2 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5 0a617c5482 TEL-01 review fixes: stop the age sensor tripping installs that have no meter
T-1, and it was a fleet-wide trip to zero. publish() emitted p1_age
unconditionally, and published_age_s counts from P1Ingest.__init__ when no
sample has ever arrived. With meter_source defaulting to off, every existing
install would have published sensor.p1_sample_age_s climbing without bound; the
ESP32 does `has_state() && state >= max_age_s` and forces the layer-1 failsafe,
so each of them would have pinned its inverter at 0 W within 30 s. Exactly the
opposite of the zero-regression the off default was for. The key is now omitted
from the payload AND from MQTT discovery when P1 is off, so the entity does not
exist at all - which is the status quo, and what has_state() is testing for.
The predicate is one function, is_enabled(), because the grid reading, the task
start and the discovery announcement have to agree or this comes back.

T-2, connect no longer manufactures a sample. get_states returns whatever HA
currently holds, which after a Core restart is a RestoreEntity value of unknown
age; stamping it with ingest_ts=now reset the age and reported a fresh meter
that could have been dead for an hour. run()'s own docstring already said a
reconnect must emit nothing - the code disagreed with it, and a test asserted
the violation. The cache is still primed, so the first real state_changed
builds a complete sample; the age just stays honest until one arrives.

T-3, gaps are no longer filled with the last held value. The averager held a
sample forward across any interval, so a meter dying at 5 kW and returning ten
minutes later credited 5 kW x 600 s to the capacity-tariff accumulator - a
fabricated peak on a permanent record. The hold is capped at max_age_s: past
that the stretch is walked so block boundaries still land correctly, but
nothing accumulates and elapsed does not grow, which is what finally makes the
comment about a gap dragging the billed average down true. Same threshold for
control and billing: a reading too old to steer by is too old to bill by.

T-4, the out-of-order/duplicate guard is covered. It was untested, and the
reason is worth recording: the obvious assertion passes without the guard,
because the negative interval is separately refused by the covered > 0 test.
What the guard prevents is the timestamp REWIND, which only shows up one sample
later as a re-integrated window. The test now goes one sample later.

T-6, DOCS was wrong about latency. meter_max_age_s and stale_input_s stack, so
meter death to 0 W is 45 s and not 30. Documented as a table with both clocks.

Also documented the T-5 asymmetry rather than papering over it: the age
measures arrival, not change, so a stuck MQTT bridge republishing its last
telegram still looks fresh. Correct on ha_dsmr, not detectable on mqtt_p1
without a change-detector. Written up as a known limit.

Writing the T-1 test caught a second defect in the test itself: it recorded
only MQTT topics, and object_id lives in the payload, so "the age sensor is not
announced" had been passing for the wrong reason.

test_p1.py: 99 -> 122 checks. 14 mutations run, all 14 red, files restored
byte-identical - including one per fix above.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-24 22:16:34 +02:00
glenn schrooyenandClaude Opus 5 2097b7aaf6 TEL-01: P1 ingestion, with the derivation and the age the EMS owns
A Belgian P1 meter publishes two UNSIGNED registers, not one signed figure.
Until now the add-on asked the installer to bridge that gap with a template
sensor, which put the sign convention of the whole control loop in a text box.
This moves it into the EMS: net = import - export, derived once, in one place,
with a test that fails if anyone inverts it.

Two transports behind one contract, chosen by `meter_source`: the HA WebSocket
subscribing to the DSMR integration's entities, and MQTT on a configurable
topic. Everything downstream reads P1Ingest, so switching is a config edit.
`meter_source: off` is the default and keeps the existing meter_entity path,
so no installed system changes until it opts in.

The other half is the timestamp. Every accepted sample is stamped at ingest
with a monotonic clock, `meter_max_age_s` is applied to it, and the age is
published as sensor.p1_sample_age_s for the ESP32's stale-input watchdog. That
entity is recomputed against the clock every second rather than only when a
telegram lands, because HA pushes state only on change: a meter frozen at a
constant reading emits nothing and looks, to anything watching the value,
exactly like a meter that has died. The age tells them apart.

