glenn schrooyenandClaude fb4a449591 MAINT-28 fix-forward round 3: the cap is the guard's largest claim of the period, 0 W for a pack the guard does not place on
checks / unit (pull_request) Successful in 28m17s
infra-pin / fresh (pull_request) Successful in 1s
test_maint28 quarter bound back to aim + 1 W (now 5925 W; the guard alone landed
5960.1 W): the pack's limit is the largest floor the guard claimed in the 15-minute
period. A pack in peak_guard.held (the guard places its claim on the others) gets
0 W. test_safety84 n2_charge_banked re-pinned again, its banked quarters asserted
under the aim. New test: guard claims on the other pack only.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 21:21:14 +01:00
glenn schrooyenandClaude 776b84ca20 MAINT-28 fix-forward round 2: while the pause holds, the maintenance pack gives only what the peak guard claims
checks / unit (pull_request) Successful in 27m52s
infra-pin / fresh (pull_request) Successful in 1s
Owner go 2026-11-13. The pack in maintenance CHARGE gets a unit limit with hi
= the guard's own floor while the pause holds, at any SoC (replaces the
under-reserve limit). Sim 45 min: A give 2.39 -> 0.02 kWh, SoC 49.0 %, charge
back 4 s. test_safety84 n2_charge_banked re-pinned (192 of 480 rows),
test_maint28 quarter bound to the month peak. Tests: test_maint28b.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 19:49:19 +01:00
glenn schrooyenandClaude 34b81e8aeb MAINT-28 fix-forward: the peak pause ends only on a settled house estimate, and a pack under its peak reserve gives nothing for the house while it holds
checks / unit (pull_request) Successful in 28m10s
infra-pin / fresh (pull_request) Successful in 1s
Rig FAIL (TEST-23, f3f9483). F-1: the hold ended at each guard step because
grid + site_batt_w added a new meter reading to a battery reading up to 10 s
old. It now ends only when no battery reading may pre-date a step up of its
command (Controller._batts_settled()). F-2: while the pause holds, a pack in
maintenance CHARGE at or under its peak reserve is limited to 0 W, so it gives
only what the guard claims for the peak. Sim: Lag.batt_period_s (a held 10 s
register). Tests: test_maint28b.py. DECISIONS updated.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 16:56:18 +01:00
glenn schrooyenandClaude e7706150e8 MAINT-28: DECISIONS gives the measured reason for the uncapped give (review M-1); ctl_cycle comment one line + pointer (L-1)
checks / unit (pull_request) Successful in 27m38s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 05:53:55 +01:00
glenn schrooyenandClaude 29a8a05f30 MAINT-28: shorter test_maint28 runs (892 s -> ~280 s), digests re-pinned on 1b5f7c9; hold kept through the two short holds (documented); DECISIONS duplicate removed
checks / unit (pull_request) Successful in 40m7s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 02:29:27 +01:00
glenn schrooyenandClaude edf30f345a MAINT-28: keep the single shaping_suspended(.., maint_aim) call site (test_peak_margin pin); shaping_held takes its answer
checks / unit (pull_request) Successful in 32m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:58:19 +01:00
glenn schrooyenandClaude 8640bfcbc1 MAINT-28: hold only where MAINT-24 moved the aim (banked peak above the cap); test_safety119 pins stay
checks / unit (pull_request) Failing after 34m27s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:13:57 +01:00
glenn schrooyenandClaude 92f0387415 MAINT-28: reset the hold every cycle, test it; digests vs 1b5f7c9; DECISIONS numbers and mutants
checks / unit (pull_request) Failing after 36m49s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:44:32 +01:00
glenn schrooyenandClaude 4f9aa5223f MAINT-28: the hold is for N=2 and up (SAFETY-87 N=1 pins), N=1 peak digest test
checks / unit (pull_request) Failing after 36m51s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:28:01 +01:00
glenn schrooyenandClaude 8cd10ee6aa MAINT-28: during a real peak the maintenance charge stays paused until the house is clear of the aim
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m11s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 21:51:56 +01:00
glenn schrooyenandClaude 54a738dd87 MAINT-24: a started maintenance charge gets the cheap night
checks / unit (pull_request) Failing after 41m45s
infra-pin / fresh (pull_request) Successful in 2s
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:07:44 +01:00
goodwe-agent c50e2279dd SAFETY-136: a gentler loop on a slow meter until the last move shows
checks / unit (pull_request) Successful in 26m18s
infra-pin / fresh (pull_request) Successful in 2s
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 14:49:26 +01:00
glenn schrooyenandClaude 3939211176 MAINT-21: app/ctl_cycle.py - Controller.cycle, whole
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:29:52 +01:00