Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
glenn schrooyenandClaude f31dcb62b6 EV-04 round 3: undo restores the current in shadow mode too, energy rule catches a frozen 6 A figure, settle after a refused select
checks / unit (pull_request) Failing after 21m10s
infra-pin / fresh (pull_request) Successful in 1s
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 07:59:15 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00