Deliberately absent: any fallback to an inverter-side power figure. The
inverter's own AC power correlates 0.998 with battery power and 0.09 with the
real meter, so failing over to it means regulating against your own output.
A gap stays a gap - a reconnect emits no synthetic sample, and a rejected
telegram never resolves to 0 W or refreshes the timestamp.

Quarter-hour averages are time-weighted over clock-aligned blocks rather than
a mean of samples, so a cadence change cannot bias the capacity-tariff figure,
and only offtake is accumulated so a quarter of pure export averages to 0 kW.
Per-phase import is kept separately: on an unbalanced three-phase load the
phase sum and the connection net are different numbers, and only one of them
is billed.

test_p1.py: 99 checks, runnable with a bare interpreter and no meter. Includes
an end-to-end run of the HA transport against a fake Home Assistant websocket.

Stacked on SAFETY-04; nothing here touches control.py.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-24 22:16:34 +02:00
3 changed files with 19 additions and 232 deletions
+1 -24
View File
@@ -142,35 +142,12 @@ behind it would trip the firmware watchdog on a system that is working fine.
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export | | `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
| `step_w` | 10 | Quantisation | | `step_w` | 10 | Quantisation |
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" | | `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** | | `saturation_cycles` | 3 | How many consecutive cycles before freezing. **Do not set to 1** |
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction | | `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog | | `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" | | `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" |
| `auto_start` | false | Start controlling on boot (only after commissioning) | | `auto_start` | false | Start controlling on boot (only after commissioning) |
#### Saturation is counted in cycles, not seconds
The specification states the saturation window as **"> 10 s"**. This add-on counts
**cycles** instead, and that is a deliberate, accepted deviation rather than an
oversight - the acceptance criterion is not met as literally written.
A cycle here is one *changed* meter reading: the controller only runs the loop when the
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
window** - a meter that repeats the same value stalls the counter for as long as it
repeats.
Two reasons that is acceptable:
- the control law is a pure function with no clock, which is what makes it testable
without hardware, and a seconds-based window would have to live in the controller;
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
while it is stalled.
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
and treat the figure as "N meter updates" rather than "N seconds".
#### Why `target_grid_w` is not zero #### Why `target_grid_w` is not zero
The deadband is a one-way ratchet: any resting point inside it holds until The deadband is a one-way ratchet: any resting point inside it holds until
+3 -33
View File
@@ -156,45 +156,15 @@ def compute(
# has been in service on real hardware. It is applied here as well # has been in service on real hardware. It is applied here as well
# because the requirement is that the INTEGRATOR stop accumulating, not # because the requirement is that the INTEGRATOR stop accumulating, not
# only the command. # only the command.
# if not frozen:
# ⚠️ EXACTLY ZERO IS ITS OWN CASE, and it must be handled explicitly
# rather than falling into one of the two branches. "May not wind
# further in the direction it is already pushing" has no referent at
# zero: nothing is wound, and neither direction is "further". Writing
# this as `if i_w > 0 ... else ...