is precisely the reading that would, and it "
|
"the cap - 'no peak recorded' is precisely the reading that would, and it "
|
||||||
@@ -489,7 +519,7 @@ print("4. blindness: three ways a projection is not evidence")
|
|||||||
fresh = QuarterAverager(phases=1, max_hold_s=MAX_HOLD_S)
|
fresh = QuarterAverager(phases=1, max_hold_s=MAX_HOLD_S)
|
||||||
p_fresh = PeakTracker.project(fresh, B)
|
p_fresh = PeakTracker.project(fresh, B)
|
||||||
d_fresh = decide(p_fresh, batt_w=0.0, cap_w=CAP_W, reading=None,
|
d_fresh = decide(p_fresh, batt_w=0.0, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
print(f" fresh averager: projected {p_fresh.projected_w:.0f} W, "
|
print(f" fresh averager: projected {p_fresh.projected_w:.0f} W, "
|
||||||
f"block_start={p_fresh.block_start}; {d_fresh.explain()}")
|
f"block_start={p_fresh.block_start}; {d_fresh.explain()}")
|
||||||
check("a fresh averager's projection is 0 W, i.e. comfortably under any "
|
check("a fresh averager's projection is 0 W, i.e. comfortably under any "
|
||||||
@@ -517,7 +547,7 @@ RAILED = LIVE_MAX_W # the loop has wound to the rail
|
|||||||
is_frozen = looks_frozen(FREEZE_S + 1.0, -RAILED, LIVE_MAX_W,
|
is_frozen = looks_frozen(FREEZE_S + 1.0, -RAILED, LIVE_MAX_W,
|
||||||
FreezeWatchdogConfig(hold_s=FREEZE_S))
|
FreezeWatchdogConfig(hold_s=FREEZE_S))
|
||||||
d_frozen = decide(p_frozen, batt_w=-RAILED, cap_w=CAP_W, reading=None,
|
d_frozen = decide(p_frozen, batt_w=-RAILED, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR,
|
||||||
frozen=is_frozen)
|
frozen=is_frozen)
|
||||||
print(f" meter stuck at -4000 W with the command at {-RAILED:+.0f} W: "
|
print(f" meter stuck at -4000 W with the command at {-RAILED:+.0f} W: "
|
||||||
f"projected {p_frozen.projected_w:.0f} W, coverage "
|
f"projected {p_frozen.projected_w:.0f} W, coverage "
|
||||||
@@ -543,7 +573,7 @@ check("...and the same command NOT frozen is left alone, so the blind branch is
|
|||||||
peakguard.claim(decide(
|
peakguard.claim(decide(
|
||||||
p_frozen, batt_w=-RAILED, cap_w=CAP_W,
|
p_frozen, batt_w=-RAILED, cap_w=CAP_W,
|
||||||
reading=None, achievable_w=LIVE_MAX_W,
|
reading=None, achievable_w=LIVE_MAX_W,
|
||||||
max_hold_s=MAX_HOLD_S, frozen=False))
|
max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR, frozen=False))
|
||||||
or Claim.limit("noop", P_PEAK)]).target_w,
|
or Claim.limit("noop", P_PEAK)]).target_w,
|
||||||
-RAILED, 1e-9))
|
-RAILED, 1e-9))
|
||||||
|
|
||||||
@@ -554,7 +584,7 @@ p_gap = PeakTracker.project(gapped, B + timedelta(seconds=600))
|
|||||||
clean = averager_at(4200.0, 600.0)
|
clean = averager_at(4200.0, 600.0)
|
||||||
p_clean = PeakTracker.project(clean, B + timedelta(seconds=600))
|
p_clean = PeakTracker.project(clean, B + timedelta(seconds=600))
|
||||||
d_gap = decide(p_gap, batt_w=0.0, cap_w=CAP_W, reading=None,
|
d_gap = decide(p_gap, batt_w=0.0, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
print(f" a {GAP:.0f} s hole at 4200 W: uncovered {uncovered_s(p_gap):.0f} s, "
|
print(f" a {GAP:.0f} s hole at 4200 W: uncovered {uncovered_s(p_gap):.0f} s, "
|
||||||
f"projected {p_gap.projected_w:.0f} W vs {p_clean.projected_w:.0f} W with "
|
f"projected {p_gap.projected_w:.0f} W vs {p_clean.projected_w:.0f} W with "
|
||||||
f"no hole")
|
f"no hole")
|
||||||
@@ -618,7 +648,7 @@ OLD = (p_held.partial_ws if hasattr(p_held, "partial_ws")
|
|||||||
else HELD * 300.0) # acc, which the old form would still have had
|
else HELD * 300.0) # acc, which the old form would still have had
|
||||||
old_projected = (HELD * 300.0 + 0.0 * (QUARTER_S - 300.0)) / QUARTER_S
|
old_projected = (HELD * 300.0 + 0.0 * (QUARTER_S - 300.0)) / QUARTER_S
|
||||||
d_true = decide(p_held, batt_w=0.0, cap_w=CAP_W, reading=None,
|
d_true = decide(p_held, batt_w=0.0, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S)
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR)
|
||||||
print(f" same fixture: shipped projection {p_held.projected_w:.0f} W "
|
print(f" same fixture: shipped projection {p_held.projected_w:.0f} W "
|
||||||
f"(engaged={d_true.engaged}), the defaulted form's "
|
f"(engaged={d_true.engaged}), the defaulted form's "
|
||||||
f"{old_projected:.0f} W (would engage={old_projected > CAP_W})")
|
f"{old_projected:.0f} W (would engage={old_projected > CAP_W})")
|
||||||
@@ -636,24 +666,55 @@ REPLAY = sorted((HERE / "scenarios").glob("p1-net-*.jsonl.gz"))
|
|||||||
check("the committed replay fixtures are present", len(REPLAY) >= 2)
|
check("the committed replay fixtures are present", len(REPLAY) >= 2)
|
||||||
|
|
||||||
|
|
||||||
def replay(path, *, guarded: bool, cap_w=CAP_W, max_w=LIVE_MAX_W):
|
def replay(path, *, guarded: bool, cap_w=CAP_W, max_w=LIVE_MAX_W, pack=None,
|
||||||
|
soc_floor=None):
|
||||||
"""Drive one capture through the real ingest, tracker and guard.
|
"""Drive one capture through the real ingest, tracker and guard.
|
||||||
|
|
||||||
See the module docstring for the model and why its baseline is pessimistic.
|
See the module docstring for the model and why its baseline is pessimistic.
|
||||||
|
|
||||||
|
⚠️ SAFETY-24's `pack` IS A SECOND MODEL, AND IT IS STATED HERE RATHER THAN
|
||||||
|
HIDDEN. The captures carry meter power only, so the pack is simulated:
|
||||||
|
|
||||||
|
pack = (usable_wh, start_soc_pct, bms_floor_pct)
|
||||||
|
|
||||||
|
* SoC falls by the DELIVERED discharge, integrated over the real telegram
|
||||||
|
timestamps - the same integral that already produces `wh`, so the two
|
||||||
|
cannot disagree;
|
||||||
|
* the BMS is modelled as a HARD CUT at `bms_floor_pct`: at or below it the
|
||||||
|
modelled battery delivers 0 W whatever the guard asks for. Without that,
|
||||||
|
the "before this card" run would be unphysical and its comparison
|
||||||
|
worthless - the BMS really does stop the pack, and the finding this card
|
||||||
|
answers is that it is then the ONLY thing that does;
|
||||||
|
* nothing recharges the pack. One day, one direction. That is pessimistic
|
||||||
|
in the same deliberate way the zero-baseline discharge is: it isolates
|
||||||
|
what the peak guard alone spends.
|
||||||
|
|
||||||
|
`pack=None` pins the SoC at SOC_OK and reproduces SAFETY-07's numbers
|
||||||
|
exactly, which is what parts 6's existing checks grade.
