test_maint28 quarter bound back to aim + 1 W (now 5925 W; the guard alone landed
5960.1 W): the pack's limit is the largest floor the guard claimed in the 15-minute
period. A pack in peak_guard.held (the guard places its claim on the others) gets
0 W. test_safety84 n2_charge_banked re-pinned again, its banked quarters asserted
under the aim. New test: guard claims on the other pack only.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner go 2026-11-13. The pack in maintenance CHARGE gets a unit limit with hi
= the guard's own floor while the pause holds, at any SoC (replaces the
under-reserve limit). Sim 45 min: A give 2.39 -> 0.02 kWh, SoC 49.0 %, charge
back 4 s. test_safety84 n2_charge_banked re-pinned (192 of 480 rows),
test_maint28 quarter bound to the month peak. Tests: test_maint28b.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Rig FAIL (TEST-23, f3f9483). F-1: the hold ended at each guard step because
grid + site_batt_w added a new meter reading to a battery reading up to 10 s
old. It now ends only when no battery reading may pre-date a step up of its
command (Controller._batts_settled()). F-2: while the pause holds, a pack in
maintenance CHARGE at or under its peak reserve is limited to 0 W, so it gives
only what the guard claims for the peak. Sim: Lag.batt_period_s (a held 10 s
register). Tests: test_maint28b.py. DECISIONS updated.
Co-Authored-By: Claude <noreply@anthropic.com>