` silently files zero under
# rising-only and permanently blocks the first push toward charging -
# the same deadlock as the shrink-only encoding above, mirrored in sign,
# and reachable because main.py resets i_w to exactly 0.0 on every stop
# and every reseed. Measured before the fix: 12 800 of 25 920 frozen
# ticks at i_w == 0.0 held the integrator, 8 304 of them changing the
# emitted command, worst case abandoning a 2 kW charge into a 4 kW
# export.
#
# Freezing at zero would also be pointless: the freeze exists to stop
# accumulation running away, and a first step from zero is bounded by
# the gain, the output clamp and the slew limit like any other.
if not frozen or i_w == 0.0:
i_w = moved i_w = moved
elif i_w > 0:
i_w = min(moved, i_w)
else: else:
i_w = max(moved, i_w) i_w = min(moved, i_w) if i_w > 0 else max(moved, i_w)
# ⚠️ Applied EVERY cycle, frozen or not: the freeze is conditional, this # ⚠️ Applied EVERY cycle, frozen or not: the freeze is conditional, this
# bound is not. It is what makes the worst-case unwind time finite and # bound is not. It is what makes the worst-case unwind time finite and
# knowable instead of a function of how long the error happened to stand. # knowable instead of a function of how long the error happened to stand.
bounded = max(-limit, min(limit, i_w)) i_w = max(-limit, min(limit, i_w))
if bounded != i_w:
# ⚠️ SAFETY-03 (alarm whenever the loop winds into a rail) must watch
# for THIS, not for "clamped" below. At the default limit == max_w the
# integrator bound is reached first and the command derived from it can
# then never exceed max_w, so "clamped" is unreachable on a default
# install - it survives only for a configuration that deliberately lets
# the integrator run above the rail. Two reasons rather than one
# because the two events want different alarms: "i-clamped" is the loop
# winding, "clamped" is a command that came out over the rating anyway.
reason = "i-clamped"
i_w = bounded
want = i_w want = i_w
# ⚠️ Maintenance shaping (charge-only, cheap-window floor) used to live # ⚠️ Maintenance shaping (charge-only, cheap-window floor) used to live
+15 -175
View File
@@ -24,63 +24,6 @@ def check(name, cond):
fails.append(name) fails.append(name)
# ---------------------------------------------------------------------------
# COVERAGE AUDIT - measured, not executed. Read this before adding a mechanism.
#
# THE INVARIANT: every mechanism in compute() must be noticed by AT LEAST TWO
# checks when it is deleted. If you add a mechanism to compute(), re-run the
# audit and add it to the table. If a figure here drops, a check has started
# passing for a reason other than the one it names.
#
# THE TECHNIQUE, because there is no script to run: replace one mechanism in
# control.py with a no-op, run this file, count the failures, restore. That is
# the converse of the usual mutation - not "does a wrong value fail?" but "does
# anyone notice when the mechanism is GONE?". It is kept as a comment rather
# than as tooling on purpose: the only cheap way to automate it is to key on
# source lines, which goes stale silently, and a green audit that has quietly
# stopped testing anything is precisely the failure this ticket exists to fix.
# A comment cannot go stale-green, because it never claims to be running.
#
# Measured at 389d9ec. Numbers are the lead's independent reproduction.
#
# mechanism in compute() checks that fail when deleted
# ------------------------------------------ -----------------------------
# integrator freeze (AC 3) 2
# integrator clamp (AC 1) 6
# integrator bound follows max_w 4
# output clamp 3
# slew limit 4
# output freeze 2
# deadband 5
# quantisation 2
# saturation detector, `saturated_now = False` 11
# saturation duration (AC 2), fires instantly 2
# sat counter reset on a good cycle 6
# target_grid_w bias 3
# i_w=None seeding from prev_w 6
#
# The detector figure is for the `saturated_now = False` form specifically;
# disabling it further down as `frozen = False` is a weaker mutation and gives
# 10. Reproduce the same form or the number will not match.