|
||||||
"""
|
"""
|
||||||
ing = P1Ingest(phases=1, max_age_s=MAX_HOLD_S)
|
ing = P1Ingest(phases=1, max_age_s=MAX_HOLD_S)
|
||||||
store = fresh_store(f"{path.stem}-{'g' if guarded else 'u'}")
|
store = fresh_store(f"{path.stem}-{'g' if guarded else 'u'}"
|
||||||
|
f"{'' if pack is None else f'-p{soc_floor:.0f}'}")
|
||||||
tracker = PeakTracker(store, cap_w=cap_w)
|
tracker = PeakTracker(store, cap_w=cap_w)
|
||||||
batt = 0.0 # delivered discharge, W (positive)
|
batt = 0.0 # delivered discharge, W (positive)
|
||||||
next_cycle = None
|
next_cycle = None
|
||||||
graded_engaged = blind_engaged = saturated = cycles = 0
|
graded_engaged = blind_engaged = saturated = cycles = 0
|
||||||
|
limited = at_bms = neg_floor = 0
|
||||||
wh = 0.0
|
wh = 0.0
|
||||||
prev_t = None
|
prev_t = None
|
||||||
|
usable_wh, soc, bms = (None, SOC_OK, None) if pack is None else (
|
||||||
|
float(pack[0]), float(pack[1]), float(pack[2]))
|
||||||
|
floor_pct = SOC_FLOOR if soc_floor is None else float(soc_floor)
|
||||||
|
min_soc = soc
|
||||||
for line in gzip.open(path, "rt", encoding="utf-8"):
|
for line in gzip.open(path, "rt", encoding="utf-8"):
|
||||||
row = json.loads(line)
|
row = json.loads(line)
|
||||||
t = datetime.fromisoformat(row["t"])
|
t = datetime.fromisoformat(row["t"])
|
||||||
if prev_t is not None:
|
if prev_t is not None:
|
||||||
wh += batt * (t - prev_t).total_seconds() / 3600.0
|
dwh = batt * (t - prev_t).total_seconds() / 3600.0
|
||||||
|
wh += dwh
|
||||||
|
if usable_wh:
|
||||||
|
soc = max(0.0, soc - 100.0 * dwh / usable_wh)
|
||||||
|
min_soc = min(min_soc, soc)
|
||||||
prev_t = t
|
prev_t = t
|
||||||
ing.submit(sample(t, float(row["w"]) - batt))
|
ing.submit(sample(t, float(row["w"]) - batt))
|
||||||
tracker.sync(ing)
|
tracker.sync(ing)
|
||||||
@@ -663,7 +724,10 @@ def replay(path, *, guarded: bool, cap_w=CAP_W, max_w=LIVE_MAX_W):
|
|||||||
cycles += 1
|
cycles += 1
|
||||||
d = decide(PeakTracker.project(ing.averager, t),
|
d = decide(PeakTracker.project(ing.averager, t),
|
||||||
batt_w=batt, cap_w=cap_w, reading=tracker.peak(t),
|
batt_w=batt, cap_w=cap_w, reading=tracker.peak(t),
|
||||||
achievable_w=max_w, max_hold_s=MAX_HOLD_S, frozen=False)
|
achievable_w=max_w, max_hold_s=MAX_HOLD_S, soc=soc,
|
||||||
|
soc_floor=floor_pct, frozen=False)
|
||||||
|
if d.floor_w is not None and d.floor_w < 0.0:
|
||||||
|
neg_floor += 1
|
||||||
if d.engaged:
|
if d.engaged:
|
||||||
(globals(), None)
|
(globals(), None)
|
||||||
if d.blind:
|
if d.blind:
|
||||||
@@ -671,15 +735,25 @@ def replay(path, *, guarded: bool, cap_w=CAP_W, max_w=LIVE_MAX_W):
|
|||||||
else:
|
else:
|
||||||
graded_engaged += 1
|
graded_engaged += 1
|
||||||
saturated += 1 if d.saturated else 0
|
saturated += 1 if d.saturated else 0
|
||||||
|
limited += 1 if d.floor_limited else 0
|
||||||
|
if usable_wh and soc <= bms:
|
||||||
|
at_bms += 1
|
||||||
if not guarded:
|
if not guarded:
|
||||||
continue
|
continue
|
||||||
batt = max(0.0, d.floor_w) if (d.engaged and d.floor_w is not None) else 0.0
|
batt = max(0.0, d.floor_w) if (d.engaged and d.floor_w is not None) else 0.0
|
||||||
|
# THE BMS, MODELLED. It is a real floor and it works - that is the whole
|
||||||
|
# point of stating the risk fairly - so the "before" world is not a pack
|
||||||
|
# discharged to nothing, it is a pack pinned at the BMS limit.
|
||||||
|
if usable_wh and soc <= bms:
|
||||||
|
batt = 0.0
|
||||||
month = month_key(datetime.fromisoformat(json.loads(
|
month = month_key(datetime.fromisoformat(json.loads(
|
||||||
gzip.open(path, "rt", encoding="utf-8").readline())["t"]))
|
gzip.open(path, "rt", encoding="utf-8").readline())["t"]))
|
||||||
return {
|
return {
|
||||||
"blocks": dict(store.blocks_in(month)), "cycles": cycles,
|
"blocks": dict(store.blocks_in(month)), "cycles": cycles,
|
||||||
"graded": graded_engaged, "blind": blind_engaged,
|
"graded": graded_engaged, "blind": blind_engaged,
|
||||||
"saturated": saturated, "wh": wh, "month": month,
|
"saturated": saturated, "wh": wh, "month": month,
|
||||||
|
"limited": limited, "at_bms": at_bms, "neg_floor": neg_floor,
|
||||||
|
"end_soc": soc, "min_soc": min_soc,
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -872,7 +946,7 @@ check("...and the status page says NOT COVERED rather than 'idle' or a green "
|
|||||||
# Controller rather than left to flake. It is bounded at three attempts: a fourth
|
# Controller rather than left to flake. It is bounded at three attempts: a fourth
|
||||||
# would mean something is wrong that is not a boundary.
|
# would mean something is wrong that is not a boundary.
|
||||||
def wired_over_limit(db, want_floor_w, opts=None, store=None, batt_w=0.0,
|
def wired_over_limit(db, want_floor_w, opts=None, store=None, batt_w=0.0,
|
||||||
standing_w=None):
|
standing_w=None, soc=55.0):
|
||||||
"""A real Controller driven one real cycle over a real over-limit quarter.
|
"""A real Controller driven one real cycle over a real over-limit quarter.
|
||||||
|
|
||||||
⚠️ THE LOAD IS DERIVED FROM WHERE IN THE QUARTER THE WALL CLOCK LANDS, and
|
⚠️ THE LOAD IS DERIVED FROM WHERE IN THE QUARTER THE WALL CLOCK LANDS, and
|
||||||
@@ -886,7 +960,7 @@ def wired_over_limit(db, want_floor_w, opts=None, store=None, batt_w=0.0,
|
|||||||
for attempt in range(4):
|
for attempt in range(4):
|
||||||
ctl, hs = built(db if attempt == 0 else Path(f"{db}.{attempt}"), opts,
|
ctl, hs = built(db if attempt == 0 else Path(f"{db}.{attempt}"), opts,
|
||||||
store=_Store(store) if store is not None else None)
|
store=_Store(store) if store is not None else None)
|
||||||
ctl.auto, ctl.soc, ctl.batt = True, 55.0, batt_w
|
ctl.auto, ctl.soc, ctl.batt = True, soc, batt_w
|
||||||
ctl.dev_min, ctl.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
ctl.dev_min, ctl.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||||
if standing_w is not None:
|
if standing_w is not None:
|
||||||
# The command STANDING ON THE WIRE, which is what B3 below needs to
|
# The command STANDING ON THE WIRE, which is what B3 below needs to
|
||||||
@@ -911,6 +985,9 @@ def wired_over_limit(db, want_floor_w, opts=None, store=None, batt_w=0.0,
|
|||||||
ctl.cycle())
|
ctl.cycle())
|
||||||
g = ctl.peak_guard
|
g = ctl.peak_guard
|
||||||
if g is not None and g.engaged and not g.blind:
|
if g is not None and g.engaged and not g.blind:
|
||||||
|
# ⚠️ A FLOOR-LIMITED DECISION IS A LANDING, NOT A MISS. It is
|
||||||
|
# `engaged` and not `blind`, which is what this loop is waiting for;
|
||||||
|
# SAFETY-24's own fixtures below arrive here on purpose.
|
||||||
return ctl, hs, net_w, remaining
|
return ctl, hs, net_w, remaining
|
||||||
# Only a quarter boundary crossed between the last telegram and
|
# Only a quarter boundary crossed between the last telegram and
|
||||||
# `cycle()`'s own clock gets here. Bounded at four: a fifth would mean
|
# `cycle()`'s own clock gets here. Bounded at four: a fifth would mean
|
||||||
@@ -1094,7 +1171,8 @@ check("B3: main.py sizes the floor from the MEASURED battery power, not from "
|
|||||||
# judged at a single point where they need not differ.
|
# judged at a single point where they need not differ.
|
||||||
_proj3 = PeakTracker.project(b3.p1.averager, datetime.now(timezone.utc))
|
_proj3 = PeakTracker.project(b3.p1.averager, datetime.now(timezone.utc))
|
||||||
_kw = dict(cap_w=CAP_W, reading=b3.peak.peak(), achievable_w=LIVE_MAX_W,
|
_kw = dict(cap_w=CAP_W, reading=b3.peak.peak(), achievable_w=LIVE_MAX_W,
|
||||||
max_hold_s=b3.p1.averager.max_hold_s)
|
max_hold_s=b3.p1.averager.max_hold_s, soc=SOC_OK,
|
||||||
|
soc_floor=SOC_FLOOR)
|
||||||
_intent = _shipped_decide(_proj3, batt_w=STANDING, **_kw)
|
_intent = _shipped_decide(_proj3, batt_w=STANDING, **_kw)
|
||||||
check("one cycle of the intent form is exactly the delivered form plus the "
|
check("one cycle of the intent form is exactly the delivered form plus the "
|
||||||
"command standing on the wire - which is the whole defect in one line: "
|
"command standing on the wire - which is the whole defect in one line: "
|
||||||
@@ -1127,14 +1205,56 @@ check("...and the consequence is the wind-up part 1 demonstrates, now on the "
|
|||||||
and not b3.peak_guard.saturated)
|
and not b3.peak_guard.saturated)
|
||||||
# Graded on the parsed call syntax too, so a rename cannot quietly reintroduce
|
# Graded on the parsed call syntax too, so a rename cannot quietly reintroduce
|
||||||
# it: the keyword main.py passes must be the measured attribute.
|
# it: the keyword main.py passes must be the measured attribute.
|
||||||
_call = next(n for n in ast.walk(ast.parse(_mainsrc))
