Review of 17a7b29:
- Critical: every way out of Solar (Off, Stop, shadow, safety stop, charger
error, stuck reading, no car) now owes a 0 A until the charger takes it:
tried again 60 s apart, 3 times (EV-04's rule), then the gave-up row and
CHARGER_REFUSED; never over another writer. Shutdown does not trust last_a
while a write of ours is unconfirmed. The card no longer says paused while
the 0 A is not taken.
- Major: an excess episode is taken off the car once, measured from the car's
power when it began, until the car shows it and 15 s more.
Tests: refused-then-accepted 0 A for each exit, a 0 A never taken, shutdown
during a start write's read-back, a cut from 16 A with a slow car; the fuzz
checks refused exits of every kind (N9).
Co-Authored-By: Claude <noreply@anthropic.com>
Owner 2026-11-18 (dev finding 1, brief v4 Expected 8): while a battery is
above its cut-out, the car's peak cut waits until the guard has wanted power
for 15 s in a row (CUT_WAIT_S), so a cloud edge the batteries catch does not
pause the car. It cuts at once with no battery able, or with 120 s or less of
the 15-minute period left (CUT_NEAR_END_S: waiting 15 s then costs at most
8/7 of the cut, taken off the car at once).
Tests: T21/T22 cut at 15 s and not sooner, the period lands under the aim;
T21b a house step and a cloud edge the batteries catch: no cut, no pause;
T24 (c) late in the period: the cut at once, under the aim; T12's cut row
with the batteries at their cut-out. The harness's battery level model was
1000x too fast (round 1); fixed. The 10-hour day: 0 cut pauses in both
priorities.
Co-Authored-By: Claude <noreply@anthropic.com>
Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.
- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
that pinned "Solar is refused" / "three entities" updated.
Co-Authored-By: Claude <noreply@anthropic.com>