#
# ⚠️ IT HAS FOUND A DEAD MECHANISM TWICE, BOTH THE SAME WAY: a clamp standing in
# for the mechanism under test. Deleting the integrator freeze once failed
# NOTHING, because the fixtures sat at max_w 2000 and the integrator bound
# truncated a wound value back to exactly 2000 - the assertion passed on the
# clamp. The output clamp was masked the same way by the integrator bound.
# Hence: A FIXTURE MUST SIT CLEAR OF EVERY RAIL IT IS NOT TESTING. Where a test
# names one mechanism, make that mechanism the binding one (see TCLAMP and TF).
#
# ⚠️ RUN MUTATIONS WITH `python -B` AND CLEAR app/__pycache__. CPython
# invalidates a .pyc on (source mtime in whole seconds, source size), so a
# same-second rewrite that also preserves the file size reuses stale bytecode
# and the suite reports on code you are no longer running. It under-reported one
# mutation here as 2 where the true figure is 6. The error is one-directional -
# stale bytecode can only under-report - so every figure above is a lower bound
# at worst, and the two zeros ever recorded were both confirmed by fixing them
# and watching the count rise, which a caching artefact cannot do.
# ---------------------------------------------------------------------------
print("control law") print("control law")
# Deadband: inside meter noise, hold exactly - do not drift. # Deadband: inside meter noise, hold exactly - do not drift.
@@ -98,22 +41,13 @@ check("proportional step (gain 0.6)", d.target_w == 300)
d = compute(prev_w=0, grid_w=-500, actual_w=0, tuning=T) d = compute(prev_w=0, grid_w=-500, actual_w=0, tuning=T)
check("export drives charging", d.target_w == -300) check("export drives charging", d.target_w == -300)
# Clamp. # Clamp
# ⚠️ integrator_max_w is lifted clear of max_w so that the OUTPUT clamp is the d = compute(prev_w=1900, grid_w=1000, actual_w=1900, tuning=Tuning(max_w=2000, slew_w=5000))
# mechanism under test. Left at the default the integrator bound truncates
# first, these two assertions pass on that alone, and deleting the output clamp
# fails nothing - the same masking that hid the integrator freeze.
TCLAMP = Tuning(max_w=2000, slew_w=5000, integrator_max_w=5000)
d = compute(prev_w=1900, grid_w=1000, actual_w=1900, tuning=TCLAMP)
check("clamped to max_w", d.target_w == 2000) check("clamped to max_w", d.target_w == 2000)
# Slew: from 0 with a huge error, no more than slew_w in one cycle. # Slew: from 0 with a huge error, no more than slew_w in one cycle.
d = compute(prev_w=0, grid_w=5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000)) d = compute(prev_w=0, grid_w=5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
check("slew limits one cycle", d.target_w == 1000) check("slew limits one cycle", d.target_w == 1000)
d = compute(prev_w=-1900, grid_w=-1000, actual_w=-1900, tuning=TCLAMP)
check("clamped to -max_w", d.target_w == -2000)
d = compute(prev_w=0, grid_w=-5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
check("slew limits one cycle, charging", d.target_w == -1000)
# Saturation needs DURATION: one diverging cycle must NOT freeze. # Saturation needs DURATION: one diverging cycle must NOT freeze.
t = Tuning(saturation_w=500, saturation_cycles=3) t = Tuning(saturation_w=500, saturation_cycles=3)
@@ -152,12 +86,12 @@ RUNAWAY_CYCLES = 150
HISTORICAL_W = 14768.0 HISTORICAL_W = 14768.0
def runaway(tuning, sign=1): def runaway(tuning):
"""Inverter off: it reports 0 W forever, the error never clears.""" """Inverter off: it reports 0 W forever, the error never clears."""
prev, i_w, sat = 0.0, 0.0, 0 prev, i_w, sat = 0.0, 0.0, 0
worst_i, worst_cmd = 0.0, 0.0 worst_i, worst_cmd = 0.0, 0.0