|
# ⚠️ SELECTED BY QUALIFIED NAME, NOT BY BEING FIRST. This took the first
|
||||||
|
# `.decide(` in main.py and asserted there was only one - which was true when
|
||||||
|
# SAFETY-24 was written and STOPPED BEING TRUE when OPT-04 added
|
||||||
|
# `arbitrage.decide(...)`. Grading "whichever .decide() the AST walk reaches
|
||||||
|
# first" is exactly the fragility a reviewer flagged on SAFETY-07: it grades a
|
||||||
|
# position, not the call. `peakguard.decide` is what this file is about, so name
|
||||||
|
# it, and require exactly one of THAT.
|
||||||
|
_peak_calls = [n for n in ast.walk(ast.parse(_mainsrc))
|
||||||
if isinstance(n, ast.Call) and isinstance(n.func, ast.Attribute)
|
if isinstance(n, ast.Call) and isinstance(n.func, ast.Attribute)
|
||||||
and n.func.attr == "decide")
|
and n.func.attr == "decide"
|
||||||
|
and isinstance(n.func.value, ast.Name)
|
||||||
|
and n.func.value.id == "peakguard"]
|
||||||
|
_call = _peak_calls[0]
|
||||||
_batt_src = ast.unparse(next(k.value for k in _call.keywords if k.arg == "batt_w"))
|
_batt_src = ast.unparse(next(k.value for k in _call.keywords if k.arg == "batt_w"))
|
||||||
print(f" main.py's decide(batt_w=...) is `{_batt_src}`")
|
_soc_src = ast.unparse(next(k.value for k in _call.keywords if k.arg == "soc"))
|
||||||
|
print(f" main.py's decide(batt_w=...) is `{_batt_src}`, decide(soc=...) is "
|
||||||
|
f"`{_soc_src}`")
|
||||||
check("...and the call site says so in the source: the argument is the measured "
|
check("...and the call site says so in the source: the argument is the measured "
|
||||||
"battery attribute, not the standing command and not the resolved target",
|
"battery attribute, not the standing command and not the resolved target",
|
||||||
_batt_src == "self.batt")
|
_batt_src == "self.batt")
|
||||||
|
# ⚠️ SAFETY-24, AND ON THE SAME SINGLE CALL SITE. This grader takes the FIRST
|
||||||
|
# `.decide(` in main.py and reads a NAME rather than a value, so a second call
|
||||||
|
# site - or a decoy - would defeat it; this card deliberately adds neither, and
|
||||||
|
# extends the existing grader instead of writing a second one.
|
||||||
|
check("...and `soc` is handed over as the MEASURED reading, bare. Not "
|
||||||
|
"`self.soc or 100`, not a `float(..., 100)`, not the maintenance floor: "
|
||||||
|
"a full battery is exactly the value that disarms SAFETY-24's floor, and "
|
||||||
|
"NOTES.md 4.4b records this project shipping that exact defaulting once",
|
||||||
|
_soc_src == "self.soc")
|
||||||
|
check(f"...and main.py has exactly ONE `peakguard.decide(` call site (it has "
|
||||||
|
f"{len(_peak_calls)}), so the call graded above is unambiguously the "
|
||||||
|
f"shipped one. Other modules may call their own decide() - OPT-04's "
|
||||||
|
f"arbitrage.decide() does - and that must not silently move which call "
|
||||||
|
f"this grader reads",
|
||||||
|
len(_peak_calls) == 1)
|
||||||
|
# ⚠️ AND WHICH KEY THE FLOOR COMES FROM, GRADED ON THE SOURCE. A mutation that
|
||||||
|
# swapped `peak_soc_floor` for `maintenance_soc_floor` SURVIVED every
|
||||||
|
# behavioural check in this file, because the two defaults are close enough that
|
||||||
|
# no fixture separated them - which is exactly the coupling the card forbids and
|
||||||
|
# exactly the kind of survivor a value-based check cannot see. This grades the
|
||||||
|
# NAME, and part 9 below now also separates them behaviourally.
|
||||||
|
_floor_src = ast.unparse(next(k.value for k in _call.keywords
|
||||||
|
if k.arg == "soc_floor")).replace("'", '"')
|
||||||
|
print(f" main.py's decide(soc_floor=...) is `{_floor_src}`")
|
||||||
|
check("...and the floor comes from `peak_soc_floor`, defaulted from the ONE "
|
||||||
|
"mirror - not from `maintenance_soc_floor` (a drain target, not a spend "
|
||||||
|
"limit) and not from a literal, which would be CFG-03's fourth site",
|
||||||
|
'"peak_soc_floor"' in _floor_src
|
||||||
|
and "maintenance_soc_floor" not in _floor_src
|
||||||
|
and 'PEAK_OPTION_DEFAULTS["peak_soc_floor"]' in _floor_src)
|
||||||
|
|
||||||
# SAFETY-24 must be pointed at from the module that needs it, not only from a
|
# SAFETY-24 must be pointed at from the module that needs it, not only from a
|
||||||
# review thread - a ticket nobody can find from the code is a ticket nobody
|
# review thread - a ticket nobody can find from the code is a ticket nobody
|
||||||
@@ -1147,10 +1267,20 @@ check("peakguard.py names SAFETY-24, the missing SoC backstop on the forced "
|
|||||||
# CFG-03: no fourth defaults site.
|
# CFG-03: no fourth defaults site.
|
||||||
cfg = (HERE / "config.yaml").read_text(encoding="utf-8")
|
cfg = (HERE / "config.yaml").read_text(encoding="utf-8")
|
||||||
val = (HERE / "app" / "validate.py").read_text(encoding="utf-8")
|
val = (HERE / "app" / "validate.py").read_text(encoding="utf-8")
|
||||||
check("no new option was added: config.yaml names no peak-guard key, and "
|
# ⚠️ REWRITTEN BY SAFETY-24, BECAUSE IT IS NO LONGER TRUE AS WRITTEN. SAFETY-07
|
||||||
"§14's kW/W trap `capacity_peak_limit_kw` stays declined",
|
# added no option and this check said so. This card adds TWO and says which -
|
||||||
"peak_guard" not in cfg and "capacity_peak_limit_kw" not in cfg
|
# leaving the old sentence in place while the file it reads has grown two keys
|
||||||
and "peak_shave" not in cfg)
|
# would be a green line asserting the opposite of the diff. What is still
|
||||||
|
# refused is a THIRD: §14's kW/W trap stays declined, and no key beyond the two
|
||||||
|
# named ones exists.
|
||||||
|
_peak_keys = sorted(k for k in ("peak_guard", "peak_shave",
|
||||||
|
"capacity_peak_limit_kw")
|
||||||
|
if k in cfg)
|
||||||
|
check("SAFETY-24 adds exactly the two keys it names and no more: §14's kW/W "
|
||||||
|
"trap `capacity_peak_limit_kw` stays declined, and no speculative "
|
||||||
|
"`peak_guard`/`peak_shave` block appeared beside it",
|
||||||
|
_peak_keys == []
|
||||||
|
and sorted(PEAK_OPTION_DEFAULTS) == ["bms_soc_floor", "peak_soc_floor"])
|
||||||
# Graded on the parsed call syntax, not on the text: the module docstring names
|
# Graded on the parsed call syntax, not on the text: the module docstring names
|
||||||
# `peak_cap_w` while arguing that it does not read it, so a grep would be
|
# `peak_cap_w` while arguing that it does not read it, so a grep would be
|
||||||
# satisfied by deleting the explanation and would fail on writing one.
|
# satisfied by deleting the explanation and would fail on writing one.
|
||||||
@@ -1161,11 +1291,14 @@ _getters = [n for n in ast.walk(ast.parse(src))
|
|||||||
if isinstance(n, ast.Call) and isinstance(n.func, ast.Attribute)
|
if isinstance(n, ast.Call) and isinstance(n.func, ast.Attribute)
|
||||||
and n.func.attr == "get"]
|
and n.func.attr == "get"]
|
||||||
print(f" peakguard.py makes {len(_getters)} options-style `.get()` calls")
|
print(f" peakguard.py makes {len(_getters)} options-style `.get()` calls")
|
||||||
check("peakguard.py reads no option of its own: it makes no `.get()` call at "
|
check("peakguard.py still READS no option: it makes no `.get()` call at all "
|
||||||
"all and takes `cap_w` as an argument. CFG-03's three defaults sites are "
|
"and takes `cap_w`, `soc` and `soc_floor` as arguments. CFG-03's three "
|
||||||
"config.yaml's `options:`, config.yaml's `schema:` and main.py's literal "
|
"defaults sites are config.yaml's `options:`, config.yaml's `schema:` "
|
||||||
"fallbacks - this card adds no fourth",
|
"and main.py's fallbacks; PEAK_OPTION_DEFAULTS is a MIRROR of the first, "
|
||||||
not _getters and "cap_w" in _DECIDE_ARGS)
|
"TARIFF-02-style, not a fourth site - it is what main.py and validate.py "
|
||||||
|
"read INSTEAD of typing literals",
|
||||||
|
not _getters and "cap_w" in _DECIDE_ARGS and "soc" in _DECIDE_ARGS
|
||||||
|
and "soc_floor" in _DECIDE_ARGS)
|
||||||
# And the fallback in main.py must equal the shipped default, for the reason
|
# And the fallback in main.py must equal the shipped default, for the reason
|
||||||
# test_validate.py's CFG-03 block spells out at length: the two diverging is a
|
# test_validate.py's CFG-03 block spells out at length: the two diverging is a
|
||||||
# live defect in this repo for `maintenance_charge_w`, and it is not to be
|
# live defect in this repo for `maintenance_charge_w`, and it is not to be
|
||||||
@@ -1182,7 +1315,494 @@ check("...and every literal fallback for peak_cap_w in main.py equals the "
|
|||||||
|
|
||||||
# ==============================================================================
|
# ==============================================================================
|
||||||
print()
|
print()
|
||||||
print("8. mutation: what defeats this guard, and which check bites")
|
print("8. SAFETY-24: the energy floor under the forced discharge")
