Commit Graph
4 Commits
Author SHA1 Message Date
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
ev03-devandClaude 678ea13895 EV-03 round 2: a missing car power is unknown, and mode3 E/F has a state
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
- CarTracker.car_w returns None when the current reading carries no power
  (power entity unavailable or in a non-power unit); it can no longer raise
  into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 12:02:17 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00