for _ in range(RUNAWAY_CYCLES): for _ in range(RUNAWAY_CYCLES):
d = compute(prev_w=prev, grid_w=sign * RUNAWAY_ERROR, actual_w=0.0, d = compute(prev_w=prev, grid_w=RUNAWAY_ERROR, actual_w=0.0,
tuning=tuning, sat_count=sat, i_w=i_w) tuning=tuning, sat_count=sat, i_w=i_w)
prev, i_w, sat = d.target_w, d.i_w, d.sat_count prev, i_w, sat = d.target_w, d.i_w, d.sat_count
worst_i = max(worst_i, abs(i_w)) worst_i = max(worst_i, abs(i_w))
@@ -179,12 +113,6 @@ check(f"runaway with the detector defeated: integrator still bounded ({wi:.0f} W
wi <= TD.max_w) wi <= TD.max_w)
check("runaway with the detector defeated: command still <= max_w", wc <= TD.max_w) check("runaway with the detector defeated: command still <= max_w", wc <= TD.max_w)
# The mirror: the same runaway driving the other way. An export that never
# clears winds the integrator negative just as hard.
wi, wc = runaway(Tuning(max_w=2000), sign=-1)
check(f"runaway (export direction): integrator bounded at {wi:.0f} W", wi <= 2000)
check("runaway (export direction): emitted command <= max_w", wc <= 2000)
# The bound is a separate quantity, and the useful direction is BELOW max_w: # The bound is a separate quantity, and the useful direction is BELOW max_w:
# there it binds first and caps unwind latency tighter than the rail does. # there it binds first and caps unwind latency tighter than the rail does.
d = compute(prev_w=0, grid_w=6000, actual_w=0, d = compute(prev_w=0, grid_w=6000, actual_w=0,
@@ -193,22 +121,11 @@ check("integrator bound binds independently of the output clamp",
d.i_w == 1000 and d.target_w == 1000) d.i_w == 1000 and d.target_w == 1000)
# Freeze = may not wind further in the direction it is already pushing. # Freeze = may not wind further in the direction it is already pushing.
# ⚠️ max_w is raised WELL above the fixtures on purpose. At the default 2000 TF = Tuning(saturation_w=500, saturation_cycles=3)
# the integrator bound truncates a wound value back to exactly 2000 and
# satisfies these assertions on its own, so deleting the freeze outright
# failed nothing - the clamp was standing in for the mechanism under test.
# Any fixture here must sit clear of every rail, or it tests the rail.
TF = Tuning(saturation_w=500, saturation_cycles=3, max_w=5000)
f1 = compute(prev_w=2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0) f1 = compute(prev_w=2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0)
check("frozen: integration does not wind further", f1.i_w == 2000.0 and f1.frozen) check("frozen: integration does not wind further", f1.i_w == 2000.0 and f1.frozen)
f2 = compute(prev_w=2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0) f2 = compute(prev_w=2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0)
check("frozen: unwinding is still allowed", f2.i_w < 2000.0) check("frozen: unwinding is still allowed", f2.i_w < 2000.0)
# ...and the same two on the charging side. Every freeze rule in this file has
# a mirror, because the one that did not is the defect that got through review.
f3 = compute(prev_w=-2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=-2000.0)
check("frozen (charging): integration does not wind further", f3.i_w == -2000.0)
f4 = compute(prev_w=-2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=-2000.0)
check("frozen (charging): unwinding is still allowed", f4.i_w > -2000.0)
# ⚠️ REGRESSION, and the reason the first cut of SAFETY-04 was rejected. A # ⚠️ REGRESSION, and the reason the first cut of SAFETY-04 was rejected. A
# freeze encoded as "only corrections that shrink |i_w|" is unsatisfiable for # freeze encoded as "only corrections that shrink |i_w|" is unsatisfiable for
@@ -228,50 +145,6 @@ check("frozen at i_w=0: the freeze then clears", not z2.frozen)
z3 = compute(prev_w=100, grid_w=-1000, actual_w=800, tuning=T, sat_count=3, i_w=100.0) z3 = compute(prev_w=100, grid_w=-1000, actual_w=800, tuning=T, sat_count=3, i_w=100.0)