|
||||||
|
|
||||||
|
# ⚠️ THE STIMULUS FIRST, AND IT IS NOT DEGENERATE. Everything below is graded on
|
||||||
|
# a quarter that GENUINELY WANTS A FORCED DISCHARGE - `wanted > 0` - because the
|
||||||
|
# state of charge governs nothing on a cycle where the guard was never going to
|
||||||
|
# discharge. A check placed on a quiet quarter would pass with the gate removed,
|
||||||
|
# with the gate inverted, and with the gate reading the wrong sensor.
|
||||||
|
a_hungry = averager_at(CEIL + 900.0, 600.0)
|
||||||
|
p_hungry = PeakTracker.project(a_hungry, B + timedelta(seconds=600))
|
||||||
|
WANTED = BATT_NOW + excess_w(p_hungry, CEIL)
|
||||||
|
print(f" the stimulus: a quarter projecting {p_hungry.projected_w:.0f} W "
|
||||||
|
f"against a {CEIL:.0f} W ceiling with "
|
||||||
|
f"{QUARTER_S - p_hungry.elapsed_s:.0f} s left; a forced discharge of "
|
||||||
|
f"{WANTED:+.0f} W is what would hold it")
|
||||||
|
check("the stimulus really does want a forced discharge, so the SoC is a "
|
||||||
|
"quantity that decides something here", WANTED > 0.0)
|
||||||
|
|
||||||
|
# --- the predicate, which is the ONE place the question is answered ----------
|
||||||
|
PERMITS = discharge_permitted(SOC_OK, SOC_FLOOR)
|
||||||
|
AT = discharge_permitted(SOC_FLOOR, SOC_FLOOR)
|
||||||
|
UNDER = discharge_permitted(SOC_FLOOR - 1.0, SOC_FLOOR)
|
||||||
|
UNREAD = discharge_permitted(None, SOC_FLOOR)
|
||||||
|
NOFLOOR = discharge_permitted(SOC_OK, None)
|
||||||
|
print(f" discharge_permitted: {SOC_OK:.0f} % -> {PERMITS!r}")
|
||||||
|
print(f" {SOC_FLOOR:.0f} % (exactly at) -> {AT!r}")
|
||||||
|
print(f" None (unreadable) -> {UNREAD!r}")
|
||||||
|
check("a pack above the floor may be discharged", PERMITS is None)
|
||||||
|
check("...a pack AT the floor may not - `<=`, not `<`. Permitting one more "
|
||||||
|
"cycle at the floor would make the floor mean 'one cycle below the "
|
||||||
|
"floor', which is the whole quantity this option names",
|
||||||
|
AT == FLOOR_AT_SOC_FLOOR and UNDER == FLOOR_AT_SOC_FLOOR)
|
||||||
|
check("...an UNREADABLE SoC is refused, and refused with its OWN reason. A "
|
||||||
|
"failed read is not an observation, and a full battery is exactly the "
|
||||||
|
"value that would disarm this floor",
|
||||||
|
UNREAD == FLOOR_SOC_UNREADABLE and UNREAD != AT)
|
||||||
|
check("...and no configured floor is not permission either", NOFLOOR is not None)
|
||||||
|
# THE DISARMING ALTERNATIVE, COMPUTED RATHER THAN DESCRIBED. `float(soc or 100)`
|
||||||
|
# is the shape NOTES.md 4.4b records the stage-5 loop actually shipping.
|
||||||
|
check("...and the defaulting form that was ACTUALLY shipped once in this "
|
||||||
|
"project - reading a missing SoC as a full battery - would have permitted "
|
||||||
|
"it, so this is a live direction and not a hypothetical",
|
||||||
|
discharge_permitted(float(None or 100), SOC_FLOOR) is None)
|
||||||
|
|
||||||
|
# --- the decision -----------------------------------------------------------
|
||||||
|
d_ok = decide(p_hungry, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK,
|
||||||
|
soc_floor=SOC_FLOOR)
|
||||||
|
d_lim = decide(p_hungry, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
||||||
|
soc=SOC_FLOOR, soc_floor=SOC_FLOOR)
|
||||||
|
d_unread = decide(p_hungry, batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=None,
|
||||||
|
soc_floor=SOC_FLOOR)
|
||||||
|
print(f" with battery: {d_ok.explain()}")
|
||||||
|
print(f" at the floor: {d_lim.explain()}")
|
||||||
|
check("with battery to spare the guard sizes the forced discharge exactly as "
|
||||||
|
"SAFETY-07 always did - this card changes nothing above the floor",
|
||||||
|
d_ok.engaged and not d_ok.floor_limited and near(d_ok.floor_w, WANTED, 1e-6))
|
||||||
|
check("at the floor it STOPS, and the floor it files is 0 W - not the discharge "
|
||||||
|
"it wanted, and not a negative number",
|
||||||
|
d_lim.engaged and d_lim.floor_limited and near(d_lim.floor_w, 0.0))
|
||||||
|
check("...and it REPORTS being floor-limited rather than silently under-"
|
||||||
|
"shaving: the decision carries the flag, the reason it bound, the SoC it "
|
||||||
|
"read and the floor it read",
|
||||||
|
d_lim.floor_limited and d_lim.soc_floor_reason == FLOOR_AT_SOC_FLOOR
|
||||||
|
and near(d_lim.soc, SOC_FLOOR) and near(d_lim.soc_floor, SOC_FLOOR))
|
||||||
|
check("...and it still says what it WOULD have taken, so the under-shave is a "
|
||||||
|
"number rather than a silence",
|
||||||
|
near(d_lim.wanted_w, WANTED, 1e-6) and d_lim.wanted_w > d_lim.floor_w)
|
||||||
|
check("...and its one-line explanation tells the operator the consequence in "
|
||||||
|
"the words that matter - the quarter is going over the ceiling",
|
||||||
|
"FLOOR-LIMITED" in d_lim.explain()
|
||||||
|
and "WILL GO OVER THE CEILING" in d_lim.explain()
|
||||||
|
and f"{CEIL:.0f} W" in d_lim.explain())
|
||||||
|
check("an unreadable SoC lands in the same branch, with the OTHER reason - so "
|
||||||
|
"an operator reading one line can tell a flat battery from a dead sensor",
|
||||||
|
d_unread.floor_limited and near(d_unread.floor_w, 0.0)
|
||||||
|
and d_unread.soc_floor_reason == FLOOR_SOC_UNREADABLE
|
||||||
|
and d_unread.soc is None)
|
||||||
|
check("floor-limited and saturated are MUTUALLY EXCLUSIVE, by construction: the "
|
||||||
|
"branch returns before the achievable_w clamp that sets `saturated`, so "
|
||||||
|
"the two notifications can never both fire on one cycle",
|
||||||
|
not d_lim.saturated and not d_unread.saturated)
|
||||||
|
|
||||||
|
# --- and NOT graded where it is degenerate ----------------------------------
|
||||||
|
# The same empty pack on a quarter that is UNDER the ceiling. A gate placed one
|
||||||
|
# line earlier would report FLOOR-LIMITED here - on a quiet afternoon, over a
|
||||||
|
# guard that was never going to discharge - and an operator who is told the peak
|
||||||
|
# will be exceeded on a quarter that is nowhere near it stops reading the
|
||||||
|
# notification that matters.
|
||||||
|
d_quiet = decide(PeakTracker.project(averager_at(500.0, 450.0),
|
||||||
|
B + timedelta(seconds=450)),
|
||||||
|
batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
||||||
|
soc=SOC_FLOOR - 5.0, soc_floor=SOC_FLOOR)
|
||||||
|
print(f" an EMPTY pack on a quiet quarter: {d_quiet.explain()}")
|
||||||
|
check("an empty pack on a quarter that does not need shaving is IDLE, not "
|
||||||
|
"floor-limited. The SoC is only graded where a forced discharge is "
|
||||||
|
"actually being asked for - grading it earlier would raise the alarm on "
|
||||||
|
"every quiet cycle of the day",
|
||||||
|
not d_quiet.engaged and not d_quiet.floor_limited
|
||||||
|
and d_quiet.floor_w is None)
|
||||||
|
# And the BLIND branch is untouched: it never forces a discharge, so there is
|
||||||
|
# nothing for an energy floor to bound there.
|
||||||
|
d_blind_low = decide(p_frozen, batt_w=-RAILED, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
||||||
|
soc=SOC_FLOOR - 5.0, soc_floor=SOC_FLOOR, frozen=True)
|
||||||
|
check("...and an empty pack does not disturb the BLIND branch either: SAFETY-"
|
||||||
|
"18's cut is still a 0 W floor, still blocks charging, and is still not "
|
||||||
|
"reported as an energy problem",
|
||||||
|
d_blind_low.engaged and near(d_blind_low.floor_w, 0.0)
|
||||||
|
and d_blind_low.blind == BLIND_FROZEN and not d_blind_low.floor_limited)
|
||||||
|
|
||||||
|
# --- the claim, through the real arbiter ------------------------------------
|
||||||
|
lc = peakguard.claim(d_lim)
|
||||||
|
print(f" floor-limited claim: {lc.source} {lc.kind} lo={lc.lo:.0f} "
|
||||||
|
f"hi={lc.hi} reason={lc.reason!r}")
|
||||||
|
r_charge = resolve(SAFE + [Claim.set("loop", P_LOOP, -1500.0, "grid"), lc])
|
||||||
|
r_disch = resolve(SAFE + [Claim.set("loop", P_LOOP, 1800.0, "grid"), lc])
|
||||||
|
r_stop = resolve(SAFE + [Claim.set("safety", P_SAFETY, 0.0, "stopped"), lc])
|
||||||
|
print(f" loop wants to charge 1500 W: {r_charge.explain()}")
|
||||||
|
print(f" loop wants to discharge 1800 W: {r_disch.explain()}")
|
||||||
|
check("a floor-limited guard STILL blocks charging - 0 W is one-directional, "
|
||||||
|
"it can only ever lower delivered offtake, and adding import in the "
|
||||||
|
"quarter that sets the bill is the one thing it must not permit",
|
||||||
|
near(r_charge.target_w, 0.0) and not r_charge.contradiction)
|
||||||
|
check("...and it does NOT pull the loop off a discharge it is already doing. A "
|
||||||
|
"`lo` limit is structurally incapable of capping discharge, which is why "
|
||||||
|
"the action here is 0 W and never a negative floor",
|
||||||
|
near(r_disch.target_w, 1800.0, 1e-9))
|
||||||
|
check("...and every P_SAFETY stop still outranks it. This is an ENERGY bound, "
|
||||||
|
"not a trip: 11.2's table is unchanged by this card",
|
||||||
|
near(r_stop.target_w, 0.0) and not r_stop.contradiction)
|
||||||
|
check("...and its arbiter reason names the SoC floor rather than reusing "
|
||||||
|
"'blind' or 'quarter peak', so the one line an operator reads tells the "
|
||||||
|
"three 0 W states apart", lc.reason == "SoC floor"
|
||||||
|
and peakguard.claim(d_ok).reason == "quarter peak")