check("frozen at i_w=+100: a 1 kW export still moves the command", check("frozen at i_w=+100: a 1 kW export still moves the command",
z3.frozen and z3.target_w < 0) z3.frozen and z3.target_w < 0)
z4 = compute(prev_w=-100, grid_w=1000, actual_w=-800, tuning=T, sat_count=3, i_w=-100.0)
check("frozen at i_w=-100: a 1 kW import still moves the command",
z4.frozen and z4.target_w > 0)
# ⚠️ EXACTLY ZERO, BOTH DIRECTIONS. This boundary has a history: the first cut
# deadlocked here under import, and the fix for it deadlocked here under export
# because `if i_w > 0 ... else ...` files 0.0 under rising-only. main.py resets
# i_w to exactly 0.0 on every stop and every reseed, so it is a normal state,
# not a corner.
zi = compute(prev_w=0, grid_w=2000, actual_w=600, tuning=T, sat_count=3, i_w=0.0)
check("frozen at i_w=0.0: an import push moves the integrator",
zi.frozen and zi.i_w > 0)
ze = compute(prev_w=0, grid_w=-2000, actual_w=-600, tuning=T, sat_count=3, i_w=0.0)
check("frozen at i_w=0.0: an export push moves the integrator",
ze.frozen and ze.i_w < 0)
# The COMMAND still holds at 0 W in that second case, and that is release/1.0's
# rule, not a leftover: at prev_w == 0 the output freeze forbids starting to
# charge while saturated, because commanding 0 while the inverter reports
# hundreds of watts means something else is driving the bus. Asserted so that
# nobody "fixes" it by accident - the integrator moving is what this ticket
# owns, the command rule belongs to the output freeze.
check("frozen at i_w=0.0: the output freeze still blocks a charge from 0 W",
ze.target_w == 0.0)
# Where prev_w is already charging the output freeze does NOT block, and there
# the difference reaches the wire: held at 0.0 the integrator abandons the
# charge mid-export.
zc = compute(prev_w=-2000, grid_w=-4000, actual_w=-600, tuning=T, sat_count=3, i_w=0.0)
check("frozen at i_w=0.0: a charge is not abandoned during heavy export",
zc.target_w == -2000.0)
# The general property, rather than another handful of points: while frozen the
# integrator may be held ONLY when the correction would push it further from
# zero on the side it already sits. Any other hold is a deadlock.
stuck = []
for i0 in [x * 25.0 for x in range(-80, 81)]:
for g in [x * 100.0 for x in range(-40, 41)]:
err = g - T.target_grid_w
if abs(err) < T.deadband_w:
continue
dd = compute(prev_w=0.0, grid_w=g, actual_w=1500.0, tuning=T, sat_count=3, i_w=i0)
if dd.i_w == i0 and not ((i0 > 0 and err > 0) or (i0 < 0 and err < 0)):
stuck.append((i0, g))
check(f"frozen integrator never deadlocks, over {161*81} states"
+ (f" (e.g. {stuck[0]})" if stuck else ""), not stuck)
# False-positive guard: a normal 2 kW load step must not trip the detector, # False-positive guard: a normal 2 kW load step must not trip the detector,
# because the plant needs several cycles to catch up on every one of them. # because the plant needs several cycles to catch up on every one of them.
@@ -323,67 +196,34 @@ print("SAFETY-04: the i_w=None path is still release/1.0, exactly")
def legacy(prev, grid, actual, t, sat_count): def legacy(prev, grid, actual, t, sat_count):
"""release/1.0's control law, transcribed. Do not 'improve' this.""" """release/1.0's control law, transcribed. Do not 'improve' this."""
reason = "tracking"
sc = min(sat_count + 1, 10) if abs(prev - actual) > t.saturation_w else 0 sc = min(sat_count + 1, 10) if abs(prev - actual) > t.saturation_w else 0
frozen = sc >= t.saturation_cycles frozen = sc >= t.saturation_cycles
error = grid - t.target_grid_w error = grid - t.target_grid_w
if abs(error) < t.deadband_w: want = prev if abs(error) < t.deadband_w else prev + t.gain * error
want, reason = prev, "deadband"
else:
want = prev + t.gain * error
target = max(-t.max_w, min(t.max_w, want)) target = max(-t.max_w, min(t.max_w, want))