|
||||||
|
|
||||||
|
# --- THE PROPERTY THE WHOLE SHAPE RESTS ON: no negative floor, ever ----------
|
||||||
|
# A `lo` limit is incapable of capping discharge or export only while it is
|
||||||
|
# non-negative. If this card could produce `lo < 0` it would have broken 9.1 as
|
||||||
|
# a property of the object, and the guard would be capping the very thing it is
|
||||||
|
# forbidden to cap. Swept rather than argued.
|
||||||
|
SWEEP_NEG = SWEEP_BOTH = SWEEP_N = 0
|
||||||
|
SWEEP_HI = True
|
||||||
|
for load in (0.0, CEIL - 500.0, CEIL, CEIL + 300.0, CEIL + 3000.0,
|
||||||
|
LIVE_MAX_W * 3):
|
||||||
|
for elapsed in (30.0, 450.0, 870.0):
|
||||||
|
_pr = PeakTracker.project(averager_at(load, elapsed),
|
||||||
|
B + timedelta(seconds=elapsed))
|
||||||
|
for bw in (-2000.0, 0.0, 400.0, 4000.0):
|
||||||
|
for sc in (None, 0.0, BMS_FLOOR, SOC_FLOOR, SOC_FLOOR + 0.5, 100.0):
|
||||||
|
for fl in (SOC_FLOOR, BMS_FLOOR + 1.0, 55.0):
|
||||||
|
_d = decide(_pr, batt_w=bw, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W,
|
||||||
|
max_hold_s=MAX_HOLD_S, soc=sc, soc_floor=fl)
|
||||||
|
SWEEP_N += 1
|
||||||
|
if _d.floor_w is not None and _d.floor_w < 0.0:
|
||||||
|
SWEEP_NEG += 1
|
||||||
|
if _d.floor_limited and _d.saturated:
|
||||||
|
SWEEP_BOTH += 1
|
||||||
|
_c = peakguard.claim(_d)
|
||||||
|
if _c is not None and not (isinf(_c.hi) and _c.hi > 0):
|
||||||
|
SWEEP_HI = False
|
||||||
|
print(f" swept {SWEEP_N} (load x elapsed x battery x SoC x floor) "
|
||||||
|
f"combinations, SoC included: {SWEEP_NEG} negative floors, "
|
||||||
|
f"{SWEEP_BOTH} decisions both floor-limited and saturated")
|
||||||
|
check(f"NOT ONE of the {SWEEP_N} combinations produces a negative floor. That "
|
||||||
|
f"is 9.1's 'discharge and export are never capped by the peak guard' as a "
|
||||||
|
f"property of the object, and SAFETY-24 preserves it - the only two "
|
||||||
|
f"values floor_w takes are 0.0 and a positive min(wanted, achievable)",
|
||||||
|
SWEEP_NEG == 0 and SWEEP_N > 600)
|
||||||
|
check("...and `hi` stays +inf on every claim any of them files",
|
||||||
|
SWEEP_HI)
|
||||||
|
check("...and no combination is both floor-limited and saturated, so the two "
|
||||||
|
"notifications are exclusive on measured inputs and not merely by reading "
|
||||||
|
"the code", SWEEP_BOTH == 0)
|
||||||
|
|
||||||
|
# --- TEST-14: a required field must not quietly gain a default --------------
|
||||||
|
# ⚠️ PORTED AS A SCAN, NOT HAND-WRITTEN PER FIELD. TEST-14 is open because an
|
||||||
|
# outcome type's required field gained a default in three separate files and no
|
||||||
|
# check noticed. The pinned sets below go red if ANY field or argument moves
|
||||||
|
# between required and defaulted - including a future one nobody has thought of
|
||||||
|
# - which is the whole difference between a scan and a case.
|
||||||
|
_sig = inspect.signature(decide)
|
||||||
|
_required_kw = {n for n, prm in _sig.parameters.items()
|
||||||
|
if prm.kind is prm.KEYWORD_ONLY and prm.default is prm.empty}
|
||||||
|
print(f" decide() required keyword-only arguments: {sorted(_required_kw)}")
|
||||||
|
check("`soc` and `soc_floor` are REQUIRED keyword-only arguments of decide() "
|
||||||
|
"with no default. A default on either is TEST-14's exact shape and would "
|
||||||
|
"be the quiet fallback this card exists to remove - and a default on "
|
||||||
|
"`soc_floor` would additionally be CFG-03's fourth defaults site",
|
||||||
|
_required_kw == {"batt_w", "cap_w", "reading", "achievable_w", "soc",
|
||||||
|
"soc_floor"})
|
||||||
|
_req_fields = tuple(f.name for f in dataclasses.fields(PeakDecision)
|
||||||
|
if f.default is dataclasses.MISSING
|
||||||
|
and f.default_factory is dataclasses.MISSING)
|
||||||
|
print(f" PeakDecision fields with no default: {list(_req_fields)}")
|
||||||
|
check("...and PeakDecision's required fields are unchanged by this card: the "
|
||||||
|
"four SAFETY-07 pinned, and the SAFETY-24 additions are genuinely "
|
||||||
|
"optional reporting rather than required fields handed a default",
|
||||||
|
_req_fields == ("engaged", "floor_w", "ceiling_w", "ceiling_from"))
|
||||||
|
|
||||||
|
|
||||||
|
# ==============================================================================
|
||||||
|
print()
|
||||||
|
print("9. the exhausting replay (AC 4), and the startup refusal")
|
||||||
|
|
||||||
|
# ⚠️ THE PACK IS SIZED FROM THE MEASUREMENT, NOT PICKED. `WH_07` is what the
|
||||||
|
# guard actually asks for on 2026-08-20 - re-derived from the committed capture
|
||||||
|
# on every run, never quoted - and the modelled pack is then chosen so the energy
|
||||||
|
# between the start and the EMS floor is ONE THIRD of it. That makes "a quarter
|
||||||
|
# that would exhaust the pack" true by construction of the measurement rather
|
||||||
|
# than by a number typed into this file: the day wants three times what the pack
|
||||||
|
# has to give above the floor, so it must run out, and without an EMS floor it
|
||||||
|
# must run through the BMS one too.
|
||||||
|
BAD = [pth for pth in REPLAY if "2026-08-20" in pth.name][0]
|
||||||
|
WH_BAD = replay(BAD, guarded=True)["wh"]
|
||||||
|
START_SOC = SOC_FLOOR + (SOC_FLOOR - BMS_FLOOR)
|
||||||
|
USABLE_WH = 100.0 * (WH_BAD / 3.0) / (START_SOC - SOC_FLOOR)
|
||||||
|
PACK = (USABLE_WH, START_SOC, BMS_FLOOR)
|
||||||
|
# How far past the floor one cycle at the rail can carry the pack before the
|
||||||
|
# next decision sees it. DERIVED from the cycle and the modelled pack, because a
|
||||||
|
# tolerance typed as a constant is a tolerance that stops meaning anything.
|
||||||
|
OVERSHOOT_PP = 100.0 * (LIVE_MAX_W * CYCLE_S / 3600.0) / USABLE_WH
|
||||||
|
print(f" the guard's measured appetite on {BAD.name}: {WH_BAD:.0f} Wh")
|
||||||
|
print(f" modelled pack: {USABLE_WH:.0f} Wh usable, starting at "
|
||||||
|
f"{START_SOC:.0f} %, BMS cut at {BMS_FLOOR:.0f} %, EMS floor at "
|
||||||
|
f"{SOC_FLOOR:.0f} %")
|
||||||
|
print(f" -> {(START_SOC - SOC_FLOOR) / 100.0 * USABLE_WH:.0f} Wh above the "
|
||||||
|
f"EMS floor, {(START_SOC - BMS_FLOOR) / 100.0 * USABLE_WH:.0f} Wh above "
|
||||||
|
f"the BMS one - against {WH_BAD:.0f} Wh of appetite; one cycle at the "
|
||||||
|
f"rail is {OVERSHOOT_PP:.2f} pp of this pack")
|
||||||
|
check("the fixture is a pack this day genuinely exhausts, and that is derived "
|
||||||
|
"from the day's own measured appetite rather than asserted: the energy "
|
||||||
|
"above the BMS cut-out is less than the guard wants",
|
||||||
|
(START_SOC - BMS_FLOOR) / 100.0 * USABLE_WH < WH_BAD)
|
||||||
|
|
||||||
|
# TWO WORLDS, SAME PACK, SAME CAPTURE.
|
||||||
|
# BEFORE: the EMS floor set to the BMS cut-out - i.e. the BMS is the sole
|
||||||
|
# energy backstop, which is precisely what SAFETY-07 shipped.
|
||||||
|
# AFTER: the EMS floor as config.yaml ships it.
|
||||||
|
BEFORE = replay(BAD, guarded=True, pack=PACK, soc_floor=BMS_FLOOR)
|
||||||
|
AFTER = replay(BAD, guarded=True, pack=PACK, soc_floor=SOC_FLOOR)
|
||||||
|
print(f" BEFORE (BMS is the only backstop): ends at {BEFORE['end_soc']:.1f} %"
|
||||||
|
f", low-water {BEFORE['min_soc']:.1f} %, {BEFORE['wh']:.0f} Wh out, "
|
||||||
|
f"{BEFORE['at_bms']} guard cycles spent AT the BMS limit, "
|
||||||
|
f"{BEFORE['limited']} floor-limited")
|
||||||
|
print(f" AFTER (peak_soc_floor {SOC_FLOOR:.0f} %): ends at "
|
||||||
|
f"{AFTER['end_soc']:.1f} %, low-water {AFTER['min_soc']:.1f} %, "
|
||||||
|
f"{AFTER['wh']:.0f} Wh out, {AFTER['at_bms']} cycles at the BMS limit, "
|
||||||
|
f"{AFTER['limited']} floor-limited")
|
||||||
|
check("BEFORE: the day really does take the pack to the BMS cut-out and hold it "
|
||||||
|
"there. That is the finding this card answers - not a pack destroyed, a "
|
||||||
|
"pack repeatedly parked at its own protection with no EMS-side record of "
|
||||||
|
"why", BEFORE["min_soc"] <= BMS_FLOOR + 1e-9 and BEFORE["at_bms"] > 0)
|
||||||
|
check("AFTER: the forced discharge STOPS AT THE CONFIGURED FLOOR - to within "
|
||||||
|
"the one cycle of overshoot the 15 s tick allows, derived above and not "
|
||||||
|
"typed - and the pack never reaches the BMS limit at all. That is AC 1, "
|
||||||
|
"replayed rather than reasoned about",
|
||||||
|
AFTER["min_soc"] >= SOC_FLOOR - OVERSHOOT_PP and AFTER["at_bms"] == 0
|
||||||
|
and AFTER["min_soc"] > BMS_FLOOR + 1.0)
|
||||||
|
check("...and it does not merely stop, it SAYS SO: floor-limited cycles are "
|
||||||
|
"counted off the decisions themselves, so the under-shave is reported "
|
||||||
|
"rather than silent", AFTER["limited"] > 0)
|
||||||
|
# ⚠️ WHAT "BEFORE" IS AND IS NOT. It is the shipped code with the EMS floor set
|
||||||
|
# equal to the BMS cut-out, which reproduces the pre-card ENERGY trajectory
|
||||||
|
# exactly - the pack drains to the BMS and the BMS is the only thing that stops
|
||||||
|
# it. What it does not reproduce is the silence: pre-card there was no gate to
|
||||||
|
# report at all, whereas this run reports one at the BMS limit, by which point
|
||||||
|
# the pack is already there. The trajectory is the thing being compared.
|
||||||
|
check("...and the two worlds differ in the trajectory, not merely in a flag: "
|
||||||
|
"before, every floor-limited cycle happens with the pack ALREADY at the "
|
||||||
|
"BMS limit; after, none of them do",
|
||||||
|
BEFORE["at_bms"] > 0 and AFTER["at_bms"] == 0)
|
||||||
|
# THE DERIVED VERDICT: the energy the card withholds is exactly the energy
|
||||||
|
# between the two floors. Not "less", not "a bit" - the difference in Wh equals
|
||||||
|
# the difference in percentage points times the pack, to within one cycle.
|
||||||
|
GAP_WH = (SOC_FLOOR - BMS_FLOOR) / 100.0 * USABLE_WH
|
||||||
|
TOL = 2.0 * LIVE_MAX_W * CYCLE_S / 3600.0 # one cycle of overshoot per run
|
||||||
|
print(f" energy withheld: {BEFORE['wh'] - AFTER['wh']:.1f} Wh, against "
|
||||||
|
f"{GAP_WH:.1f} Wh between the two floors (tolerance {TOL:.1f} Wh = one "
|
||||||
|
f"cycle of overshoot at the rail in each of the two runs)")
|
||||||
|
check("the energy this card withholds IS the energy between the two floors, to "
|
||||||
|
"within one cycle at the rail - so the floor is doing the arithmetic it "
|
||||||
|
"claims and is not merely correlated with doing less",
|
||||||
|
abs((BEFORE["wh"] - AFTER["wh"]) - GAP_WH) <= TOL)
|
||||||
|
check("...and no cycle in either world files a negative floor, on real "
|
||||||
|
"captured data and not only on the synthetic sweep",
|
||||||
|
BEFORE["neg_floor"] == 0 and AFTER["neg_floor"] == 0)
|
||||||
|
# THE HONEST HALF. Stopping costs money, and the check says how much rather than
|
||||||
|
# looking away from it.
|
||||||
|
_ub = max(BEFORE["blocks"].values())
|
||||||
|
_ab = max(AFTER["blocks"].values())
|
||||||
|
print(f" the price of the floor: worst quarter {_ub:.0f} W before, "
|
||||||
|
f"{_ab:.0f} W after - a floor-limited guard shaves LESS, on purpose, and "
|
||||||
|
f"the operator is told so")
|
||||||
|
check("stopping at the floor costs peak shaving, and this file says so out "
|
||||||
|
"loud rather than reporting only the SoC it saved: the worst quarter is "
|
||||||
|
"no better with the floor in place", _ab >= _ub - 1e-6)
|
||||||
|
|
||||||
|
# --- the wiring: one real cycle on an empty pack -----------------------------
|
||||||
|
# ⚠️ `maintenance_soc_floor` IS SET, AND SET TO A VALUE THAT WOULD FLIP THE
|
||||||
|
# ANSWER. The pack sits one point under `peak_soc_floor` and well ABOVE the
|
||||||
|
# maintenance floor, so a controller that read the maintenance key would come
|
||||||
|
# out NOT limited here. Without this the two keys are indistinguishable on every
|
||||||
|
# fixture in this file - a mutation swapping them survived until it was added.
|
||||||
|
MAINT_LOW = 5
|
||||||
|
c24, hass24, NET24, _ = wired_over_limit(
|
||||||
|
TMP / "soc24.db", LIVE_MAX_W * 0.3, soc=SOC_FLOOR - 1.0,
|
||||||
|
opts={"maintenance_soc_floor": MAINT_LOW})
|
||||||
|
check(f"the fixture separates the two floors: the pack at {SOC_FLOOR - 1:.0f} % "
|
||||||
|
f"is under peak_soc_floor {SOC_FLOOR:.0f} % and over "
|
||||||
|
f"maintenance_soc_floor {MAINT_LOW} %, so reading the wrong key gives the "
|
||||||
|
f"wrong answer here", MAINT_LOW < SOC_FLOOR - 1.0 < SOC_FLOOR)
|
||||||
|
print(f" a real cycle over a {NET24:.0f} W quarter with the pack at "
|
||||||
|
f"{SOC_FLOOR - 1.0:.0f} %: {c24.peak_guard.explain()}")
|
||||||
|
check("the REAL Controller reaches the floor-limited branch, so main.py hands "
|
||||||
|
"decide() a state of charge at all", c24.peak_guard.floor_limited)
|
||||||
|
check("...and the number written to the inverter is not a forced discharge - "
|
||||||
|
"the pack is not spent for money below the floor",
|
||||||
|
hass24.writes and hass24.writes[-1] >= -1e-6
|
||||||
|
and hass24.writes[-1] <= c24.peak_guard.wanted_w)
|
||||||
|
check("...and the operator is TOLD THE PEAK WILL BE EXCEEDED, exactly once, "
|
||||||
|
"with its own notification id - AC 2, and the reason failing to shave "
|
||||||
|
"must not be silent",
|
||||||
|
hass24.notifications.count("goodwe_peak_soc_floor") == 1
|
||||||
|
and "goodwe_peak_saturated" not in hass24.notifications)
|
||||||
|
asyncio.get_event_loop_policy().new_event_loop().run_until_complete(c24.cycle())
|
||||||
|
check("...once per episode, not once per cycle - a quarter of an hour of "
|
||||||
|
"identical cards is how an operator learns to dismiss the one that "
|
||||||
|
"mattered", hass24.notifications.count("goodwe_peak_soc_floor") == 1)
|
||||||
|
rows24 = [r for r in c24.checks() if "peak guard" in r["text"].lower()]
|
||||||
|
print(" status row: " + (rows24[0]["text"] if rows24 else "(none)"))
|
||||||
|
check("the status page carries exactly one peak-guard row and it is NOT ok - "
|
||||||
|
"the money is going to be spent and a human is the only actuator left",
|
||||||
|
len(rows24) == 1 and not rows24[0]["ok"]
|
||||||
|
and "FLOOR-LIMITED" in rows24[0]["text"])
|
||||||
|
check("...and it reaches the action log too", any("FLOOR-LIMITED" in e
|
||||||
|
for e in c24.events))
|
||||||
|
# A missing SoC sensor, through the same real cycle. `inputs_ok` stops the loop
|
||||||
|
# at 0 W in that state, so the guard's own answer is what is graded here.
|
||||||
|
d_nosoc = decide(p_hungry, batt_w=0.0, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
||||||
|
soc=None, soc_floor=SOC_FLOOR)
|
||||||
|
check("decide() handed soc=None answers floor-limited rather than a full "
|
||||||
|
"battery - the whole 'a failed read is not an observation' rule, on the "
|
||||||
|
"one input where the disarming value is the plausible one",
|
||||||
|
d_nosoc.floor_limited and not d_nosoc.saturated)