if target != want: target = max(prev - t.slew_w, min(prev + t.slew_w, target))
reason = "clamped"
slewed = max(prev - t.slew_w, min(prev + t.slew_w, target))
if slewed != target:
reason = "slew-limited"
target = slewed
if frozen: if frozen:
target = min(target, prev) if prev > 0 else max(target, prev) target = min(target, prev) if prev > 0 else max(target, prev)
reason = "saturated-freeze"
step = max(1, int(t.step_w)) step = max(1, int(t.step_w))
return float(round(target / step) * step), sc, frozen, reason return float(round(target / step) * step), sc
# ⚠️ Compare EVERYTHING observable, not just the number. A previous version of # Exhaustive over the interesting corners, both freeze states, both signs, and
# this sweep compared (target_w, sat_count) only and passed 3024 cases while # either side of the deadband. This is what makes the claim in control.py's
# `reason` had silently lost a value - which is the kind of thing a sweep this # integrator comment a checked fact rather than an assertion.
# broad exists to catch. `frozen` and `reason` are both in the tuple now.
#
# The one deliberate rename: what release/1.0 called "clamped" is now
# "i-clamped", because the truncation happens on the integrator before the
# command is derived from it. Aliased here rather than papered over - if any
# OTHER reason ever diverges, this check goes red.
ALIAS = {"i-clamped": "clamped"}
diffs = [] diffs = []
seen = set()
for tune in (Tuning(), Tuning(target_grid_w=-10.0), Tuning(max_w=5000, slew_w=5000)): for tune in (Tuning(), Tuning(target_grid_w=-10.0), Tuning(max_w=5000, slew_w=5000)):
for prev in (-2000.0, -500.0, -100.0, 0.0, 100.0, 500.0, 2000.0): for prev in (-2000.0, -500.0, -100.0, 0.0, 100.0, 500.0, 2000.0):
for grid in (-6000.0, -1000.0, -500.0, -14.0, 0.0, 14.0, 500.0, 1000.0, 6000.0): for grid in (-6000.0, -1000.0, -500.0, -14.0, 0.0, 14.0, 500.0, 1000.0, 6000.0):
for actual in (-2000.0, 0.0, 600.0, 2000.0): for actual in (-2000.0, 0.0, 600.0, 2000.0):
for sc in (0, 2, 3, 9): for sc in (0, 2, 3, 9):
d = compute(prev, grid, actual, tune, sc) # i_w defaults to None d = compute(prev, grid, actual, tune, sc) # i_w defaults to None
seen.add(d.reason) lt, lsc = legacy(prev, grid, actual, tune, sc)
got = (d.target_w, d.sat_count, d.frozen, if (d.target_w, d.sat_count) != (lt, lsc):
ALIAS.get(d.reason, d.reason)) diffs.append((prev, grid, actual, sc, d.target_w, lt))
if got != legacy(prev, grid, actual, tune, sc): check(f"i_w=None reproduces release/1.0 over {3*7*9*4*4} cases"
diffs.append((prev, grid, actual, sc, got,
legacy(prev, grid, actual, tune, sc)))
check(f"i_w=None reproduces release/1.0 over {3*7*9*4*4} cases, reason included"
+ (f" (first diff {diffs[0]})" if diffs else ""), not diffs) + (f" (first diff {diffs[0]})" if diffs else ""), not diffs)
# ...and the rename is not a quiet deletion: the signal SAFETY-03 alarms on has
# to actually occur in that sweep, or its hook is dead.
check("the integrator clamp reports itself as 'i-clamped'", "i-clamped" in seen)
# "clamped" stays reachable, but only where the integrator is deliberately
# allowed above the rail - then BOTH fire and the output clamp, which describes
# the value actually emitted, is the one reported.
dc = compute(prev_w=0, grid_w=6000, actual_w=0,
tuning=Tuning(max_w=2000, integrator_max_w=3000, slew_w=5000))
check("the output clamp still reports 'clamped' when it is the binding one",
dc.reason == "clamped" and dc.i_w == 3000 and dc.target_w == 2000)
print("capacity tariff") print("capacity tariff")
check("no forecast means no cap", maintenance_charge_floor(2500, None, 3500) == 2500) check("no forecast means no cap", maintenance_charge_floor(2500, None, 3500) == 2500)
check("headroom caps the charge", maintenance_charge_floor(2500, 2000, 3500) == 1500) check("headroom caps the charge", maintenance_charge_floor(2500, 2000, 3500) == 1500)