|
||||||
|
# ⚠️ REVIEW-FOUND, AND THE CLAIM ABOVE USED TO BE WIDER THAN ITS CHECK. It read
|
||||||
|
# "a CONTROLLER whose SoC entity does not answer hands decide() None" while
|
||||||
|
# calling decide() directly and driving no Controller - so a reviewer could
|
||||||
|
# insert `self.soc = 100.0 if self.soc is None else self.soc` immediately above
|
||||||
|
# main.py's decide() call, which is the exact `float(soc or 100)` defaulting
|
||||||
|
# discharge_permitted()'s own docstring forbids, and every check here stayed
|
||||||
|
# green. The wiring property is STRONGER than the one that was claimed, and this
|
||||||
|
# is it: a Controller with no SoC never reaches the guard at all, because
|
||||||
|
# `inputs_ok` is False and cycle() returns at the safety stop first. Graded on
|
||||||
|
# the SERVICE CALL - decide() is spied - rather than on its arguments, so a
|
||||||
|
# defaulted value cannot satisfy it.
|
||||||
|
_nosoc_ctl, _nosoc_hass = built(TMP / "nosoc.db")
|
||||||
|
_nosoc_ctl.auto, _nosoc_ctl.soc, _nosoc_ctl.batt = True, None, 0.0
|
||||||
|
_nosoc_ctl.dev_min, _nosoc_ctl.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||||
|
_nosoc_now = datetime.now(timezone.utc)
|
||||||
|
_nosoc_blk = datetime.fromtimestamp(
|
||||||
|
int(_nosoc_now.timestamp() // QUARTER_S) * QUARTER_S, timezone.utc)
|
||||||
|
for _i in range(0, int((_nosoc_now - _nosoc_blk).total_seconds()) + 1, 5):
|
||||||
|
_nosoc_ctl.p1.submit(sample(_nosoc_blk + timedelta(seconds=_i), CAP_W * 2))
|
||||||
|
_nosoc_ctl.grid = CAP_W * 2
|
||||||
|
_nosoc_seen = []
|
||||||
|
_nosoc_real = peakguard.decide
|
||||||
|
try:
|
||||||
|
peakguard.decide = lambda *a, **k: (_nosoc_seen.append(k.get("soc")),
|
||||||
|
_nosoc_real(*a, **k))[1]
|
||||||
|
asyncio.get_event_loop_policy().new_event_loop().run_until_complete(
|
||||||
|
_nosoc_ctl.cycle())
|
||||||
|
finally:
|
||||||
|
peakguard.decide = _nosoc_real
|
||||||
|
print(f" a Controller with no SoC: inputs_ok={_nosoc_ctl.inputs_ok}, "
|
||||||
|
f"decide() called {len(_nosoc_seen)} time(s), target "
|
||||||
|
f"{_nosoc_ctl.target:+.0f} W")
|
||||||
|
check("and a Controller whose SoC entity does not answer never reaches the "
|
||||||
|
"guard AT ALL - `inputs_ok` is False, cycle() stops at the safety claim, "
|
||||||
|
"and decide() is not called. A defaulting line above the call site "
|
||||||
|
"therefore cannot disarm this floor, which is a stronger guarantee than "
|
||||||
|
"handing decide() a None would be",
|
||||||
|
not _nosoc_ctl.inputs_ok and not _nosoc_seen
|
||||||
|
and abs(_nosoc_ctl.target) < 1e-9 and _nosoc_ctl.peak_guard is None)
|
||||||
|
|
||||||
|
# --- the startup refusal, in CFG-01 / MAINT-04's manner ----------------------
|
||||||
|
def opts24(**kw):
|
||||||
|
"""Otherwise-startable options, so the ONLY thing under test is rule 8."""
|
||||||
|
base = {"setpoint_entity": "number.sp", "meter_source": "off",
|
||||||
|
"meter_entity": "sensor.grid", "max_w": 2000,
|
||||||
|
"meter_phases": 1, "meter_max_age_s": 30, "sign_disagree_w": 300,
|
||||||
|
"maintenance_charge_w": 2000,
|
||||||
|
"peak_soc_floor": PEAK_OPTION_DEFAULTS["peak_soc_floor"],
|
||||||
|
"bms_soc_floor": PEAK_OPTION_DEFAULTS["bms_soc_floor"]}
|
||||||
|
base.update(kw)
|
||||||
|
return base
|
||||||
|
|
||||||
|
|
||||||
|
BASE_OK = validate_startup_config(opts24())
|
||||||
|
check("the SHIPPED pair starts - a validator that refuses config.yaml's own "
|
||||||
|
"defaults is a validator nobody keeps", BASE_OK == [])
|
||||||
|
|
||||||
|
|
||||||
|
def rule8(problems):
|
||||||
|
return [x for x in problems if "bms_soc_floor" in x]
|
||||||
|
|
||||||
|
|
||||||
|
below = rule8(validate_startup_config(opts24(peak_soc_floor=BMS_FLOOR - 5)))
|
||||||
|
equal = rule8(validate_startup_config(opts24(peak_soc_floor=BMS_FLOOR)))
|
||||||
|
above = rule8(validate_startup_config(opts24(peak_soc_floor=BMS_FLOOR + 1)))
|
||||||
|
junk = validate_startup_config(opts24(peak_soc_floor="soon"))
|
||||||
|
print(f" refusal at {BMS_FLOOR - 5:.0f} %: {below[0][:96] if below else '(none)'}...")
|
||||||
|
check("a floor BELOW the pack's own cut-out is refused at startup, in CFG-01 / "
|
||||||
|
"MAINT-04's manner - the operator states a bound, the BMS enforces a "
|
||||||
|
"different one, and nothing would say which won", len(below) == 1)
|
||||||
|
check("...and so is a floor EXACTLY AT it, which is the interesting case: equal "
|
||||||
|
"buys zero margin, so it can never be the thing that stops the discharge "
|
||||||
|
"and the status page would report a backstop that cannot bind. Rule 6 "
|
||||||
|
"permits equality because equality there leaves one working point; here "
|
||||||
|
"it leaves none", len(equal) == 1)
|
||||||
|
check("...while one point above is accepted, so this refuses the disarmed case "
|
||||||
|
"only and not 'close to the limit'", above == [])
|
||||||
|
check("...and the refusal NAMES BOTH NUMBERS and the shipped default, so the "
|
||||||
|
"operator can act on it without reading the source",
|
||||||
|
f"{BMS_FLOOR:.0f} %" in below[0]
|
||||||
|
and f"{BMS_FLOOR - 5:.0f} %" in below[0]
|
||||||
|
and f"{PEAK_OPTION_DEFAULTS['peak_soc_floor']:.0f} %" in below[0])
|
||||||
|
check("...and a non-numeric floor is refused rather than defaulted, for the "
|
||||||
|
"reason every read in this file is: a value that cannot be parsed is not "
|
||||||
|
"an observation of anything",
|
||||||
|
any("must both be numbers" in x for x in junk))
|
||||||
|
# ⚠️ AND IT IS NOT SCOPED TO ANYTHING. Rule 6's comment gives the argument: a
|
||||||
|
# contradictory pair is contradictory whether or not the feature is switched on,
|
||||||
|
# and scoping it leaves the trap armed for the one operator action that cannot
|
||||||
|
# be expected to change what a floor means.
|
||||||
|
check("...and the rule is not scoped to meter_source or to any enable flag - "
|
||||||
|
"the pair is wrong on a P1 install too, and 'turn P1 on' is not an action "
|
||||||
|
"that should change what a SoC floor means",
|
||||||
|
len(rule8(validate_startup_config(opts24(
|
||||||
|
peak_soc_floor=BMS_FLOOR - 5, meter_source="ha_signed",
|
||||||
|
p1_net_entity="sensor.net")))) == 1)
|
||||||
|
|
||||||
|
# --- CFG-03: the mirror, pinned to config.yaml -------------------------------
|
||||||
|
# TARIFF-02's pattern exactly - and pinned by READING the shipped file, not by
|
||||||
|
# transcribing it, which is the only version of this check that can catch drift.
|
||||||
|
_found24 = {k: read_option(k) for k in PEAK_OPTION_DEFAULTS}
|
||||||
|
print(f" config.yaml ships {_found24}, peakguard mirrors "
|
||||||
|
f"{dict(PEAK_OPTION_DEFAULTS)}")
|
||||||
|
check("every SAFETY-24 option is shipped in config.yaml's options: block",
|
||||||
|
all(v is not None for v in _found24.values()))
|
||||||
|
check("...and each shipped default equals PEAK_OPTION_DEFAULTS, the ONE in-code "
|
||||||
|
"mirror - TARIFF-02's move, so this card adds no fourth defaults site",
|
||||||
|
all(float(_found24[k]) == float(v)
|
||||||
|
for k, v in PEAK_OPTION_DEFAULTS.items()))
|
||||||
|
_schema24 = [k for k in PEAK_OPTION_DEFAULTS if read_schema_max(k) is not None]
|
||||||
|
check("...and both are in the schema: block too, or the Supervisor drops the "
|
||||||
|
"option and the add-on silently runs on the mirror instead of the "
|
||||||
|
"operator's value", sorted(_schema24) == sorted(PEAK_OPTION_DEFAULTS))
|
||||||
|
_val_src = (HERE / "app" / "validate.py").read_text(encoding="utf-8")
|
||||||
|
check("...and validate.py takes its fallbacks from that same mirror rather than "
|
||||||
|
"typing literals - which is the divergence its own rule 6 documents "
|
||||||
|
"(maintenance_charge_w 2000 there, 2500 in main.py), refused a second "
|
||||||
|
"outing here",
|
||||||
|
"PEAK_OPTION_DEFAULTS" in _val_src
|
||||||
|
and not re.search(r'"peak_soc_floor"\s*,\s*[0-9]', _val_src)
|
||||||
|
and not re.search(r'"peak_soc_floor"\s*,\s*[0-9]', _mainsrc))
|
||||||
|
check("...and 20 % is not a number typed into config.yaml on a hunch: it is 10 "
|
||||||
|
"points of margin over the pack's own cut-out, which on the 13.8 kWh "
|
||||||
|
"reference pack is 1.57x the guard's worst measured day",
|
||||||
|
PEAK_OPTION_DEFAULTS["peak_soc_floor"]
|
||||||
|
- PEAK_OPTION_DEFAULTS["bms_soc_floor"] == 10
|
||||||
|
and 0.10 * 13800.0 / WH_BAD > 1.5)
|
||||||
|
check("...and it is a SEPARATE KEY from maintenance_soc_floor, whose SHIPPED "
|
||||||
|
f"VALUE ({MAINT_FLOOR:.0f} %) is not this one ({SOC_FLOOR:.0f} %) - which "
|
||||||
|
"is the argument for not sharing them, measured off config.yaml rather "
|
||||||
|
"than asserted: they are a drain TARGET and a spend LIMIT, and the site "
|
||||||
|
"that wants one does not thereby want the other",
|
||||||
|
MAINT_FLOOR != SOC_FLOOR
|
||||||
|
and "maintenance_soc_floor" not in PEAK_OPTION_DEFAULTS)
|
||||||
|
|
||||||
|
|
||||||
|
# ==============================================================================
|
||||||
|
print()
|
||||||
|
print("10. mutation: what defeats these guards, and which check bites")
|
||||||
|
|
||||||
# Each entry re-implements ONE defeat and reports whether a check above would
|
# Each entry re-implements ONE defeat and reports whether a check above would
|
||||||
# have gone red. The last row is the honest one: it does NOT bite, and saying so
|
# have gone red. The last row is the honest one: it does NOT bite, and saying so
|
||||||
@@ -1199,7 +1819,7 @@ MUT.append(("blindness() returns None - the degenerate 0 W projection is graded"
|
|||||||
# 2. the frozen term dropped from the guard's inputs.
|
# 2. the frozen term dropped from the guard's inputs.
|
||||||
MUT.append(("frozen=False - SAFETY-18's term dropped",
|
MUT.append(("frozen=False - SAFETY-18's term dropped",
|
||||||
not decide(p_frozen, batt_w=-RAILED, cap_w=CAP_W, reading=None,
|
not decide(p_frozen, batt_w=-RAILED, cap_w=CAP_W, reading=None,
|
||||||
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S, soc=SOC_OK, soc_floor=SOC_FLOOR,
|
||||||
frozen=False).engaged and d_frozen.engaged,
|
frozen=False).engaged and d_frozen.engaged,
|
||||||
"part 4: 'THE BACKSTOP: SAFETY-18's runaway ... cut to 0 W'"))
|
"part 4: 'THE BACKSTOP: SAFETY-18's runaway ... cut to 0 W'"))
|
||||||
|
|
||||||
@@ -1247,12 +1867,68 @@ MUT.append(("NOT_OBSERVED silently replaced by a peak of 0.0 W",
|
|||||||
"NOTHING - and by construction: the ceiling is max(cap, peak), so a "
|
"NOTHING - and by construction: the ceiling is max(cap, peak), so a "
|
||||||
"zero peak is the TIGHTEST possible input to it"))
|
"zero peak is the TIGHTEST possible input to it"))
|
||||||
|
|
||||||
|
# ---- SAFETY-24's own defeats ------------------------------------------------
|
||||||
|
# 8. the SoC gate removed altogether - i.e. the guard exactly as SAFETY-07
|
||||||
|
# shipped it. Re-derived on the same modelled pack, not described.
|
||||||
|
MUT.append(("the SoC gate removed - SAFETY-07's unbounded forced discharge",
|
||||||
|
BEFORE["min_soc"] <= BMS_FLOOR and AFTER["min_soc"] > BMS_FLOOR,
|
||||||
|
"part 9: 'the forced discharge STOPS AT THE CONFIGURED FLOOR'"))
|
||||||
|
|
||||||
|
# 9. an unreadable SoC read as a full battery. THE DISARMING DIRECTION, and the
|
||||||
|
# one this project has actually shipped once (NOTES.md 4.4b).
|
||||||
|
MUT.append(("`soc or 100` - an unreadable SoC read as a full battery",
|
||||||
|
discharge_permitted(float(None or 100), SOC_FLOOR) is None
|
||||||
|
and d_unread.floor_limited,
|
||||||
|
"part 8: 'an unreadable SoC is refused, and refused with its OWN "
|
||||||
|
"reason'"))
|
||||||
|
|
||||||
|
# 10. the gate moved ABOVE the `wanted > 0` test, i.e. graded where it is
|
||||||
|
# degenerate. Counted on the healthy day rather than argued: every quiet
|
||||||
|
# cycle would report the peak was about to be exceeded.
|
||||||
|
_early = sum(1 for _t in (500.0, 1000.0, 2000.0)
|
||||||
|
if discharge_permitted(SOC_FLOOR - 1.0, SOC_FLOOR) is not None
|
||||||
|
and not decide(PeakTracker.project(
|
||||||
|
averager_at(_t, 450.0), B + timedelta(seconds=450)),
|
||||||
|
batt_w=BATT_NOW, cap_w=CAP_W, reading=None,
|
||||||
|
achievable_w=LIVE_MAX_W, max_hold_s=MAX_HOLD_S,
|
||||||
|
soc=SOC_FLOOR - 1.0, soc_floor=SOC_FLOOR).engaged)
|
||||||
|
MUT.append((f"the SoC gate moved above the `wanted > 0` test ({_early} quiet "
|
||||||
|
f"quarters would have alarmed)",
|
||||||
|
_early > 0 and not d_quiet.floor_limited,
|
||||||
|
"part 8: 'an empty pack on a quarter that does not need shaving is "
|
||||||
|
"IDLE, not floor-limited'"))
|
||||||
|
|
||||||
|
# 11. rule 8 written `<` instead of `<=`, so a floor EQUAL to the BMS cut-out
|
||||||
|
# is accepted and buys zero margin.
|
||||||
|
MUT.append(("validate rule 8 written `<` instead of `<=`",
|
||||||
|
len(rule8(validate_startup_config(
|
||||||
|
opts24(peak_soc_floor=BMS_FLOOR)))) == 1,
|
||||||
|
"part 9: 'so is a floor EXACTLY AT it, which is the interesting "
|
||||||
|
"case'"))
|
||||||
|
|
||||||
|
# 12. the floor-limited branch filing `wanted` anyway - a report with no action,
|
||||||
|
# which is the shape a "just log it" review comment produces.
|
||||||
|
MUT.append(("floor-limited reported but the floor still filed at `wanted`",
|
||||||
|
near(d_lim.floor_w, 0.0) and d_lim.wanted_w > 0.0,
|
||||||
|
"part 8: 'at the floor it STOPS, and the floor it files is 0 W'"))
|
||||||
|
|
||||||
|
# 13. THE SECOND ONE THAT DOES NOT BITE, and it is a real limitation rather than
|
||||||
|
# a defect. Stated, because the alternative is a reader believing this card
|
||||||
|
# bounds more than it does.
|
||||||
|
_loop_unbounded = near(r_disch.target_w, 1800.0, 1e-9)
|
||||||
|
MUT.append(("the grid-following loop discharging past this floor",
|
||||||
|
not _loop_unbounded,
|
||||||
|
"NOTHING, ON PURPOSE - this card bounds THE PEAK GUARD's forced "
|
||||||
|
"discharge, the thing SAFETY-07 introduced. SAFETY-18's finding "
|
||||||
|
"that the loop itself has no SoC guard is still open, and a `lo` "
|
||||||
|
"limit is structurally incapable of closing it"))
|
||||||
|
|
||||||
for label, caught, where in MUT:
|
for label, caught, where in MUT:
|
||||||
print(f" {'caught' if caught else 'NOT CAUGHT':>10} {label}")
|
print(f" {'caught' if caught else 'NOT CAUGHT':>10} {label}")
|
||||||
print(f" {where}")
|
print(f" {where}")
|
||||||
check("the six mutations that CAN disarm this guard are each caught by a check "
|
check("the eleven mutations that CAN disarm these guards are each caught by a "
|
||||||
"above - a guard whose checks survive its own defeat is not a guard",
|
"check above - a guard whose checks survive its own defeat is not a "
|
||||||
all(m[1] for m in MUT[:6]))
|
"guard", all(m[1] for m in MUT[:6]) and all(m[1] for m in MUT[7:12]))
|
||||||
check("...and the seventh is honestly reported as not caught, because it cannot "
|
check("...and the seventh is honestly reported as not caught, because it cannot "
|
||||||
"disarm anything: `max(cap, peak)` makes a zero peak the strictest "
|
"disarm anything: `max(cap, peak)` makes a zero peak the strictest "
|
||||||
"ceiling there is, so the disarming direction is closed by the shape of "
|
"ceiling there is, so the disarming direction is closed by the shape of "
|
||||||
@@ -1261,6 +1937,11 @@ check("...and the seventh is honestly reported as not caught, because it cannot
|
|||||||
"same zero into FULL freedom, which part 3 shows is why headroom_w() is "
|
"same zero into FULL freedom, which part 3 shows is why headroom_w() is "
|
||||||
"not consumed here", not MUT[6][1]
|
"not consumed here", not MUT[6][1]
|
||||||
and quarter_ceiling_w(CAP_W, _zero_peak)[0] == CAP_W)
|
and quarter_ceiling_w(CAP_W, _zero_peak)[0] == CAP_W)
|
||||||
|
check("...and so is the last one, which is not a defeat at all but the EDGE OF "
|
||||||
|
"THIS CARD: the grid-following loop can still take the pack past this "
|
||||||
|
"floor, because the floor bounds the peak guard's own forced discharge "
|
||||||
|
"and a `lo` limit cannot cap a discharge. Saying so here is worth more "
|
||||||
|
"than a green line that would be untrue", not MUT[12][1])
|
||||||
|
|
||||||
|
|
||||||
# ==============================================================================
|
# ==============================================================================
|
||||||
|
|||||||
Reference in New Issue